
Instruction Manual for AJAX models including: ETHT82 White Touch Screen Thermostat, ETHT82, White Touch Screen Thermostat, Touch Screen Thermostat, Screen Thermostat, Thermostat
Ajax White Touch Screen Thermostat | Underfloor Heating
V2.2 INSTALL Thermostat Instruction Easy touch Easy warm APP for WiFi thermostat Table of Contents 01 Thermostat descripon 01 02 Main funcons 01 03 Technical specificaon 01 04 Display symbols 02 05 WiFi connecon(Only for WiFi thermostat) 03 06 Funcon & User operaon 05 07 Troubleshoong 13 08 Dimension 13 09 Installaon and wiring instrucons 14 THERMOSTAT DESCRIPTION The TOUCH WHITE series is a smart thermostat used to control your electric floor heang system or water heang system. It will keep your home at comfortable temperature whilst minimizing energy use. Install the app on your smart phone to control your electric heang system remotely with the WiFi thermostat. MAIN FUNCTIONS Auto mode Floor temperature limit Holda mode Open window detecon funcon Holiday mode Key-lock Sensor selecon An-frozen funcon Brightness Adapve funcon TECHNICAL SPECIFICATION Supply voltage: 85-265Vac 50/60Hz Standby power: 2W IP rang: IP20 Max load: 16A(electric heang)/3A(water heang) Wire diameter: 2.5mm² DISPLAY SYMBOLS Time Hold Mode Detected Temp Menu WiFi / Heat / Event / Floor Sensor Increase Decrease 8*'*$0//&$5*0/*0/ Step 3: Click `Add Device' or `+' on the top-right to add device. Step 2: Register and log in with mobile number/email address in the APP. Aenon: Please read and agree `Privacy Policy and Service agreement' before registraon. Step 1: Scan the QR code or download the Warmme from APP store/ Google browser. Step 4: Click `WiFi thermostat' Step 5: Operate thermostat. If the WIFI icon flash quickly, Click `Press to connect'. Step 6: Enter Wifi password, and click `Confirm'. Aenon: If failed, confirm the Wifi is 2.4G version and check the Wifi signals, then, use the `AP mode' in the top right to connect again. Step 7: If device added successfully, change the device name and set region. Then, click `Done'. Step 8: You can check the actual temperature and set temperature etc. at the control interface. FUNCTION & USER OPERATION On/Off Press the buon ont the right side of the thermostat to turn on/off. Note: When an-frozen funcon is acve, the thermostat will maintain the an-frozen temperature when power off. Temporarily override temperature In the page of detected temperature, press or to change the current event temperature seng. The thermostat will revert to the parameters of schedule at the start-me of the next event in auto mode. Mode selecon In the page of detected temperature, press the key in the up le corner to select the mode. There are 3 modes: Auto mode: It is the default mode. Thermostat runs according to event parameters set in Edit Seng to save energy. Steps: Press Auto Mode to confirm and back to the page of detected temperature. Manual mode: Thermostat will run with the set temperature for ever. Steps: Press Manual Mode to enter temperature seng. Press or to set the temperature. Press to confirm and enter the page of detected temperature. Holiday mode: Thermostat will run with the set temperature unl the holiday me ends. Steps: Press Holiday Mode to enter holiday seng. Press or to set the days of holiday. Press to confirm and enter holiday temperature seng. Press or to set the temperature. Press to confirm and enter the page of detected temperature. Menu In the page of detected temperature, press the key There are 5 parameter sengs. to enter Menu. 1. Time Day and clock are set here. Steps: Press Time to enter day seng. Press the day you want to enter hour seng. Press or to set hour. Press to confirm and enter minute seng. Press or to set minute. Press to confirm and back to Menu. Press to back to the page of detected temperature. * If the thermostat is WiFi version, it will update me automacally aer connecng to WiFi. 2. Key lock Lock all keys to prevent the sengs from being changed. Lock Steps: Press Key Lock to enter key lock seng. Press or to select lock. Press to confirm and back to the page of detected temperature. Unlock steps: In the page of detected temperature, press any key then will flash 3 mes. Press and hold for 3 seconds to unlock. (in the down right corner) 3. Brightness This opon allows you to change the brightness of the display. Steps: Press Brightness to enter brightness seng. Press to move up/down or touch any part of the line to set the brightness. Press to confirm and back to Menu. 4.Edit seng Edit seng can set and change the parameters. If you don't choose Holiday Mode or Hold Mode. The thermostat runs according to the parameters of Edit. Steps: Press Edit Seng to enter days selecon. Press the day you want to set. Press to enter event selecon. Press the event you want to set and enter the start me hour seng. Press or to set start me hour. Press to confirm and enter the start me minute seng. Press or to set start me minute. Press to confirm and enter temperature seng. Press or to set temperature. Press to confirm and back to event selecon. Press some mes to back to the page of detected temperature. Default parameters Day Mon-Fri Sat/Sun Wake 07:00 22.0°C 08:00 22.0°C Leave 08:30 19.0°C 08:30 22.0°C Back 17:00 22.0°C 17:00 22.0°C Sleep 22:00 19.0°C 22:00 19.0°C 5. Advanced Seng The thermostat provides advanced sengs to suit various special situaons. These are normally set by technicians during inial installaon. Steps: Press Advanced Seng to enter the page of warning. Press to enter the page of advanced seng. Press or to switch page. Press the item to set its parameters. No. Name 1 Room Temperature Calibraon 2 Floor Temperature Calibraon 3 An-frozen Switch 4 An-frozen Temperature 5 Floor Temperature Limit 6 Temperature Tolerance 7 Temperature Unit 8 Sensor Selecon 9 Schedule 10 Output Delay Default 0°C 0°C ON 5°C 30°C 1°C °C Floor 5+1+1 0 Sec Ranges -5°C -- 5°C -5°C -- 5°C ON/OFF 5°C -- 15°C 20°C -- 50°C 0.5°C/1°C/2°C/3°C °C/°F Room/Floor/Both 5+1+1/7 0S/30S/60S/90S PARAMETER No. Name Default Ranges 11 Adapve Funcon OFF ON/OFF 12 Open Window OFF ON/OFF 13 Power Set 0 W 0W -- 4500W 14 Energy Use 15 Sensor Type 0-3950 0-3950 1-3380 2-3700 3-3600 4-3740 16 Factory Reset NO NO/YES 1. Room Temperature calibraon: Calibrate the temperature detected by room sensor. 2. Floor Temperature calibraon: Calibrate the temperature detected by floor sensor. 3&4. An-frozen funcon: If the An-frozen funcon opened, it will keep the room and floor at a lower temperature in order to protect the pets and plants in your house. Also, it can protect your pipe against freezing when using the water heang system. 5. Floor temperature limit: When choose both sensors, you can set the maximum floor temperature value, system will stop heang if the floor temperature exceed this value. PARAMETER 6. Temperature Tolerance: The value is 1°C. The thermostat start to work when the actual temp is 1°C lower than set temp and stop to work when the actual temp is 1°C higher than set temp. 7.Temp unit: °F and °C can be selected. 8:Sensor selecon Room sensor: Run by room sensor. Floor sensor: Run by floor sensor. Both sensors: Run by room sensor with floor temp limit. 9. Schedule: Select a weekly schedule for the event. 7: each day from Mon to Sun can be set individually. 5+1+1: Mon to Fri have the same events, Sat and Sun can be set individually. 10. Output delay: This opon help you avoid inadvertent operaon on heang. 11. Adapve funcon: Aer several days of installaon and use, Adapve funcon ensures that the required temp has already been reached when the next event begins. 12. Open window: This funcon only works when room sensor or both sensors is selected. The thermostat with this funcon will shut off automacally for 15 min when the window opens, as it can detect that the room temp plummets. 13&14. Energy use: This opon allows you to enter the various data used to calculate energy use. 15.Sensor Type: This thermostat is compable with the following five floor temperature sensors. The default sensor 0-3950 is in the box. Temperature The resistance value of the floor sensor at the corresponding temperature point () 0-3950 1-3380 2-3700 3-3600 4-3740 0 °C 10 °C 32800 19733 26050 17630 30286 19055 34423 22217 34720 22328 25 °C 10000 10000 10000 12000 12000 30 °C 7905 8331 8165 9869 9854 16. Factory Reset: All parameters are restored to default values. TROUBLESHOOTING Room Sensor Error! : Built-in sensor short-circuit or disconnected. Floor Sensor Error! : Floor sensor short-circuit or disconnected. DIMENSION (MM) INSTALLATION AND WIRING INSTRUCTIONS Installaon Separate the panel from the back secon: insert the screwdriver into two holes under the thermostat and pry it like the picture. Connect the wire as shown in the wiring instrucon. Step 1 Step 2 NOTE: The 82 series thermostat should be mounted in a standard 86 type switch box. Fix the back secon to switch box with screws provided. Re-install front panel whilst ensuring the pins engage properly in the circuit board socket. Step 3 Step 4 Wiring instrucons POWER FLOOR SENEOR NN11 NN L LL11 S2 CSOEMNSOSR1 POWER 85V-265V 50/60Hz MAX LOAD: 16A FLOOR SENSOR IP 21 Suggeson: Please keep the max load around 90% of 16A to prolong the lifeme. Cauon: Ensure power is disconnected when wiring! 16Adobe Illustrator CC 22.1 (Windows) iLovePDF