Installation Guide for sinop models including: TH1134ZB, TH1134ZB-HC, TH1134ZB Smart Line Voltage Thermostat, TH1134ZB, Smart Line Voltage Thermostat, Line Voltage Thermostat, Voltage Thermostat, Thermostat
ation - Sinope Support
File Info : application/pdf, 2 Pages, 589.48KB
DocumentDocumentYOUR TH1134ZB HC THERMOSTAT TECHNICAL SPECIFICATIONS TH1134ZB/HC Installation Guide Smart Line Voltage Thermostat Full-color display Touch-sensor buttons Touch control Operatlng voltage: 120 / 208 / 240 Vac, 60 Hz TH1134ZB/HC Thermostat Maximum load: 16.7 A / 2000 W @ 120 Vac 16.7 A / 4000 W @ 240 Vac Resistive load only. Minimum load: 1.25 A / 300 W @ 240 Vca 1.25 A / 150 W @ 120 Vca Cooling setpoint range: 61°F to 86°F (16°C to 30°C) Heating setpoint range: 41°F to 86°F (5°C to 30°C) Display range: 32°F to 99°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Operation: 32°F to 122°F (0°C to 50°C) Resolution: ± 0.5°C (± 1°F) Protocol: Zigbee 3.0 Frequency: 2.4 GHz Transmission power: +20 dBm Receiver sensitivity: -108 dBm Compatible with an electric heating system such as: · Baseboard heater [short cycle] · Convector [short cycle] · Fan-forced convector [long cycle) · Radiant ceiling heating · Ductless air conditioners and heat pumps units with the HP6000ZB series controller* * Scan the QR code to view the list of compatible devices or visit www.support.sinopetech.com/en/1.1.29.3/ Warnings The installation of this thermostat must be performed by a certified electrician and comply with the national and local electrical codes and regulations. Special CO/ ALR solderless connectors must be used when connecting with aluminum conductors. INSTALL YOUR THERMOSTAT 1 Make sure that the breakers for your heating system are off at the main electrical panel. 4 Replace the cover and lock. 2 Unlock and lift the thermostat cover. 5 Power up the thermostat. 3 Use the connectors provided to connect the thermostat wires to the wires in the electrical box. Use the screws to secure the thermostat to the electrical box. Three-wire installation Electrical panel L2 N/L1 White - Neutral/Line 1 Red - Load Black - Line 2 Make sure to firmly tighten the wire connectors for a secure connection. A loose connection can be a fire hazard. 3/4" To install wire connectors, you must: 1 Insert the two wires into the wire nut so that their copper ends are parallel. 2 Turn the wire connector clockwise until there is strong tension. 3 Pull on the threads to make sure they are secure, leaving no gaps between them. * If the threads seem to come loose, repeat the process. * Improperly installed electrical wires could burn the wire connectors. To control a ductless air conditioner and heat pump unit, you will need to install an HP6000ZB series controller. ADD YOUR THERMOSTAT TO THE GT130 GATEWAY AND NEVIWEB 1 If you do not have an account yet, download the Neviweb app for iOS or Android to create an account and add your device. Get the app CONNECT YOUR THERMOSTAT TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM 1 Initiate the connectivity session by pressing the RF signal button on the GT130 gateway. The indicator light will start flashing. Compatible Zigbee gateway: refer to the installation guide for the latter. 2 Tap , then select "Add Device". 3 Follow the steps of the installation wizard. 3 Connect all your devices the same way, by going to the next closest device. 3rd 1st 2nd Hub 2 Connect your thermostat to the network by pressing brieffly and simultaneously on the and buttons. The thermostat will start searching for a network to join. Once the connection is complete, a connexion confirmation will appear on the screen. "Failure" will appear on the display if the connection fails. Refer to our Website to troubleshoot the unit. 4 When all your devices are connected, close the connectivity session of your GT130 gateway or your compatible Zigbee gateway. DISCONNECT YOUR THERMOSTAT FROM THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM CONFIGURATION MENU 1 To disconnect your thermostat To customize the settings in the from the GT130 gateway or a configuration menu, you must: compatible Zigbee hub, press the button for 10 seconds to access the "Diagnostics" menu. 1 Press the button for 5 seconds to access the configuration menu. 2 Swipe down on the touch control until the desired parameter appears on the screen. 3 Swipe down on the touch 3 Toggle between the different settings control until "Factory reset" by using the and buttons. Wait appears on the screen. for 4 seconds for your selection to be Swipe down confirmed or confirm it automatically by down to another menu screen. Transmitter Module IC: IC: 5123A-GM210P / FCC ID: QOQGM210P This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device does not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Configuration menu 3-year limited warranty SINOPÉ TECHNOLOGIES INC. warrants the components of their products against # Parameter Settings Default defects in material and workmanship for a 3 year period from the date of purchase, 3 Then simultaneously hold the and buttons for 1 Language choice French English English under normal use and service, when proof of purchase of such is provided to the manufacturer. This warranty does not cover any transportation costs that may be incurred by the consumer. Nor does it cover a product that has been improperly 10 seconds. installed, misused or accidentally damaged. The obligation of Sinopé Technologies 2 Cycle length 15 sec 15 min 15 sec Inc., under the terms of this warranty, will be to supply a new unit and this releases the manufacturer from paying the installation costs or other secondary charges linked to replacing the unit or the components. 3 Temperature unit Celcius Celcius Fahrenheit Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc. 660-1512-0001-A For more information, visit our Website: