Rebec CS1616 Digital Signal Processor User Manual

Thank you for your purchase and welcome to the world of Rebec! Please keep your original proof of purchase or invoice in a safe place in case of any warranty claims. Do also mail or register your warranty with the official Rebec service centers and/or agents to ensure that you are provided with the relevant technical support if required.

Notice

  1. To prevent short circuit, please keep the device away from water or damp places.
  2. If water or any other liquid enters the device, cut off the power immediately, and inform the nearest Rebec Service Center or Agent to inspect the product.
  3. Users are not recommended to disassemble the device as there are no user serviceable parts inside; please contact the nearest Rebec Service Center if necessary.

Troubleshooting

Ensure all cables and parts are securely connected before turning on the power. Shown below is the basic troubleshooting procedure that you should follow.

When a failure occurs:

  • Before sending the unit for repair, please refer to the table for common troubleshooting solutions.
  • When it is still not repairable after inspection: Please return the unit to factory settings.
  • Still unable to repair: Please consult the nearest service center or authorized agent for further options.

Troubleshooting Method:

No. Malfunction Reason and Solution
1 No Power
  • Check the power connection and make sure it's secure.
  • Check the ACC connection and make sure it's secure.
2 No Sound
  • Double check if the unit is in MUTE mode.
  • Check if you have chosen the correct input channel.
3 Unable to connect through USB
  • Check the USB connection and make sure it's secure.
  • Check if the driver "HID-compliant device" has been properly installed in your PC.

What's in the Box

CS1616 User Manual 1pc
Mechanical flat head screws (PM3x6mm) 8Pc
Mounting brackets 4Pcs
16P high level input signal line (0.2m) 2Pc
24P Speaker cable (0.2m) 1Pc
16P Speaker cable (0.2m) 1Pc

2. Amplifier Index

Note: The following indicators and diagrams, using 4Ω load, all use APX515 audio analyzer, indoor ambient temperature is 25°C, and the voltage across the dedicated line power supply is 14.4V.

Parameter Test Condition Min Typical Max Unit
High input impedance 51 Ω
Low input impedance 15K Ω
High input voltage It is formulated according to the pre-amplifier, and when the maximum pre-stage effective value, the power amplifier outputs the maximum power 9.2 Vrms
Low input voltage It is formulated according to the pre-amplifier, and when the maximum pre-stage effective value, the power amplifier outputs the maximum power 2.5 Vrms
Continuous output power 4Ω load, 1K sine wave, full power continuous load test greater than 20 minutes, THD<1%, A-weighting 60x12
80x4
W
CH1~CH12
CH1~CH10, Output voltage, maximum
When the corresponding amplifier channel outputs THD<1%, the RAC outputs THD<0.05%. 2.5 Vrms
Frequency 0~-3dB 20 20K Hz
THD+N High level output
4Ω load, 60W output
0.8 %
CH1~CH16
2Vrms output, APX515 input impedance 200KΩ
0.05 %
Noise Level High level output
4Ω load, A-weighting
-73 dBv
CH1~CH16
A-weighting, APX515 input impedance 200KΩ
-89 dB
S/N High level output
4Ω load, 50W output, 1K sine wave, A-weighting
95 dB
CH1~CH16
1Vrms output, APX515 input impedance 200KΩ, A-weighting
95 dB
Dynamic Range
AES17
High level output
4Ω load, 1K sine wave, Signal level range-60dB, A-weighting
90 dB
CH1~CH16
1Vrms output, input impedance 200KΩ, A-weighting
90 dB
Crosstalk High level output
4Ω load, 50W output, 1K sine wave, A-weighting
85 dB
CH1 & CH16
Absolute value
85 dB
SMPTE High level output
4Ω load, half power output power output,
Frequency1: frequency sweep 40~1kHZ, Frequency 2: 7kHZ, Amplitude ratio 4: 1.
0.3 %
CH1~CH16
1Vrms output, APX515 input impedance 200KΩ, A-weighting
0.05 %

3. Interface Definition

  1. Color screen in-line interface
  2. USB connection PC computer interface
  3. DSD Lossless Music Player
  4. Bluetooth indicator
  5. Low level input
  6. RCA1~16 output
  7. COAX input
  8. Optical input
  9. 12V power interface
  10. 13~16CH high-level outputs (Bridge 2X200W)
  11. 1~12CH high-level outputs
  12. High-level inputs
  13. Start mode switch
  14. Power LED

Front Panel:

[Image: Front panel of the Rebec CS1616 showing numbered ports: 1. Remote, 2. PC, 3. USB, 4. ANT, 5. AUX, 6. BT, 7. OPT, 8. COAX, 9. 12V Power Interface]

Rear Panel:

[Image: Rear panel of the Rebec CS1616 showing numbered ports: 9. +12 GND, 10. 13~16CH High-level Outputs, 11. 1~12CH High-level Outputs, 12. High-level Inputs, 13. Start Mode Switch, 14. Power LED]

Speaker Wiring

The Speaker Wiring in Normal Mode (4x80W)

[Image: Diagram showing speaker wiring for normal mode, connecting outputs to speakers for 4x80W configuration.]

The Speaker Wiring in Bridge Mode (2x200W)

[Image: Diagram showing speaker wiring for bridge mode, connecting outputs to speakers for 2x200W configuration.]

Software Introduction

PC Software Operation Introduction

Computer Configuration Requirements: Screen resolution higher than 1280 x 768, otherwise the software UI is incomplete, only suitable for Windows operation system laptop, desktop and pads.

1. Menu editing area

Main functions: File, options operation.

a. Click the "File" pop-up window, and select to load the scene on your computer, save it as scene on your computer, load the whole machine scene or save the whole machine scene.

  • Load machine preset scenarios
  • Save as machine preset scenarios
  • Load the scene file on your computer
  • Save it as scene file on your computer
  • Loading machine scene
  • Save machine scene

Note: If you need to share tuning parameters, please connect the machine, and "save machine scene" to the personal computer to share this "machine scene".

b. Click on "Option" to select Chinese and English switching, Noise Gate, RESET, InPutVOL and About(A).

  • 简体中文
  • 繁體中文
  • ✓ English
  • Noise Gate
  • RESET
  • InPutVOL
  • About(A)

2. Function editing area

Main functions: preset, master source, mixer source, channel type, link, mixer and mode settings.

a. Preset: 6 sets of preset data can be recalled or stored.

b. Master source: Click the input audio source drop-down list to select the input audio source: AUX, BT, HI Level, OPT and USB.

[Image: Screenshot of the Master Source dropdown menu showing AUX, BT, HI Level, OPT, USB.]

c. Reset: Click Reset to clear the channel type or restore the default channel type.

d. Link: Click the Link to set the Link synchronization mode: copy from left to right or copy from right to left.

e. Click "Mixer" to enter the mixing interface, the interface is as shown below.

[Image: Screenshot of the Mixer interface showing multiple input channels and faders.]

f. Click "Stereo" to switch between stereo or bridge.

3. Main volume and software connection editing area

Main functions: master volume and computer software connection settings.

a. Main volume adjustment range: off, -59.9~6dB. Click the speaker button to mute the main volume.

b. Click the "Not Connected" button to connect the host with a PC.

[Image: Button showing 'Not connect' and 'Connected' states.]

4. Output channel type editing area

Main function: configure the type of output channel.

[Image: Display showing output channel types like FL-Tweeter, FR-Tweeter, etc.]

5. Channel delay, volume, phase editing area

a. Push the fader left or right to adjust the sound size, or enter a value or roll the mouse wheel in the volume input box to adjust the sound size. Click the speaker button to switch mute.

b. Positive phase adjustment: Click [0°] or [180°] to switch between positive phase and reverse phase.

c. Delay: set the delay value by scrolling the mouse wheel in the delay input box, or enter the value to set the delay value.

d. Delay Unit button: Click the drop-down list to select milliseconds, centimeters, and inches.

6. Channel divider editing area

Main Function Setup: Channel High & Low Pass Filter Setup. Adjustable: Filter Type, Frequency point and Q Value (Gradient or Slope).

[Image: Settings for High-pass and Low-pass filters with options for Frequency, Type, and Octave.]

7. Equalizer editing area

a. Reset EQ: It is used to restore the parameters of the all equalizer to the original pass-through mode (the frequency of the equalizer, the Q value and the gain are restored to the initial value).

b. Restore EQ: Switch between the currently designed equalizer state parameters and the pass-through mode (the gain of all equalization points is restored to 0 dB, the frequency and value are unchanged).

c. Click PEQ Mode to switch GEQ Mode. The Q value and frequency cannot be adjusted in the PEQ Mode interface.

8. Channel EQ editing area

Main function configuration: Equilibrium design of current output channel, 31-band equalization adjustable: frequency, Q value (response bandwidth) and gain (increasing or decreasing the frequency response amplitude near the frequency point).

[Image: Screenshot of the 31-band equalizer interface showing frequency, Q value, and gain adjustments.]

Models: CS1616, CS1616 16 Channel DSP Amplifier, 16 Channel DSP Amplifier, DSP Amplifier, Amplifier

PDF preview unavailable. Download the PDF instead.

CS1616User-manual Corel PDF Engine Version 22.0.0.412 CorelDRAW 2020

Related Documents

Preview Rebec CS810 Digital Signal Processor User Manual
User manual for the Rebec CS810 Digital Signal Processor, covering introduction, troubleshooting, technical specifications, interface definitions, speaker wiring, and software operation.
Preview Rebec RPX-B12SV2 Digital Signal Processing Amplifier User Guide
Explore the features, specifications, and installation guidance for the Rebec RPX-B12SV2, a digital signal processing amplifier for automotive audio systems. Learn about its connectivity options, power output, and Bluetooth pairing.