Moxa EDS-G512E-8PoE Series Quick Installation Guide

Moxa EtherDevice™ Switch

Version 2.3, January 2021

For technical support, visit: www.moxa.com/support

© 2021 Moxa Inc. All rights reserved.

Package Checklist

The EDS-G512E-8PoE is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.

Features

Panel Views of EDS-G512E-8PoE Series

Front Panel

The front panel includes:

Top Panel

The top panel includes:

Rear Panel

The rear panel includes:

Mounting

Mounting Dimensions

Dimensions are provided in millimeters (mm) and inches (in).

Front View: Width: 79.8 [3.14] mm/in, Height: 144.8 [5.70] mm/in

Side View: Width: 143 [5.63] mm/in, Height: 137 [5.39] mm/in

Top/Bottom View: Width: 137 [5.39] mm/in, Height: 79.8 [3.14] mm/in

Rear View: Dimensions for mounting holes: 30.5 [1.20] x 15.25 [0.60] mm/in, 18 [0.71] mm/in, 68.1 [2.68] mm/in, 20 [0.79] mm/in, 33 [1.30] mm/in, 20 [0.79] mm/in.

DIN-Rail/Panel Mount Kit Dimensions: Various dimensions shown for bracket attachment.

DIN-Rail Mounting

The metal DIN-rail kit is fixed to the back panel. Mount on corrosion-free rails meeting EN 60715 standard.

Installation:

  1. Insert the upper lip of the DIN rail into the DIN-rail mounting kit.
  2. Press the EDS-G512E-8PoE series towards the DIN rail until it snaps into place.

Removal:

  1. Pull down the latch on the mounting kit with a screwdriver.
  2. Slightly pull the EDS-G512E-8PoE series forward and lift up to remove it from the DIN rail.

Wall Mounting (Optional)

For wall mounting:

  1. Remove the aluminum DIN rail attachment plate from the rear panel.
  2. Attach the wall mount plates with M3 screws.
  3. Use the unit with attached plates as a guide to mark screw locations. Ensure screw heads are less than 6.0 mm in diameter and shafts are less than 3.5 mm in diameter.
  4. Note: Before tightening, check screw suitability by inserting through keyhole apertures. Do not screw fully in; leave ~2 mm gap.
  5. Once screws are fixed, insert screw heads through wide parts of keyhole apertures, slide the unit downwards, and tighten screws for stability.

Wiring Requirements

WARNING: Do not disconnect modules or wires unless power is switched off or the area is non-hazardous. Devices must be connected to the supply voltage shown on the type plate and designed for Safety Extra-Low Voltage (SELV) in compliance with IEC950/EN60950/VDE0805.

ATTENTION: This is a built-in type unit. The enclosing equipment must comply with fire enclosure regulations (e.g., IEC 60950/EN60950).

ATTENTION: Safety First! Disconnect power before installing/wiring. Calculate maximum current for each wire and observe electrical codes. Overcurrent can cause overheating and damage.

Guidelines:

Grounding

Grounding and wire routing limit noise from electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface before connecting devices.

ATTENTION: This product is intended for mounting on a well-grounded surface, such as a metal panel.

Wiring the Relay Contact

The EDS-G512E-8PoE series has one set of relay output using two contacts on the top panel's terminal block. The FAULT contacts detect user-configured events. An open circuit occurs when an event is triggered; a closed circuit occurs otherwise.

Wiring the Redundant Power Inputs

The unit has two power inputs (Power Input 1 and Power Input 2). Wiring involves:

  1. Inserting negative/positive DC wires into the V-/V+ terminals.
  2. Tightening wire-clamp screws with a flat-blade screwdriver.
  3. Inserting the plastic terminal block connector into the receptor on the top panel.

Wiring the Digital Inputs (DI)

The unit has one set of digital input (DI) using two contacts on a 4-pin terminal block. Wiring involves:

  1. Inserting negative (ground)/positive DI wires into the /I terminals.
  2. Tightening wire-clamp screws with a flat-blade screwdriver.
  3. Inserting the plastic terminal block connector into the receptor on the top panel.

Communication Connections

Each EDS-G512E-8PoE series switch supports four types of communication ports:

USB Console Connection

Connect the Type B USB console port on the top panel to your PC's USB port using the provided USB cable. Install the USB driver and use a console terminal program (e.g., Moxa PComm Terminal Emulator) for configuration.

USB Console Port (Type B Connector) Pinouts:

Pin Description
1 D- (Data -)
2 VCC (+5V)
3 D+ (Data+)
4 GND (Ground)

USB Storage Connection

The Type A USB storage port on the front panel can be used with the Moxa ABC-02-USB-T for configuration backup, firmware upgrade, or system log file backup.

ABC-02-USB Installation:

Plug the ABC-02-USB into the USB storage port. Securing the ABC-02-USB on the wall with an M4 screw is suggested.

USB Storage Port (Type A Connector) Pinouts:

Pin Description
1 VCC (+5V)
2 D- (Data -)
3 D+ (Data+)
4 GND (Ground)

1000BaseT Ethernet Port Connection

1000BaseT data is transmitted on differential TRD+/- signal pairs over copper wires.

MDI/MDI-X Port Pinouts:

Pin Signal
1 TRD(0)+
2 TRD(0)-
3 TRD(1)+
4 TRD(2)+
5 TRD(2)-
6 TRD(1)-
7 TRD(3)+
8 TRD(3)-

100/1000BaseSFP (mini-GBIC) Fiber Port

These ports require 100M or 1G mini-GBIC fiber transceivers. The concept involves using two optical lines for full-duplex transmission: Tx from device I to Rx of device II, and Rx from device I to Tx of device II.

LC-Port Pinouts: Diagram shows Tx and Rx ports.

LC-Port to LC-Port Cable Wiring: Diagram shows A-to-A and B-to-B connections.

ATTENTION: This is a Class 1 Laser/LED product. Do not stare directly into the Laser Beam.

Reset Button

The Reset Button has two functions:

NOTE: Do NOT power off the Ethernet switch when loading default settings.

Turbo Ring DIP Switch Settings

The EDS-G512E-8PoE series uses the proprietary Turbo Ring protocol for enhanced network reliability and faster recovery times (less than 300 ms for Turbo Ring, 50 ms for Turbo Ring V2).

Four Hardware DIP Switches on the top panel configure Turbo Ring settings.

NOTE: Refer to the Communication Redundancy User's Manual for detailed information on Turbo Ring and Turbo Ring V2 settings.

EDS-G512E-8PoE Series DIP Switches

The default setting for each DIP Switch is OFF. The following tables describe the effect of setting DIP Switches to the ON position.

"Turbo Ring" DIP Switch Settings

DIP 1 DIP 2 DIP 3 DIP 4
Reserved for future use. ON: Enables this EDS as the Ring Master.
OFF: This EDS will not be the Ring Master.
ON: Enables the default "Ring Coupling" ports.
OFF: Do not use this EDS as the ring coupler.
ON: Activates DIP switch 2 and 3 to configure "Turbo Ring" settings.
OFF: DIP switch 1, 2, and 3 will be disabled.

"Turbo Ring V2" DIP Switch Settings

DIP 1 DIP 2 DIP 3 DIP 4
ON: Enables the default "Ring Coupling (backup)" port when DIP switch 3 is already enabled.
OFF: Enables the default "Ring Coupling (primary)" port when DIP switch 3 is already enabled.
ON: Enables this EDS as the Ring Master.
OFF: This EDS will not be the Ring Master.
ON: Enables the default "Ring Coupling" port.
OFF: Do not use this EDS as a ring coupler.
ON: Activates DIP switch 1, 2, and 3 to configure "Turbo Ring V2" settings.
OFF: DIP switch 1, 2, and 3 will be disabled.

NOTE: You must enable the Turbo Ring function first before using the DIP switch to activate the Master and Coupler functions.

NOTE: If no switch is enabled as Ring Master, the protocol automatically selects the one with the smallest MAC address. If multiple are enabled, they auto-negotiate.

LED Indicators

The front panel features several LED indicators. The function of each LED is described below:

LED Color Status Description
STATE Green On System passed self-diagnosis on boot-up.
Blinking 1. Switch reset progress (1 time/s).
2. ABC-02-USB connected (1 time/2s).
Red (On) System failed self-diagnosis on boot-up.
• RAM Test Fail / System Info. Read Fail / Switch Initial Fail / PTP PHY Error. (+ Green MSTR lit on: HW FAIL)
• FW Checksum Fail / Uncompress Fail. (+ Green Coupler lit on: SW FAIL)
FAULT Red On 1. Signal contact open.
2. ABC Loading/Saving Fail.
3. Port disabled due to ingress multicast/broadcast packets exceeding rate limit.
4. Incorrect loop connection.
5. Invalid Ring port connection.
Blinking Sequentially (with MSTR/HEAD + CPLR/TAIL) ABC-02-USB is importing/exporting files.
PWR1 Amber On Power supplied to main module's power input PWR1.
Off Power not supplied to PWR1.
PWR2 Amber On Power supplied to main module's power input PWR2.
Off Power not supplied to PWR2.
MSTR/HEAD Green On 1. Switch is Master of Turbo Ring, Head of Turbo Chain, or Root bridge of RSTP.
2. POST H.W. Fail (+Stat on and Fault blinking).
Blinking 1. Switch became Ring Master.
2. Head of Turbo Chain (after Ring/Chain down).
3. Turbo Chain Member with corresponding port down.
Off 1. Not Master of this Turbo Ring.
2. Member of Turbo Chain.
CPLR/TAIL Green On 1. Coupling function enabled for backup path.
2. Tail of Turbo Chain.
3. POST S.W. Fail (+Stat on and Fault blinking).
Blinking 1. Turbo Chain down.
2. Turbo Chain Member with corresponding port down.
Off 1. Coupling function disabled.
2. Member of Turbo Chain.
FAULT + MSTR/HEAD + CPLR/TAIL Rotate Sequentially ABC-02-USB is importing/exporting files.
Blinking Switch is being discovered/located by MXview (2 times/s).
10M/100M (TP) Amber On TP port's 10 or 100 Mbps link is active. Data transmitted at 10 or 100 Mbps.
Blinking (Indicates data transmission)
Off TP port's 10/100 Mbps link is inactive.
1000M (TP) Green On TP port's 1000 Mbps link is active. Data transmitted at 1000 Mbps.
Blinking (Indicates data transmission)
Off TP port's 1000 Mbps link is inactive.
100M (SFP) Amber On SFP port's 100 Mbps link is active. Data transmitted at 100 Mbps.
Blinking (Indicates data transmission)
Off SFP port's 100 Mbps link is inactive.
1000M (SFP) Green On SFP port's 1000 Mbps link is active. Data transmitted at 1000 Mbps.
Blinking (Indicates data transmission)
Off SFP port's 1000 Mbps link is inactive.

Smart PoE LED Indicators

LED Color Status Description
Smart PoE+ LED Amber On PoE port is connected to PoE device, using the 802.3af standard.
Off No PoE power output.
PoE+ LED Green On PoE port is connected to PoE device, using the 802.3at standard.
Off No PoE power output.
PoE Power Failure Indicator Red On (Once/second) PoE detection failure.
On (Twice/second) Short-circuit, overloading, or over temperature.
Off -

Specifications

Technology

Category Details
Standards IEEE 802.3af/at for Power-over-Ethernet, IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3z for 1000BaseX.
Protocols IGMPv1/v2/v3, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP, PROFINET, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTP V2, IPv6, NTP Server/Client.
MIB MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB.
Flow Control IEEE 802.3x flow control, back pressure flow control.

Interface

Category Details
RJ45 Ports 8 10/100/1000BaseT(X)
Fiber Ports 4-port 100/1000BaseSFP slot
USB Ports USB console port (type B connector), USB storage port (type A connector).
Button Reset button
LED Indicators PWR1, PWR2, FAULT, STATE, 10/100M, 100/1000M, MSTR/HEAD, CPLR/TAIL.
Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC.
Digital Input 1 input with the same ground, but electrically isolated from the electronics. +13 to +30V for state "1", -30 to +3V for state "0". Max. input current: 8 mA.

PoE

Category Details
Total Power Budget 240 W
PoE Output Voltage 46.9 VDC @ 48 VDC power input.
PoE Output Power 15.4 W in 802.3af, 30 W in 802.3at, 36 W in high power mode.
PoE Output Current 350 mA in 802.3af, 600 mA in 802.3at, 720 mA in high power mode.
Overload Current Protection at Port Present
PoE Pinout Mode A: Pair 1,2 (V+) ; Pair 3,6 (V-)

Power

Category Details
Rated Voltage 48 VDC, redundant dual inputs.
Operating Voltage 44 to 57 VDC.
Rated Current 5.42 A @ 48 VDC.
Power Consumption Max. 20.16 W full loading without PDs' consumption.
Inrush Current 11.4 A @ 48 VDC.
Electrical Isolation 2250 VDC to chassis for 60 s.
Heat Dissipation 62.2 BTU/h.
Overload Current Protection at Input Present.
Reverse Polarity Protection Present.
Connection 2 removable 4-contact terminal blocks.

Physical Characteristics

Category Details
Housing Metal, IP30 protection.
Dimension 79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in).
Installation DIN-rail mounting, wall mounting (with optional kit).

Environmental Limits

Category Details
Operating Temperature -10 to 60°C (14 to 140°F) for standard models; -40 to 75°C (-40 to 167°F) for -T models.
Storage Temperature -40 to 85°C (-40 to 185°F).
Ambient Relative Humidity 5 to 95% (non-condensing).
Altitude Up to 2000m. Note: Please contact Moxa if you require products guaranteed to function properly at higher altitude.

Regulatory Approvals

Category Details
Safety UL 508, EN 60950-1 (LVD).
EMI FCC Part 15 Subpart B Class A, EN 61000-6-4 (Industrial).
EMS EN 61000-6-2 (Industrial), EN 61000-4-2 (ESD) Level 4, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4, EN 61000-4-6 (CS) Level 3, EN 61000-4-8.
Rail Traffic EN 50121-4.
Shock IEC 60068-2-27.
Free Fall IEC 60068-2-32.
Vibration IEC 60068-2-6.

Warranty

Category Details
Warranty 5 years.

FCC Compliance

ATTENTION: This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received including interference that may cause undesired operation.
Models: EDS-G512E-8PoE Series EtherDevice Switch, EDS-G512E-8PoE Series, EtherDevice Switch

File Info : application/pdf, 16 Pages, 3.92MB

PDF preview unavailable. Download the PDF instead.

moxa-eds-g512e-series-eds-g512e-8poe-4gsfp-models-qig-v2 3

References

Adobe PDF Library 19.12.68

Related Documents

Preview Moxa Managed Switch Next Generation OS (v3.x) User Manual
Comprehensive user manual for Moxa's Managed Switch Next Generation OS (v3.x), covering installation, configuration, web interface, security, and diagnostics for models like EDS-4008 and EDS-G4014.
Preview Moxa EDS-G4012 Series Quick Installation Guide
This guide provides essential information for the installation and basic setup of the Moxa EDS-G4012 Series industrial EtherDevice switches, covering package contents, default settings, panel views, mounting, wiring, communication ports, and LED indicators.
Preview Moxa EDS-G4012 Series Quick Installation Guide - Industrial Ethernet Switch Setup
Comprehensive guide for installing and setting up Moxa EDS-G4012 Series industrial Ethernet switches. Learn about package contents, default settings, mounting options (DIN-rail, wall), wiring, communication ports, and LED indicators for reliable industrial network deployment.
Preview Moxa EDS-G4012 Series Quick Installation Guide
This guide provides essential information for the installation and initial setup of Moxa EDS-G4012 Series industrial Ethernet switches. It covers package contents, default settings, hardware overview, mounting procedures (DIN-rail and wall), wiring requirements, communication port details, LED indicator functions, Turbo Ring configuration, and technical specifications.
Preview Moxa EDS-205 Series Quick Installation Guide
Comprehensive installation guide for Moxa EDS-205 Series EtherDevice™ industrial Ethernet switches, detailing setup, wiring, panel layout, and specifications for reliable industrial network connections.
Preview Moxa EDS-405A/408A Series Quick Installation Guide
This guide provides quick installation instructions for Moxa EDS-405A and EDS-408A series EtherDevice switches. It covers product overview, package checklist, default settings, detailed panel layouts for various models, mounting instructions (DIN-Rail and wall), wiring requirements, communication port details, Turbo Ring settings, LED indicators, technical specifications, environmental limits, and regulatory approvals.
Preview Moxa EDS-2008-EL/ELP Series Industrial Ethernet Switch - Quick Installation Guide
Quick installation guide for Moxa EDS-2008-EL/ELP Series industrial Ethernet switches. Covers features, panel layout, mounting, wiring, communication connections, specifications, and regulatory approvals.
Preview Moxa EDS-518E Series Quick Installation Guide
This guide provides quick installation instructions for the Moxa EDS-518E Series EtherDevice Switch, covering package contents, features, panel views, mounting dimensions, DIN-rail and wall mounting, wiring requirements, and LED indicators.