Installation Guide for Mircom models including: TX3-IP-NP-256, Telephone Access System Module

LT-5997-256 TX3-IP-NP-256 Installation

janderson

LT-5997-256-TX3-IP-NP-256-Installation-rev-0

Product – Mircom

LT-5997-256 TX3-IP-NP-256 Installation (English)

2000 Resident Building Access Control System

Hands Free Building Telephone Entry Systems - Mircom


File Info : application/pdf, 4 Pages, 1.23MB

PDF preview unavailable. Download the PDF instead.

LT-5997-256-TX3-IP-NP-256-Installation-rev-0
TX3-IP-NP-256 Installation
These instructions explain how to install the TX3-IP-NP-256 in the following TX3 units: TX3-2000-8U-C-256 TX3-2000-8C-C-256
A. Contents of Kit
· TX3-IP-NP-256 · 2 Nuts for attaching TX3-IP-NP-256 to the TX3 unit · USB cable for programming TX3-IP-NP-256 · USB flash containing TX3 software and manuals
B. Mount TX3-IP-NP-256
1. Mount TX3-IP-NP-256 on the two posts as shown in Figure 1. 2. Secure it with the provided nuts.
Nut

Nut

TX3-IP-NP-256

Figure 1 Mount TX3-IP-NP-256

1

LT-5997-256 Rev 0 March 2022

Subject to change without notice. See http://www.mircom.com for the latest information

C. Wiring WARNING: Disconnect the power before wiring.
· RS-485 wiring maximum total length: 1219.2 m (4000 ft) · PoE maximum length: 100 m (328 ft)

Figure 2 Wiring TX3-IP-NP-256
D. DIP Switch
· Use DIP switches 1-6 (shown in Figure 1) to set the RS-485 network address.

Figure 3 Set the RS-485 address
Note: You must set the RS-485 address even if you are not using RS-485.
· DIP switch 7: keep off. · DIP switch 8: Set open (off) to get an IP address from the DCHP server, and set closed
(on) to set a fixed IP address using the TX3 Configurator software. The default setting is off. For more information and the complete list of RS-485 addresses, see LT-980, the TX3 Card Access System Manual, on the Mircom website (www.mircom.com) or the USB flash.

LT-5997-256 Rev 0 March 2022

2

Subject to change without notice. See http://www.mircom.com for the latest information

E. RS-485
Connect the RS-485 input terminal to the RS-485 output terminal of another controller. See Figure 4. Set the 120 switch ON (shown in Figure 2) if unit is used as first or last controller on RS-485 network. Otherwise set OFF. The default setting is OFF. Note: Use twisted shielded pair. Recommended cables:
· RS485 cables · Belden 3109A RS-485, (4 pr) 22 AWG (7x30) or equivalent · Belden 9842 RS-485, (2 pr) 24 AWG (7x32) or equivalent · Belden 9841 RS-485, (1 pr) 24 AWG (7x32) or equivalent
· CAT5 Cables · Belden 72001E ETHERNET Cat 5e 2 Pair, 24 AWG or equivalent · Belden 70006E Cat 5e, 100Mb/s, Quad, AWG 22 (1) or equivalent
Maximum total length: · 4000 feet (1244 m) for 22 AWG · 2500 feet (762.5 m) for 24 AWG
First controller on network Turn switch labeled "120 " ON

Turn switch labeled "120 " OFF

Last controller on network Turn switch labeled "120 " ON
Figure 4 RS-485
F. USB Port
The USB port provides a connection to a PC, for configuring the Card Access System and upgrading the firmware.
G. Power
The Single Door Controller can be powered in three ways. Use only one of the power inputs. · Power over Ethernet (PoE) - use Cat 5 cable · 12 VDC/15 W - use 18 AWG · 24-48 VDC/15 W - use 20-18 AWG

3

LT-5997-256 Rev 0 March 2022

Subject to change without notice. See http://www.mircom.com for the latest information

H. Example Network Diagram

Use TX3-IP-NP-256 IP Gateway to connect TX3 devices to an Ethernet network. The IP Gateway is a bridge between RS-485 on the device side, and Ethernet on the network side.

Legend: RS-485 Ethernet

TX3-2000-8U-C-256 (Main Node)

TX3-TOUCH-S15-C (Secondary Node)

1

2

3

ABC

DEF

4

5

6

GHI

JKL

MNO

7 PQRS

8

9

TUV

WXYZ

*0#

TX3-CX-2-A-256 (Secondary Node)

TX3-IP-256/ TX3-IP-NP-256
Router/ Switch

TX3-2000-8U-C-256 (Main Node)

RS-485 Subnetwork

TX3-ER-8-B-256 (Secondary Node)

TX3-CX-2-A-256 (Secondary Node)

1

2

3

ABC

DEF

4

5

6

GHI

JKL

MNO

7 PQRS

8

9

TUV

WXYZ

*0#

TX3-IP-256/ TX3-IP-NP-256

RS-485 Subnetwork

Figure 5. TX3 devices on a mixed network with TX3-IP-NP-256

LT-5997-256 Rev 0 March 2022

4

Subject to change without notice. See http://www.mircom.com for the latest information



References

Acrobat Distiller 21.0 (Windows)