
Instruction Manual for TRUE NORTH models including: TN20 Wood Burning Fireplace Insert, TN20, Wood Burning Fireplace Insert, Burning Fireplace Insert, Fireplace Insert
True North TN20 Wood Burning Fireplace Insert — Luxa Lifestyle
TN20 Wood Insert by True North - Groupe BelleFlamme
File Info : application/pdf, 28 Pages, 1.29MB
DocumentDocumentIMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS SERIAL # SAFETY NOTICE If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area. Meets the U.S. Environmental Protection Agency's May 2020 Cribwood Particulate Emission Standards 290523-28 Model: TN20 INSERT Series: B TN20B INSERT 100000127 Contents Specifications ............................................................................ 3 Efficiency and BTU Output................................................. 3 Safety and Maintenance ............................................................ 4 Maintenance Checks ................................................................. 5 Weekly:............................................................................... 5 Monthly ................................................................................ 5 As Needed.......................................................................... 5 When Cleaning the Chimney System:................................ 5 Blower: ............................................................................... 5 Chimney Smoke and Creosote Formation......................... 6 Chimney Fires .................................................................... 6 Avoid a Chimney Fire ......................................................... 6 In the event of a Chimney Fire ........................................... 7 Wood Selection .................................................................. 7 DO NOT BURN:.................................................................. 7 Operation ................................................................................... 8 Lighting a Fire..................................................................... 8 Normal Operation............................................................... 8 Restarting After Extended or Overnight Burns .................. 9 Heat Output........................................................................ 9 Proper Draft........................................................................ 9 How to Test Your Wood...................................................... 9 Curing of the Paint Finish................................................. 10 Ash Removal .................................................................... 10 Disposal of Ashes............................................................. 10 Blower Operation ............................................................. 10 Stove Dimensions ................................................................... 11 Clearance to Combustibles ..................................................... 11 Minimum Clearances to Combustibles ............................ 11 Fireplace Hearth requirements ................................................ 12 Fireplace Installation ................................................................ 13 Crate Removal ................................................................. 13 Minimum Fireplace Dimensions ....................................... 14 Full Flue Liner - (Required in Canada).............................. 15 Direct Flue Connection - (USA only) ............................... 16 Combustion Air ................................................................ 17 Leveling Legs ................................................................... 17 Surround Assembly and Installation ........................................ 18 Baffle Board / Tube Installation ............................................... 19 Removal ........................................................................... 19 Installation ........................................................................ 19 Blower ..................................................................................... 20 Blower Maintenance / Removal ....................................... 20 Electrical Supply............................................................... 21 Firebrick Installation ................................................................ 22 Troubleshooting ....................................................................... 23 Parts Diagram .......................................................................... 24 Label ........................................................................................ 25 ! WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the True North, TN20 INSERT Series B wood heater. This heater meets the 2020 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 13,931 to 29,208 Btu/hr. NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN THE AREA WHERE THE HEATER IS TO BE INSTALLED. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open. Do not disconnect the detectors. SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. 2 ©PACIFIC ENERGY FIREPLACE TN 20B INSERT PRODUCTS LTD. 290523-28 Specifications Efficiency and BTU Output EPA Certified Emissions LHV Tested Efficiency 1 HHV Tested Efficiency 2 EPA BTU Output 3 Peak BTU/Hr Output 4 Maximum Wood Length Ideal Wood Length Fuel 1.6 grams per hour 78% 72.7% 13,900 to 29,200 btu/hr 55,000 20 inches 18 inches Seasoned Cord wood 1 Weighted Average Lower Heating Value (LHV) efficiency as tested using CSA B415 Performance testing of solid-fuelburning heating appliances. LHV assumes the moisture is already in a vapour state so there is no loss of energy 2 Weighted Average Higher Heating Value (HHV) efficiency as tested using CSA B415 Performance testing of solid-fuelburning heating appliances. HHV includes the energy required to vaporize the water in the fuel 3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid-fuel-burning heating appliances and burn rates from the low and high EPA tests using Douglas Fir dimensional lumber. 4 The Peak BTU/hr is based on efficiency using CSA B415 Performance testing of solid-fuel-burning heating appliances, the Maximum one hour High burn rate from the High Burn EPA test and the BTU content of cord wood (8600 btu/lb). Experience will give you the right settings for proper combustion and efficient burning for the wood you are using. Remember the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With practice, you will become proficient in operating your heater and will obtain the performance for which it was designed. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 3 PRODUCTS LTD. Safety and Maintenance WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil. WARNING: ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS. 1. Burn only dry and well seasoned cord wood. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or unseasoned wood, do so only with the air inlet set open enough to maintain a good strong fire and fairly high chimney temperatures. Do not attempt to burn overnight using green wood or wet wood. Wet wood can cause up to 25% drop in heater output, as well as contributing significantly to creosote buildup. 2. Remove ashes frequently. Embers can roll out the door and create a fire hazard. Maintain a 1"(25mm) minimum ash base. 3. If glass becomes darkened through slow burning or poor wood, it can readily be cleaned with fireplace glass cleaner when stove is cold. Never scrape with an object that might scratch the glass. The type and amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up at least as quickly in the chimney. 4. DOOR GASKETS - The gasket used for the True North (5/8"(16mm) medium density fiberglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition. Periodically inspect seals and replace if necessary. Follow instructions included in the Gasket kit obtainable from your nearest True North dealer. 5. DOOR GLASS - Do not slam loading door or otherwise impact glass. When closing door, make sure that no logs protrude to impact the glass. If the glass gets cracked or broken, it must be replaced before using the stove. Replacement glass can be obtained from your dealer. Use 9-1/4"(235mm) x 13-1/4"(337mm) x 5 mm. Ceramic glass only. Do not substitute with any other type. · -To remove broken glass, undo the four retaining screws and remove clamps, noting position for re-assembly. Remove all particles of glass. Be careful as they are very sharp. Replace Gasket if damaged. Install new glass. Replace clamps and screws. CAUTION: - do not overtighten, tighten screws very carefully - do not clean glass when hot - do not use abrasive cleaners on glass 6. The openings for combustion air must be kept clear of excessive ash buildup which will block air flow. This area is at the front of the firebox or at your fresh air intake. 7. Do not store wood within heater installation clearances, or within the space required for fuel loading and ash removal. Keep the area around the heater clean and free of loose combustibles, furniture, newspapers, etc. 4 ©PACIFIC ENERGY FIREPLACE TN 20B INSERT PRODUCTS LTD. 290523-28 8. Establish a routine for the fuel, wood burning and Lighting techniques. Check daily for creosote buildup in the firebox, until you are experienced and are operating the stove cleanly and safely. 9. Be aware that the hotter the fire, the less creosote is deposited. More frequent chimney cleaning may be necessary in mild weather or when burning "wet" or unseasoned wood. 10. Instruct all members of your family on the safe operation of the heater. Ensure they have enough knowledge of the entire system if they are expected to operate it. Stress the section on chimney fires and the importance of following the steps outlined "In Case of Chimney Fire". Maintenance Checks Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: Weekly: · Firebrick - Visual, for cracking. · Door Gasket - sagging, placement, damage. Monthly · Brick rail tabs and brick rails. · Back side of airwash chamber. · Boost tube opening. · Top baffle boards. · Baffle Tubes. As Needed · It is recommeded that the chimney be inspected a minimum of every 2 months and cleaned as needed a minimum of 2 times a year. When Cleaning the Chimney System: · Top heat shield and mounting bolt. · Brick Rails. · Manifold. - Replace the baffle tubes if they show signs of cracking or breakage. - Please contact your Dealer for replacement parts if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and will void your warranty Blower: · The blower should be cleaned out a minimum every six months by using a vacuum on the inlets, grills and around the motor to remove any dust and debris. See page 20 for instructions. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 5 PRODUCTS LTD. Chimney Smoke and Creosote Formation When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected periodically (at least once every two months) during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated (3 mm. or more), it should be removed to reduce the risk of a chimney fire. · Highest smoke densities and emissions occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed off too quickly. Smaller fuel loads, (two or three logs at a time) and leaving the air inlet relatively wide open, especially during the first 10 to 30 minutes after each loading, when most of the smoke generating reactions are occurring will promote smoke-free, clean burning. After 30 minutes or so, the air inlet can be turned down substantially without excessive smoke generation. · Wet or green wood contributes significantly to creosote formation as the excess moisture that is boiled off, cools the fire, making it difficult for the tars and gases to ignite, thus creating dense smoke and poor combustion. This moisture-laden smoke cools the chimney, compounding the problem. In summary, a certain amount of creosote is inevitable. Regular inspection and cleaning is the solution. The use of dry, seasoned wood and ample combustion air will help to minimize annoying smoke emissions and creosote buildup. Chimney Fires The dangerous side effect of excessive creosote buildup is a chimney fire. This causes much higher than normal temperatures in the chimney and on its exterior surfaces. Temperatures inside the chimney can exceed 2000°F (1100°C). Ignition of nearby or touching combustible material is more likely during a chimney fire. Proper clearances are critical to prevent damage during such a fire. Chimney fires are easy to detect; they usually involve one or more of the following: · Flames and sparks shooting out of the top of the chimney · A roaring sound · Vibration of the chimney · Avoid a Chimney Fire 1. Burn wood cleanly. Do not burn wet wood or turn down the unit too quickly after loading. 2. Do not let creosote build up to a point where a chimney fire is possible. 3. Do not have fires in the heater that may ignite chimney fires. These are excessively hot fires, such as when burning household trash, cardboard, Christmas tree limbs, or even ordinary fuel wood; (e.g. With a full load on a hot bed of coals and with the air inlet wide open for more time than is needed to completely char a fresh fuel load.) 4. The Chimney and connector pipe should be inspected /cleaned periodically. 6 ©PACIFIC ENERGY FIREPLACE TN 20B INSERT PRODUCTS LTD. 290523-28 In the event of a Chimney Fire Have a fire extinguisher handy. Contact your local, Municipal or State/Provincial fire authority for further information on how to handle a chimney fire. It is most important that you have a clearly understood plan on how to handle a chimney fire. 1. Close down the air inlet on the stove. 2. Call the local fire department. 3. Prepare to evacuate to ensure everyone's safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet. 4. After the chimney fire is out, the chimney must be cleaned and checked for stress and cracks before starting another fire. Also check combustibles around the chimney and the roof. The services of a competent or certified installer, (certified by the Wood Energy Technical Training program (WETT) - in Canada, National Fireplace Institute (NFI) - in U.S.A., are strongly recommended. Wood Selection This heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. Wood should be properly air dried (seasoned) for six months or more. Wet or unseasoned wood will cause the fire to smoulder and produce large amounts of smoke and creosote. Wet wood also produces very little heat and tends to go out often. Wood should be stored under cover away from open flame or heat sources. DO NOT BURN: · Salt water wood * · Treated wood · Wet or green wood · Coal/charcoal · Garbage* · Solvents · Lawn clippings/yard waste · Unseasoned wood · Railroad ties · Manure or animal remains · Materials containing rubber, including tires · Materials containing plastic · Waste petroleum products, paints or paint thin- · Materials containing asbestos ners, or asphalt products · Construction or demolition debris · Paper products, cardboard, plywood, or particleboard. * These materials contain chlorides which will rapidly destroy metal surfaces and void warranty. Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause excessive smoke. The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in an affected wood heater. Do not burn anything but cordwood. Other fuels, e.g. Charcoal, can produce large amounts of carbon monoxide, a tasteless, odourless gas that can kill. Under no circumstances should you attempt to barbecue in this heater. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 7 PRODUCTS LTD. Operation CAUTION: Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. WARNING: Always keep loading door closed when burning. This heater is not designed for open door burning. Risk of sparks, embers and/or smoke coming from the unit. WARNING: No alteration or modification of the combustion air control assembly is permitted. Any tampering will void warranty and could be very hazardous. WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on the fire bricks. Replace broken or missing bricks. Failure to do so may create a hazardous condition. WARNING: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or `freshen up' a fire in this heater. Keep all such liquids well away from the heater while in use. Lighting a Fire ** Remove the retaining clip on the front of the Baffle Tubes and Board before lighting for the first time. 1. Move air control lever to the left-most position (maximum firing rate) and open door. 2. Place crumpled newspaper in the centre of the heater and criss-cross with several pieces of dry kindling. Add a few small pieces of dry wood on top. 3. Ignite the paper and leave the door ajar approximately 1/2"(13mm) - 1"(25mm) until the wood kindling is fully engulfed in flame. DO NOT LEAVE UNATTENDED. 4. After the kindling is fully engulfed add a few small logs. Close door. 5. Begin normal operation after a good coal base exists and wood has charred. Normal Operation 1. Set air control to a desired setting. If smoke pours down across the glass (waterfall effect) this indicates you have shut the control down too soon or you are using too low a setting. The wide range control panel makes finding the desired setting for your application easy. As every home's heating needs vary (i.e. Insulation, windows, climate, etc.) the proper setting can only be found by trial and error and should be noted for future burns. 2. To refuel, adjust air control to high, and give the fire time to brighten. Open the door slowly, this will prevent back puffing. 3. Use wood of different shape, diameter and length (up to 18" (457mm)). Load your wood and try to place the logs so that the air can flow between them. Always use dry wood. 4. Do not load fuel to a height or in such a manner that would be hazardous when opening the door. 5. For extended or overnight burns, unsplit logs are preferred. Remember to char the wood completely on maximum setting before adjusting air control for overnight burn. 8 ©PACIFIC ENERGY FIREPLACE TN 20B INSERT PRODUCTS LTD. 290523-28 WARNING: This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with the operating instructions in this manual. Restarting After Extended or Overnight Burns 1. Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door. 2. Adjust air control to high (control lever to the left) and in just a few minutes, logs should begin burning. 3. After wood has charred, reset air control to desired setting. 4. To achieve maximum firing rate, set air control lever to the left-most position. Do not use this setting other than for starting or preheating fresh fuel loads. DO NOT OVERFIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney. Your True North heater is designed for maximum overall efficiency at a moderate firing rate. Over firing the appliance will shorten the life of the product. Failure to rectify an over firing condition can be hazardous and may void the manufacturer's warranty. Too slow a burn may contribute to creosote buildup and lowers combustion efficiency. Heat Output Experience will give you the right settings for proper combustion and efficient burning. Remember that the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With practice, you will become proficient in operating your heater and will obtain the performance for which it was designed. Proper Draft Draft is the force that pulls air into the appliance and up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. · Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. · Inadequate draft may cause back puffing into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft. How to Test Your Wood Add a large piece of wood to the stove when it has a good large bed of coals. It is dry if it is burning on more than one side within one minute. It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting in five minutes it is soaked and should not be burned. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 9 PRODUCTS LTD. Curing of the Paint Finish To achieve the best finish, the paint on your stove must be baked on. Follow the Paint Curing instructions. When burning your stove for the first 2-3 times it is very important that the room be well ventilated. Open all windows and doors. Smoke and fumes caused by the curing process may cause discomfort to some individuals. Ash Removal Caution: Ashes are to be removed only when the heater is cold. Whenever ashes get 3"(76mm) to 4"(102mm) deep in your firebox, and when fire has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the firebox bottom to help maintain a hot charcoal bed. Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed outside on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container. Blower Operation The Insert comes equipped with a variable speed circulating air blower. The Blower Control is located on the lower right side edge of the Surround panel. To operate the blower, rotate the fan speed control clockwise to turn ON then continue to rotate to find a desired setting. Suggested settings: - Combustion air control setting of "Low"(all the way to the right), operate blower speed control on "Low". - Combustion air control greater than "Low", operate blower speed control at desired setting To turn OFF rotate the knob counterclockwise past the "click" Figure1:TN20.INSA.fan controls. 10 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 6 1/4" [159mm] 18 5/8" 473mm 17 7/8" 455mm Stove Dimensions 38" 965mm 25 1/8" 640mm 21 1/2" 546mm 20 1/8" 511mm 19 7/8" 505mm 27" 686mm 12 5/8" 321mm Figure2:TN20 INSB 3 view dimensions. Clearance to Combustibles 21 3/8" 543mm Mantel or Top Facing MINIMUM 54" FROM BASE OF UNIT TO CEILING SIDE FACING AND ADJACENT WALL MEASURED FROM SIDE OF STOVE 15" 380mm MANTEL DISTANCE MEASURED FROM TOP OF FIREBOX Side Facing AdWjaaclel nt 12" 305mm 8 1/2" 216mm Hearth Figure3:TRNO 20 INSERT CLEARANCES. Minimum Clearances to Combustibles The minimum required clearances to surrounding combustible materials when installed into a masonry or factory built fireplace are listed below and in Fig. #2. Adjacent Sidewall*........................................12 in.(305 mm) Side Facing*..............................................8 1/2 in.(216 mm) *(Measured from side of stove) Mantel / Top Facing (Measured from firebox top).......................15 in.(380 mm) Ceiling. (From base of the unit)..................................54 in.(1.37m) 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 11 PRODUCTS LTD. Fireplace Hearth requirements In Canada - The Masonry Fireplace's Hearth must extend a minimum of 16"(406mm) in front and 8"(203mm) beyond each side of the fireplace opening and can be flush with adjacent combustible floor. MINIMUM EMBER PROTECTION DIMENSIONS Non-combustible Fireplace Hearth 22 7/8" 581mm *Non-combustible Ember Protection 18" 450mm 16" 406mm * Ember protection: Figure4:flush ember protection TRNO 20 insert. In CANADA, Combustible floor in front of the fireplace insert must be protected from hot embers by non- combustible material extending 18"(450mm) to the front/firing side and 8" (200mm) to sides of the unit. Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, In the U.S. - the Masonry Fireplace's Hearth must extend a minimum of 16" in front and 8" beyond each side of the fireplace opening and be raised 1" above a combustible floor, or the hearth must extend a minimum of 21"in front and 8" beyond each side of the fireplace opening and can be flush with a combustible floor. Non-combustible Fireplace Hearth **Non-combustible Ember Protection 16" 16" 21" Non-combustible hearth Flooring Min. 1" drop Flooring Figure5:US 2in Drop hearth TRNO 20 insert **Ember protection: Figure6:US flush hearth TRNO 20 insert Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible material extending 16"(457mm) in the U.S. to the front/firing side and 8" to sides of the unit. Consult N.F.P.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA. 12 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 Fireplace Installation Your Insert is designed to be installed into an approved masonry wood fireplace. The masonry fireplace must be built according to the requirements of the Standard of Chimneys, Fireplaces, Vents and Solid Fuel Burning appliances, N.F.P.A. 211 (Latest Edition) or applicable National, Provincial, State or local codes. In Canada, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. This Insert shall not be installed in a factory-built fireplace. Warning: Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. · DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. · DO NOT INSTALL IN A SLEEPING ROOM. · THIS ROOM HEATER MUST BE CONNECTED TO A CODE APPROVED MASONRY CHIMNEY WITH A LISTED FLUE LINER. · DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION DUCT. · Outside combustion air or fresh air into the room may be required in your area, consult local building codes (see Combustion Air section). We recommend that our products be NATIONAL FIREPLACE INSTITUTE installed and serviced by professionals who are certified in the U.S. by the; NFI(National Fireplace Institute) or Wood Energy Technical Training www.wettinc.ca CSIA (Chimney Safety Insitute of America or in Canada by; WETT (Wood Energy Technical Training) or APC (Association des Professionnels du Chauffage CERTIFIED www.nficertified.org Crate Removal 1. Carefully remove wood top and supports. 2. Remove plastic cover. · Remove the retaining clip on the front of the baffle before lighting for the first time 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 13 PRODUCTS LTD. Minimum Fireplace Dimensions Your fireplace is required to have the following minimum sizes: WIDTH at the front 29" (737 mm) HEIGHT 20 1/4" (514 mm) WIDTH at the back 22" (560 mm) DEPTH 18" (457 mm) Recommended Minimum Chimney height: 15'(4.5m) If installed at less than recommended height, starting and or operating problems may occur. 20 1/4" 514mm 22" 560mm 18" 457mm 29" 737mm 8" 203mm ** Non-combustible Fireplace hearth 8" 203mm ** CANADA: 16" (406mm) USA: 16" deep at a height of 1" above combustible flooring or 21" deep at combustible floor height Figure7:Fireplace specs. Into a Masonry Fireplace Inspect your fireplace for cracks, loose mortar or other physical defects. If repairs are required, they should be completed before installing your insert. The fireplace chimney must be suitable for wood burning use. Check for creosote build up or other obstructions, especially if it has not been in use for some time. The existing fireplace damper is to be locked open or removed completely. Have the chimney cleaned to prevent odours and possible fires. WARNING: Do not remove bricks or mortar from your existing fireplace. Exception: Masonry or steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner, provided that their removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for combustible materials to less than that required by the National Building Code. 14 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 The Insert must be installed in accordance with local and or national building codes. The two methods of flue connection that are acceptable in most areas are shown on page 15 and 16. A metal tag is provided and is to be fastened to the back wall of the fireplace, if the fireplace has been modified to accommodate the insert. Pacific Energy highly recommends the use of a full liner as the safest installation and providing optimum performance. When connected to a full liner, the Insert is able to draft correctly and will help prevent problems such as difficult start-ups and smoking out the door. Consult your local Dealer about codes and installation. Full Flue Liner - (Required in Canada) A listed stainless steel rigid or flexible liner extends from the Insert flue collar to the top of the chimney. In Canada, this Fireplace Insert must be installed with a continuos chimney liner of 6 inch diameter extending from the Fireplace Insert to the top of the chimney. The chimney liner must conform to the class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys. 1) Measure the chimney height from the top of the existing flue to the floor of the hearth. This will allow extra length of liner for flashing and rain cap. 2) Feed the stainless steel liner from top of the chimney, through the damper area and into the fireplace cavity. 3) Attach a stove connector to the bottom of the liner, as per the instructions provided with the chimney liner. 4) Push the Insert into position inside the fireplace and attach the connector to the stove collar and secure with screws. Use the rear adjusting legs to level the Insert. 5) Measure, trim and shape a top flashing to fit the existing chimney flue. Plan for a 1" to 1-1/2" overlap on each side. Place flashing over top of the liner and seat firmly against the tile. Screw flashing collar to liner. Caulk gap around flashing with RTV silicone. 6) Attach a rain cap to the end of the liner. A storm collar may be used if desired. Full Flue Liner Rain Cap 6" Stainless Steel Rigid or Flex Liner Mantel or Top Facing Figure8:Fulliner TRNO 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 15 PRODUCTS LTD. Direct Flue Connection - (USA only) A listed stainless steel rigid or flexible liner extends from the Insert flue collar to the first masonry chimney flue liner. A seal must be provided in the throat. Note: A clean-out door may be required under local codes, when a direct flue connection is used. Consult local codes. Direct Flue Connection 1) Measure from the first chimney flue liner to the top of the Insert. Allow extra length of liner to insert into flue tile. 2) Feed the stainless steel liner through the damper area and into the first chimney flue tile. Seal around pipe to the chimney, using non-combustble materials . Seal Flex Liner into Chimney 6" Stainless Steel Rigid or Flex Liner Note: A clean-out door may be required under local codes, when a direct flue connection is used. Consult local codes. 3) Attach a stove connector to the bottom of the liner, as per the instructions provided with the chimney liner. 4) Push the Insert into position inside the fireplace and attach the connector to the stove collar and secure with screws. Figure9:US Direct Flue TN 20 insert. Chimney Flue Liner 16 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 Combustion Air Consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the Insert in one of two ways: 1) Outside air supply: Remove cover from ash clean out in existing fireplace. Place a rodent screen in place of the cover. Install the Insert as described in the "Installation" section, making sure not to cover the opening of the air inlet. 2) Room air supply: Remove the cover plate beneath the ash lip by removing the two screws securing it to the unit base. The unit must have adequate air for combustion provided in the room the unit is installed in. This may involve providing make up air from outside the house. ROOM AIR Opening Figure10:room air opening. Leveling Legs Use the Leveling leg bolts provided, Screw the legs into the Nuts provided in the base bottom to stabilize the unit on uneven surfaces. Leveling Bolt Figure11:TN20B Insert Leveling Bolt. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 17 PRODUCTS LTD. Surround Assembly and Installation 1. Remove the shipping screws located at the top of each surround side panel (fig. 10). remove the two screws holding the Fan Controls on the side panel and remove the controls (fig.12). Lift to remove both panels from the unit. Shipping screw Figure 12: TN20.INSA Shipping screw 2. Unpack the top panel and lay parts A, B and C face down on a flat, non-marking surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points "D" (Fig. #11). 3. Lift the surround assembly to the upright position and make sure the front face is flat and even at the joints. D Part A D Part C Part B Figure 13: TRNO20 SURROUND ASSEMBLY 4. Move the assembled surround around the stove. Locate and engage the panels hooks onto the pins located on the surround brackets. Push down to lock. 5. Attach the fan controls to the inside of the right side panel using the two screws installed in the Fan Control Mounting Plate (See Page 20). 6. Push the entire appliance back until the back of the surround assembly is in contact with the fireplace facing. CAUTION: DO NOT LET THE WIRES CONTACT THE FIREBOX OR THE MOUNTING PLATE, AS THEY MAY MELT. 18 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 Baffle Board / Tube Installation The Chimney liner should be disconnected from the Insert to clean and inspect the chimney. Only if this is not possible should you remove Baffle Boards. DO NOT OPERATE WITH BAFFLE BOARD INSULATION OR TUBES REMOVED. Removal 1. With a set of vise-grips, grasp the front baffle tube on the right, slightly away from the baffle air assembly. While squeezing tightly, use a hammer to hit the pliers and pull the tube to the right to disengage the tube from the hole on the left. Allow the tube to hang freely from the hole on the right. 2. Repeat step #1 for second baffle tube. 3. Grasp the front edge of the left half of the baffle board and tilt up at the back. Guide the board down and through the door opening. 4. Grasp the right half of the baffle board and slide it over to the left. 5. Tilt the back of the board up and guide it down and through the door opening. Installation 1. Insert one half of baffle board above the two back baffle tubes inside the firebox, slide over to the right and allow to rest on the baffle air assembly. 2. Ensure that the second half is inserted to allow the two cuts in the baffle boards to overlap. Insert the other half of the baffle board and allow to rest on the left side baffle air assembly. 3. With the holes facing forward and the notch to the left side, insert a baffle tube into the hole in the baffle air channel on the right then slide to the left and insert into the opposite hole on the left side baffle air assembly. Align the notch in the tube with the tab in the hole. 4. With a set of vise-grips, grasp the baffle tube on the left, slightly away from the baffle air assembly. While squeezing tightly, use a hammer to hit the pliers and push the tube to the left to engage the tube in the hole on the left. 5. Repeat steps #3 & #4 with the remaining baffle tube. 6. Slide the baffle board halves together and then separate slightly to ensure there are no gaps on either outer side of the baffle board. 7. Push baffle board tight against the rear of the firebox. 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 19 PRODUCTS LTD. Blower Maintenance / Removal Blower The blower requires annual cleaning to remove buildup on the blades. More frequent cleaning may be required if room conditions are dusty or you have pets. The cleaning of the Blower can be done easily by the homeowner but we recommend having this done by a qualified service technician who can inspect the entire unit at the same time. To get access to the blower follow step 1 then gently vacuum any dust and hair from the blower inlets and motor. 1. Remove the surround by lifting to disengage the securing hooks at the top and bottom of the surround sides and pulling towards the front of the unit. (Fig. #14) 2. Using a Torx T20 Screwdriver, remove the Blower Control from the side panel. 3. With a 3/8" socket, remove the two bolts securing the blower mounting assembly to the unit. (Fig. #15) Figure14:surround removal. Mounting bolts Figure15:TN20.INSA.fan controls. Figure16:TN20 INSB Fan and Casing removal . 20 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 4. Pull the blower assembly and controls off of the stove. 5. Remove the four screws securing the blower cover to the blower bracket. 6. Remove the three nuts securing the blower to the mounting bracket and replace the blower. (Fig. #17) Install the new blower by reversing the steps. Blower mounting nuts Figure17:TN20.INSA.fan removal 2. Electrical Supply Circulating air blower electrical rating: 115V, 0.5A 60 Hz. For your protection against shock hazard, use only a properly grounded outlet that will accept a three-pronged plug. Do not cut or remove the grounding prong. Consult local codes or in the absence of local codes, with the current CSA C22.2 Canadian Electrical Code and in the USA with the National Electrical Code, ANSI/NFPA 70 (latest edition). 290523-28 Fan controller Blower Figure18:TN20 INS Wiring dia. TN 20B INSERT Ground power cord ©PACIFIC ENERGY FIREPLACE 21 PRODUCTS LTD. Firebrick Installation The package contains 20 full-size firebricks. With the insert in its final position, install the firebricks as follows: 1. Place the first brick up under the rear brick rail and slide it to either the far left or far right (Figure 19). 2. Place 3 more bricks up under the rear brick rail to complete the rear brick placement (Figure 20). Brick rails Figure 19: Firebox and brick rails. 3. Place the floor bricks as shown in Figure 21. Figure 20: Bricks against rear wall. 4. On both the right and left sides, place the first side wall brick under the Brick Retainer and on top of the floor bricks and slide it all the way to the back, so that it is up against the rear wall bricks. 5. Using the same method, place three more bricks along one of the side walls. (Figure 22) 6. Repeat the side wall brick installation on the opposite side to complete the firebrick installation. Figure21:Floor bricks laying lengthwise. 22 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. Figure22:Remaining side wall bricks installation. TN 20B INSERT 290523-28 Problem Glass is Dirty Cause Troubleshooting Cure 1. Wood is wet - Use dry wood 2. Turning down air control or damper too soon - Do not turn down until a) there is a good bed of coals b) the wood is charred 3. Draft too low - Improper chimney height and / or diameter - Chimney plugged or restricted, check flue - Provide outside air for combustion 4. Door gasket leakage - Replace gasket - Check latch - If bent, consult dealer. Excessive Creosote Buildup - See 1, 2, 3, above. Low Heat Output 1. Wood is wet 2. Fire too small 3. Draft too low - Use dry wood - Build a larger fire - Chimney plugged or restricted, inspect and clean Won't Burn Overnight 1. Air control is set too high - Set control lower 2. Not enough wood - Unsplit wood is preferred for overnight burns 3. Draft too high - Excessive chimney height and/or diameter, See "Your True North heater is designed for maxi- mum overall efficiency at a moderate firing rate. Over firing the appliance will shorten the life of the product. Failure to rectify an over firing condition can be hazardous and may void the manufacturer's warranty. Too slow a burn may contribute to creosote buildup and lowers combustion efficiency." on page 9. Stove Won't Burn 1. Combustion air supply blocked 2. Draft too low - Check outside air supply for obstruction - Check that room air cover is removed - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 23 PRODUCTS LTD. Parts Diagram DESCRIPTION........................................ PART NO. 1......... Baffle Board (2pcs.) ......................................................... 80000619 2......... Baffle Tube Set(4pcs.)...................................................... 80000615 3a....... Baffle Airbox, Left (c/w gasket/screws) ........................... 80002140 3b ...... Baffle Airbox, Right (c/w gasket/screws)......................... 80002141 3c....... Baffle Air Box, Gasket with Screws (1 side) .................... 80002138 4......... Rear Brick Rail ................................................................. 80002143 5......... Door Casting Assy - No Glass (c/w Handle).................... 80000621 6......... Door and Glass Gasket ................................................... 80000600 7......... Replacement Glass (c/w clamps/gasket) ........................ 80000616 8......... 4pc. Glass Clamps (c/w screws) .................................... 80000617 9......... Firebrick Set 9"x4 1/2"x1 1/4"(20pcs.) ............................ 80000620 10....... Flameshield (c/w hardware)............................................. 80002142 12....... Power Cord...................................................................... 80000911 13....... Fan................................................................................... 80000905 14....... Fan Speed Controller....................................................... 80000908 14b .... Fan Speed Control Knob ................................................. 80001509 15....... Fan Control Decal............................................................ 80002061 16....... Surround, Series B .......................................................... 80002311 Parts can be obtained from your local Pacific Energy dealer using these part numbers. OPTIONS: Surround Extension Set .............................................................. 31250001 Oversized Trimable Backing Plate Set ........................................ 31120002 4 3a 3b 2 16 8 6 1 7 5 10 12 13 14 15 9 11 Figure23:TN20B INS Exploded Parts View. 24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 Label LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE MODEL / MODÈLE: TN20 INSERT SERIES / SÉRIE: B CERTIFIED FOR USE IN CANADA AND U.S.A./CERTIFIE AU CANADA ETL# 4001507 CERTIFIED TO / CERTIFIÉ POUR: CAN/ULC 628 and UL1482 Refer to Intertek's Directory of Building Products for detailed information · · · · · · · · · · INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY'S INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. E INSTALL AND USE ONLY IN MASONRY FIREPLACE. NOT TO BE INSTALLED IN A FACTORY-BUILT FIREPLACE. L DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. COMPONENTS REQUIRED FOR INSTALLATION : IN CANADA - FULL FLUE LINER CONFORMING TO CAN/ULC-S635 OR CAN/ULC-S640. P - IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT FLUE CONNECTION ASSEMBLY. ELECTRICAL RATING 115V, 60HZ, 0.6 AMP. ROUTE POWER CORD AWAY FROM UNIT. DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. M FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE-BUILD WOOD FIRE DIRECTLY ON HEARTH. A REPLACE GLASS ONLY WITH CERAMIC GLASS. INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY.OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. S STOVE DESIGNED TO BURN CORDWOOD ONLY. BURNING OTHER MATERIALS MAY CAUSE DAMAGE TO STOVE OR HOME. · THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. · CONSULT THE OWNER'S MANUAL FOR FURTHER INFORMATION. · IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL MINIMUM CLEARANCE TO COMBUSTIBLES / DÉGAGEMENT AUX MINIMUM AUX COMBUSTIBLES: (MEASURED FROM SIDE OF UNIT MESURES DE L'OUVERTURE DE PORTE) A) ADJACENT SIDEWALL/ 419 MM / 16 1/2 IN MUR LATÉRAL ADJACENT B) SIDE FACING/ COLONNE LATÉRALE 330 MM / 13 IN D C ADJACENT SIDE WALL / MUR LATERAL ADJACENT (MEASURED FROM INSERT FIREBOX TOP / MESURES DU DESSUS DU CAISSON) C) TOP FACING/ 381 MM / 15 IN GARNITURE SUPÉRIEURE D) MANTEL / MANTEAU 381 MM / 15IN A B (MEASURED FROM INSERT FIREBOX FRONT / F MESURES DU DEVANT DU CAISSON) E) CANADA: FIRING SIDE / FACE DE CHARGEMENT 457 MM / 18 IN U.S.A.: FIRING SIDE*, (E.-U) 406 MM / 16 IN @ 1" ABOVE COMBUSTIBLE FLOOR * F) OTHER SIDES / FACES LATERALES 200 MM / 8 IN E F TYPE 1 FLOOR PROTECTION APPROVED TO UL1618, MINIMUM 20GA STEEL MUST BE USED ADJACENT TO THE HEARTH. · INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D'INSTALLATION ET D'UTILISATION DE PACIFIC ENERGY. · CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE, CONCERNANT LES CODES, RESTRICTIONS ET · EXIGENCES D'INSPECTION D'INSTALLATION APPLICABLES À VOTRE RÉGION. · INSTALLER ET UTILISER UNIQUEMENT DANS LE FOYER DE MAÇONNERIE. NE PAS INSTALLER DANS UN FOYER FABRIQUÉ EN USINE. · NE RACCORDEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL. · COMPOSANTS REQUIS POUR L'INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE CONFORME À CAN/ULC-S635 OU CAN/ULC-S640. AUX ETATS-UNIS : GAINE DE CHEMINÉE CONFORME À UL-1777 OU KIT DE GAINE CHEMINÉE À RACCORDEMENT DIRECT. · ALIMENTATION ÉLECTRIQUE : 115V, 60HZ, 1,1 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE DE L'APPAREIL. · DANGER : RISQUE D'ÉLECTROCUTION. COUPEZ L'ALIMENTATION ÉLECTRIQUE AVANT TOUT TRAVAIL D'ENTRETIEN SUR L'APPAREIL. · POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. N'UTILISEZ AUCUN PORTEBÛCHES SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS DIRECTEMENT SUR L'ÂTRE. · REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. · INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - DANS · CERTAINES CONDITIONS, DES DÉPÔTS DE CRÉOSOTE PEUVENT SE FORMER RAPIDEMENT. · UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. · CE POÊLE EST CONÇU UNIQUEMENT POUR BRÛLER DU BOIS DE CORDE. BRÛLER D'AUTRES MATÉRIAUX PEUT CAUSER DES DOMMAGES MATÉRIELS AU POÊLE OU AU BÂTIMENT. · CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L'OBJETD'ENTRETIENS ET D'INSPECTIONS PÉRIODIQUES POUR UN FONCTIONNEMENT ADÉQUAT. CONSULTEZ LE MANUEL D'UTILISATION POUR PLUS D'INFORMATION. DATE OF MANUFACTURE U.S. ENVIRONMENTAL PROTECTION AGENCY. Certified to comply with 2020 crib wood particulate emission standards, using test Method 28R 1.6 g/hr MANUFACTURED BY: PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 ALLENBY RD., DUNCAN, BC V9L 6V8 MADE IN CANADA 050523 100001348 TN20INS-B 290523-28 TN 20B INSERT ©PACIFIC ENERGY FIREPLACE 25 PRODUCTS LTD. 26 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. TN 20B INSERT 290523-28 290523-28 TN 20B INSERT Printed in Canada ©PACIFIC ENERGY FIREPLACE 27 PRODUCTS LTD. © 2023 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Web site: www. truenorthstoves.com 2975 Allenby Rd., Duncan, BC V9l 6V8 Printed in Canada