Owner's Manual for KOHLER models including: K-4991-ER Bardon High Efficiency Urinal, K-4991-ER, Bardon High Efficiency Urinal, High Efficiency Urinal, Efficiency Urinal, Urinal

K-4991-ER

Kohler Co.


File Info : application/pdf, 2 Pages, 160.37KB

K-4991-ER spec US-CA Kohler en
Features
· Washout urinal · 3/4" (19 mm) rear spud · 0.125 - 1.0 gpf (0.47 - 3.8 lpf) · Will replace K-4904-ER
Material
· Vitreous china
Installation
· 14" (356 mm) extended rim
Recommended Products/Accessories
K-23726 Drain treatment K-23725 Cast iron cleaner K-4929 Waterless Urinal Maintenance Balls

BardonTM
High-Efficiency Urinal K-4991-ER
Codes/Standards
ASME A112.19.2/CSA B45.1 DOE - Energy Policy Act 1992 EPA WaterSense® California Energy Commission (CEC) ADA ICC/ANSI A117.1 CSA B651 IAPMO Certification
KOHLER® One-Year Limited Warranty
See website for detailed warranty information.
Available Colors/Finishes
Color tiles intended for reference only. Color Code Description
0 White

1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada 6-13-2024 20:25 - US

BardonTM
High-Efficiency Urinal K-4991-ER

3/4" Spud
20-3/4" (527 mm)
2" NPT Tap

19" (483 mm)

26-7/8" (683 mm)

18" (457 mm)
12" (305 mm)

Wall Hangers
40-1/2" (1029 mm) To Floor

21" (533 mm) Standard Installation 13" (330 mm) Max ADA, CSA B651 Installation

14-1/8" (359 mm)

24" (610 mm) Standard Installation 17" (432 mm) Max ADA Installation 16-7/8" (429 mm) Max CSA B651 Installation

2" NPT Tap
1/4" (6 mm)

6" (152 mm)

Floor

Outlet Detail

Technical Information
All product dimensions are nominal.

Spud size:

3/4", Inlet, Rear

Min. Water per

0.125 gpf (0.5 lpf)

Flush:

Max. Water per

1 gpf (3.8 lpf)

Flush:

Designed for the above water use when installed with a

water-saving flushometer.

Notes
Install this product according to the installation guide.
Refer to manufacturer's instructions and local codes for flushometer requirements.
Recommended ADA outlet spud height will account for normal product variation.
For ADA compliance, measurement must be 17" (432 mm) or less from the floor to the top of the lip. For CSA B651 compliance, measurement must be 16-7/8" (429 mm) or less from the floor to the top of the lip.
ADA, CSA B651 compliant when installed to the specific requirements of these regulations.

1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada 6-13-2024 20:25 - US

