DocumentDocumentInstructions Electronic Unit for BD35/BD50F Compressors, 101N0500, 12/24V DC & 100-240V AC 50/60Hz Fig. 1 Wire dimensions DC Size AWG Cross section Gauge mm2 Max length* 12V DC operation ft. m Max length* 24V DC operation ft. m 12 2.5 8 2.5 16 5 12 4 13 4 26 8 10 6 20 6 39 12 8 10 33 10 66 20 Fig. 2 *Length between battery and electronic unit Optional battery protection settings DC Fig. 4 Resistor (9) k# 0 1.6 2.4 3.6 4.7 6.2 8.2 11 14 18 24 33 47 82 220 12V cut-out 12V cut-in V V 9.6 10.9 9.7 11.0 9.9 11.1 10.0 11.3 10.1 11.4 10.2 11.5 10.4 11.7 10.5 11.8 10.6 11.9 10.8 12.0 10.9 12.2 11.0 12.3 11.1 12.4 11.3 12.5 9.6 10.9 12V max. Voltage 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 24V cut-out 24V cut-in V V 21.3 22.7 21.5 22.9 21.8 23.2 22.0 23.4 22.3 23.7 22.5 23.9 22.8 24.2 23.0 24.5 23.3 24.7 23.6 25.0 23.8 25.2 24.1 25.5 24.3 25.7 24.6 26.0 24V max. Voltage 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 Wire dimensions AC Cross section min. 0.75 mm2 or AWG 18 Standard battery protection settings DC 12V cut-out V 10.4 12V cut-in V 11.7 24V cut-out V 22.8 24V cut - in V 24.2 Fig. 3 Compressor speed Electronic Resistor unit (8) # (calculated) Motor speed rpm Contr.circ. current mA 101N0500 0 277 692 1523 2,000 2,500 3,000 3,500 5 4 3 2 Fig. 5 ENGLISH The electronic unit is a multi voltage device. It can be used in both 12V/24V DC and 100-240V AC 50/60Hz power supply systems. Max. voltage is 17V DC for a 12V DC system and 31.5V DC for a 24V DC power supply system. Max. voltage is 265V AC and min. 85V AC for an AC power supply system. Max. ambient temperature is 55°C. The electronic unit has a built-in thermal protection which is actuated and stops the compressor operation if the electronic unit temperature becomes too high (100°C / 212°F on the PCB). Power consumption is limited to 100W. See datasheet BD50F for details. Installation (Fig. 1) Connect the terminal plug from the electronic unit to the compressor terminal. Mount the electronic unit on the compressor by snapping the cover over the screw head (1). Power supply (Fig. 1) DC: The electronic unit must always be connected directly to the battery poles (2). Connect the plus to + and the minus to -, otherwise the electronic unit will not work. The electronic unit is protected against reverse battery connection. For protection of the installation, a fuse (3) must be mounted in the + cable as close to the battery as possible. It is recommended to use 15A fuses for 12V and 7.5A fuses for 24V circuits. If a main switch (4) is used, it should be rated to a current of min. 20A. The wire dimensions in Fig. 2 must be observed. Avoid extra junctions in the power supply system to prevent voltage drop from affecting the battery protection setting. AC: The wires must be connected to the terminal marked L and N on the electronic unit. Nominal voltages from 100 to 240 VAC 50/60Hz. Upper safety cut-out limit = 270V AC and lower limit 80V AC. A 4A fuse (11) must be mounted in the live (L) cable to protect the installation. If a main switch (12) is used, it should be rated to a current of min. 6A. The wire dimensions must be min. 0.75 mm2 or AWG 18. NB: Earth connection can be used if required. General: Both the AC and the DC power supply can be connected to the electronic unit at the same time. In this case, AC will be preferred power supply source. If the AC power supply is disconnected or drop below 85V AC on a 12V DC supply system, a time delay of 1 min. will be activated before the compressor continues on DC power supply. If AC power supply is re-established there will be no delay in compressor operation. Battery protection (Fig. 1) The compressor stops and restarts again according to the designated voltage limits measured on the + and - terminals of the electronic unit. The standard settings for 12V and 24V power supply systems appear from Fig. 3. Other settings are optional if a connection which includes a resistor (9) is established between terminals C and P. See manual. Thermostat (Fig. 1) The thermostat (7) is connected between the terminals C and T. Without any resistor in the control circuit, the compressor will run with a fixed speed of 2,000 rpm when the thermostat is switched on. Other fixed compressor speeds in the range between 2,000 and 3,500 rpm can be obtained when a resistor (8) is installed to adjust the current (mA) of the control circuit. Resistor values for various motor speeds appear from Fig. 5. Fan (optional, Fig. 1) A fan (5) can be connected between the terminals + and F. Connect the plus to + and the minus to F. Since the output voltage between the terminals + and F is always regulated to 12V, a 12V fan must be used for both 12V and 24V power supply systems. The fan output can supply a continuous current of 0.5A . A higher current draw is allowed for 2 avg seconds during start. Lamp (optional, Fig. 1) A 12V DC 5 Watt lamp (10) can be connected between the terminals A and C. The output volt- age between the terminals A and C is always regulated to 12V DC. A 12V DC lamp must be used for both 12V and 24V power supply sys- tems.The lamp output can supply a continuous current of 0.5A . avg LED (optional, Fig. 1) A 10mA light emitting diode (LED) (6) can be connected between the terminals + and D. If the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash will last ¼ second. After the actual number of flashes there will be a delay with no flashes, so that the sequence for each er- ror recording is repeated every 4 seconds. Number of Error type !ashes 5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded or if the ambient temperature is high, the electronic unit will run too hot). 4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm). 3 Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)). 2 Fan over-current cut-out (The fan loads the electronic unit with more than 1Apeak). 1 Battery protection cut-out (The voltage is outside the cut-out setting). August 2011 compressors.danfoss.com - DEHC.EI.100.G6.02 / 520N0232 1/2 Instructions Electronic Units for BD Compressors VDE/UL Approvals for BD Compressors Approved Compressor - Electronic Unit Combinations Compressors BD35F mm 101Z0200 BD35F inch 101Z0204 BD35K (R600a) 101Z0211 BD50F mm 101Z1220 BD50F inch 101Z0203 BD80F mm 101Z0280 BD250GH 101Z0400 BD250GH Twin 101Z0500 BD100CN (R290) 101Z0401 Compressors BD35F mm BD35F inch BD35K (R600a) BD50F mm BD50F inch BD250GH (48V) 101Z0200 101Z0204 101Z0211 101Z1220 101Z0203 101Z0402 Standard 101N0210 UL UL UL UL Solar 101N0400 UL UL EMI 101N0220 UL UL UL UL AC/DC converter 101N0500 VDE/UL VDE/UL VDE/UL VDE/UL Electronic Units High start High speed 101N0230 101N0290 UL UL AEO 101N0300 UL UL UL UL AEO EMI 101N0320 Electronic Units Automotive Automotive 101N0600 101N0630 Telecommunication Extended EMI 101N0730 101N0900 UL VDE/UL = Combination possible, VDE or UL approval = Combination possible, but no approval = Combination not possible Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 2/2 Designed and manufactured by Secop for DANFOSS - DEHC.EI.100.G6.02 / 520N0232 August 2011