Installation Guide for kwhiq models including: IQ0304100d1, IQ0304100d1 Direct Connected Three Phase DIN Rail Meter, Direct Connected Three Phase DIN Rail Meter, Connected Three Phase DIN Rail Meter, Three Phase DIN Rail Meter, Phase DIN Rail Meter, DIN Rail Meter, Rail Meter, Meter
Direct connected 3-fase DINrail Meter - Xemex
File Info : application/pdf, 15 Pages, 3.00MB
DocumentDocumentInstallation Manual IQ0304100d1 > Direct connected Three Phase DIN rail Meter > 100 Amp MODbus meter > MID certified > Designed for submetering of electrical loads like EV-chargers, PV-Inverters with high Amps Contact www.kwhiq.com info@kwhiq.com +31 (0)73 544 3071 Installation Manual Version 1.0 IQ0304100d1 - meter Amendment Version 1.0 1.1 Date 06/03/2023 09/03/2023 Remark Draft Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 2 Installation Manual Version 1.0 IQ0304100d1 - meter Content Content 3 MID Certificate 4 Guidelines for safety and installation 5 Safety Instructions 5 Exclusion of liability 5 All Rights Reserved 5 For service and technical support information, please contact 5 Specifications 6 Electrical 6 Environmental 6 Dimensions 6 Wiring diagram 6 Display format 6 General description 7 Front view 7 Button instruction 7 LCD display 8 LCD Scrolling Display Page 8 LCD Information Display Page 9 Installation 10 Mounting 10 Electrical install procedure 11 Communication install procedure 11 Operation 12 Scrolling function 12 Set modbus parameters 12 Modbus registers (partly) 14 Contact information 15 Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 3 Installation Manual Version 1.0 IQ0304100d1 - meter MID Certificate Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 4 Installation Manual Version 1.0 IQ0304100d1 - meter Guidelines for safety and installation This installation guide must be consulted in all cases when manipulating parts which are marked with the Caution symbol. The installation and the operation of this device and any maintenance must be carried out by a qualified person in accordance with specific local standards and safety regulations. Failing to obey the "Guidelines for safety and installation", the guarantee no longer applies. Safety Instructions · Case is sealed, do not open the meter. No warranty if case is opened. · The meter should be installed indoor or in the outdoor electric meter box. · The meter is intended to be installed in a Mechanical Environment `M1', with Shock and Vibrations of low significance, as per 2014/32/EU Directive. · The meter is intended to be installed in Electromagnetic Environment `E2', as per 2014/32/EU Directive. Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions in the information given. The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions. If you have any suggestions, please let us know. All Rights Reserved No part of this document can be reproduced or transmitted in any form or by any means without prior written consent of KWHIQ B.V. Burgemeester Burgerslaan 40 5245 NH Rosmalen. The Netherlands. For service and technical support information, please contact: KWHIQ b.v. Burgemeester Burgerslaan 40. 5245 NH Rosmalen, E-mail: support@kwhiq.com, Website: https://kwhiq.com/ Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 5 Installation Manual Version 1.0 IQ0304100d1 - meter Specifications Electrical Accuracy Voltage Current Frequency Power consumption Pulse constant Active Reactive Rated Voltage Voltage with standard Operation voltage range Long-range voltage Rated current Starting current 50Hz ± 2% Voltage circuit Current circuit 1000 imp/kWh(kvarh) Class B Class 2 2x230(400)V 440V 80% to 120% Un 58/100V to 240/415V 5(100)A 20mA 1W 12VA Environmental Operating temperature Operating humidity Dimensions -40 ° C to 70 ° C 75% RH (Max 95% RH) Storage temperature Case protection Display format -40 ° C to 70 ° C IP51 Indoor Wiring diagram Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 6 Installation Manual Version 1.0 IQ0304100d1 - meter General description Front view I Impulse indication for active energy J Impulse indication for reactive energy K Far IR L Button for data checking Q M Button for data setting N SO1 output for active energy (default) O SO2 output for reactive energy (default) I M P RS485 output Q LCD screen N J KO L P Button instruction Button Function Short Press: next page Long press: go to setup menu Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 7 Installation Manual Version 1.0 IQ0304100d1 - meter LCD display LCD Scrolling Display Page 20LCD Scrolling Display Page Page Content 1 Total active energy 2 Forward active energy 3 Reverse active energy 4 Total reactive energy 5 Forward reactive energy 6 Reverse reactive energy 7 First quadrant reactive energy 8 Second quadrant reactive energy 9 Third quadrant reactive energy 10 Fourth quadrant reactive energy 11 Active maximum demand 12 Forward active maximum demand 13 Reverse active maximum demand 14 Reactive maximum demand 15 Forward reactive maximum demand 16 Reverse reactive maximum demand 17 A phase and N-phase voltage 18 B phase and N-phase voltage 19 C phase and N-phase voltage 20 A Phase and B Phase line voltage 21 B Phase and C Phase line voltage 22 C Phase and A Phase Line Voltage 23 Current of A-phase 24 Current of B-phase 25 Current of C-phase 26 Combined active power 27 A-phase active power 28 B-phase active power 29 C-phase active power 30 Combined reactive power 31 A phase reactive power 32 C phase reactive power 33 Combined Apparent Power 34 A phase apparent power 35 B phase apparent power 36 C phase apparent power 37 Combined frequency 38 A phase frequency 39 B phase frequency 40 C phase frequency 41 Combined power factor 42 A phase power factor 43 B Phase power factor 44 C Phase power factor Unit kWh kWh kWh kWh kvarh kvarh kvarh kvarh kvarh kvarh kvarh kvarh kvarh kvarh kvarh kvarh V V V V V V I I I kW kW kW kW kvarh kvarh kvarh kVA kVA kVA kVA Hz Hz Hz Hz Hz Hz Hz Hz Long press the left button for more than 3 seconds to switch the display page: > Scroll display page > A-phase energy page > B-phase energy page > C-phase energy page > Information page > Scroll display page Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 8 Installation Manual Version 1.0 IQ0304100d1 - meter LCD Information Display Page LCD Information Display Page Page Content 1 12-digit serial number of the meter 2 Modbus communication address 3 Baud rate 4 Parity 5 Stop bit 6 Scrolling time 7 Combination code 8 Demand type & period 9 SO output Format 000000000000 1-247 6 = 9.600 7 = 19.200 8 = 38.400 9 = 115.200 0=None (default) 1=Odd 2=Even 1=1 bit (default) 2=2 bit 0-99 seconds 1-Total=forward 2-Total=reverse 3-Total =forward+reverse (default) 4-Total=forward-reverse 0=Interval 1=Slip Period=1-30 minutes 800, 1.000, 1.600, etc. above 100, divisible by 96.000 Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 9 Installation Manual Version 1.0 IQ0304100d1 - meter Installation CAUTION: · Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before working on it. · Always use a properly rated voltage sensing device to confirm that power is off. WARNING: · The installation should be performed by qualified personnel familiar with applicable codes and regulations. · Use insulated tools to install the device. · A fuse, thermal cut-off or single-pole circuit breaker should be fitted on the supply line and not on the neu- tral Mounting Mount the device in a DIN-rail cabinet Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 10 Installation Manual Version 1.0 IQ0304100d1 - meter Electrical install procedure 2.5 Nm (A) 0-32 32-65 65-100 (mm2) 1-6 10-14 16-25 (Nm) 0.9-1.2 1.5-2.0 2.0-2.5 Maximum cable size: : 25 mm2 Maximum screw torque: : 2.5 Nm Communication install procedure Maximum screw torque: 0.2 Nm: Maximum cable size: : 2.5 mm2 : 2.5 mm2 Wire the device in accordance to the Wiring Diagram. If the bare wire is visible above the terminal bridge, shorten the stripped part of the wire. Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 11 Installation Manual Version 1.0 IQ0304100d1 - meter Operation Scrolling function · Automatic scroll: Every 5 seconds the meter will display the next programmed data page (depending on the setting). · Button scroll: Each short press on the meter button will display the next programmed data page. Set modbus parameters By default, the modbus parameters are: Modbus id Baud rate Parity # Stop bits 1 9.600 None 1 Meter settings can be adjusted in two ways: · Manually through the use of the button and display page · Serially through Modbus commands (see Modbus registers). Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 12 Installation Manual Version 1.0 IQ0304100d1 - meter Manually adjusting meter settings 1. Navigate to the SETUP menu by long pressing the push button (see red circle). In the SETUP menu you can enter a PIN code. By long pressing the push button you can enter digits. Press briefly to adjust the value of the flashing digit. Use this method to enter the PIN code 0000. 01 100 14 SETUP 14Pin 0000 Default: standard mode SETUP menu Pincode 2. Check the following settings in the SETUP menu and change if necessary. Press long to adjust, press briefly to change variables. 01 1D 001 02 9600 03 None Modbus ID: unique per device on the bus Baud rate: default `9600' (19200/38400/115200) Parity: default `None' (odd/even) 04 STOP 1 Stop bit: default `1' Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 13 Installation Manual Version 1.0 IQ0304100d1 - meter 3. Long press the push button to navigate out of the SETUP menu. Configuration is complete. 04 QUIT QUIT Modbus registers (partly) A selection of the most important modbus registers: Page Serial Number E-meter Reg unit UNITLESS Modbus Reg Address (DEC) 4096 Modbus Reg Address (HEX) 0x1000 Modbus ID Forward Active Energy Reverse Active Energy Forward active Power Reverse active Power Instantaneous Voltage L1-N Instantaneous Voltage L2-N Instantaneous Voltage L3-N Instantaneous Voltage vector 1-247 kWh kWh Watt Watt Volt Volt Volt Volt Instantaneous Voltage Volt vector Instantaneous Current L1 Instantaneous Current L2 Instantaneous Current L3 Instantaneous Current vector Ampère Ampère Ampère Ampère 4099 0x1003 270 0x010E 280 0x0118 1056 0x0104 Negative Forward Power 1024 0x0400 1026 0x0402 1028 0x0404 1036 0x040C 1038 0x040E 1040 1042 1044 1048 0x0410 0x0412 0x0414 0x0418 Modbus Reg Length 3 1 Modbus Reg Type 12-bit serial number, hexadecimal 8-bit integer Comment 2 INT32(6+2) 2 INT32(6+2) 2 INT32(5+0) 2 INT32(3+3) 2 INT32(2+3) 2 INT32(2+3) 2 INT32(2+3) [(VA phase - N) + (VB phase - N) + (VC phase - N)] / 3 2 INT32(2+3) [(VL1-L2) + (VL2-L3) + (VL3-L1)] / 3 2 INT32(2+3) 2 INT32(2+3) 2 INT32(2+3) 2 INT32(2+3) Copyright KWHIQ - Reproduction and communication of this document is strictly prohibited unless specifically authorized Page 14 Contact information Contact - NL Burgemeester Burgerslaan 40 5245 NH Rosmalen The Netherlands Phone: +31 73 544 3071 Contact - BE Metropoolstraat 11a B2900 Schoten Belgium Phone: +32 32 01 95 95 Contact - UAE Office 901 HQ Tower (North) Dubai Science Park PO.Box: 478817 Dubai -United Arab Emirates Phone: +971 4 4422 9701 Find us online www.kwhiq.com info@kwhiq.com