User Guide for VigorSwitch models including: G1282 Web Smart Managed Switch, G1282, Web Smart Managed Switch, Smart Managed Switch, Web Managed Switch, Managed Switch, Smart Switch, Switch
8 giorni fa — Before using the switch, perform the following steps: 1. Set up a physical path between the configured the switch and a PC by a qualified UTP Cat.
5 sept. 2022 — Before using the switch, perform the following steps: 1. Set up a physical path between the configured the switch and a PC by a qualified UTP Cat.
File Info : application/pdf, 8 Pages, 431.71KB
DocumentDocumentVigorSwitch G1282 Web Smart Managed Switch Quick Start Guide Version: 1. 1 Firmware Version: V2. 8. 0 (For future update, please visit DrayTek web site) Date: September 5, 2022 1 1. Package Content VigorSwitch G1282 (without PoE) Quick Start Guide Rack Mount Kit (brackets) The t ype of t he power cord depends on t he count ry t hat t he swit ch will be inst alled. UK-type Power Cord EU-type Power Cord USA/Taiwan-type Power Cord AU/NZ-type Power Cord If any of t hese it ems is f ound missing or damaged, please cont act your local supplier f or replacement . 2 2. Panel Explanation RJ45 (LNK/ ACT) Port 1 t o Port 24 Combo Port s SFP (LNK/ ACT) LED St at us On (Green) SYS Bl i nki ng ( Gr een) Of f PWR RJ45 (LNK/ ACT) Port 1 ~ 24 On (Green) Of f On (Green) Bl i nki ng Combo Port s 25 ~ 28 and SFP (LNK/ ACT) Of f On (Green) Bl i nki ng Of f Int e r f ace RJ 45 LNK/ ACT Port 1 ~ 24 SFP LNK/ ACT Port 25 ~ 28 Explanat ion The swit ch f inishes syst em boot ing and t he syst em is ready. The swit ch is powered on and st art s syst em boot ing. The power is of f or t he syst em is not ready / malf unct ioning. The device is powered on and running nor m al l y. The device is not ready or is f ailed. The device is connect ed The syst em is sending or receiving dat a t hrough t he port . The port is disconnect ed or t he link is f ailed. The device is connect ed The syst em is sending or receiving dat a t hrough t he port . The port is disconnect ed or t he link is f ailed. De scr ipt ion Port 1 t o Port 24 are used f or Et hernet connect ion. Port 25 t o Port 28 are used f or f iber connect ion. Power inlet f or AC input (100~240V/ AC, 50/ 60Hz). 3 3. Hardware Installation Bef ore st art ing t o conf igure t he swit ch, you have t o connect your devices correct ly. 3. 1 Network Connection Use t he Et hernet cable(s) t o connect None-PoE devices t o t he Vigor swit ch. All device port s are in t he same local area net work. 3. 2 Rack-Mounted Installation The swit ch can be inst alled easily by using rack mount kit. 1. Fast en t he rack mount kit on bot h sides of t he VigorSwit ch using specif ic screws. 2. Then, inst all t he VigorSwit ch (wit h rack mount kit ) on t he 19-inch chassis by using ot her f our scr ew s. 4 4. Software Configuration Bef ore using t he swit ch, perf orm t he f ollowing st eps: 1. Set up a physical pat h bet ween t he conf igured t he swit ch and a PC by a qualif ied UTP Cat . 5e cable wit h RJ-45 connect or. If a PC direct ly connect s t o t he swit ch, you have t o set up t he same subnet mask f or PC and t he swit ch. Def ault values of t he managed swit ch are list ed as f ollows: IP Address Subnet Mask DHCP Client User nam e Passw or d 192. 168. 1. 224 255. 255. 255. 0 Enabled (On) adm i n adm i n 2. Af t er conf iguring correct IP address on your PC, open your web browser and access swit ch's IP address. 5 The home page of VigorSwit ch will be shown as below: Customer Service If t he swit ch cannot work correct ly af t er t rying many ef f ort s, please cont act your dealer f or f urt her help right away. For any quest ions, please f eel f ree t o send e-mail t o support @drayt ek. com. Be a Registered Owner Web regist rat ion is pref erred. You can regist er your Vigor rout er via ht t ps: / / myvigor. drayt ek. com. Firmware & Tools Updates Due t o t he cont inuous evolut ion of DrayTek t echnology, all swit ches will be regularly upgraded. Please consult t he DrayTek web sit e f or more inf ormat ion on newest f irmware, t ools and document s. ht t ps: / / www. drayt ek. com GPL Notice This DrayTek product uses sof t ware part ially or complet ely licensed under t he t erms of t he GNU GENERAL PUBLIC LICENSE. The aut hor of t he sof t ware does not provide any warrant y. A Limit ed Warrant y is of f ered on DrayTek product s. This Limit ed Warrant y does not cover any sof t ware applicat ions or programs. To download source codes please visit : ht t p: / / gplsource. drayt ek. com GNU GENERAL PUBLIC LICENSE: ht t ps: / / gnu. org/ licenses/ gpl-2. 0 Version 2, June 1991 For any quest ion, please f eel f ree t o cont act DrayTek t echnical support at support @drayt ek. com f or f urt her inf ormat ion. 6 EU Declaration of Conformity We DrayTek Corp. , office at No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan , R.O.C., declare under our sole responsibility that the product Product name: 24+4 Gigabit Combo Switch Model number: VigorSwitch G1282 Manufacturer: DrayTek Corp. Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan is in conformity with the relevant Union harmonisation legislation: EMC Directive 2014/30/EU , Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU with reference to the following standards Standard EN 55032 EN 61000-3-2 EN 61000-3-3 EN 55035 EN 62368-1 EN IEC 63000:2018 Version / Issue date 2015+A11:2020 class A 2019 2013+A1:2019 2017+A11:2020 2014+A11:2017 2018 Hsinchu (place) June 16, 2021 (date) Calvin Ma / President . (Legal Signature) Declaration of Conformity We DrayTek Corp. , office at No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan , R.O.C., declare under our sole responsibility that the product Product name: Model number: Manufacturer: 24+4 Gigabit Combo Switch VigorSwitch G1282 DrayTek Corp. Address: Importer: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan CMS Distribution Ltd: Bohola Road, Kiltimagh, Co Mayo, Ireland is in conformity with the relevant UK Statutory Instruments: The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032) with reference to the following standards: Standard EN 55032 EN 61000-3-2 EN 61000-3-3 EN 55035 EN 62368-1 EN IEC 63000:2018 Version / Issue date 2015+A11:2020 class A 2019 2013+A1:2019 2017+A11:2020 2014+A11:2017 2018 Hsinchu (place) 16th June, 2021 (date) 7 Calvin Ma / President . (Legal Signature) Copyrights Trademarks Safety Instructions Warranty © Al l right s reserved. This publicat ion cont ains inf ormat ion t hat is prot ect ed by copyright . No part may be reproduced, t ransmit t ed, t ranscribed, st ored in a ret rieval syst em, or t ranslat ed int o any language wit hout writ t en permission f rom t he copyright holders. The f ollowing t rademarks are used in t his document : Microsof t is a regist ered t rademark of Microsof t Corp. Windows, 8 , 10, 11 and Explorer are t rademarks of Microsof t Corp. Apple and Mac OS are regist ered t rademarks of Apple Inc. Ot her product s may be t rademarks or regist ered t rademarks of t heir respect ive manuf act urers. Read t he inst allat ion guide t horoughly bef ore you set up t he swit ch. The swit ch is a complicat ed elect ronic unit t hat may be repaired only be aut horized and qualif ied personnel. Do not t ry t o open or repair t he swit ch yourself . Do not place t he swit ch in a damp or humid place, e. g. a bat hroom. Do not st ack t he swit ches. The swit ch should be used in a shelt ered area, wit hin a t emperat ure range of +5 t o +40 Cel si us. Do not expose t he swit ch t o direct sunlight or ot her heat sources. The housing and elect ronic component s may be damaged by direct sunlight or heat sources. Do not deploy t he cable f or LAN connect ion out door t o prevent elect ronic shock hazards. Keep t he package out of reach of children. When you want t o dispose of t he swit ch, please f ollow local regulat ions on conservat ion of t he environment . We warrant t o t he original end user (purchaser) t hat t he swit ch will be f ree f rom any def ect s in workmanship or mat erials f or a period of t wo (2) years f rom t he dat e of purchase f rom t he dealer. Please keep your purchase receipt in a saf e place as it serves as proof of dat e of purchase. During t he warrant y period, and upon proof of purchase, should t he product have indicat ions of f ailure due t o f ault y workmanship and/ or mat erials, we will, at our discret ion, repair or replace t he def ect ive product s or component s, wit hout charge f or eit her part s or labor, t o what ever ext ent we deem necessary t ore-st ore t he product t o proper operat ing condit ion. Any replacement will consist of a new or re-manuf act ured f unct ionally equivalent product of equal value, and will be of f ered solely at our discret ion. This warrant y will not apply if t he product is modif ied, misused, t ampered wit h, damaged by an act of God, or subj ect ed t o abnormal working condit ions. The warrant y does not cover t he bundled or licensed sof t ware of ot her vendors. Def ect s which do not signif icant ly af f ect t he usabilit y of t he product will not be covered by t he warrant y. We reserve t he right t o revise t he manual and online document at ion and t o make changes f rom t ime t o t ime in t he cont ent s hereof wit hout obligat ion t o not if y any person of such revision or changes. Regulatory Information Federal Communicat ion Commission Int erf erence St at ement This equipment has been t est ed and f ound t o comply wit h t he limi t s f or a Class A digit al device, pursuant t o Part 15 of t he FCC Rules. These limit s are designed t o provide reasonable prot ect ion against harmf ul int erf erence in a resident ial inst allat ion. This equipment generat es, uses and can radiat e radio f requency energy and, if not inst alled and used in accordance wit h t he inst ruct ions, may cause harmf ul int erf erence t o radio communicat ions. However, t here is no guarant ee t hat int erf erence will not occur in a part icular inst allat ion. If t his equipment does cause harmf ul int erf erence t o radio or t elevision recept ion, which can be det ermined by t urning t he equipment of f and on, t he user is encouraged t o t ry t o correct t he int erf erence by one of t he f ollowing measures: Reorient or relocat e t he receiving ant enna. Increase t he separat ion bet ween t he equipment and receiver. Connect t he equipment int o an out let on a circuit dif f erent f rom t hat t o which t he receiver is connect ed. Consult t he dealer or an experienced radio/ TV t echnician f or help. This device complies wit h Part 15 of t he FCC Rul es. Operat ion is subj ect t o t he f ollowing t wo condit ions: (1) This device may not cause harmf ul int erf erence, and (2) This device may accept any int erf erence received, including int erf erence t hat may cause undesired operat ion. USA Local Represent at ive Company name Addr ess ZIP Code Cont act Person ABP Int ernat ional Inc. 13988 Diplomat Drive Suit e 180 Dallas TX 75234 75234 E- m ai l rmesser@abpt ech. com Mr. Robert Messer Tel. 19728311600 Caut ion: Any changes or modif icat ions not expressly approved by t he part y responsible f or compliance could void t he user's aut horit y t o operat e t he equipment . More updat es, please visit www. drayt ek. com. 8