User Guide for Danfoss models including: 101N08xx Series, 101N08xx Series BD Controller, 101N08xx Series, BD Controller
File Info : application/pdf, 24 Pages, 5.03MB
DocumentDocumentMAKING MODERN LIVING POSSIBLE BD Controller 101N08xx Series 12-24 V DC with Tool4Cool® LabEdition software and Danfoss Bluetooth® gateway Quick Start Guide Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 2 DEHC.PS.100.P2.02 Quick Start Guide Contents BD Controller 101N08xx Series 12-24 V DC 1. Checklist.................................................................................................................................4 2. Connect cables 2.1 Single compressor configuration, 12 V DC or 24 V DC ....................................6 2.2 Twin compressor configuration, 12 V DC or 24 V DC ......................................7 3. Pairing the gateway 3.1 Windows XP ....................................................................................................................8 3.2 Windows Vista ............................................................................................................ 11 4. Install software................................................................................................................ 15 5. Install Product Key......................................................................................................... 17 6. Connect network ............................................................................................................ 18 7. Ready to operate ............................................................................................................ 21 8. Ordering ............................................................................................................................. 22 9. Further information ...................................................................................................... 23 DEHC.PS.100.P2.02 3 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 1. Checklist Check that you have the following: BD Controller 101N08xx Series 12-24 V DC (modules and cables) Image shows compressor/application modules 101N08xx-series in twin compressor configuration with communication cable asembly Tool4Cool® LabEdition software installation CD Product key for BD compressor controller DH3TT6RBAD1GW8G68ZM1N8G62ZMCOO916IER6GH2YZEIR DC line cords NTC temperature sensor (alternative: mechanical thermostat) Danfoss Bluetooth® gateway USB power supply Bluetooth® communication cable Ordering: See section 7.0 4 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 2. Connect cables Legend for 2.1 & 2.2 A) Application module 101N0820 B) Compressor module 101N0800, 12 V DC / compressor module 101N0810, 24 V DC C) Line cords D) Single or twin compressor communication cable assembly 1) Mounting screws 2) Battery 3) Fuse 4) Main switch 5) Evaporator fan 6) Condenser fan 7) Mechanical thermostat 8) NTC temperature sensor (electrical thermostat), alternative: mechanical thermostat 9) NTC auxiliary temperature sensor 10) Compressor(s) 11) Danfoss One Wire/LIN gateway communication interface 12) Modbus-compatible device 13) Danfoss Bluetooth® gateway communication interface See Intructions DEHC.EI.100.V. for details. DEHC.PS.100.P2.02 5 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 2.1 Single compressor Connect cables as shown: configuration, 12 V DC or 24 V DC Wiring diagram 6 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 2.2 Twin compressor configuration, 12 V DC or 24 V DC Connect cables as shown: Wiring diagram DEHC.PS.100.P2.02 7 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 3. Pairing the gateway 3.1 Windows XP In order to communicate, Bluetooth® devices must first be paired. Pairing is performed before using the device for the first time. Pairing does not need to be repeated for subsequent use. Please choose the operative system installed on your computer. 1. Attach or turn on the Bluetooth® radio adapter (transceiver) for your Windows XP computer. 2. Turn on the Danfoss Bluetooth® gateway by pressing briefly on the push button. The LED will blink green. Please note!: The gateway runs for 30 seconds before shutting down automatically. At each step of the pairing process, check that the LED is still blinking. If one stage of the pairing fails, turn the gateway on again, and try again. 3. Open Bluetooth® Devices in Control Panel/Printers and Other Hardware (Category view) or Control Panel (Classic view). Control Panel Category View: Control Panel Classic View: 8 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 4. On the Devices tab, click Add. 5. Select the My device is set up and ready to be found check box, and then click Next. 6. Click on the Danfoss Bluetooth® gateway shown in the dialog, and then click Next. DEHC.PS.100.P2.02 9 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 7. Click Use the passkey found in the documentation, and then type the passkey: 1234. 8. Note the outgoing COM port, in this example COM 9. Then click Finish to complete pairing. 9. The COM port can also be viewed in the COM ports tab of the Bluetooth® devices dialog. Make a note of the Outgoing COM port (in this example, COM9): 10 DEHC.PS.100.P2.02 Quick Start Guide 3.2 Windows Vista BD Controller 101N08xx Series 12-24 V DC 1. Attach or turn on the Bluetooth® radio adapter (transceiver) for your Windows Vista computer. 2. Turn the Danfoss Bluetooth® gateway on by pressing briefly on the push button. The LED will blink green. Please note!: The gateway runs for 30 seconds before shutting down automatically. At each step of the pairing process, check that the LED is still blinking . If one stage of the pairing fails, turn the gateway on again, and try again. 3. Open Bluetooth® Devices in Control Panel/Hardware and Sound. 4. Select Add then OK. The wizard will open: 5. Check the Bluetooth® gateway is turned on. Click the box My device is set up and ready to be found. Select Next. The wizard will search... DEHC.PS.100.P2.02 11 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC ...and then display nearby Bluetooth® devices: 6. Select the Danfoss device, then select Next. 7. Enter the passkey 1234 as shown, then select Next. The wizard will perform these steps: 12 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 8. Select Finish to complete pairing. Now look at the Control Panel again, to confirm the Danfoss device is visible: 9. Select the Danfoss device, then select Properties as shown here: DEHC.PS.100.P2.02 13 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 10. Under the Services tab, make a note of the COM port to which the gateway is paired. In this example it is COM9: Alternatively, the COM port can be viewed in the COM ports tab of the Bluetooth® devices dialog. Make a note of the Outgoing COM port: 14 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 4. Install software 1. Check that you have the latest update of .NET Framework from www.windowsupdate.com. 2. Insert the Tool4Cool® installation CD. This view will appear: DEHC.PS.100.P2.02 15 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 3. Double-click on Tool4Cool® Software Installation. Run the file setup.exe. Then follow the instructions in the Setup Wizard. 1 2 3 4 5 16 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 5. Install Product Key 1. Start Tool4Cool® LabEditon by double clicking on the icon on the desktop: 2. Select Help in the menu bar. 3. Select Product Keys from the drop-down menu: 4. This dialog box will open: In the Add Product Key field, type the Product Key shown in Section 1: Checklist. Click on the Add Key button. The Product Key is now active. DEHC.PS.100.P2.02 17 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 6. Connect network 1. Select File in the menu bar. 2. Select Connect Network in the drop-down menu: 3. This dialog box will open: 18 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC In the Connect using field, select the COM port to which the gateway is connected. Note!: This is the COM port you noted down in section 3 Pairing the gateway. Fill in Description (optional). 4. Click on the Configure button: 5. The Configure Network dialog box will appear. Set the Last Network Node to 1. Set the Refresh Rate to 15: DEHC.PS.100.P2.02 19 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC Then press OK to return to the Connect Network dialog. 6. Check the gateway is turned on. In the Connect Network dialog, press OK. Wait a short time. A red arrow will appear in front of the description (COM/USB network). The controller is now accessible via Tool4Cool®. 20 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 7. Ready to operate Click on the red arrows to view the controller and its parameter groups: Click on a parameter group name to view details to the right of the screen: DEHC.PS.100.P2.02 21 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 8. Ordering Compressors Single-Pack Model BD350GH 12 V DC supply BD350/350GH 12 V DC supply - twin compressor BD350GH 24 V DC supply BD350/350GH 24 V DC supply - twin compressor BD220CL 12 V DC supply Code no 102Z3015 102Z3018 102Z3016 102Z3017 102Z3020 Description Compressor module 12 V DC Compressor module 24 V DC Application module 12 & 24 V DC 24 V DC line cord, 900 mm, 6mm2 24 V DC line cord, 2000 mm, 6 mm2 24 V DC line cord, 5000 mm, 6 mm2 Temperature sensor, 470 mm, spade connectors Temperature sensor, 1000 mm, spade connectors Temperature sensor, 1500 mm, spade connectors Danfoss One Wire/LIN gateway with cables & driver One Wire/LIN gateway communication cable Danfoss Bluetooth® gateway with power supply Bluetooth® gateway communication cable 101N0800 101N0810 101N0820 105N9542 105N9540 105N9538 105N9612 105N9614 105N9616 105N9501 105N9524 105N9502 105N9525 used together w. 101N0820 used together w. 101N0820 used together w. 101N800/810 accessories accessories accessories accessories accessories accessories accessories accessories (101N8xxx series) accessories accessories Compressor module 12 V DC 101N0801 Compressor module 24 V DC 101N0811 Application module 12 & 24 V DC 101N0821 Compressor communication cable assembly 1500 mm 105N9553 Compressor communication cable assembly 3000 mm 105N9554 Twin compressor communication cable assembly 800 mm 105N9561 Twin compressor communication cable assembly 1500 mm 105N9555 Twin compressor communication cable assembly 3000 mm 105N9556 12 V DC line cord, 900 mm, 8 mm2 105N9560 12 V DC line cord, 2000 mm, 8 mm2 105N9559 24 V DC line cord, 5000 mm, 6 mm2 105N9539 24 V DC line cord, 900 mm, 6mm2 105N9543 24 V DC line cord, 2000 mm, 6 mm2 105N9541 Temperature sensor, 470 mm, spade connectors 105N9613 Temperature sensor, 1000 mm, spade connectors 105N9615 Temperature sensor, 1500 mm, spade connectors 105N9617 Display cable assembly without fuse 1500 mm 105N9557 Display cable assembly without fuse 3000 mm 105N9558 30 pcs. 30 pcs. 24 pcs. 80 pcs. 45 pcs. 65 pcs. 65 pcs. 40 pcs. 40 pcs. 20 pcs. 36 pcs. 36 pcs. 36 pcs. 200 pcs. 100 pcs. 100 pcs. 65 pcs. 35 pcs. Tool4Cool® LabEdition, 1 license Tool4Cool® LabEdition, 2 license Tool4Cool® LabEdition, 5 license 105N9300 PC software, 1 licence version 105N9301 PC software, 2 licence version 105N9302 PC software, 5 licence version Industrial-Pack (I-Pack) Software Package 22 DEHC.PS.100.P2.02 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC 9. Further information For detailed installation and operation instructions, please refer to other literature, currently availabe from Danfoss: Title Tool4Cool® LabEdition Operating Instructions Tool4Cool® LabEdition Bedienungsanleitung (German) BD Controller 101N08xx Series 12-24 V DC with Tool4Cool® LabEdition software Operation Instructions BD Controller 101N08xx Series 12-24 V DC with Tool4Cool® LabEdition software and Danfoss One Wire/LIN gateway Quick Start Guide BD Controller 101N08xx Series 12-24 V DC with Tool4Cool® LabEdition software and Danfoss Bluetooth® gateway Quick Start Guide Danfoss Bluetooth® Gateway with Tool4Cool®LabEdition Operation Instructions Danfoss One Wire/LIN Gateway 105N9501 Instructions Compressor Module 101N0800, 12V DC Compressor Module 101N0810, 24V DC Application Module 101N0820, 12/24V DC Instructions 12V & 24V DC Line Cords for Application Module 101N0820 & Compressor Modules 101N0800/0810 Instructions Display Cable without Fuse for Application Module 101N0820 Cord Sets for 101N0820 & 101N0800/0810 Instructions Single Compressor Communication Cable Assembly for 101N0800/101N0810 & 101N0820 Cord Sets for 101N0820 & 101N0800/0810 Instructions Twin Compressor Communication Cable Assembly for 101N0800/101N0810 & 101N0820 Cord Sets for 101N0820 & 101N0800/0810 Instructions Temperature Sensors for BD350GH Electronic Unit Instructions Danfoss Literature Number DEHC.PI.300.B__.02 DEHC.PI.300.B__.03 DEHC.PS.100.M__.02 DEHC.PS.100.N__.02 DEHC.PS.100.P__.02 DEHC.PS.300.D__.02 DEHC.PI.100.K__.02 DEHC.EI.100.V__.02 DEHC.EI.100.E__.02 DEHC.PI.100.L__.02 DEHC.PI.100.M__.02 DEHC.PI.100.O__.02 DEHC.PI.100.G__.02 "__" = version number (changes) DEHC.PS.100.P2.02 23 Quick Start Guide BD Controller 101N08xx Series 12-24 V DC Danfoss Household Compressors GmbH · Mads-Clausen-Str. 7 · D-24939 Flensburg / Germany · Tel: +49 (0461) 4941-0 · compressors.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved DEHC.PS.100.P2.02/520N1071 Produced by Danfoss Compressors, DEHC6093, 08.2010