Instruction Manual for PPI models including: ScanLog, ScanLog 4-8 Channel Recorder with Printer Interface, 4-8 Channel Recorder with Printer Interface, Recorder with Printer Interface, Printer Interface
8 Channel With Alarm Relay Outputs - - - - Supply 2425 Analog Inputs CH-1 DEV 1 2 RS485 Comm B Alarm Outputs 9 10 11 121314 151617 1819 20 NO C NCNO C NCNO C NCNO C NC 85~265 VAC
File Info : application/pdf, 2 Pages, 461.90KB
DocumentDocumentScanLog (Printer) 4 / 8 Channel Recorder + Printer Interface OPERATOR PARAMETERS Parameters Settings (Default Value) Stop Printing Select Option No Yes 1. None 2. Print (New) 3. Re-print (Old) 4. Resume 5. Recover 6. Print Info Page (Default : None) Batch Start No Batch Stop Yes Balance Slot Time Line Per Page Read Only 25 to 100 (Default : 65) Top Margine 1 to 5 (Default : 2) Bottom Margine 1 to 5 (Default : 2) Offset Records 10 to 1000 (Default : 10) Print Page Header>> No On First Page Every Page (Default : Every Page) Delete Page Header>> No Yes Delete Page Footer>> No Yes READ USB PARAMETERS Parameters Settings (Default Value) Select Option 1. None 2. Read Set.txt File 3. Read Hdr.dat File 4. Read Ftr.dat File (Default : None) ALARM SETTINGS Parameters Settings (Default Value) Select Channel Channel-1 to Channel-4 (for 4C Printer Version) Channel-1 to Channel-8 (for 8C Printer Version) Select Alarm AL1, AL2, AL3, AL4 (The actual available options depends on the numbers of Alarms set per channel on Alarm configuration page) AL1 Type AL1 Setpoint None Process Low Process High (Default : None) Min. to Max. of selected input type range (Default : 0) Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net Parameters AL1 Hysteresis AL1 Inhibit Settings (Default Value) 1 to 30000 (Default : 20) No Yes (Default : No) DEVICE CONFIGURATION Parameters Settings (Default Value) Delete Records No Yes (Default : No) CHANNEL CONFIGURATION Parameters Settings (Default Value) All Chan Common No Yes (Default : No) Select Channel Channel-1 to Channel-4 (for 4C Printer Version) Channel-1 to Channel-8 (for 8C Printer Version) Input Type Refer Table 1 (Default : 0 to 10 V) Resolution Refer Table 1 Signal Low Input Type Settings Default 0 to 20mA 0.00 to Signal High 0.00 4 to 20mA 4.00 to Signal High 4.00 0 to 80mV 0.00 to Signal High 0.00 0 to 1.25V 0.000 to Signal High 0.000 0 to 5V 0.000 to Signal High 0.000 0 to 10V 0.00 to Signal High 0.00 1 to 5V 1.000 to Signal High 1.000 Signal High Input Type Settings Default 0 to 20mA 4 to 20mA Signal Low to 20.00 Signal Low to 20.00 20.00 20.00 0 to 80mV Signal Low to 80.00 80.00 0 to 1.25V 0 to 5V Signal Low to 1.250 Signal Low to 5.000 1.250 5.000 0 to 10V Signal Low to 10.00 10.00 1 to 5V Signal Low to 5.000 5.000 Parameters Range Low Range High Low Clipping Low Clip Val High Clipping High Clip Val Zero Offset Settings (Default Value) -30000 to +30000 (Default : 0) -30000 to +30000 (Default : 1000) Disable Enable (Default : Disable) -30000 to High Clip Val (Default : 0) Disable Enable (Default : Disable) Low Clip Val to 30000 (Default : 1000) -30000 to +30000 (Default : 0) ALARM CONFIGURATION Parameters Settings (Default Value) Alarms/Chan 1 to 4 (Default : 4) RECORDER CONFIGURATION Parameters Settings (Default Value) Normal Interval 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS) (Default : 0:00:30) Zoom Interval Alrm Toggl Rec Recording Mode 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS) (Default : 0:00:10) Disable Enable (Default : Enable) Continuous Batch (Default : Continuous) Batch Time 0:01 (HH:MM) to 250:00 (HHH:MM) (Default : 1:00) Batch Start No Batch Stop Yes RTC SETTING Parameters Settings Time (HH:MM) 0.0 to 23:59 Date 1 to 31 Month 1 to 12 Year 2000 to 2099 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net UTILITIES Parameters Settings (Default Value) Lock Unlock No Yes (Default : No) Factory Default No Yes (Default : No) Option TABLE 1 Range (Min. to Max.) Resolution & Unit Type J (Fe-K) 0.0 to +960.0°C Type K (Cr-Al) -200.0 to +1376.0°C Type T (Cu-Con) -200.0 to +387.0°C Type R (Rh-13%) Type S (Rh-10%) Type B 0.0 to +1771.0°C 0.0 to +1768.0°C 0.0 to +1826.0°C 1 °C or 0.1 °C Type N 0.0 to +1314.0°C Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type. RTD Pt100 0 to 20 mA 4 to 20 mA 0 to 80 mV Reserved 0 to 1.25 V 0 to 5 V 0 to 10 V 1 to 5 V -199.9 to +600.0°C -30000 to 30000 units -30000 to 30000 units 1°C or 0.1 °C 1 0.1 0.01 0.001 units Jan 2022 FRONT PANEL KEYS Symbol Key Scroll Function Press to scroll through various Process Information Screens in Normal Operation Mode. Alarm Acknowledge Press to acknowledge / mute alarm output (if active) & to view Alarm Status screen. DOWN Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. UP Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. SET-UP Press to enter or exit set-up mode. ENTER Press to store the set parameter value and to scroll to the next parameter. SCROLLING THROUGH VARIOUS SCREENS The screen shown below are for 4 Channel Version. The sequence is the same for 8 Channel Version. 22/09/16 CH1 OPEN CH3 27.2 10:40:06 CH2 67.4 CH4 27.2 Main Screen ** ** Recording Info Old Records 0 Pages to Print 0 Recording Information Screen ** ** Channel Names CH1 Temperature CH2 Pressure CH3 Flow Rate CH4 Motor RPM Channel Names Screen Record No = 22/09/16 Channel 1 AL 950.8 Y Channel 3 AL 43.3 Y 264 10:40:06 Channel 2 AL 43.8 Y Channel 4 AL 43.3 Y Record View Screen (Use UP / DOWN Keys to scroll through all stored records) ** ** Recording Info New Records 77 Pages to Print 2 Free Space 4194226 Recording Information Screen 22/09/16 CH1 OPEN CH3 27.2 10:40:06 CH2 67.4 CH4 27.2 Main Screen VIEWING ALARM STATUS SCREEN 22/09/16 CH1 OPEN CH3 27.2 10:40:06 CH2 67.4 CH4 27.2 Main Screen ALARM STATUS AL1 AL2 AL3 AL4 CH1 CH2 CH3 CH4 ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... Alarm Status Screen 22/09/16 CH1 OPEN CH3 27.2 10:40:06 CH2 67.4 CH4 27.2 Main Screen Analog Inputs Analog Inputs Analog Inputs Analog Inputs ELECTRICAL CONNECTIONS 4 Channel Without Alarm Relay Outputs 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 CH-1 CH-2 CH-3 CH-4 RS485 Comm DEV +B B- 12 PC +B B- 34 DC Excitation EX1 EX2 +-+- 5678 DC Excitation EX1 24V 5V EX2 24V 5V CH - X RTD TC V / mV mA 4 Channel With Alarm Relay Outputs Supply 85~265 VAC LN 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 CH-1 CH-2 CH-3 CH-4 RS485 Comm DEV PC +B B- +B B- 1234 EX 24V 5V 1 2 DC Excitation Alarm Outputs EX1 +- EX2 Relay 1 Relay 2 Relay 3 Relay 4 - + NO C NC NO C NC NO C NC NO C NC 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH - X RTD TC V / mV mA Supply 85~265 VAC LN 21 22 23 8 Channel Without Alarm Relay Outputs 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 CH-1 CH-2 CH-3 CH-4 CH-5 CH-6 CH-7 CH-8 RS485 Comm DEV B + B- 12 PC B + B- 34 DC Excitation EX1 EX2 +-+- 5678 DC Excitation EX1 24V 5V EX2 24V 5V CH - X RTD TC V / mV mA Supply 85~265 VAC LN 21 22 23 8 Channel With Alarm Relay Outputs 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 CH-1 CH-2 CH-3 CH-4 CH-5 RS485 Comm DEV PC +B B- +B B- 1234 EX 24V 5V 1 2 DC Excitation Alarm Outputs EX1 +- EX2 Relay 1 Relay 2 Relay 3 Relay 4 - + NO C NC NO C NC NO C NC NO C NC 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH-6 CH - X CH-7 RTD TC CH-8 85~265 VAC LN 21 22 23 Supply V / mV mA