Document Number : 090-01-001-DOC Rev C2 Last Changed : 18 January 2022 Author : Tai Wai Pong Copyright  SATO Vicinity 2022 Commercial in Confidence

Table of Contents
1. Overview.......................................................................................................................1 2. Features and Benefits...................................................................................................2 3. Specifications ...............................................................................................................2 4. Dimensions...................................................................................................................3 5. Connections..................................................................................................................4
5.1 J1 - Host Connector................................................................................................4 5.2 J2 - Antenna Connector..........................................................................................4 6. Antenna ........................................................................................................................5

Micro Reader MR-1 User Manual

i

090-01-001-DOC C2 18-Jan-22021

FCC Radio Frequency Interference Statement (USA)
The FCC regards RFID equipment as low-power transmitting devices and, therefore, does not require users of RFID devices to obtain a license to operate them.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
 Reorientation or relocation of receiving antenna
 Increase the separation between the equipment and receiver
 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
 Consult the dealer or an experienced radio/TV technician for help
Any changes or modifications to the equipment that are not expressly approved by the party responsible for compliance could void the user's authority granted under FCC Rules to operate this equipment. This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and all persons during normal operation. The following sentence has to be displayed on the outside of the device in which the transmitter module is installed: "Contains FCC ID: 2ACXQ-CL4NXPLUS-MR-1"
ISO/IEC 18000 ­ 3 Mode 2 (Air Interface at 13.56 MHz) Compliance
MR-1 module fully comply with the ISO/IEC18000 Part 3 Mode 2(Information technology ­ Radio frequency identification for item management. Part 3: Parameters for air interface communications at 13.56MHz) published in August, 2004.

Micro Reader MR-1 User Manual

ii

090-01-001-DOC C2 18-Jan-22021

1. Overview
The MR-1 is the smallest and simplest of Magellan's reader modules. It is intended for Original Equipment Manufacturer (OEM) applications where it is typically embedded in an RFID enabled product.
Examples include printers, hand held readers, data capture terminals, low cost desktop readers, identification and access controls.

Figure 1: MR-1 Module Rev B1

Figure 2: MR-1 Module Rev B1 with Shielding Can

Micro Reader MR-1 User Manual

1

090-01-001-DOC 18-Jan-22

2. Features and Benefits
 Low power module easy to build into RFID enabled equipment.  Small footprint.  Simple Serial UART interface.  Simple Antenna connection.
3. Specifications

Electrical Operating Frequency ISO/IEC Compliance Command Data Rate Reply Data Rate Number of Reply Channel Number of Axes Power Supply Power Supply Current

13.56MHz ISO/IEC 18000-3 Mode 2 424 kbit/s 106 kbit/s 1 (Channel `G') 1 +5.0 ± 0.5Vdc 200mA max

Host Host Interface Communications Protocol
Baud Rate Parity Data Bits Stop Bits

Serial UART
Configurable (9600 default) None 8 1

Environmental Operating Environment Temperature Range Humidity

Indoor use ­ embedded applications
0°C to +70°C ambient
10% to 80% (noncondensing)

Mechanical
External Dimensions: (L x W x H)

60 x 40 x 12.5 mm

Other Features Calibration and Tuning

No manual calibration or tuning required

Micro Reader MR-1 User Manual

2

090-01-001-DOC 18-Jan-22

4. Dimensions

4.0 56.0
60.0
60.0 Figure 3 : Major Module Dimensions (mm) Mounting Holes 4x 3.2 mm diameter

Micro Reader MR-1 User Manual

3

090-01-001-DOC 18-Jan-22

5. Connections
5.1 J1 - Host Connector
Connector Type 10 pin (JST Model S10B-PH-K-S) Reference: http://www.jst-mfg.com/product/pdf/eng/ePH.pdf

Pin Number 1 2 3 4 5
6 7 8 9 10

Function
+5 Vdc
+5 Vdc
Ground
Ground RxD UART Receive Signal (+5V TTL/ +3.3V LVCMOS) Input to module. TxD UART Transmit Signal (+5V CMOS) Output from module. Not Connected
Not Connected
Not Connected
Not Connected

5.2 J2 - Antenna Connector
Connector Type 2 pin (JST Model S2B-PH-K-S) Reference: http://www.jst-mfg.com/product/pdf/eng/ePH.pdf

Pin Number 1 2

Function RF Ground

Micro Reader MR-1 User Manual

4

090-01-001-DOC 18-Jan-22

6. Antenna

Antenna Cable Length Antenna Cable Types

50 cm maximum Twisted Pair or 50 Ohm co-ax.

Figure 4 : Dimensions of 090-10-010-ASY Ver: A 6-Turn Antenna (mm) (Equivalent for unit in SATO CG208 Printer).

Micro Reader MR-1 User Manual

5

090-01-001-DOC 18-Jan-22

Antenna Cable Length Antenna Cable Types

50 cm maximum Twisted Pair or 50 Ohm co-ax

4 - Ø5.5

17.00

5.0 92.00

10.50

9.5 5.0
Figure 5 : Dimensions of 090-10-005-ASY Ver: A 6-Turn Antenna (mm) (Equivalent for unit in SATO CL4XX and CL4NX Printer).

©2015 SATO Vicinity. All rights reserved. Specifications subject to change without notice. Any unauthorized reproduction of the contents of this presentation, in part or whole, is strictly prohibited. SATO is a registered trademark of SATO Holdings Corporation and its subsidiaries in Japan, the U.S. and other countries. All other trademarks are the property of their respective owners.