Installation Guide for SWCORP models including: DIM-V3.4 Freestanding Bathtubs, DIM-V3.4, Freestanding Bathtubs, Bathtubs
FT-AZ202 - ANZZI Leni Series 71 in. x 38 in. Jetted Whirlpool 54 Gallon Capacity Freestanding Bathtub with Reversible Drain in White
File Info : application/pdf, 16 Pages, 3.57MB
DocumentDocumentFREESTANDING BATHTUBS INSTALLATION & OPERATIONAL MANUAL Manufactured by SWCORP 5701 NW 35th Avenue Miami, Florida 33142 DIM-V3.4 THIS LATEST MANUAL VERSION SUPERSEDES ALL PREVIOUS VERSIONS. DON'T WAIT! REGISTER NOW! and is eligible for warranty coverage. Mail in the completed registry card to 5701 NW 35th Ave Miami, FL 33142 or register online at www.SWCORP.com/register. CUT ALONG DOTTED LINE. Product Registration Card Name ..................................................................................... Address .................................................................................................................... City ............................................... State ........................... Zip .............................. Phone ........................................... Email.................................................................... Date of Purchase........................... Order or Purchase #.................................................... SKU or Model #......................................................... Installer's Name ..................................................................... Phone ................................................................................ I have read the Owner's Guide carefully and understand and agree that any installation, operation or maintenance of the bathtub must be done strictly in accordance with instructions and guidelines contained in the owner's manual and installation guide. Signature.............................................................................. Date.................................................................................. INSTALLATION INSTRUCTIONS & OWNER'S MANUAL BEFORE BEGINNING INSTALLATION, CHECK THE FOLLOWING ITEMS AND READ THE INSTRUCTIONS CAREFULLY. CHECK ENTIRE UNIT FOR CONCEALED DAMAGE. If there is any damage, DO NOT INSTALL! Shipping damages must be reported to the carrier immediately. All damage must be discovered and reported prior to installation in order to have it covered under the warranty! DAMAGE MUST BE REPORTED WITHIN 5 BUSINESS DAYS OF DELIVERY! COMPARE COLOR OF UNIT WITH OTHER FIXTURES. DO NOT INSTALL! PLANNING THE INSTALLATION 1. 3. Using the tub itself, or installation drawings, measure and mark locations for waste pipe, water supply, wiring runs, and service access. IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions and save these instructions. WARNING! WARNING! WARNING! WARNING! WARNING! damage has occurred, call our Technical Service Department at (305) 614-4070. authorization will invalidate all warranty claims. Installation must comply with current local and state building, plumbing, and electrical codes. prior to installation. Connections should be made by licensed plumbers and electrician. IMPORTANT INSTRUCTIONS: * Do Not lift by plumbing at any time! Lift by the tub deck. * Run pump only when water in tub is two inches over jets. 1 READ AND FOLLOW ALL INSTRUCTIONS 1. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times. 2. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 3. Never drop or insert any object into any opening. 4. Do not operate this unit without the guard over the suction fitting. 5. The unit must be connected only to a supply circuit that is protected by a Ground-Fault Circuit Interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI push the test button. The GFCI should interrupt power. Push the reset button. The power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. Do not use this unit. Disconnect the unit and have the problem corrected by a qualified service representative before using. 6. A green colored terminal (or a wire connector marked `G,' `GR,' `GROUND,' or `GROUNDING') is provided within the terminal compartment. To reduce the risk of electrical shock. connect this terminal or connector to the grounding terminal of your electrical service or supply panel with a continuous green insulated copper wire equivalent in size to the circuit conductors supplying the equipment. but no smaller than No.10 AWE (5.6mm) 7. A pressure wire connector on your bath is provided on the exterior of the terminal box within this unit to permit connection of a No. 8 AWE (8.4mm) solid copper bonding conductor between this unit and all electric equipment and exposed metal in the vicinity, as needed to comply with local requirements. 8. SAVE THESE INSTRUCTIONS. ATTENTION CHECK TUB FOR CONCEALED DAMAGE. CHECK COLOR COMPATIBILITY WITH OTHER FIXTURES. CHECK TO INSURE THAT THE BATH HAS THE PROPER COMPONENTS. SWCORP WILL NOT BE HELD RESPONSIBLE FOR TUB DAMAGE OR COLOR COMPATIBILITY PROBLEMS AFTER WHIRLPOOL IS INSTALLED. SWCORP WILL NOT BE HELD RESPONSIBLE FOR COST OF INSTALLATION OR REPAIR IF AN INCORRECT TUB IS INSTALLED. READ INSTRUCTIONS BEFORE STARTING INSTALLATION. 2 GENERAL NOTES CONSTRUCTION - The tub surface is made of marine grade acrylic. The substructure is a composite laminate constructed of fire retardant fillers. ELECTRICAL - Factory wired for 110 Volt 20 Amps. Ground-Fault Circuit Interrupter (GFCI) is required. The 20 Amp GFCI breaker must not supply any other circuits or devices. If and electric heater is equipped an additional dedicated 15 amp breaker is required. An access panel must be installed to permit pump service. The unit must be connected only to a supply circuit that is protected by a Ground-Fault Circut Interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI push the test button. The GFCI should interrupt power. Push the reset button. The power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. (See schematic on Pg. 5) ELECTRICAL ROUGH-IN (WARNING) When using electrical products basic precautions should always be followed including the following: Rough-in wiring to equipment on a Ground-Fault Circuit Interrupter (GFCI). The GFCI circuit breaker must not supply any other devices or circuits. Please note that depending on the therapy type of your tub, you could have multiple electrical plugs located under the skirt. Please ensure all cords are accounted for before setting the tub in place for final installation. An access panel must be installed to permit pump service. WARNING: Failure to follow instructions exposes users to risk of electrical shock or fire. PLUMBING ROUGH-IN - The bath waste pipe protrudes below the base approximately one inch. Provide supply pipe, rough-in waste and vent per local code. BATH WASTE AND OVERFLOW - Read instructions enclosed with bath waste drain for proper setting and fitting. Water tight installation of the drain is the installer's responsibility. The waste and overflow is not included with the tubs unless purchased as an option. if not purchased with the tub, you must supply and install an alternative. TESTING - Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. In the event of a problem, the unit must not be installed. SWCORP is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper inspection and testing prior to installation. INSTALLATION PROTECTION OF TUB - Use a section of the box, cut to size, and place in the bottom of the tub. When possible, keep the box cover over the tub. These steps will help protect the tub from abrasion or damage during installation. IMPORTANT: If installing a skirt with removable panel, read instructions for the skirt prior to rough-in. The instructions are located in the box with the skirt. SETTING TUB IN PLACE - The bath waste opening protrudes below the base approximately one inch. You may be required to cut a hole in the subfloor to accommodate bath waste. In slab on grade or prestressed concrete floors where cutting is not desired, the tub may be raised up by building the platform higher and using extra mortar under the tub. If a joist must be notched, verify that structure will not be weakened. Remove only what is necessary. Provide supply pipe, rough-in waste and vent per code. PLUMBING - PVC Schedule 40 piping, self draining pump and fittings come completely preplumbed unless requested otherwise. The pump and whirlpool system are completely contained within the tub perimeter. On some models, the pump may exceed beyond the perimeter of the tub. If you have such a model, please make allowances during installation. ELECTRICAL - Factory wired for 110 Volt 20 Amps. Ground Fault Circuit Interrupter (GFCI) is required. The GFCI breaker must not supply any other circuits or devices. FINISHING - Before finishing with your choice of material, make sure access entries are available to the pump, bath waste, and plumbing fixtures. Finish as desired and seal around tub, preferably with silicone. NOTE: 1. For Caulking, we recommend 100% sanitary silicone rather than latex. 2. For quieter operation, you may choose to insulate the construction area. 3. IT IS THE INSTALLERS RESPONSIBILITY TO SUPPLY ACCESS TO PUMP AND EQUIPMENT REMINDER: During construction, we suggest that you cover tub to avoid use as trash receptacle NOTE: To service the pump, blower and other electrical components the caulking must be removed. Afterwards the skirt should be cleaned and caulking reapplied. MAINTENANCE - For any maintenance or repair the shell can be removed by flipping the tub over, locating and removing the 4 plastic nubs and loosening the securing screws underneath. Then the entire shell can easily be removed. If the tub is fully installed, but must be uninstalled for maintenance or repair, the caulking must be removed completely; and the tub must be cleaned and new caulking is to be applied for reinstallation. 3 INSTALLATION CONTINUED PREPARATION 1. Clean, level and prepare the floor for installation. 2. Place the unit in the exact installed position on the floor and trace the outline of the bath with a pencil or any erasable marking (figure 1). INSTALL DRAIN HARDWARE 6. Apply a bead of clear silicone or plumbers putty around the Drain Body and pass it through the drain hole (figure 3). 7. Apply plumbers putty to the Washer and slide it over the bottom of the Drain Body (figure 3). PUTTY or SILICONE Figure 1 3. Determine the location of the drain pipe, on the floor by taking measurements of the drain and waste location underneath the unit (figure 2). Figure 3 8. Slide the paper washer over the drain body. 9. Attach the Drain Body Nut on the Drain Body and tighten until the Nut and Washer have created a seal with the bottom of the bathtub. DO NOT OVERTIGHTEN (figure 4). Figure 2 4. Using a blanket, cardboard, or other clean protective surface, turn the unit on its side so that the unit is properly supported during drain installation. 5. Clean the drain hole area in preparation of setting the drain. The area should be dry and free of any debris. 4 Figure 4 INSTALLATION CONTINUED PREPARE TAIL PIECE All parts involved in tail piece installation are provide by the installer (figure 5). 1. Drain waste vent must always be installed according to local standard. Verify the placement of the bathtub before drilling the hole for the drain waste vent. 2. Install 1 1/2 inch rubber slip gasket over the drain waste vent. 3. Cut tail piece to desired length (will vary for each installation). 4. Slide tail piece nut over tail piece towards flanged end. 5. Connect tail piece assembly to waste vent. 6. Place flange washer on top of tail piece. 5 INSTALLATION CONTINUED INSTALL BATHTUB 1. Apply a generous bead of adhesive or silicone to the bottom of the tub supports (figure 6). 2. Then apply a bead of tub and tile caulk around the edge of the base (figure 6) COMPLETE BATHTUB INSTALLATION 19. Fill the tub with water to the overflow and then drain the tub while inspecting the waste connections below the floor for leaks. Access from below will be necessary for this step (figure 8). Figure 6 3. Carefully set tub into position (figure 7) and connect the drain hardware (previously installed). Finish the installation of the tail-piece installation. Figure 8 20. With the bathtub now in place, wipe off any excess tub and tile caulk and adhesive where the tub meets the floor. 21. Run a bead of tub and tile caulk around the bottom edge of the bathtub where it meets the floor. Wipe off any excess caulk with a wet cloth (figure 9). If the tub must be uninstalled for maintenance or repair completely remove the caulking. Afterwards throughly clean the bottom of the shell and reapply caulking. Figure 7 6 CAULKING Figure 9 INSTALLATION CONTINUED PLUMBING ROUGH-IN The bath waste opening protrudes below the base approximately one inch. You may be required to cut a hole in the subfloor to accommodate bath waste. In slab on grade or prestressed concrete floors where cutting is not desired, the tub may be raised up by building the platform higher and using extra mortar under the tub. If a joist must be notched, verify that structure will not be weakened. Remove only what is necessary. Provide supply pipe, rough-in waste and vent per code. PLUMBING PVC Schedule 40 piping, self draining pump and fittings come completely preplumbed unless requested otherwise. The pump and whirlpool system are completely contained within the tub perimeter. On some models, the pump may exceed beyond the perimeter of the tub. If you have such a model, please make allowances during installation. INCOMING POWER Standard GFCI 110V, 20 Amps ELECTRICAL Factory wired for 110 Volt 20 Amps. Ground Fault Circuit Interrupter (GFCI) is required. The GFCI breaker must not supply any other circuits or devices. FINISHING Before finishing with your choice of material, make sure access entries are available to the pump, bath waste, and plumbing fixtures. Finish as desired and seal around tub, preferably with silicone. NOTE: 1. For Caulking, we recommend 100% sanitary silicone rather than latex. 2. For quieter operation, you may choose to insulate the construction area. 3. IT IS THE INSTALLERS RESPONSIBILITY TO SUPPLY ACCESS TO PUMP AND EQUIPMENT REMINDER: During construction, we suggest that you cover tub to avoid use as trash receptacle NOTE: To service the pump, blower and other electrical components the caulking must be removed. Afterwards the skirt should be cleaned and caulking reapplied. Blower Electrical Supply 7 USER GUIDE ATLANTIS TOUCH PLUS START UP AND OPERATIONAL INSTRUCTIONS Purge Cycle: There are two different purges: The first at 30 minutes after the tub is used and the second every 24 hours at the time determined by when power is turned on at the breaker box. 1. Pump On/Off: 1st Press - the pump starts 2nd Press - the pump stops 2. Blower On/Off: 1st Press - the blower starts 2nd Press - the blower stops 3. Air Jet Speed (INCREASE) 4. Air Jet Speed (DECREASE) 5. Light Button: 1st Press - turn on light 2nd Press & Hold - turn off light Cycling Colors - When turned on, Chromalight will be in Cycle Mode where the colors will slowly cycle from one to the next. To manually select your desired color, press the button again and again until the desired color is reached. It will stay on this color until turned off. 120V/60Hz Variable Blower & On/Off Pump 120V 15A Tee-Heater GROUND FAULT CIRCUIT INTERRUPTER CL ASS A Tee-Heater 120/60 8.3A ELECTRI CAL FEEDER 120V/60Hz 120V 20A for Blower/Pump GROUND FAULT CIRCUIT INTERRUPTER CL ASS A CONTROL EVO2-T -CB/L -P1B2/12/3-WD1+VB24 WATER DETECTORS FOR PUMP CHROMATHERAPY LIGHT BLUE B-CORE for Blower RED P-CORE for Pump TOUCHPAD VARIABLE BLOWER SL0-6-75- 120/60 >11A 1HP ON/OFF PUMP120/60 > 7A 8 USER GUIDE 1 2 3 4 1 HYDRO CONTROL (PUMP) 4 HYDRO JET FLOW CONTROL Used to turn the water jets ON and OFF. FOR TUBS WITH WATER JET OPTION. 2 AIR CONTROL (BLOWER) Used to increase or decrease air pressure flowing through the water jets. NOTE: On most bath tub models there are two hydro jet flow control knobs. Each knob is located on opposite Used to turn the air jets ON and OFF. FOR TUBS WITH AIR JET OPTION. 3 CHROMATHERAPY LIGHT sides of the tub as each knob controls it's respective half of the hydro jets. FOR TUBS WITH WATER JET OPTION. PRESS ONCE (when light is OFF) - Turns light ON in Auto- Cycle Mode which will slowly transition from color to color. PRESS TWICE (when light is ON)- Turns on static, non- changing color mode. Continue to press twice to move on to the next color until you find your desired choice. PRESS ONCE (when light is ON) - Turns off light. Resets cycle after 2 second pause. FOR TUBS WITH CHROMATHERAPY LIGHT OPTION. 9 FEATURES GUIDE Safety Suction Inlet that allows water to return to pump (standard on all models). If suction is blocked, the pump will automatically shutdown. Star Jet Allows user to adjust the direction pressure, by timing clock wise open flow, counter clockwise close flow. Close Open H.E.E.T. (if equipped) Maintains water temperature without a heater using kinetic energy of the water pump. Chromatherapy (if equipped) Specially designed underwater LED lights will enhance your mood upon illumination. Aromatherapy (if equipped) Open the aroma canister, drop in your favorite fragrance - turn on the blower system and you will experience an immediate sense of aromatic bliss. O3 OZone (if equipped) An O3 ozonator is an automatic device that produces ozone to safely and effectively sanitize your bath while in use. Available on whirlpool and combination systems. 10 CAUTION USER SHOULD periodically flush operating system (not to exceed 90 days). As a minimum, shall consist of filling and running system and draining. SWCORP recommends flushing with a mild solution of water and sanitizer such as chlorine or other commercially available whirlpool bath flushing products. DO NOT use abrasives. They may dull or scratch surface of the acrylic. DO NOT use oil based solvents. Clean with only a damp cloth or mild detergent or any common glass cleaner. DO NOT use bubble bath while the whirlpool is operating. DO NOT turn on pump without water in the bathtub. To do so may cause damage to the pump. DO NOT alter the position of the pump. To do so may void your warranty. NOTE: Caustic drain openers will damage the surface and the pump! Extreme heat from portable heaters and cigarettes can damage the surface of the tub. DO NOT USE OIL BASED BATH ADDITIVES. FOR MINOR SCRATCHES The procedure to remove light surface scratches or burnish marks is quite easy. Simply apply rubbing compound to the affected area and buff lightly. Then apply paste wax and gently buff again to return the original shine. CLEANING RECOMMENDATIONS To clean the pipes and pump: Fill the tub and pour a cup of bleach (or dishwasher soap [i.e. Cascade] if bleach is not available), run pump for five (5) minutes and let it sit for ten (10) minutes. Run the pump for five (5) minutes, then rinse two (2) times. Wipe off the surface after the rinse because the bleach may discolor some color trimmings. After using bleach or dishwasher soap, you should follow this cleaning procedure: Fill the tub with water and run the pump for 5 minutes, then rinse it 2 times. Clean with a soft damp cloth, do not use abrasive cleaners as they may scratch and dull surface of the unit. To clean the pipes and pump: Simple but effective, offering you complete peace of mind. Simply dilute a small amount of water with any household antibacterial cleaning agent, drop it into the aromatherapy dispenser, activate the pump and your tub is cleaned and sanitized. Also purge cycle at 30 minutes after tub is use, another every 24 hours. Standard with Air Tub. PRECAUTION HEAT STROKE - The most susceptible people are very young, the elderly, alcoholics, and most people under the influence of drugs. SYMPTOMS - Hypothermia causes loss of salt, sweating, ordinary dizziness, headache, dryness of the mouth, nausea, faintness and/or unconsciousness, convulsions, flushed appearance of the skin and rapid pulse, and/or weak or shallow breathing. TREATMENT - Place on back, head slightly elevated, apply wet cloths or ice to the head, wrap body in sheet while pouring on small amounts of water, cool shower or bath, and get medical attention as soon as possible. TROUBLESHOOTING PROBLEM SOLUTION Pump not starting Pump humming but not priming Pump not moving water No jet pressure Leak in plumbing Check wiring; Check the on/off switch; Check water level; Reset GFI at outlet. Air trapped in line; Check for clogged jets. Add water, may have to open top union. Possible obstruction in impeller. Possible frozen clutch (requires replacement). Clogged jet; air control not open; jet not open; missing part in jet. Call Tech Service: 866-588-8008 11 LIMITED WARRANTY COVERAGE READ CAREFULLY, THE WARRANTY APPLIES ONLY TO ORIGINAL OWNER 10 YEARS STRUCTURAL BATH SHELL: SWCORP warrants its bath shells against loss of water through the fiberglass laminate of the tub body as a result of a defect in materials and workmanship, for a period of ten (10) years from the purchase date. 10 YEARS SURFACE The acrylic surface is warranted against blistering, cracking and chipping resulting from a defect in the acrylic surface material for a period of ten (10) years from the purchase date. Any scratches or surface level damage must be reported within 5 business days of delivery date. ONCE TUB IS INSTALLED SCRATCHES ARE NOT COVERED UNDER WARRANTY. 1 YEAR PUMP · 1 YEAR BLOWER · 1 YEAR PARTS PLUMBING AND EQUIPMENT SWCORP warrants factory installed plumbing parts and fittings, and electrical components to be free from defect in materials and workmanship for a period of one (1) years from the purchase date, a period of one (1) years from the purchase date for the pump, and a period of one (1) years from the purchase date for the blower. EXTENT OF WARRANTY/RESPONSIBILITY OF PURCHASER This warranty applies only to original purchaser of the SWCORP. Bathtub must be registered with 90 days of delivery date to activate warranty. To register fill out the registration card in the manual and mail it to 5701 NW 35th Avenue Miami, FL 33142. Or, register online at www.SWCORP.com/ register. Original purchaser must establish, by dated sales slip, invoice or delivery receipt, the date of purchase. The warranty applies to SWCORP manufactured after October 1, 2010. WARRANTY PERFORMANCE In the event of any defect in workmanship or materials covered under the terms of the "Bath Shell" warranty, SWCORP will repair the defect and will be responsible for the labor cost incurred by its agent in doing so. Travel, trip or mileage costs incurred by the authorized agents are not covered under this warranty. SWCORP, at its sole discretion, may elect to replace the defective bath. All costs involved in replacing the unit are not covered under this warranty. In the event of any malfunction or defect covered under the terms of the "Plumbing and Equipment" warranty, SWCORP will repair or replace the defective item for a period of one (1) years from the purchase date for parts, a period of one (1) years from the purchase date for the pump, a period of one (1) years from the purchase date for the blower. Labor cost to repair an SWCORP is covered for a period of ninety (90) days, and must be performed by an certified contractor or installer. The purchaser is responsible to provide adequate access to the equipment and plumbing. Any labor costs attributed to removing decking or any other obstacle to gain easy access to the equipment or plumbing are not covered. Travel, trip or mileage costs incurred by servive technician for in-home service are not covered under this warranty. Written notice of any malfunction or defect must be given within ten (10) business days of the time it is discovered, to SWCORP, 5701 NW 35th Avenue, Miami, Florida 33142. SWCORP reserves the right to inspect the malfunction or defect on location. RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility. In the event of a problem, the unit must not be installed. SWCORP is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper inspection and testing prior to installation. Damage occurring in transit is the responsibility of the carrier. The user or installer MUST open the crate and inspect the unit for damage when it is delivered. If damage is discovered, THE TUB MUST NOT BE INSTALLED, and damages must be reported to the manufacturer within 5 business days of delivery. LIMITATIONS AND EXCLUSIONS This warranty does not cover any claim arising from abuse, misuse, negligence, accident, improper installation or operations on the part of the purchaser or installer. This warranty is void if the SWCORP is subject to alteration, or if repairs are attempted by anyone other than an authorized agent of SWCORP. This warranty does not extend to plumbing or components installed by dealers, installers or by any party other than SWCORP. SWCORP will not be liable for loss of use of the product, inconvenience, or any other incidental or consequential costs, expense or damages. Please note that some states do not allow the exclusion or limitation of incidental damages. Additionally, this warranty does not cover discontinued or display products. DISCLAIMER Except as expressly provided, there shall be no warranty or obligation, express or implied, oral or statutory. No dealer or other person has the authority to make any warranties or representations concerning SWCORP or its products. In no event shall SWCORP be held responsible for any such warranties or representations. OTHER RIGHTS This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. TECHNICAL SERVICE Contact the retail seller or the local authorized warranty service center. If you do not know who your local representatives are, contact SWCORP Service Department at the address listed below, or call (305) 614-4070. Tel: 1-866-588-8008 / Fax: 1-866-560-1060 www.SWCORP.com / info@swcorp.com 5701 NW 35 Avenue, Miami, FL, 33142 This warranty is in effect as of May, 2019. This warranty supersedes all previous warranties and/or claims both stated and implied. This warranty is subject to change without notice. 12 NOTES 13 IMPORTANT: INSTALLER: HOMEOWNER: READ AND SAVE THESE INSTRUCTIONS. SAVE INSTALLATION INSTRUCTIONS WITH HOMEOWNER KEEP INSTALLATION INSTRUCTIONS FOR FUTURE REFERENCE Please leave owner's manual with warranty. If you have any problems or questions during installation, please call technical service at (305) 614-4070 Record the numbers here for handy reference: Model No. Serial No. Date of Purchase Manufactured by SWCORP 5701 NW 35th Avenue Miami, Florida 33142 Ph: (305) 614-4070 · Fax: 1-866-560-1060 Email: info@swcorp.com Visit: www.SWCORP.com