FSP150-AxxN3 Series 150W Adapter
Technical Datasheet
Features
- Meets IEC 62368-1
- Meets Energy Star EPS2.0/ ErP Lot 7
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
The product is certified by CULUS (I.T.E. POWER SUPPLY E190414), TÜVRheinland (ZERTIFIZIERT Sicherheit ID 1000000000), and CE. It also meets the 10-digit European standard.
Description
This product is a 150-watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, POS systems, and other applications with high wattage demands. It operates at an input voltage range of 90 to 264 VAC. The unit complies with EN55022, EN55024, and FCC class B emission limits and is intended for ITE (Information Technology Equipment) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 2A |
No load power consumption | 115Vac, 230Vac ≤ 0.15W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Power factor | 115Vac, 230Vac / full load ≥ 0.9. Provisions for harmonic reduction per EN 61000-3-2 must be present. |
Efficiency | See rating chart. |
Power turn-on time | At 100Vac / full load, output voltage shall remain regulation ≤ 3Sec |
Hold-up time | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms |
Inrush current | 100Vac, 240Vac / full load, Shall be less than the rating of adapter critical component (including rectifiers, fuse surge and current limiting device) |
Operating altitude | 5000 meters above sea level |
Withstand voltage | Between AC input and secondary applied DC: 4242V, test time 1 minute, cut off current shall be less than 10mA |
MTBF | 100Vac, 240Vac / full load, 300,000 hours at 25°C, standard SR332 |
Output Specifications
Parameter | Details |
---|---|
Output voltage/current | See rating chart |
Total output power | 150W |
Protection: Over voltage | The adapter will enter into shut down (no output) if over voltage occurs at the output terminal due to an internal fault. The output trip voltage shall not exceed 19/29/37/63/66* volts. Recovery to normal state is by AC reset. |
Protection: Short circuit & Over current | When an internal fault occurs, or an external fault is applied to the power supply causing an overload or short circuit on the output, the power supply shall shut down and enter auto-recovery mode. |
Protection: Over temperature | The power supply will enter into shut down if abnormal thermal rise occurs. Recovery to normal state is by AC reset. Set at 60Vac~70Vac. |
Protection: Brown-out | Set at 60Vac~70Vac. |
EMC Performance
Standard | Performance |
---|---|
EN55032 | Class B conducted, Class B radiated |
FCC | Class B conducted, Class B radiated |
VCCI | Class B conducted, Class B radiated |
EN61000-3-2 | Meet class D |
EN61000-3-3 | Meet regulation |
EN61000-4-2 | Air discharge: ± 15 KV, contact discharge: ±8KV, meet criterion A |
EN61000-4-3 | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4 | Impulse: ± 1kV applied to L,N, meet criterion A |
EN61000-4-5 | ± 1kV applied differential mode, ± 2kV applied common mode, meet criterion A |
EN61000-4-6 | 0.15~80 MHz, 3Vrms, 80% AM (1kHz), meet criterion A |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11 | Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C. Voltage Interruptions: >95% reduction for 250 period, meet criterion C. |
Power De-rating
100Vac or 240Vac: 0°C to 40°C, 100% load; 50°C, 85% load; 60°C, 70% load; 70°C, 55% load. (De-rating shall be less than the rating of adapter critical component, follow FSP specification).
Notes
- *Volts express by order of 150-AHxN3 / ABxN3 / AAxN3 / AFxN3 / AWxN3
Performance Curves
Input Voltage Derating Curve
This graph illustrates the adapter's output power capability relative to input voltage. The curve shows that the adapter maintains 100% output power across the entire specified input voltage range from 90 VAC to 264 VAC, indicating no derating is required within this operational range.
Output Power Derating Curve
This graph shows the adapter's output power capability as a percentage of maximum load relative to ambient temperature. The adapter operates at 100% maximum load up to approximately 40°C. Beyond this temperature, derating occurs: approximately 85% load at 50°C, 70% load at 60°C, and 55% load at 70°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency | ||
---|---|---|---|---|---|---|
DOE(Level VI) | Erp(Tier 2) | CoC V5 (Tier 2) | ||||
FSP150-AHAN3 | 12V | 12.5A | C14 | ≥88% | ≥89% | ≥89% |
FSP150-AHBN3 | C6 | ≥88% | ≥89% | ≥89% | ||
FSP150-ABAN3 | 19V | 7.89A | C14 | ≥88% | ≥89% | ≥89% |
FSP150-ABBN3 | C6 | ≥88% | ≥89% | ≥89% | ||
FSP150-AAAN3 | 24V | 6.25A | C14 | ≥88% | ≥89% | ≥89% |
FSP150-AABN3 | C6 | ≥88% | ≥89% | ≥89% | ||
FSP150-AFAN3 | 48V | 3.13A | C14 | ≥88% | ≥89% | ≥89% |
FSP150-AFBN3 | C6 | ≥88% | ≥89% | ≥89% | ||
FSP150-AWAN3 | 54V | 2.78A | C14 | ≥88% | ≥89% | ≥89% |
FSP150-AWBN3 | C6 | ≥88% | ≥89% | ≥89% |
Mechanical Specifications
The adapter has the following external dimensions:
- Length: 151.3 ± 0.5 mm
- Width: 75.6 ± 0.5 mm
- Height: 25.4 ± 0.3 mm
These dimensions apply to models FSP150-AXAN3 and FSP150-AXBN3.
Connector Specifications
The DC output connector is a DIN plug with a shell. The pinout, polarity, and color are as follows:
DIN PLUG | POLARITY | COLOR |
---|---|---|
P1 | VO(+) | RED |
P2 | GND(-) | BLACK |
SHIELD (P3) | GND(-) | BLACK |
P4 |
The diagram shows P3 and P4 connected to the shell, indicating they are related to ground or shielding.