Installation Guide for sinop models including: TH1134ZB, TH1134ZB-HC, TH1134ZB Smart Line Voltage Thermostat, TH1134ZB, Smart Line Voltage Thermostat, Line Voltage Thermostat, Voltage Thermostat, Thermostat

660-1512-0001-A Instruction sheet-TH1134Z-HC-ANG web

[PDF] 660-1512-0001-A Instruction sheet-TH1134Z-HC-ANG websupport.sinopetech.com › 2024/04

660-1512-0001-A Instruction sheet-TH1134Z-HC-ANG web

Installationguide

ation - Sinope Support


File Info : application/pdf, 2 Pages, 589.48KB

PDF preview unavailable. Download the PDF instead.

660-1512-0001-A-Instruction-sheet-TH1134Z-HC-ANG web
YOUR TH1134ZB HC THERMOSTAT

TECHNICAL SPECIFICATIONS

TH1134ZB/HC
Installation Guide
Smart Line Voltage Thermostat

Full-color display Touch-sensor buttons
Touch control

Operatlng voltage: 120 / 208 / 240 Vac, 60 Hz
TH1134ZB/HC Thermostat Maximum load: 16.7 A / 2000 W @ 120 Vac 16.7 A / 4000 W @ 240 Vac Resistive load only. Minimum load: 1.25 A / 300 W @ 240 Vca 1.25 A / 150 W @ 120 Vca
Cooling setpoint range: 61°F to 86°F (16°C to 30°C) Heating setpoint range: 41°F to 86°F (5°C to 30°C) Display range: 32°F to 99°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Operation: 32°F to 122°F (0°C to 50°C) Resolution: ± 0.5°C (± 1°F)
Protocol: Zigbee 3.0 Frequency: 2.4 GHz Transmission power: +20 dBm Receiver sensitivity: -108 dBm
Compatible with an electric heating system such as: · Baseboard heater [short cycle] · Convector [short cycle] · Fan-forced convector [long cycle) · Radiant ceiling heating · Ductless air conditioners and heat pumps
units with the HP6000ZB series controller*
* Scan the QR code to view the list of compatible devices or visit www.support.sinopetech.com/en/1.1.29.3/

Warnings
The installation of this thermostat must be performed by a certified electrician and comply with the national and local electrical codes and regulations.

Special CO/ ALR solderless connectors must be used when connecting with aluminum conductors.

INSTALL YOUR THERMOSTAT

1 Make sure that the breakers for your heating system are off at the main electrical panel.
4 Replace the cover and lock.

2 Unlock and lift the thermostat cover.
5 Power up the thermostat.

3 Use the connectors provided to connect the thermostat wires to the wires in the electrical box. Use the screws to secure the thermostat to the electrical box.

Three-wire installation

Electrical panel
L2 N/L1

White - Neutral/Line 1 Red - Load Black - Line 2

Make sure to firmly tighten the wire connectors for a secure connection. A loose connection can be a fire hazard.
3/4" To install wire connectors, you must:
1 Insert the two wires into the wire nut so that their copper ends are parallel.
2 Turn the wire connector clockwise until there is strong tension.
3 Pull on the threads to make sure they are secure, leaving no gaps between them. * If the threads seem to come loose, repeat the process.
* Improperly installed electrical wires could burn the wire connectors.

To control a ductless air conditioner and heat pump unit, you will need to install an HP6000ZB series controller.

ADD YOUR THERMOSTAT TO THE GT130 GATEWAY AND NEVIWEB
1 If you do not have an account yet, download the Neviweb app for iOS or Android to create an account and add your device. Get the app

CONNECT YOUR THERMOSTAT TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM
1 Initiate the connectivity session by pressing the RF signal button on the GT130 gateway. The indicator light will start flashing.
Compatible Zigbee gateway: refer to the installation guide for the latter.

2 Tap , then select "Add Device". 3 Follow the steps of the installation wizard.

3 Connect all your devices the same way, by going to the next closest device.
3rd 1st
2nd Hub

2 Connect your thermostat to the network by pressing brieffly and simultaneously on the and buttons.
The thermostat will start searching for a network to join.
Once the connection is complete, a connexion confirmation will appear on the screen.
"Failure" will appear on the display if the connection fails. Refer to our Website to troubleshoot the unit.
4 When all your devices are connected, close the connectivity session of your GT130 gateway or your compatible Zigbee gateway.

DISCONNECT YOUR THERMOSTAT FROM THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM

CONFIGURATION MENU

1

To disconnect your thermostat

To customize the settings in the

from the GT130 gateway or a

configuration menu, you must:

compatible Zigbee hub, press the button for 10 seconds to access the "Diagnostics" menu.

1 Press the button for 5 seconds to access the configuration menu.

2 Swipe down on the touch control until the desired parameter appears on the screen.

3

Swipe down on the touch

3 Toggle between the different settings

control until "Factory reset"

by using the and buttons. Wait

appears on the screen.

for 4 seconds for your selection to be

Swipe down

confirmed or confirm it automatically by down to another menu screen.

Transmitter Module IC: IC: 5123A-GM210P / FCC ID: QOQGM210P
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device does not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.

Configuration menu

3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the components of their products against

#

Parameter

Settings

Default

defects in material and workmanship for a 3 year period from the date of purchase,

3

Then simultaneously hold the and buttons for

1

Language choice

French English

English

under normal use and service, when proof of purchase of such is provided to the manufacturer. This warranty does not cover any transportation costs that may be incurred by the consumer. Nor does it cover a product that has been improperly

10 seconds.

installed, misused or accidentally damaged. The obligation of Sinopé Technologies

2

Cycle length

15 sec 15 min

15 sec

Inc., under the terms of this warranty, will be to supply a new unit and this releases the manufacturer from paying the installation costs or other secondary charges linked to replacing the unit or the components.

3

Temperature unit

Celcius

Celcius

Fahrenheit

Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc.

660-1512-0001-A