MINI CONDENSATE PUMP FOR AIR CONDITIONING (SPLIT)

PDF preview unavailable. Download the PDF instead.

en-4646882100-mini-bomba-condensados-gh-pu02e-manual
MINI SPLIT CONDENSATE PUMP
MANUAL
·Ultra-quiet, Overflow alarm ·Adopt the water level probe, safer and durable.

1. Product exhibition

Item

Parts name Inlet pipe Tank Air pipe

Item

Parts name connecting pipe Signal line Pump motor

Item

Parts name Six-core line Outlet pipe

2. Dimensions

3. Parameters
Model Power supply Discharge head Flow rate Tank capacity Noise level Max air conditioner power Max water temperature

4. Flow rate
Discharge head (m)
Recommend to use under this discharge head

Discharge head
Model

Performance(L/h, Head)

Flow rate
5. Installation steps
Connect the air pipe to the cylinder on the tank cover, as is shown. The silicon case can be took on to prevent the condensate.

Make sure that the tank is horizontal, and the connection between the outlet pipe and water inlet is firmly. It's better to use the bandage to wrap it. (Equipped the inlet pipes with different shapes, please choose the proper one). As is shown.

Settle the pump motor at the proper place, as is shown.

Using vibration-proof material to prevent the shake from making any noise.

Pay attention to the flow direction, it should be same as the arrow on the cover.

water inlet

water outlet

Connect the tank to the pump with the equipped pipe (the length of the pipe is 1.5m, so the distance between the tank and the motor can't be over 1.5m), and use the bandage to wrap it.

Connect the plastic pipe (OD 9mm*ID 6mm) to the outlet of the motor, and use the bandage to wrap it (please choose the proper length of the pipe as the matter of fact).

Connect the power line of the pump which is six-core, the different functions of the lines with different colors as below: Power line: L line: red N line: green E line: yellow and green Signal line: Normally close: brown Normally open: yellow Common line: blue

To prevent the overflows from the failure and resulting property loss, we advice to connect the signal line, as is shown.

Normally close
Common line Normally open

Air conditioner indoor unit
Liquid level switch

Air conditioner outdoor unit

Normally close
Common line Normally open

Air conditioner indoor unit

Air conditioner outdoor unit

AC contactor

line line line
Controller side with liquid level

line
line
line
On the controller side without liquid level, you could choose the proper AC contactor according to the air conditioner power control the power on or off.

Commonly the brown is the normally close line. On the condition of overflow alarm, the yellow line closes. The normally close and open signal line is optional to connect.

Correctly connected, power on the condensate pump and turn on the air conditioner. Please check if the pump works well, if not, please contact the maintainer to fix it.

Notice: 1. Please pay attention to the power line and signal line, do not connect wrong. 2. Without connecting the signal line, the pump will still work normally. In order to prevent the overflow failure, we advice to connect the signal line.

6. Overflow alarm and stop function
(1) When the water level in the tank is reaching the max capacity even it starts overflowing, the pump will alarm. If the signal line is connected, the air conditioner will be also cut off.
(2) If the signal line is not connected, once you heard the alarm, please turn off the air conditioner and the pump right now.
7. ATTENTION!
(1) Best if used in two years, after then we kindly suggest to replace a new one to prevent water leakage and property loss.
(2) If the pumps are installed with the air conditioner in the ceiling, please pay attention to the condition of power failure. Without power supply, it may result in water leakage after using cool and dry mode.

8. Troubleshoot

Trouble

Reason

Solution

The tank is not horizontal The pump is always
working, can't stop Any dirt inside of the tank

Adjust the place and make the tank being horizontal
If the tank is not cleaned up in time, please do it right now

The pump starts to work and makes The water in the pump siphons loud voice
No water outflows when the pump is The pipe has an air leakage working

To prevent the air goes into the tank and pump when installing and operating. Make sure the breather pipe connected well.
Check if there is sludge or dirt

The pump can't start working

The pump can't start Wrong connection Wrong power supply

Check the power is well connected Check the corresponding lines are connected correctly Check if the line voltage is correct

The pump gives an alarm

The water level in the pump is approaching the max capacity

or has overflowed

Check if the outlet pipe buckled or has dirt inside Check if the air conditioner power is over the pump range

The pump doesn't work, but there is water in it

Each pump has to pass the test before they go out

Parts of the products are recent manufactured, it may have water left. It is normal, please use it without any worry

9. Attention
1.Place the tank horizontally, do not slant it. 2.The pump needs a separate power supply, if it needs to connect to the air conditioner,
refer to the wiring diagram.
3.Avoid the inlet water more than the outlet, or it may result in overflowing. 4.Do not settle the pump outside or in places where it's easy to have water flooding, to prevent
danger.
5. Please hire a professional technician to install the pump.

The final explanatory right is reserved by this company. Any alteration on the design and model will not be further notified.

