Product Range Overview
Deye offers a comprehensive range of solar inverters designed for various applications. The product line includes:
- Single Phase String Inverters
- Microinverters
- Three Phase String Inverters (LV)
- Single Phase Hybrid Inverters
- Three Phase String Inverters
- Three Phase Hybrid Inverters
- Accessories & Monitoring Solutions
Single Phase Hybrid Inverters
Deye's Single Phase Hybrid Inverters are designed for efficient solar energy management, offering battery storage capabilities and grid-tie functionality. Key features across the range include:
- Colorful touch LCD display with IP65 protection degree
- Ability to AC couple to existing solar systems
- Scalable parallel operation: Up to 16 units for on-grid and off-grid configurations, supporting multiple battery parallel connections
- High charging/discharging current capabilities (e.g., 140A, 190A, 250A depending on model)
- Programmable battery charging/discharging schedules (6 time periods)
- Support for energy storage from diesel generators
Model Series: SUN-3K/3.6K/5K/6K-SG04LP1-EU-SMx
Models include: SUN-3K-SG04LP1-24-EU-SM1, SUN-3K-SG04LP1-EU-SM1, SUN-3.6K-SG04LP1-EU-SM2, SUN-5K-SG04LP1-EU-SM2, SUN-6K-SG04LP1-EU-SM2.
Parameter | SUN-3K-SG04LP1-24-EU-SM1 | SUN-3K-SG04LP1-EU-SM1 | SUN-3.6K-SG04LP1-EU-SM2 | SUN-5K-SG04LP1-EU-SM2 | SUN-6K-SG04LP1-EU-SM2 |
---|---|---|---|---|---|
Battery Type | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 20-30 | 40-60 | 40-60 | 40-60 | 40-60 |
Max. Charging Current (A) | 140 | 70 | 90 | 120 | 135 |
Max. Discharging Current (A) | 140 | 70 | 90 | 120 | 135 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||||
Number of Battery Input | 1 | ||||
Max. PV Access Power (W) | 6000 | 6000 | 7200 | 10000 | 12000 |
Max. PV Input Power (W) | 4800 | 4800 | 5760 | 8000 | 9600 |
Max. PV Input Voltage (V) | 500 | ||||
Start-up Voltage (V) | 125 | ||||
MPPT Voltage Range (V) | 150-425 | ||||
Rated PV Input Voltage (V) | 370 | ||||
Max. Operating PV Input Current (A) | 18 | 18+18 | 27 | 27 | 27 |
Max. Input Short-Circuit Current (A) | 27 | 27+27 | 27 | 27 | 27 |
No. of MPP Trackers/No. of Strings MPP Tracker | 1/1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 |
Rated AC Input/Output Active Power (W) | 3000 | 3600 | 5000 | 6000 | 6000 |
Max. AC Input/Output Apparent Power (VA) | 3300 | 3960 | 5500 | 6600 | 6600 |
Rated AC Input/Output Current (A) | 13.7/13.1 | 16.4/15.7 | 22.8/21.8 | 27.3/26.1 | 27.3/26.1 |
Max. AC Input/Output Current (A) | 15/14.4 | 18/17.3 | 25/24 | 30/28.7 | 30/28.7 |
Max. Continuous AC Passthrough (grid to load) (A) | 35 | 40 | 40 | 40 | 40 |
Peak Power (off-grid) (W) | 2 times of rated power, 10s | ||||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | ||||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||
Grid Connection Form | L+N+PE | ||||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
DC Injection Current | <0.5% In | ||||
Max. Efficiency | 97.6% | ||||
Euro Efficiency | 96.5% | ||||
MPPT Efficiency | >99% |
Model Series: SUN-7K/7.6K/8K-SG05LP1-EU-SM2
Models include: SUN-7K-SG05LP1-EU-SM2, SUN-7.6K-SG05LP1-EU-SM2, SUN-8K-SG05LP1-EU-SM2.
Parameter | SUN-7K-SG05LP1-EU-SM2 | SUN-7.6K-SG05LP1-EU-SM2 | SUN-8K-SG05LP1-EU-SM2 |
---|---|---|---|
Battery Type | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 |
Max. Charging Current (A) | 175 | 190 | 190 |
Max. Discharging Current (A) | 175 | 190 | 190 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||
Number of Battery Input | 1 | ||
Max. PV Access Power (W) | 14000 | 15200 | 16000 |
Max. PV Input Power (W) | 11200 | 12160 | 12800 |
Max. PV Input Voltage (V) | 500 | ||
Start-up Voltage (V) | 125 | ||
MPPT Voltage Range (V) | 150-425 | ||
Rated PV Input Voltage (V) | 370 | ||
Max. Operating PV Input Current (A) | 26+26 | 26+26 | 26+26 |
Max. Input Short-Circuit Current (A) | 34+34 | 34+34 | 34+34 |
No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | 2/2+2 | 2/2+2 |
Rated AC Input/Output Active Power (W) | 7000 | 7600 | 8000 |
Max. AC Input/Output Apparent Power (VA) | 7700 | 8360 | 8800 |
Rated AC Input/Output Current (A) | 31.9/30.5 | 34.6/33.1 | 36.4/34.8 |
Max. AC Input/Output Current (A) | 35/33.5 | 38/36.4 | 40/38.3 |
Max. Continuous AC Passthrough (grid to load) (A) | 50 | 50 | 50 |
Peak Power (off-grid) (W) | 2 times of rated power, 10s | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | ||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||
Grid Connection Form | L+N+PE | ||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||
DC Injection Current | <0.5% In | ||
Max. Efficiency | 97.6% | ||
Euro Efficiency | 96.5% | ||
MPPT Efficiency | >99% |
Model Series: SUN-7.6K/8K-SG02LP1-EU-AM2 & SUN-10K/12K-SG02LP1-EU-AM3
Models include: SUN-7.6K-SG02LP1-EU-AM2, SUN-8K-SG02LP1-EU-AM2, SUN-10K-SG02LP1-EU-AM3, SUN-12K-SG02LP1-EU-AM3.
Parameter | SUN-7.6K-SG02LP1-EU-AM2 | SUN-8K-SG02LP1-EU-AM2 | SUN-10K-SG02LP1-EU-AM3 | SUN-12K-SG02LP1-EU-AM3 |
---|---|---|---|---|
Battery Type | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 | 40-60 |
Max. Charging Current (A) | 190 | 190 | 220 | 250 |
Max. Discharging Current (A) | 190 | 190 | 220 | 250 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||
Number of Battery Input | 1 | |||
Max. PV Access Power (W) | 15200 | 16000 | 20000 | 24000 |
Max. PV Input Power (W) | 12160 | 12800 | 16000 | 19200 |
Max. PV Input Voltage (V) | 500 | |||
Start-up Voltage (V) | 125 | |||
MPPT Voltage Range (V) | 150-425 | |||
Rated PV Input Voltage (V) | 370 | |||
Max. Operating PV Input Current (A) | 26+26 | 26+26 | 26+26+26 | 26+26+26 |
Max. Input Short-Circuit Current (A) | 44+44 | 44+44 | 44+44+44 | 44+44+44 |
No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | 2/2+2 | 3/2+2+2 | 3/2+2+2 |
Rated AC Input/Output Active Power (W) | 7600 | 8000 | 10000 | 12000 |
Max. AC Input/Output Apparent Power (VA) | 8360 | 8800 | 11000 | 13200 |
Rated AC Input/Output Current (A) | 34.6/33.1 | 36.4/34.8 | 45.5/43.5 | 54.6/52.2 |
Max. AC Input/Output Current (A) | 34.6/33.1 | 36.4/34.8 | 45.5/43.5 | 54.6/52.2 |
Max. Continuous AC Passthrough (grid to load) (A) | 50 | 50 | 60 | 60 |
Peak Power (off-grid) (W) | 2 times of rated power, 10s | |||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | |||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||
Grid Connection Form | L+N+PE | |||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | |||
DC Injection Current | <0.5% In | |||
Max. Efficiency | 97.6% | |||
Euro Efficiency | 96.5% | |||
MPPT Efficiency | >99% |
General Technical Specifications
These specifications apply to Deye's Single Phase Hybrid Inverter range:
- Equipment Protection: Includes DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level.
- Surge Protection Level: TYPE II(DC), TYPE II(AC)
- Interface: RS485/RS232/CAN
- Communication Interface: GPRS/WIFI/Bluetooth/4G/LAN (optional)
- Operating Temperature Range: -40 to +60°C (with derating above 45°C)
- Permissible Ambient Humidity: 0-100%
- Permissible Altitude: 2000m
- Noise: <45 dB
- Ingress Protection (IP) Rating: IP 65
- Inverter Topology: Non-Isolated
- Over Voltage Category: OVC II(DC), OVC III(AC)
- Cabinet Size (WxHxD mm): Varies by model (e.g., 376×470×241.5, 366×589.5×237, 420×670×233 - excluding connectors and brackets)
- Weight (kg): Varies by model (e.g., 17.6, 26.8, 35.6)
- Type of Cooling: Natural Cooling or Intelligent Air Cooling
- Warranty: 5 Years / 10 Years (depending on final installation site)
- Grid Regulation: Compliant with various international standards.
- Safety/EMC Standard: IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105, IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2