User Manual for BRUKER models including: AS-2-Rb v5.1, AS-2-Rb Spark Optical Emission Spectrometer, AS-2-Rb, Spark Optical Emission Spectrometer, Emission Spectrometer, Spectrometer

Adapter strand 2: with red dye Rb

Dynamic Biosensors GmbH

Adapter strand 2: with red dye Rb


File Info : application/pdf, 4 Pages, 1.57MB

PDF preview unavailable. Download the PDF instead.

AS-2-Rb
heliX +
User Manual
ADAPTER STRAND 2
with red dye Rb
Dynamic Biosensors GmbH AS-2-Rb v5.1

Key Features
· Adapter strand 2 for functionalization of heliX® Adapter Chip Spot 2. · Compatible with heliX® Adapter Chip. · Includes Adapter strands for 50 regenerations. · Ideal for MIX&RUN sample preparation. · Adapter strand 2 carries a hydrophilic red dye (Rb) with a neutral net charge.
heliX® Adapter Chip Overview
2 spots with 2 different anchor sequences for DNA-encoded addressing.

Product Description

Order Number: AS-2-Rb

Table 1. Contents and Storage Information

Material

Cap

Adapter strand 2 - Rb

White

Concentration Amount

400 nM

5 x 100 µL

For research use only. This product has a limited shelf life, please see expiry date on label. To avoid many freeze thaw cycles please aliquot the nanolever.

Buffer TE40 [1]

Storage -20°C

AS-2-Rb v5.1

www.dynamic-biosensors.com

Page 1 of 3

Preparation | MIX&RUN

In-solution hybridization of adapter and ligand strands:
1. Mix Adapter strand 1 - Rb (400 nM) and conjugated Ligand strand with ligand 1 (500 nM) at 1:1 ratio (v/v).
2. Mix Adapter strand 2 - Rb (400 nM) and conjugated Ligand strand with ligand 2 (500 nM) at 1:1 ratio (v/v).
3. Incubate separately the two solutions of step 1 and 2 at RT at 600 rpm for 30 min to ensure complete hybridization.
4. Mix solution of step 1 and 2 at 1:1 ratio (v/v).
Solution is ready to use for biochip functionalization.
Stability of the solution is related to the stability of the ligand molecules.

Table 2. Additional material for functionalization of spot 1 and reference spot 2.

Material
Adapter strand 1 - Rb
Ligand strand carrying the conjugated ligand 1
Ligand strand carrying the conjugated ligand 2

Concentration 400 nM 500 nM
500 nM

Buffer TE40 [1] PE40 [2]
PE40 [2]

Related Product Name Adapter strand 2 with red dye Rb heliX® Amine Coupling Kit 1
heliX® Amine Coupling Kit 1

Order No AS-1-Rb HK-NHS-1
HK-NHS-1

Example

Required volume for 3 functionalizations: 100 µL with a final concentration of 100 nM.

Vial 1
Adapter strand 1 - Rb (400 nM)
25 µL

Conjugated Ligand strand with ligand 1 (500 nM)
25 µL

Vial 2
Adapter strand 2 - Rb (400 nM)
25 µL

Conjugated Ligand strand + with ligand 2 (500 nM)
25 µL

After incubation time, mix vial 1 and vial 2 to obtain 100 µL of ready-to-use DNA solution.

AS-2-Rb v5.1

www.dynamic-biosensors.com

Page 2 of 3

Contact

Dynamic Biosensors GmbH Perchtinger Str. 8/10 81379 Munich Germany

Bruker Scientific LLC 40 Manning Road, Manning Park Billerica, MA 01821 USA

Order Information order@dynamic-biosensors.com Technical Support support@dynamic-biosensors.com
www.dynamic-biosensors.com
Instruments and chips are engineered and manufactured in Germany. ©2025 Dynamic Biosensors GmbH For Research Use Only. Not for use in clinical diagnostic procedures.

[1] TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 M EDTA, 50 M EGTA [2] If the protein is not stable in PE40 (TE40, HE40), please check buffer compatibility with the switchSENSE® compatibility sheet.

AS-2-Rb v5.1

www.dynamic-biosensors.com

Page 3 of 3



References

HexaPDF version 1.2.0