Instruction Manual for HECAPO models including: GH-PU02E Mini Split Condensate Pump, GH-PU02E, Mini Split Condensate Pump, Split Condensate Pump, Condensate Pump
Manual mini bomba condensados GH-PU02E - Hecapo
MINI CONDENSATE PUMP FOR AIR CONDITIONING (SPLIT)
MINI SPLIT CONDENSATE PUMP MANUAL ·Ultra-quiet, Overflow alarm ·Adopt the water level probe, safer and durable. 1. Product exhibition Item Parts name Inlet pipe Tank Air pipe Item Parts name connecting pipe Signal line Pump motor Item Parts name Six-core line Outlet pipe 2. Dimensions 3. Parameters Model Power supply Discharge head Flow rate Tank capacity Noise level Max air conditioner power Max water temperature 4. Flow rate Discharge head (m) Recommend to use under this discharge head Discharge head Model Performance(L/h, Head) Flow rate 5. Installation steps Connect the air pipe to the cylinder on the tank cover, as is shown. The silicon case can be took on to prevent the condensate. Make sure that the tank is horizontal, and the connection between the outlet pipe and water inlet is firmly. It's better to use the bandage to wrap it. (Equipped the inlet pipes with different shapes, please choose the proper one). As is shown. Settle the pump motor at the proper place, as is shown. Using vibration-proof material to prevent the shake from making any noise. Pay attention to the flow direction, it should be same as the arrow on the cover. water inlet water outlet Connect the tank to the pump with the equipped pipe (the length of the pipe is 1.5m, so the distance between the tank and the motor can't be over 1.5m), and use the bandage to wrap it. Connect the plastic pipe (OD 9mm*ID 6mm) to the outlet of the motor, and use the bandage to wrap it (please choose the proper length of the pipe as the matter of fact). Connect the power line of the pump which is six-core, the different functions of the lines with different colors as below: Power line: L line: red N line: green E line: yellow and green Signal line: Normally close: brown Normally open: yellow Common line: blue To prevent the overflows from the failure and resulting property loss, we advice to connect the signal line, as is shown. Normally close Common line Normally open Air conditioner indoor unit Liquid level switch Air conditioner outdoor unit Normally close Common line Normally open Air conditioner indoor unit Air conditioner outdoor unit AC contactor line line line Controller side with liquid level line line line On the controller side without liquid level, you could choose the proper AC contactor according to the air conditioner power control the power on or off. Commonly the brown is the normally close line. On the condition of overflow alarm, the yellow line closes. The normally close and open signal line is optional to connect. Correctly connected, power on the condensate pump and turn on the air conditioner. Please check if the pump works well, if not, please contact the maintainer to fix it. Notice: 1. Please pay attention to the power line and signal line, do not connect wrong. 2. Without connecting the signal line, the pump will still work normally. In order to prevent the overflow failure, we advice to connect the signal line. 6. Overflow alarm and stop function (1) When the water level in the tank is reaching the max capacity even it starts overflowing, the pump will alarm. If the signal line is connected, the air conditioner will be also cut off. (2) If the signal line is not connected, once you heard the alarm, please turn off the air conditioner and the pump right now. 7. ATTENTION! (1) Best if used in two years, after then we kindly suggest to replace a new one to prevent water leakage and property loss. (2) If the pumps are installed with the air conditioner in the ceiling, please pay attention to the condition of power failure. Without power supply, it may result in water leakage after using cool and dry mode. 8. Troubleshoot Trouble Reason Solution The tank is not horizontal The pump is always working, can't stop Any dirt inside of the tank Adjust the place and make the tank being horizontal If the tank is not cleaned up in time, please do it right now The pump starts to work and makes The water in the pump siphons loud voice No water outflows when the pump is The pipe has an air leakage working To prevent the air goes into the tank and pump when installing and operating. Make sure the breather pipe connected well. Check if there is sludge or dirt The pump can't start working The pump can't start Wrong connection Wrong power supply Check the power is well connected Check the corresponding lines are connected correctly Check if the line voltage is correct The pump gives an alarm The water level in the pump is approaching the max capacity or has overflowed Check if the outlet pipe buckled or has dirt inside Check if the air conditioner power is over the pump range The pump doesn't work, but there is water in it Each pump has to pass the test before they go out Parts of the products are recent manufactured, it may have water left. It is normal, please use it without any worry 9. Attention 1.Place the tank horizontally, do not slant it. 2.The pump needs a separate power supply, if it needs to connect to the air conditioner, refer to the wiring diagram. 3.Avoid the inlet water more than the outlet, or it may result in overflowing. 4.Do not settle the pump outside or in places where it's easy to have water flooding, to prevent danger. 5. Please hire a professional technician to install the pump. The final explanatory right is reserved by this company. Any alteration on the design and model will not be further notified.Canva iLovePDF