Installation Guide for VICTORY models including: LSF Glass Door Merchandiser Freezer, LSF, Glass Door Merchandiser Freezer, Merchandiser Freezer, Freezer

Manual

LSF27HC-1-IQ | Glass Door Merchandiser Freezer with Electronic Lock | Victory Refrigeration


File Info : application/pdf, 26 Pages, 3.20MB

PDF preview unavailable. Download the PDF instead.

809-201A MANUAL INSTALLATION AND OPERATION VICTORY LSF
INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon LSF Freezer Models

809-201A Rev. A. 04/29/2025 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web:victoryrefrigeration.com

SEE BACK COVER FOR WARRANTY REGISTRATION

User Manual for LSF Freezers
WELCOME
Congratulations on your purchase of Victory food service equipment. Every employee welcomes you to the family of satisfied Victory customers.
From the earliest stages of production design, to focused steps in fabrication and assembly, rigid standards of quality are maintained by our staff of skilled employees. Victory strives to supply superior products through strict quality control guidelines exceeding industry standards, this means that each unit, given the proper maintenance will provide years of trouble free experience to its owner.

Victory
Additionally, Victory food service equipment has one of the best warranties in the food service industry, and backed by a professional staff of service technicians across the country. We thank you for your choice and confidence in Victory Equipment.

Important Information
· PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR USING, IF RECOMMENDED PROCEDURES ARE NOT FOLLOWED, WARRANTY CLAIMS MAY BE DENIED.
· Your warranty registration information is located with this manual. Please complete the card and submit it to Victory within TEN days of installation. Failure to properly register equipment may limit or void the warranty.

· Victory reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.

Contents
Safety ...............................................................................................3 Cleaning and Maintenance ....................................................... 17 Important Information .................................................................5 Condenser Cleaning..................................................................... 18 Product Information .....................................................................6 Methods For Cleaning Stainless Steel.................................... 19 Clearance and Placement ............................................................ 7 Help................................................................................................ 20 Unpacking and Set Up ..................................................................8 For The Service Tech - R290 .................................................... 21 Leveling............................................................................................9 For The Service Tech - Wiring Diagram................................. 22 Shelf Installation.......................................................................... 10 Limited Warranty ....................................................................... 24 Electrical.........................................................................................11 Limited Warranty (continued) ................................................. 25 Using The Unit.............................................................................. 12
Sequence of Operations Freezer .................................... 13

2

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

SAFETY
This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However, safe operation and maintenance are your responsibilities. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

CAUTION

Use: When using this unit, please:

· Move it carefully. If on casters be sure the casters · Prevent children from playing in or on the cabinet.

do NOT run over the power cord.

Persons unable to use this product must be

· Lock the casters when in use.

prevented access.

· Follow all instructions. There are many safety

· Seek help. This machine is heavy! Be sure to move

labels and directions on the unit. Heed them.

with enough help to avoid tipping or dropping the

cabinet.

· Watch your fingers. There may be pinch points near

the door hinges.

CAUTION

Maintenance Do NOT:

Do ALWAYS

· Clean a frozen evaporator with a sharp object
· Clean a dirty condenser with a sharp object.
· Store gasoline, kerosene or any other flammable material near the cabinet.

· Use a Victory recommended technician certified to repair R290 equipment.
· Use ONLY Victory factory service parts. Use of non OEM parts can be dangerous because of the design changes needed to safely use R290.

Important Information to Add
Record the model number, serial number and the date of installation here for future reference. The model and serial numbers are on the unit's serial number dataplate, which is located on the left inside wall.

Model Number Serial Number Date of Installation Purchased From
CAUTION

WARNING

Observe the Caution and Warning notices. They are indicators of important safety information. Keep this manual for future reference.

Rev. 04/25

Victory

3

User Manual for LSF Freezers

Victory

SAFETY

CAUTION

CAUTION: If it is necessary to move the Freezer after removal from the skid, remove all doors and carefully push the unit at a point of no more than 36" from the bottom to avoid damage.

Do NOT push in this area.
Height will vary by model
Push ONLY below the 36 inch / .91 meter height

4

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

IMPORTANT INFORMATION
This unit is intended to be used in a commercial application. That includes bars and restaurants.

If installed in a residence some commercial service companies may not be able to service it on site.

The manufacturer has designed and produced this machine with the finest in materials. The manufacturer assumes no liability for units that have been altered in any way. Alterations or part substitutions will void the warranty.

Limitations
The machine is designed for use indoors in a controlled environment. It must be kept dry, not overheated or subjected to excessive cold. May only be connected to a dedicated electrical circuit. Extension cords are not permitted.

Voltage Room Air Temp

Minimum 103.5 60º F

Maximum 126.5 100º F

Air Flow, All Models regardless of section, door count or door material.

ROOM AIR IN

WARM AIR OUT

Agency Approvals
These marks appear on the dataplate or serial tag, located in the inside of the left wall. The dataplate also contains the model and serial numbers as well as electrical requirements.

Rev. 04/25

Victory

5

User Manual for LSF Freezers

Victory

PRODUCT INFORMATION

Model
LSF23HC-1 LSF27HC-1 LSF49HC-1 LSF72HC-5
LSF23HC-1-IQ LSF27HC-1-IQ LSF49HC-1-IQ

Cabinet Dimensions w x d x h (Inches)

Door Count

Full Load Amps

Power Cord Refrigerant Type / Plug (NEMA) Charge (g) / Charge (oz.)

27 1/4 x 34 x 84 1/8 30 x 34 x 84 1/8

1 Full Glass 6.34 1 Full Glass 10.0

5-15P

R-290 / 95 / 3.35 R-290 / 100 / 3.53

51 15/16 x 34 1/16 x 83 15/16 2 Full Glass 13.9 75 1/16 x 34 1/16 x 83 15/16 3 Full Glass 14.0

5-20P

R-290 / 95 / 3.35**X2 R-290 / 150 / 5.3**X2

UNITS WITH ELECTRONIC LOCKS

28 3/8 x 34 1/16 x 83 15/16 1 Full Glass 6.34 31 1/8 x 34 1/16 x 83 15/16 1 Full Glass 10.0

5-15P

R-290 / 95 / 3.35 R-290 / 100 / 3.53

51 15/16 x 34 1/16 x 83 15/16 2 Full Glass 13.9

5-20P

R-290 / 95 / 3.35**X2

Height includes casters.

· All models will maintain product temperature of 0oF. and below, with the factory setting of 0.0F. · **X2 means the unit has 2 systems. · All models are 115 volts, 60 Hz AC and are equipped with either a NEMA 5-15P, or 5-20P plug. · ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS, REFRIGERANT AND REFRIGERANT CHARGE FOR THE
MOST UP TO DATE AND ACCURATE VALUES. · There are no access valves on the refrigeration system.

6

Victory

Rev. 04/25

User Manual for LSF Freezer
CLEARANCE AND PLACEMENT
3" LEFT/RIGHT SIDE
MINIMUM CLEARANCE

12" TOP MINIMUM CLEARANCE

Victory
3" REAR MINIMUM CLEARANCE

6" BOTTOM MINIMUM CLEARANCE

Placement Consider the following when selecting a location for your Freezer: Clearance: · 12.0 in. at the top · 3.0 in. at the rear · 3.0 in. at the left side · 3.0 in. at the right side · 6.0 in at the bottom Floor Load: the floor on which the Freezer is located must be even and level, free from vibrations, and strong enough to support the combined weights of the unit and maximum product load. Ventilation: Grille area at front must be free and clear of any object or wall. Power Outlet: Dedicated power outlet is located within the length of the unit's power cord.

Rev. 04/25

Victory

7

User Manual for LSF Freezers

Victory

UNPACKING AND SET UP
Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim. Do NOT contact the manufacturer.

Uncrating
Tools Needed: ¾" box wrench, adjustable wrench, level, flat head screw driver, and box cutter.

3. Move unit as close to final position as possible before removing the skid.

1. Remove the cardboard top capping, all clear tape, and all staples including those at the bottom of the cardboard carton and skid.
2. Start from the top of the carton. Using the box cutter, carefully make one continuous cut to the bottom of the skid. Remove cardboard carton and discard.

Note: The skid must be removed before the casters or legs can be attached.
Do NOT tip unit on its front or sides. If tipped onto the back, unit must not be started for 3 hours.
Note: additional clear plastic protective wrap is applied directly to any product with a glass door.

Skid Removal and Caster Attachment Tip the unit forward and remove the skid.
WARNING
Risk of personal injury. Unit must be securely supported while attaching casters or legs.
1. Remove the shipping bolts using the ¾" box wrench while cabinet is held in one direction. Repeat the process while the cabinet is held in the opposite direction.

2. Tilt the cabinet in one direction approximately 8" and block it securely with pieces of 2x4 lumber or other suitable material.
Note for the following: None of the threads on the leg or caster stem should be visible once screwed in.
3. Thread the stem casters or legs into the ½ -13 holes in the bottom of the cabinet. Tighten by hand as much as possible.
4. Once the caster or leg cannot be turned any further, use a 3/4 inch wrench to tighten the nut in between the mounting plate and the wheel of the caster until snug.
5. Repeat this procedure with unit secured in the opposite direction so as to access the remaining legs/casters/ levelers

Leveling Cabinets must be leveled when installed. Level should be measured on the headrail.
Failure to level your cabinet may result in door not sealing, closing correctly, or condensed water not draining properly.
For cabinets with legs, rotate the foot of the leg with an adjustable wrench to achieve desired height for leveling.

Do NOT loosen casters to level the
CAUTION cabinet. Casters MUST be tightly
secured to cabinet for full strength.
Install or attach any accessories that will be used Remove any plastic covering the stainless steel.

For cabinets with casters, level by placing large washers in between the ½' stud and the holes in the bottom of the case.

8

Victory

Rev. 04/25

U0s1e2r3ÿM5a6n7u8a6l9ÿf
or3ÿL5S5F Fÿre3e2z2e
r231ÿ
efgfehij
.7/30/15283A435;ÿ7ÿ@825ÿ44=ÿ033ÿ=ÿ933:/3;9A3/;19ÿ><=32ÿ1254/993;>ÿ?3:39ÿ5=@89;ÿ03ÿ BDG9/A@@159G8123AA3E9ÿÿC4D@>@ÿA93A3:D3499ÿCCF@ÿ@8AAÿÿDD@/20;1233245ÿ73;/ÿC<ÿA/34358Aÿ9;4ÿA1/21ÿ2;1@2@EAÿÿ22@@44ÿÿ;5A3//1921212EEFÿÿ B/;@AI8ÿD5/40/012933ÿ4<5ÿA<3124D==ÿ9ÿ34E@5ÿ/FÿDA=@143/:433ÿÿ4;=335ÿ1HA@3@;4ÿÿ=@3Hÿ14E==34ÿÿ9H3@EAÿÿ<931:43=9ÿ1/22Eÿ> B9@/@2AAÿE4ÿD=3/ÿ3<0ÿ01/2@534=443@5A7ÿ<5ÿÿ11@24H=ÿÿ04ÿD=3/345<ÿD433/3A5523F>ÿÿÿ493=:33ÿJ91K2ÿ5E4ÿ8D;/2ÿ/ÿ20;3ÿÿ/4=D3=ÿ1=3@:933;5ÿÿ09@CDÿG/94/3D;1ÿ2Eÿ
OL@@@43AÿM0ÿN3Hÿ92@@<ÿDÿ4/=5343ÿ3AP58Fÿ913GE753ÿ@2A4ÿÿ973:835943ÿA053ÿ/ÿ9A33:ÿ34@9>ÿ03ÿ1254/993;Fÿ4=3ÿ
'()*+,- 5QX3YRD^ÿ-8_WA,3V*;Z`ÿÿTÿ4.R@/RÿD5U/4V30WA1ÿ52XÿY3aU4ÿZbHV@c[AdUÿHÿÿZ08R39ÿ9Tÿÿ4V514\EAV=3T42ÿZ9EC]4ÿV=ÿ>
N254/99ÿ@Aÿ/44/D=ÿ/2Cÿ/DD355@A135ÿ4=/4ÿ<199ÿ03ÿ853;

223V6ic2tory3

Rev. ÿ04/25

Vic!to"ry#$%

9&

User Manual for LSF Freezers
SHELF INSTALLATION
1. Determine the proper location for the shelf clips.
2. Insert the top tab of the shelf clip into the desired hole of the pilaster. The retaining tab MUST be facing up as shown.
3. Rotate the clip downwards and insert the bottom tab into the matching hole in the pilaster. The clip may need to be squeezed slightly during installation.
4. Install all remaining clips.
5. Install shelves onto clips with the product retention bar facing up. Be careful not to dislodge clips during installation.

Victory
6. Place shelves so that the retaining tab on the clip captures the shelf as shown.
7. Confirm that the shelf is resting on ALL 4 clips and that the clips are securely attached to the pilasters.
8. Improper shelf clip installation could cause the shelf and / or the product on it to fall, resulting in damage to the unit and possible bodily injury.
9. Do NOT overload the shelves. The unit is designed to use all shelves that are supplied in an equally spaced manner. Contact Victory customer service if fewer shelves or a different configuration to ensure shelf overloading will not occur.

CORRECT

INCORRECT

PROPERLY INSTALLED CLIPS

10

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

ELECTRICAL
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.

Power Cord
The back panel must be removed to allow the cord to be deployed.

1. Remove the Philips heads screws on the top and sides of the rear panel.

Follow All National and Local Codes
This unit must be grounded. Do not use extension cords and do not disable or by-pass ground prong on electrical plug.

Initial Start Up Plug the power cord into the proper power supply.

The cabinet will soon begin to blow warm air out of the top area, and cool air will flow from the inside blower.

2. Lift upwards slightly and remove the panel.

The cabinet temperature has been set at the factory and should not need adjustment, however if it was changed, the standard setting is 0º F.

Power Cord
Carefully cut ONLY cable tie to release. Do NOT disturb or cut any other item.

Cautions
Care must be taken whenever moving or servicing the unit. The refrigerant is contained in a sealed system, but if released it may be flammable.
After the cabinet has been installed, leveled, and cleaned as described above, refer to the following checklist:

Check for proper electrical hook-up.

3. To reinstall, insert the bottom of the panel first then push firmly against the unit
4. Line up the screw holes and reinstall the Philips head New: screws
This 115 volt model is equipped with a cord and either a 5-15P or 5-20P plug.

Cabinet MUST NOT SHARE A RECEPTACLE with another piece of equipment
Check that all clearances are in line with the aforementioned guidelines.
Check that cabinet is level.

If the power cord becomes damaged, it must be replaced with the identical cord.

Rev. 04/25

Victory

11

User Manual for LSF Freezers
USING THE UNIT
Operation is simple, just keep it connected to the correct power supply and the freezer will maintain the internal temperature it has been set to. Keep the doors closed as much as possible to avoid unnecessary run time.
The controller is located in the lower front grille of the cabinet. The controller displays the current internal temperature for its section.
Adjusting the set temperature lower will NOT cause the system to lower the temperature faster. When on, the refrigeration system is always operating at maximum.
For best results, make certain the unit remains powered and has achieved the desired set point before loading it with product. Pull down time will vary depending upon the type of unit and ambient conditions

Victory
The freezer temperature was set at the factory at 0º F, but you can adjust it to your own selected temperature.
The freezer will automatically defrost as needed, there is no set time for defrost. Push and immediately release the "melting" or defrost button for a manual defrost.
Note: Holding the defrost button in too long will shut the controller off.
The internal fan will be on whenever the appliance is connected to power.
The compressor and condenser fan motor will only be on when the controller senses an increase in internal cabinet temperature passed the set point.

Defrost Select

0 oF

Increase Decrease

In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has occurred, a message will be shown.

Message Displayed
dEF Hi dOr
LEA
E01, E02, E03, E04

Why Unit is defrosting Cabinet temperature too warm Door is open
Compressor run time too long
Sensor unplugged or has failed

What to do Nothing. Normal operation.
Confirm doors or drawers are closed.
Close door, if message does not change, call for service. Check doors closed. If yes, call for service. Call for service.

12

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

SEQUENCE OF OPERATIONS FREEZER
The freezer operates based on the air temperature measured by the probe located at the return air.

COMPONENT COMPRESSOR
CONDENSER FAN
EVAPORATOR FAN FACE HEATER DOOR HEATER

ON
OPERATION
Compressor turns on when the air temperature at the probe is above the sum of the set point +2
The Condenser Fan turns on when the Compressor is running
The Evaporator Fan runs continuously in freezers. When the unit is plugged in, the Evaporator Fan will run.
The face heater is on when the compressor is on
The door heater is on when the compressor is on

OFF CONTROLLER ACTION OPERATION

The Compressor

Compressor turns

Contact is energized off when the air

temperature at probe is

equal to or less than the (ERC 112 ­ Terminal #1) set point -2

CONTROLLER ACTION The Compressor Contact is deenergized
(ERC 112 ­ Terminal #1)

The Condenser Fan is wired directly to the Compressor, not through the controller

The Condenser Fan turns off when the Compressor is not running

The Condenser Fan is wired directly to the Compressor, not through the controller

The Evaporator Fan is connected directly to incoming power, not through the controller.

The Evaporator Fan runs The Evaporator Fan is continuously. When the connected directly to unit is plugged in, The incoming power, not Evaporator Fan will run. through the controller.

Same as compressor Same as compressor

The face heater is off when the compressor is off
The door heater is off when the compressor is off

Same as compressor Same as compressor

Compressor Condenser Fan Evaporator Fan Face Heater Door Heater

Condition
Cabinet Temp > Set point + 2 Cabinet Temperature <= Set point - 2 Defrost

ON ON ON OFF OFF ON OFF OFF ON

ON ON OFF OFF OFF OFF

Rev. 04/25

Victory

13

User Manual for LSF Freezers
CONTROL PANEL DISPLAY
Electronic Controller DEFROST (ESC)
SELECT (OK)

Victory
UP DOWN

Control Panel Display

Defrost LED

On fixed: Defrost active

Off:

Defrost is off

Fan LED
On fixed: Off:

Fan active Fan Off

Alarm LED

On fixed: ALARM Present

Flashing: ALARM Silenced

Off:

No Alarm

Compressor LED

On fixed: Compressor active

Flashing: Delay, protection or activation blocked

Off:

No Alarm

NOTE: When switched on, the instrument panel performs a lamp test for a few seconds. Keyboard Functions

UP

DOWN

Quick press and release

Quick press and release

· Increases Set Point

· Decreases Set Point

Long press and release

Long press and release

· Increases display brightness · Decreases display brightness

DEFROST (ESC)
Quick press and release · Activates manual defrost Long press and release · Controller enter stand-by mode

SET (ENTER)
Quick press and release · Toggles lights on/off Long press and release · Toggles display °F/°C

Note: When the controller is in a Standby Mode, a

blue dot will be displayed as shown here. To switch out of Standby Mode, push and hold the Defrost button until the display reads ON.

.

14

Victory

Rev. 04/25

User Manual for LSF Freezer
Control Panel Connections
Changing the Set point

Victory

Rev. 04/25

Victory

15

U0s1e2r3Mÿ5a6n7u8a6l9fÿ
or3LÿS
FFÿreezers

22V36ict2ory3

()*+,ÿ./ÿ01023ÿ4561789:;ÿ<9348ÿ024ÿ9;ÿ=2:>2488ÿ?@A@ÿ/:1C42ÿ:/ÿ<D4ÿ=02034<42ÿ<0E14FGÿ<D4ÿ01023ÿ98ÿ;:<ÿ89>;014CH

16ÿ

Victo!r"y#$%

&' Rev. 04/25

User Manual for LSF Freezer

CLEANING AND MAINTENANCE

Cleaning Schedule: Cabinet Daily wipe down
Weekly interior

Condenser coil
Monthly inspection, cleaning as required

Victory

Gaskets
Daily inspection, check that hinges are tight to the cabinet.

Routine maintenance Annually

Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.

1. Wash with a clean sponge and a mild detergent that does not contain chlorine.
2. Rinse with clean water.

4. Polish with a soft cloth, wiping with the grain. 5. Wipe weekly with stainless steel cleaner.

3. Dry with a soft cloth.

Weekly Interior Cleaning 1. Remove all food, food related items and shelves. Store
the food at a safe temperature.
2. Disconnect power to the unit (unplug it or switch the breaker off).
3. Remove all loose food particles from the inside walls, floor, door liner and ceiling.
4. Scrub all interior surfaces and door gaskets with a warm (100oF to 110oF) detergent solution and a soft scrub brush.

5. Rinse with clean water and allow to air dry. 6. Return the shelves to the unit and secure them. 7. Restore power. 8. Return food to the unit when it has reached a safe
temperature.

Rev. 04/25

Victory

17

User Manual for LSF Freezers

CONDENSER CLEANING
Keeping the condenser coil clean is critical to efficient operation.

1. Unplug unit from power supply.

CAUTION

Rotating fan blade can cause personal injury.

Unplug unit from power supply before beginning to clean condenser

2. Pull firmly on the top of the bottom panel to release the locking clips.
Sharp edges can cause
CAUTION personal injury.
Gloves are recommended.

Victory
4. Lower panel completely flat.
5. Examine condenser surface, if dusty, brush and vacuum the dust and lint from the surface of the coil. Brush up and down to avoid damaging the fins. Use care to not disturb the wires connected to the controller.
Note: If the coil is greasy, the coil will need to be cleaned with coil cleaner and that should be left to an experienced technician.
6. To reinstall the front panel line lift the panel and reconnect the communication wire to the display.
7. Line up the locking clips with the pins on the back of the front panel and push firmly.
8. Reconnect power.
Note: Air filters are not recommended as they restrict the flow of cooling air.

Pull Top Out to Release Panel is Hinged at Bottom and Held by Snaps at Sides

3. While holding the panel at an angle remove the communication wire from the back of the digital display.
18

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

METHODS FOR CLEANING STAINLESS STEEL

Cleaning Needed

Cleaning Agent

Smears and fingerprints

Areal 20, Lac-O-Nu, Lumin Wash O'Cedar Cream Polish, Stainless Shine.

Stubborn Spots and Stains, Baked-On Splatter, and Other Light Discolorations
Heat tint or discoloration

Allchem Concentrated Cleaner.
Samae, Twinkle or Cameo Copper Cleaner
Grade FFF Italian pumice, whiting, or talc.
Liquid NuSteel Paste NuSteel or DuBois Temp. Copper's Stainless Steel Cleaner Revere Stainless Cleaner Household cleansers, such as Old Dutch, Lighthouse, Sunbrite, Wyandotte, Bab-O, Gold Dust, Sapolio, Bon Ami, Ajax, or Comet Grade F Italian Pumice, Steel Bright, Lumin Cleaner, Zud, Restore, Sta-Clean, or Highlite. Penny-Brite or Copper-Brite.
Penny-Brite or Copper-Brite. Past NuSteel, DuBois Temp, or Tarnite. Revere Stainless Steel Cleaner. Allen Polish, Steel Bright, Tenacious Deposits, Rusty Discolorations, Industrial Atmospheric Stains Wyandotte, Bab-O or Zud.

Method of Application
Rub with cloth as directed on the package.
Apply with damp sponge or cloth. Rub with damp cloth.
Rub with damp cloth.

Affect on Finish
Satisfactory for use on all finishes. Provides barrier film to minimize prints.

Rub with dry cloth.
Use small amount of cleaner. Rub with dry cloth using a small amount of cleaner. Apply with damp sponge or cloth. Rub with a damp cloth. May contain chlorine bleaches. Rinse thoroughly after use. Rub with a damp cloth. Rub with a dry cloth using a small amount of cleaner.

Use in direction of polish lines on No. 4 (polished) finish. May scratch No. 2 (mill) and Nos. 7 and 8 (polished) finishes.

Rub with a dry cloth. Rub with a dry cloth or stainless steel wool. Apply with damp sponge or cloth. Rub with a damp cloth.

Burnt-On Foods and Grease Fatty Acids, Milkstone (where swabbing or rubbing is not practical)

Easy-Off, De-Grease-It, 4 to 6% hot solution of such agents as trisodium phosphate or sodium tripolyphosphate or 5 to 15% caustic soda solution

Apply generous coating. Allow to stand for 10-15 minutes. Rinse. Repeated application may be necessary.

Excellent removal, satisfactory for use on all finishes.

Tenacious Deposits, Rusty Discolorations, Industrial Atmospheric Stains
Hard Water Spots and Scale

Oakite No. 33, Dilac Texo 12, Texo NY, Flash-Klenz, Caddy Cleaner, Turco Scale 4368 or Permag 57.
Vinegar. 5% oxalic acid, 5% sulfamic acid, 5 to 10% phosphoric acid, or Dilac, Oakite No. 33, Texo 12, Texo N.Y.

Swab and soak with clean cloth. Let stand 15 minutes or more according to directions on package, then rinse and dry.
Swab or wipe with cloth. Rinse with water and dry. Swab or soak with cloth. Let stand 10-15 minutes. Always follow with neutralizer rinse, and dry.

Satisfactory for use on all finishes
Satisfactory for all finishes. Satisfactory for all finishes. Effective on tenacious deposits or where scale has built up.

Rev. 04/25

Victory

19

User Manual for LSF Freezers

HELP

Trouble Diagnosis for the User Malfunction
No cooling - unit is silent

Possible Cause
Unit not plugged in. Fuse or circuit breaker tripped. Power cord plug loose in outlet.

Unit cools but seems to be on all the time Space temperature too high

Dirty condenser
Dirty condenser Evaporator iced over Unit in high temperature environment

Victory
Likely Solution Connect to proper voltage circuit Replace fuse or reset breaker. Check outlet for loose connection, replace as needed Clean condenser
Clean condenser Defrost evaporator Reduce temperature of room

Space temperature too low

Temperature control

Adjust or replace control

Trouble Diagnosis for the Technician

No cooling - compressor does not hum

Temp control stuck in open position

Replace temp control.

No cooling - compressor hums but does not Low voltage to unit.

start

Compressor starting system failure

Check voltage, correct as needed. Check start relay and start capacitor. See next step.

No cooling - compressor starts but shuts off

Compressor start relay failure Compressor start capacitor failure

Replace relay. Replace capacitor.

No cooling - compressor cycles on and off Overheating weak overload

Clean condenser, check fan motor and blade. Check refrigerant charge. Replace overload.

Unit cools, but is slow to pull cabinet temperature down

Evaporator fan not turning

Check fan(s), on multiple fan units one fan may be turning slowly and will need to be replaced.

Unit cools but turns on and off frequently

No product in cabinet. Temperature control defective Refrigeration issue

Fill cabinet Replace control Have system checked

Makes excessive noise

Tubing rattle Loose parts Bent or broken fan blade Noisy fan motor

Check tubing for routing Check for loose components Replace fan blade Replace fan motor

20

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

FOR THE SERVICE TECH - R290
Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems.

Here are some critical service items. This list does not qualify anyone to service the unit. It is a reminder and checklist for the service tech. Keep these in mind for R290 service:
· Wire nuts are NOT to be used when changing an electrical part.
· The switches in this product are sealed, only exact replacements may be used.
· The process tubes are to be used for service access.
· Cut out (with tubing cutter) refrigeration components that are to be replaced. Do NOT un-braze.
· Because R290 can be vented into the air during service, the venting MUST be in an area free from flame or spark. It must be near an opened window or door.

Other Information:
Evacuation: It is critical that a refrigeration system be leak free and internally dry. A thorough evacuation with a good vacuum pump with a micron gauge attached is the only way to ensure that the system is dry and ready for a charge of refrigerant.
Charging: The system is critically charged and the proper type and amount MUST be weighed in.
Overcharge symptoms: Unit will cool properly but the suction line temperature will be unusually cold. Compressor run time will be longer than normal.
Undercharge symptoms: Long run time, poor cooling and a hot compressor dome are the main symptoms of an undercharge.

· A sign noting service of a system containing propane must be attached to the unit during refrigeration service.

· A combustible gas leak detector must be used to inform anyone in the area when propane is present in the air.

Rev. 04/25

Victory

21

U0s1e2r3ÿM5a6n7u8a69lÿ
fo3rÿ5LS5FFÿr3e2e2z
e2r3s1ÿ

22362Vic3tory

FO)*R+Tÿ-H.E/Sÿ0E/R+V1I2C3E/ÿT-E/C3.Hÿ4-ÿ5W2I+R2I6N7Gÿ8D29IA7G+R9A:Mÿ){*F+Oÿ*R6O/Nÿ9E6A8Nÿ-D5T*Wÿ0O;0S-Y/S:TÿE:M*8M/O<D0ELS

I=>HC

[JMHBF] KDCCÿJLMHBLFFCBÿPCHO>F

UFOJV

[ HGB ] KDCCÿH>GCBÿPCHO>FÿRMLHÿOFFÿGLPCFDT
v

[

Y

KDCCÿJLMHBLFFCBÿPCHO>F

JLMPCMDCBÿNOM

DHOBHÿBCFOS

LF

B J JLGA

\ BQJQ

DQJQ

Y`

D[

Y

[

UFOJV I=>HC

DRMCLCHÿHÿO>GFFCÿBGÿLPCPHCOF>DFT

JLMPCMDCBÿNOM

DHOBHÿBCFOS

Y

B\

Y`

LF

J JLGA

BQJQ DQJQ

x

D

[

Y

UFOJV

[

Y

KDCCÿJLMHBLFFCBÿPCHO>F

RLHB=CCFBOSÿGÿMLLPHCÿFEDDÿCJPLÿMLMMCÿOJFHFCÿGPLÿHPLCÿFF>DMCT

KDCCÿJLMNNO>?JCEÿB=OCHO>HLCMBÿJ=OBH KDCC?ÿJFRMOLLDMHDNÿÿO>P?FLEFLÿBGBOLÿ=HPC>CLOFMHDÿCTJB=OBH

[

X

KDCCÿJLMHBLFFCBÿPCHO>F

=COHCBÿDONCHSÿDI>HJ=

PCNBLDHÿ=COHCB



PQ>Q

[

Z

KDCCÿJLMHBLFFCBÿPCHO>F

CWOAÿNOM

UFOJV

PQ>Q [KDCCÿJLMHBLFFCBÿP\CHO>F
RDLF>PÿPLLBDÿLMFST

_AD^
FCP KDCCÿJLMN>?EBOH>LMÿJ=OBH

UOFFODH
BCP SCFFLI

ÿRMLOHDFÿ>>F?MÿGMDHLÿFOP>?FCF=FCHDPTÿLM

j





PBO>MÿHEUCÿ=COHCB|

y

I=>HC

aaaaaaaaaaaaaaaaaaaaaaaJLÿÿGcABdCDeDLÿBfÿPCgHOÿ>hFÿNcLBiÿDÿLaGaCÿaGaLPaCaFDaaaaaaaaaaaaaaaaa

j klkmkjnÿpqnqjrqÿstpÿuptvwxmktl yyzy{z|}|| ~ j |}||q}||

JLMPCMDCBÿNOM

DQJQ

v

hci


hcifdÿhcfhe
LF

B BQJQ J JLGA
D

[

ecY
{Z

  cdÿdf


=>?=ÿABCDDEBCÿF>G>HÿDI>HJ=

DHOBHÿBCFOS

POMNLDDÿJLMHBLFFCBÿPCHO>F Y [ ] \ Z X DY D[ D] D\ P>

>MAEH FLOP

][ Y M F LEHAEH

L]`MÿD^PCCJFLOMSPÿH>GCBÿBCFOS

x

I=>HC

I=>HC

YBDLÿÿDÿÿÿÿJDJF^^ÿÿÿBÿÿÿJ^^^JÿÿÿÿLLDB^LÿHMDWEMOLCMMHBBCFÿBJH>FJPLOÿLHJÿ
mkpvÿjlnqÿupt~
xtqlmr


P>?>HOFÿ>MAEH
CWOAÿDCMDLB O>BÿDCMDLB
PCNBLDH NOM F>?=H MCEHBOF F>MC JLGABCDDLB

I=>HC

ÿ
22

I=>HC

D>?MOFÿBCJ>CWCP D>?MOFÿDCMH

KDCPC>ÿ?JPL>HLMOLNFB>ÿ?>MÿDEAIBE>OHHHÿJJ>L=>BCMJDÿJE=>HOBH

JLMN>?EBOH>LMÿJ=OBH GLPCF DPIL>HLJB= =NCOOJHCCB =PCLOLHCBB F>?=HD D>M?PFLCLÿDBLF>P Y Y ` Y D>M?PFLCLÿ?BFODD Y Y Y Y PLEPUFLCLÿDBLF>P [ [ ` [ PLEUPFLCLÿ?BFODD [ [ [ [

FC?CMP

YBDLÿÿDÿÿÿÿJDJF^^ÿÿÿBÿÿÿJ^^^JÿÿÿÿLLDB^LÿHMDWEMOLCMMHBBCFÿBJH>FJPLOÿLHJÿFADO>OFLOHPCAMJOBOÿH>AHJÿCHLL>CÿHBB>BLMCGHBF>OMSOF

 ¡¢£¡¤ mkpvÿjlnqÿupt~qxmktl wlnqrrÿtmqpkrqÿruqxkskqv

ljq

!"#$%&! qnqxmpmkxjÿnÿlvmkjÿsp¥pjÿjÿ vkqljrlmkttnlwqnrpjÿjjplpÿqxÿÿkqlÿrÿÿ|klÿxqr

vpjl xqxqv

vjmq
mkmnq

kl§pr¨tm©t¨tª«l¬r¨jkn«nnªqq®¦ÿ¯u°¦jÿlx j

Victory

'(
Rev. 04/25

User0M12a3ÿn5u6a7l8fo69rÿ
LS3ÿF5F5reeÿz3e2r2
231ÿ
FOR(T)H*Eÿ,S-E.Rÿ/V.*IC0E12T.Eÿ,C.H2--Wÿ3ÿ4IR1I*N1G56DÿI7A18G6R*A8M9Fÿ(O)xR*Vÿ0S/C2ÿM9O)D7.E:L/S

QMG?R

CAS=FH=?F@ÿULSTBFJ=O<<@FÿJ=HGCM T=

X?AHFMW ;<==ÿ?@AHF@MM=FÿJ=HGCM

s

A

X

Y

;<==ÿ?@AHF@MM=FÿJ=HGCM

M
MLIACCUD@CIHHÿÿÿGT<MFPM=CÿHU<?<@IEJF==M<O
M<P

F <

?

F ?@UT ?

<

PICH=

2236Vi2ctor3y


QMG?R PICH=

u
|
g
g e`f

QMG?R

QMG?R

?@AJ=A<=FÿBGA CAS=FH=FÿLSBJO
T=

A

M

IMLACCUD@CIHHÿÿÿGT<MFPM=CÿHU<?<@IEJF==M<O

F <

M<P

F ? ?@UT ?
<

X

Y

;<==ÿ?@AHF@MM=FÿJ=HGCM

L@HFI==MFGNÿUÿA@@JH=ÿME<<ÿ=?J@ÿA@AA=ÿG?MHM=ÿUJ@ÿHJ@=ÿMMC<A=O

X

Z

;<==ÿ?@AHF@MM=FÿJ=HGCM

JKCK

X

[

;<==ÿ?@AHF@MM=FÿJ=HGCM

JKCK X;<==ÿ?@AHF@MM=FÿJV=HGCM
L<@MCJÿJ@@F<ÿ@AMNO

?@AJ=A<=FÿBGA
;<==ÿ?@ABBGCD?=EÿFIG=HGCH@=AFÿ?IGFH ;<==Dÿ?MLAG@@<AH<BÿÿGCJDM@EM@ÿFUFG@ÿIHJ=C=@GMAH<ÿ=O?FIGFH

I=GH=Fÿ<GB=HNÿ<PCH?I JFGCAÿHEQ=ÿI=GH=F

J=BF@<HÿI=GH=F
=SGTÿBGA ]T<\ M=J
;<==ÿ?@ABCDEFGHC@Aÿ?IGFH
QGMMG<H
F=J N=MM@P
ÿLA@GH<MÿCCMDAÿUA<H@ÿMGJCDM=MIM=H<JOÿ@A

^^^^^^^^^^^^^^^^^^^^^^^ÿÿ`abÿcdÿe`fÿ^^^^^^^^^^^^^^^^^^^^^^^
hihjhgkÿmnkngonÿpqmÿrmqstJGuAB@<j<hÿ?q@AHiF@MM=FÿJ=HGCM vvwvxwyzyy {| g} yzyyn~zyy

e`fcaÿe`ceb

b`

Y X W V [ Z <Y <X <W <V JC

  `aÿac
u

PICH=

PICH=

YF<@ÿÿ<ÿÿÿÿ?<?M\\ÿÿÿFÿÿÿ?\\\?ÿÿÿÿ@@<F\@ÿHA<SEAG@=AAHFF=MÿF?HCM?J@Gÿ@H?ÿMT<GCGM
jhmsÿgiknÿrmq{n
uqnijo

JCDCHGMÿCATEH
=SGTÿ<=A<@F GCFÿ<=A<@F
J=BF@<H BGA MCDIH A=EHFGM MCA= ?@UTF=<<@F

PICH=

''
Rev. 04/25

PICH=

<CDAGMÿF=?C=S=J <CDAGMÿ<=AH

;<=J=CÿD?J@CH@AG@BMFCÿDCAÿ<ETPFECGHHHÿ??C@ICF=A?<ÿ?EICHGFH

?@ABCDEFGHC@Aÿ?IGFH U@J=M <JP@CH@?FI IB=GG?H==F IJ=@G@H=FF MCDIH<

<CADJM@=@ÿ<F@MCJ Y Y  Y

<CADJM@=@ÿDFMG<< Y Y Y Y

J@EJQM@=@ÿ<F@MCJ X X  X J@EQJM@=@ÿDFMG<< X X X X

|

M=D=AJ YF<@ÿÿ<ÿÿÿÿ?<?M\\ÿÿÿFÿÿÿ?\\\?ÿÿÿÿ@@<F\@ÿHA<SEAG@=AAHFF=MÿF?HCM?J@Gÿ@H?ÿMT<GCGM@GHJ=TA?GFGÿHCTH?ÿ=H@@C=ÿHFFCF@A=UHFMCGANGM

!"#$%&! jhmsÿgiknÿrmq{nujhqi tiknooÿqjnmhonÿornuhphns

ign sgjn

shnigoijhqqkitnkomgÿggmimÿnuÿÿhniÿoÿÿyhiÿuno

smgi ununs

 ¡¢
jhjnknknuj|mjhugÿh|ik¥mÿo¦isqj§q¦jqh¨gÿ©ipª~mo¦gh~k©£mkk«¨nng¬¤ÿr®¤gÿiÿu~ÿ g

Victory

ÿ
23

User Manual for LSF Freezers

Victory

LIMITED WARRANTY

Warranty (Continental USA & Canada Only)

SEVEN (7) YEAR PARTS, LABOR, AND COMPRESSOR LIMITED WARRANTY

Victory® Refrigeration (Victory) warrants to the original purchaser of Victory branded equipment, that such equipment is free from defects in material and workmanship, under normal use, proper maintenance and service as indicated by Victory's installation and operation instructions, for a period of SEVEN (7) years from the date of installation, or eighty-seven (87) months from the date of shipment from the manufacturer, whichever is earlier. In addition, Victory® Refrigeration (Victory) warrants the hermetically/semi-hermetically sealed compressor (part only) for SEVEN (7) years; not to exceed eightyseven (87) months from the date of shipment from Victory, provided upon receipt of the compressor, manufacturer examination shows the sealed compressor to be defective. This warranty does not cover freight for the replacement compressor or freight for return of the failed compressor. Also, this compressor-part only warranty does NOT apply to any electrical controls, condenser, evaporator, fan motors, overload switch, starting relay, capacitors, temperature control, filter/drier, accumulator, refrigeration tubing, wiring harness, labor charges, or supplies which are covered by the standard warranty above.

*Units shipped after 07/1/2024. Previous warranty applies to units shipped prior.

Exceptions:

·

Warranty does not apply for units installed

in a Residential application. Units are intended for

Commercial use only.

·

Blast Chillers carry a 3 year parts and labor

warranty; 2 additional years for the compressor.

Normal wear type parts, such as light bulbs/lamps, gaskets, fuses, batteries, blast chiller/freeze probes, thermostat or electronic controller calibration and/ or adjustment, and any normal maintenance items as outlined in the Owner's Manual, adjustment of door mechanisms or freight damage are not covered by this warranty. For this warranty, the original purchaser shall be deemed to mean the individual or company for whom the product was originally installed.

Proof of purchase must be supplied to Victory to validate the warranty. This warranty is valid only if equipment is properly installed, and started-up as outlined in the Owner's Manual.
Units that utilize variable speed compressor technology can experience nuisance tripping on Class A GFCI outlets which have a trip limit of 4 mA to 6 mA. To avoid this issue in a location that requires GFCI circuit protection, Beverage Air & Victory recommends using a HUBBELL Model Number GFRST83W 20A Heavy Duty Hospital Grade Self-Test GFCI Receptacle.
Removal or alteration of the serial/ data plate from equipment shall be deemed to release Victory from all warranty obligations or any other obligations, expressed or implied . The warranty does not cover installation, start-up, normal maintenance, food loss, or other consequential damage, and it excludes components that are removable without tools. Our obligation under this warranty shall be limited to repairing or replacing, including labor, any part of such product, which proves defective.
Victory reserves the right to examine any product claimed to be defective. The labor warranty shall be for self-contained units only and for standard straight time, which is defined as normal service rate time, for service performed during normal working hours. Any service requested outside of a servicer's normal working hours will be covered under this warranty at the normal rate and any additional overtime rate will be the responsibility of the equipment purchaser. Victory shall not be responsible for any costs incurred if the work is performed by other than Victory's authorized service personnel. Reimbursement claims for parts and/or labor service costs must be made in writing. Model, cabinet serial number and installation location must be shown on the claim. A receipted bill from the servicing agency must accompany the claim, together with full details of the service problems, diagnosis and work performed. Victory reserves sole discretion whether further documentation on a claim is to be submitted. Any part determined to be defective in the product should be returned to the company within thirty (30) days under the terms of this warranty and must be accompanied by a record of the cabinet model, serial number, with a return material authorization number (RMA#) issued by Victory.

24

Victory

Rev. 04/25

User Manual for LSF Freezer

Victory

LIMITED WARRANTY (CONTINUED)

Special installation/applications, including remote locations, are limited in coverage by this warranty. Any installation that requires extra work, and/ or travel, to gain access to the unit for service is the sole responsibility of the equipment purchaser. Improper operation resulting from factors, including but not limited to, improper or negligent cleaning and maintenance, low voltage conditions, inadequate wiring, outdoor use and accidental damage are not manufacturing defects and are strictly the responsibility of the purchaser.
Except Blast Chillers, a product is designed for maintaining temperature and not bringing food to a desired temperature, so cannot be held responsible for this function under warranty.
Units must be in conditioned environments or warranty will be void.
Condenser coils must be cleaned at regular intervals. Failure to do so can cause compressor malfunction and will void warranty. Although cleaning requirements vary in accordance with the operation of various products, Victory recommends a minimum monthly cleaning.

LIMITATION OF LIABILITY:

Victory or its affiliates shall not be liable for any indirect, incidental, special or consequential damages, or losses of a commercial nature arising out of malfunctioning equipment or its parts or components thereof, because of defects in material or workmanship. In no event shall Victory be liable for a sum more than the purchase price of the item.

THE ORIGINAL OWNER'S SOLE AND EXCLUSIVE

REMEDY AND VICTORY'S SOLE AND EXCLUSIVE

LIABILITY SHALL BE LIMITED TO THE REPAIR

OR REPLACEMENT OF PARTS OR COMPONENTS

CONTAINED IN THE EQUIPMENT IDENTIFIED

ABOVE WHICH UNDER NORMAL USE AND SERVICE

MALFUNCTION AS A RESULT OF DEFECTS IN

MATERIAL OR WORKMANSHIP, SUBJECT TO THE

APPLICABLE PROVISIONS AND LIMITATIONS STATED

ABOVE.

07/2024

NOTE: NO CLAIMS CAN BE MADE AGAINST THESE WARRANTIES FOR SPOILAGE OF PRODUCTS, LOSS OF SALES OR CONSEQUENTIAL DAMAGES. THE FOREGOING WARRANTIES ARE EXPRESSLY GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED, AND ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, AND WE NEITHER ASSUME, NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US, ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THEREOF.

These warranties shall not be assignable and shall be honored only in so far as the original purchaser.

These warranties do not apply outside the limits of the USA and Canada, nor do they apply to any part that has been subject to misuse, neglect, alteration, accident, or to any damage caused by transportation, flood, fire, acts of terrorism, or acts of God.

Rev. 04/25

Victory

25

User Manual for LSF Freezer

Victory

Warranty Registration Register your product online at Victory.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________ Business Street: ____________________________________________________ Business City: ____________________________________ State: _________ Postal Code:___________
Mail to: Victory, 3779 Champion Blvd, Winston-Salem, NC 27105 Rev. 04/25



References

Adobe PDF Library 17.0 Adobe InDesign 20.3 (Windows)