✅ Everwell MCRC-001 Instruction Manual
General Notes
Note: When the compressor is shut off, it requires 3 minutes to restart.
Key Functions and Operation Modes
Mode Selection Key: Selects the working mode. In Universal A/C Control System's auto mode, the system operates as Heat Mode if the room temperature is below 21°C, or as Cooling Mode if the room temperature is over 27°C.
Fan Selection Key: Selects the fan speed. The fan speed will be low when in Dry Mode or in Heat Mode, but the compressor has been shut off, or in Heat Mode with the compressor working for less than 3 minutes. In Auto Fan Mode, the fan speed will be high if the difference between the setting and room temperature is greater than 4°C, and low if the difference is less than 2°C.
Temperature Setting Keys: Allows setting the temperature from 15°C to 30°C. These keys do not function in Auto Mode or Dry Mode.
Timer Selection Key: Selects timer offline, timer online, or no timer.
Timer Time Setting Keys: Sets the timer duration from 1 to 16 hours.
Swing Key: Selects Swing On or Off.
Sleep Key: Will shut off the unit in 8 hours.
Too Cool/Too Warm Key: This function is only effective in Auto Mode. It allows adjustment of the setting temperature by 1°C up or down from 25°C when the key is pressed.
ON/OFF Key: Controls the unit's power On or Off.
LED Indicators
- L1 (Operation Light): Indicates the Operation Light is on, and the Indoor Fan should be blowing.
- L2 (Heating Light): Indicates the Heating Light is on, meaning the Air-Conditioner is in Heating Mode.
- L3 (Timer Light): Indicates the Timer Light is on, meaning the Equipment is in Timer Mode.
Important Reminder
In Heating Mode, within the first 30 seconds, the vane will be lifted upward to prevent cold air from blowing on people. After this period, it will restore the original settings state.
System Diagram and Control Panel Layout
Installation and Usage Notes
Please install by a certified technician and test the system before final installation.
⚠️ This Product does not work with Inverter A/C Units.
- Common Pins of the swing socket provide 12V output.
- The common pin of the step motor should be inserted into one of the common pins of the swing socket. If the direction of the step motor is incorrect, insert the common pin of the step motor into another common pin of the swing socket.
- Avoid exposing the IR receiver to strong direct light.