Installation Guide for Altronix models including: AL624E Linear Power Supply Charger, AL624E, Linear Power, Supply, Charger

IIAL624E F21U

AL624E Linear Power Supply/Charger Installation Guide

Click to View

Altronix AL624E | Linear Power Supply Charger, Single Class

PDF preview unavailable. Download the PDF instead.

AL624E
AL624E Linear Power Supply/Charger

Installation Guide
Overview:
Altronix AL624E Linear Power Supply/Charger converts a low voltage AC input to a low voltage DC output. This general purpose power supply has a wide range of applications for access control, security and CCTV system accessories that require additional power.

Specifications:

Agency Listing: · CE European Conformity.
Input: · Input 16VAC to 24VAC, 20VA to 40VA
(Voltage Output/Transformer Selection Table)
Output: ·Switch selectable 6VDC-12VDC-24VDC. · 1.2A continuous supply current at 6VDC-12VDC. · 750mA continuous supply current at 24VDC. · Filtered and electronically regulated output.

Battery Backup: · Built-in charger for sealed lead acid or
gel type batteries. · Maximum charge current 300mA. · Automatic switchover to stand-by battery when
AC fails. · PTC battery protection.
Additional Features: · Thermal and short circuit protection with auto reset. · AC input and DC output LED indicators. · Extremely compact design. · Includes battery leads and enclosure.

Enclosure Dimensions (H x W x D): 8.5" x 7.5" x 3.5" (215.9mm x 190.5mm x 88.9mm).

Voltage Output/Transformer Selection Table:

Output (continuous supply current)
6VDC @1.2A 12VDC @ 1.2A 24VDC @ 750mA

Voltage Selector (JMPR) Transformer

Cut Jumper J2 Only Leave J1 & J2 Intact Cut Jumper J1 Only

12VAC / 20 VA (Altronix model TP1220) 16.5VAC / 20 VA (Altronix model TP1620) 24VAC / 40 VA (Altronix model TP2440)

Installation Instructions:
1. Mount AL624 into enclosure (Fig. 1, pg. 2). 2. Mount AL624E in desired location. 3. Unit is factory set for 12VDC. For 6VDC output cut jumper J2, for 24VDC output cut Jumper J1. 4. Connect proper transformer to terminals marked [AC] (Voltage Output/Transformer Selection Table).
Use 18 AWG or larger for all power connections (Battery, DC output). 5. Measure output voltage before connecting devices. This helps avoiding potential damage. 6. Connect devices to be powered to the terminals marked [+ DC] and [DC ­ BAT] carefully observing polarity. 7. Connect battery to the terminals marked [BAT +] and [DC ­ NEG] (battery leads included).
Note: When batteries are not used, a loss of AC will result in a loss of output voltage.

Red (DC) ON ON OFF OFF

Green (AC) ON OFF ON OFF

LED Diagnostics:
Power Supply Status Normal operating conditions Loss of AC. Stand-by battery is supplying power. No DC output. Short circuit or thermal overload condition. No DC output. Loss of AC. Discharged or no battery present.

Terminal Identification:

Terminal Legend Function/Description

AC/AC

Low voltage AC input (Voltage Output/Transformer Selection Table, pg.1).

+ DC ­

6VDC or 12VDC @ 1.2A continuous supply current.

­ BAT +

Stand-by battery connections. Maximum charge rate 300mA.

Fig. 1

FACTORY SET AT 12V CUT J1 FOR 24V CUT J2 FOR 6V J1
J2

STEP 1:

Use these holes to mount AL624 by pushing the nylon circuit board fasteners (Fig. 1a) through the back of the enclosure. Nylon fasteners will snap into place.

AC

DC

AC AC +DC - BAT +

STEP 2: Mount AL624 circuit board to nylon fasteners by pressing down circuit board onto nylon fasteners.
Note: Springlock on fasteners is used to remove AL624 circuit board.
Note: Four (4) fasteners are provided in the AL624 carton.

Springlock

Fig. 1a Nylon Fastener

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty

IIAL624E - Rev. 091211