Pedrollo SAR 550 Accumulation and Lifting Stations
SAR 550 with Drainage Pumps
Specifications for SAR 550 stations equipped with drainage electric pumps.
TYPE | POWER (P2) kW | HP | MAX FLOW (1 pump) liters/min | MAX HEAD meters |
---|---|---|---|---|
TOP 4 | 0.75 | 1 | 320 | 12.5 |
TOP 5 | 0.92 | 1.25 | 360 | 15 |
Dm 10 | 0.75 | 1 | 300 | 15.5 |
Dm 20 | 0.75 | 1 | 250 | 19 |
Dm 30 | 1.1 | 1.5 | 275 | 25 |
? Indicates for clear wastewater.
Uses and Installations
The SAR 550 accumulation and lifting stations are suitable for collecting and lifting clear, rainwater, and residual water from civil and industrial drains, where the sewage network is too far or cannot be reached by gravity. The SAR 550 stations are compact and easy to install on the ground or underground, both indoors and outdoors in residential buildings, offices, or public buildings for discharging wastewater, as well as in gas stations or parking lots for eliminating rainwater.
Components
- Polyethylene tank with a capacity of 550 liters, equipped with two covers not suitable for vehicle traffic, and pedestrian load up to 100 kg max.
- Two single-phase electric pumps (without float switch) pre-installed and connected to a supplied control panel.
- Power cable: standard equipment 10 m.
- Electrical control panel (model E2).
- Three float switches with functions for:
- 1) Alternating activation of one of the two pumps.
- 2) Maximum level with the second pump activated.
- 3) Minimum level for pump shut-off.
Available Configurations (On Request)
- SAR 550 accumulation station with two single-phase electric pumps to choose from according to needs.
- Three-phase version.
Optional Accessories (On Request)
- Alarm kit (Code: KSKIT-ALLARME). The kit consists of: electrical panel, self-powered siren, float switch.
- Kit for 300 mm extension (Code: KSKIT-308MA). The kit consists of an extension to install the "SAR" polyethylene tank at a greater depth. For SAR 550, two kits are needed.
- "SAR" stations with ball check valve and ball valve in the discharge pipe.
SAR 550 with Vortex Pumps
Specifications for SAR 550 stations equipped with vortex electric pumps.
TYPE | POWER (P2) kW | HP | MAX FLOW (1 pump) liters/min | MAX HEAD meters |
---|---|---|---|---|
VXm 10/35 | 0.75 | 1 | 400 | 12 |
VXm 15/35 | 1.1 | 1.5 | 500 | 16 |
VXm 10/50 | 0.75 | 1 | 550 | 9.5 |
VXm 15/50 | 1.1 | 1.5 | 650 | 12 |
BCm 10/50 | 0.75 | 1 | 600 | 11 |
BCm 15/50 | 1.1 | 1.5 | 750 | 14 |
? Indicates for dirty wastewater.
SAR 550 with Shredder Pump (TRITUS)
Specifications for SAR 550 stations equipped with TRITUS shredder electric pumps.
TYPE | POWER (P2) kW | HP | MAX FLOW (1 pump) liters/min | MAX HEAD meters |
---|---|---|---|---|
TIGm 0.75 | 0.75 | 1 | 140 | 17.5 |
TRm 0.9 | 0.9 | 1.25 | 170 | 15 |
TRm 1.1 | 1.1 | 1.5 | 140 | 21.5 |
TRm 1.3 | 1.3 | 1.75 | 220 | 22.5 |
TRm 1.5 | 1.5 | 2 | 270 | 25 |
TRm 2.2 AP | 2.2 | 3 | 275 | 35 |
? Indicates for wastewater.
[Note] On request, SAR stations can be supplied with coupling feet and guide pipes for pump descent.
Dimensions and Weights
Specifications for SAR 550 stations including dimensions and weights.
TYPE | INLET/OUTLET | WEIGHT (kg) |
---|---|---|
SAR 550 - TOP 4 | 1 1/2" | 109.0 |
SAR 550 - TOP 5 | 1 1/2" | 110.9 |
SAR 550 - Dm 10 | 1 1/2" (DN 50) | 116.4 |
SAR 550 - Dm 20 | 1 1/2" | 116.4 |
SAR 550 - Dm 30 | 1 1/2" | 123.2 |
SAR 550 - VXm 10/35 | 1 1/2" | 118.8 |
SAR 550 - VXm 15/35 | 1 1/2" | 124.4 |
SAR 550 - VXm 10/50 | 2" (DN 75) | 119.8 |
SAR 550 - VXm 15/50 | 2" (DN 110) | 125.4 |
SAR 550 - BCm 10/50 | 2" | 120.8 |
SAR 550 - BCm 15/50 | 2" | 126.0 |
SAR 550 - TIGm 0.75 | 1 1/2" | 120.4 |
SAR 550 - TRm 0.9 | 1 1/4" | 136.4 |
SAR 550 - TRm 1.1 | 1 1/4" (DN 50) | 139.7 |
SAR 550 - TRm 1.3 | 1 1/4" | 139.4 |
SAR 550 - TRm 1.5 | 1 1/2" | 178.4 |
SAR 550 - TRm 2.2 AP | 1 1/2" | 195.4 |
Note on connections: (1) Male threaded connection.
Diagram Descriptions:
The SAR 550 stations are available in various configurations. Diagrams illustrate the tank structure and connection points. The standard tank configuration includes inlet, discharge, and ventilation connections. An optional extension kit allows for greater installation depth. TRITUS versions can be equipped with coupling feet and guide pipes for easier pump installation and removal.
Legend for Connections:
- I: Collection pipe inlet.
- U: Discharge pipe connection.
- S: Ventilation pipe inlet.