User Manual for Remotec Technology models including: ZXT-800 Z-Wave to IR AC and AV Extender, ZXT-800, Z-Wave to IR AC and AV Extender, AC and AV Extender, AV Extender, Extender

Z-Wave to IR AC & AV Extender – Remotec Technology

ZXT-800 AC/AV MASTER USER MANUAL - remotec.co

ZXT-800 AC/AV MASTER USER MANUAL 3. GetStarted User Guide × 1 ZXT-800 × 1 3.1 Step-1ApplyPowertoZXT-800 • 3 × AAA batteries or Micro USB • ZXT-800 will detect the first applied power source to decide what Z-Wave™device


File Info : application/pdf, 26 Pages, 3.13MB

PDF preview unavailable. Download the PDF instead.

ZXT-800 USER MANUAL V1.0
ZXT-800 AC/AV MASTER USER MANUAL
APPs Download: Conexum ZXT-800

CONTENTS

1 Introduction

1

2 Product Overview

1

2.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.3 Z-Wave Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3 Get Started

4

3.1 Step-1 Apply Power to ZXT-800 . . . . . . . . . . . . . . . . . . . . . 4

3.2 Step-2 Include ZXT-800 to a Z-WaveTMGateway . . . . . . . . . . . . 5

3.3 Step-3 Setup Automatic Status Report Associate to Gateway . . . . 6

3.4 Step-4 Setup IR code . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.5 Setup IR Code by ZXT-800 App (AC+AV) . . . . . . . . . . . . . . . . 9

3.6 IR Code learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

4 Configuration Master Table

15

5 Reset to Factory Default

18

6 Mounting and Placement

19

7 Technical Specifications

20

8 BLE Channels and Frequency

21

9 Warranty

22

10 Regulatory information

23

11 IC Notice

24

12 Warnings

24

13 Caution

24 Version: 1.0

1. Introduction

ZXT-800 AC/AV MASTER USER MANUAL

ZXT-800 is a Z-WaveTMplus compliant Z-WaveTM-to-IR Bridge to control split air conditioner and entertainment devices by receiving Z-WaveTMcommand and translating to Infrared command. With its comprehensive built-In and cloud-stored IR database (library). ZXT-800 can control different brands and models of infrared devices worldwide.
ZXT-800 is a security enabled Z-WaveTMplus device. A security Enabled Z-WaveTMPlus Controller must be used in order to fully utilize the feature.
ZXT-800 is a Z-WaveTMslave device, it can be up to gateway to setup particular brand with correct IR code. User can setup the IR (AV + AC) code by "Conexum ZXT-800" App through Bluetooth download. iOS and Android App are available in Apps store.

2. Product Overview
2.1 Description
Temperature sensor Battery door

Red and Blue LEDs indicator Mounting hole

Micro USB External IR Port "PROG" Button
 Continued on next page

CONTENTS

[ 1 | 24 ]

2.2 Features

ZXT-800 AC/AV MASTER USER MANUAL

· Working as a Z-WaveTMthermostat (AC) and Simple AV device · Supports Classic Inclusion, NWI and SmartStart · Built-in AC IR database for worldwide market, direct use it in gateway · Cloud-base downloadable AC + AV IR library by Smart phone · Supports Basic, Smart and Learning search in Smart Phone App · Support IR learning · Supports AC × 1 and AV × 3 by download · Built-in temperature and humidity sensor · Support firmware upgrades via Over-the-air (OTA) by Z-WaveTMand BLE · Z-WaveTMPlus 2 compliant · Working on battery (3 × AAA batteries) or USB power · This product can be operated in any Z-WaveTMnetwork with other Z-WaveTMcertified
devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. · SmartStart enabled products can be added into a Z-WaveTMnetwork by scanning the Z-WaveTMQR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

 Continued on next page

CONTENTS

[ 2 | 24 ]

2.3 Z-Wave Glossary

ZXT-800 AC/AV MASTER USER MANUAL

Device or Node Inclusion Exclusion Remove
Network Wide Inclusion (NWI)
Z-Wave Network
Indicator Command
FLiRS Mode
AlwaysListening Mode
Association Thermostat
mode

Devices and nodes are all terms to describe an individual Z-WaveTMdevice. These are all interchangeable when setting up your Z-WaveTMnetwork. Add a Z-WaveTMdevice to the network. Remove a Z-WaveTMdevice from the network. Remove a Z-WaveTMdevice from the network. Network Wide Inclusion (NWI) enables both end-user friendly, Plug and Play like Z-WaveTMnetwork installation as well as professional installation scenario where the inclusion process, in terms of time will be reduced significantly. NWI is a feature supported by a new frame type named Explorer which enables the Z-WaveTMprotocol to implement Adaptive Source Routing. A collection of Z-WaveTMdevices is controlled by primary and secondary controllers operating on the same system. A Z-WaveTMnetwork has its own unique ID code so that controllers not in the network cannot control the system. The device supports the Indicator Command Class and support the Indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05 FLiRS is abbreviation for "Frequently Listening Routing Slave". FLiRS mode is targeted for battery operated applications and will enter sleep mode frequently in order to conserve battery consumption. The response to Z-WaveTMcommand is not as quick as Always Listening Device. Normally there is 1-2 seconds latency. Always Listening Mode is targeted for AC power operated applications and it can act as a repeater, which will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots. The response to Z-WaveTMcommand is immediate. Association is used to organize nodes in different groups allowing the device to identify the nodes by a group identifier. The groups can also be copied to other devices. Thermostat may support mode: OFF / HEAT / COOL /AUTO/ RESUME(ON)/ FAN ONLY /DRY AIR which depends on AC code.

CONTENTS

[ 3 | 24 ]

3. Get Started

ZXT-800 AC/AV MASTER USER MANUAL

User Guide × 1 ZXT-800 × 1

3.1 Step-1 Apply Power to ZXT-800
· 3 × AAA batteries or Micro USB · ZXT-800 will detect the first applied power source to decide what Z-WaveTMdevice
role it will be in after included into the Z-WaveTMgateway: ­ Battery = sleeping device (FLiRS mode) ­ USB power = always awake device (Always Listening mode)
Please refer to Z-WaveTMGlossary for more information. · Once the ZXT-800 is included into a Z-WaveTMnetwork, the working mode (sleep-
ing or awake) cannot be changed, unless it is excluded and re-apply the power. · ZXT-800 can be included and operated in any Z-WaveTMnetwork with other Z-
WaveTMcertified devices from other manufacturers and/or other applications. All non-battery operating nodes within the network will act as repeaters regardless of Vendor to increase reliability of the network.
Caution
· Use new batteries of the recommended type and size only. · Never mix used and new batteries together. · To avoid chemical leaks, remove batteries from the ZXT-800 if you do not in-
tend to use the device for an extended period of time. · Dispose of used batteries properly; Do not burn or bury them.

CONTENTS

[ 4 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.2 Step-2 Include ZXT-800 to a Z-WaveTMGateway

There are two methods to include to a Z-WaveTMnetwork,

Classic inclusion

Step 1
2

Procedure / Description Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode Once the primary controller is ready to include/exclude the device, press the "PROG" button once.

Status Indicator
-
Blue LED will flash until complete the step of inclusion / exclusion. If success, blue LED will flash twice; if fail, red LED will flash twice.

SmartStart inclusion

Step 1

Procedure / Description Refer to your primary controller (gateway) instruction then use Smart Phone App to scan ZXT-800 SmartStart QR code, it will include the device into the Z-WaveTMnetwork automatically. User can find out the QR code at device bottom Z-WaveTMDSK area. Make sure your gateway supports SmartStart feature.

Status Indicator
Blue LED will flash until complete the step of inclusion / exclusion. If success, blue LED will flash twice; if fail, red LED will flash twice.

Notes
· It is recommended to perform the Remove (Exclude) procedure before per-forming an Add (Include) procedure.
· If the Add (Include) process fails, try to Remove (Exclude) from your primary controller (or reset the ZXT-800 to Factory Default), then repeat the above steps.

 Continued on next page

CONTENTS

[ 5 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.3 Step-3 Setup Automatic Status Report Associate to Gateway
Please refer to your primary controller (gateway) instruction for more detail. Normally, User can ignore this step during the setup. ZXT-800 support 1 association group, Association Group #1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for ZXT-800 status change report, refer to below for report details:
· Current Room Temperature (report in precision of 0.5°C or 1°F), It will be according to Configuration Parameter 30 setting to decide the trigger level.
· Current Battery Level (Only apply in Low Battery Warning happened) · Device Reset Locally Notification (Only report when the ZXT-800 has been trig-
gered the RESET TO DEFAULT)
3.4 Step-4 Setup IR code
The user interface of setup the IR code varies from different gateways. If gateways have dedicated UI for the IR code setup, please refer to the gateway UI and ignore the below steps. If your gateway does not have dedicated UI for ZXT-800 IR code setup, but support Z-WaveTMConfiguration Command Class. Please refer to below method-A to setup the IR code using the configuration options in your gateway.
 Continued on next page

CONTENTS

[ 6 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
There are two methods A) and B) to set up IR code:

A) By Z-WaveTMgateway configuration (Setup AC code with internal library)

Step 1 2
3

Procedure / Description Refer to your primary controller user manual, enter Configuration setting. Set up IR code with internal library, Input parameter number: 27, Input parameter value: XXXX (AC code no.); User can scan product QR code (near the Z-WaveTMlogo) which will reach to our Code Finder Webpage, it obtains a list of AC codes. Example: AC IR code number: 13; Parameter no.: 27 (Setup IR code); Parameter value size: 2 bytes; Parameter value: 0013 (AC code number); Then activate or save it in gateway. Once you finished the IR code setup, please go back to the control page of ZXT-800 on the gateway's Browser or App. Try the function such as (Cool, Temperature Set). If the Air Conditioner does not respond to the command you set on the Gateway (Cool, Heat, Auto, Temperature Set, etc.), repeat step 2 to step 3. Select the next IR code for test from the code list.

Status Indicator -
Purple LED will turn on. If success, blue LED flash ONCE; If fail, red LED will flash TWICE.
Red LED flashing ONCE if device sends out one IR.

Important Notes
· Above procedures are for AC code configuration only. · Different brand or model of air conditioner has different function. For example,
some air conditioner only support temperature set from 10°C - 30°C, if user set 17°C on gateway, ZXT-800 will not respond it. · There are more than 1 code for each brand, some does not support Heat, if User selected a code that does not support Heat but original air conditioner supports Heat Function, please continue to try next code until the correct one is selected. · It is not allowed to set up the IR Code when the battery level below 20%. · You can record down your Device Code for future reference after setting up the ZXT-800 correctly. · AC code set:

CONTENTS

[ 7 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
B) By Smart Phone App "Conexum ZXT-800" (Setup AC + AV with cloud library)
User can download "Conexum ZXT-800" App to implement Basic Search for AC and Smart Search for AV then setup the IR code. ZXT-800 supports AC × 1 and AV × 3 devices storage memory. Once your IR code setup completed, user should add ZXT-800 into the Z-WaveTMnetwork then control it directly.
Please make sure Z-WaveTMgateway support AV control interface when you setup AV control. For more detail operation, please refer to below section.
 Continued on next page

CONTENTS

[ 8 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.5 Setup IR Code by ZXT-800 App (AC+AV)
1. Please install "Conexum ZXT-800" App, turn on the "Bluetooth" and "GPS", "WiFi / 4G" on the Smart phone. The App is available in Google Play & Apple App Store.
2. Pair with ZXT-800 by Smart Phone BLE · Open the App and follow the Smart phone setup UI. · Press "Add extender". · Trible click on the PROG button within 1.0s to pair with Smart Phone, blue LED will keep flashing. · In Smart Phone, please select "Conexum unit" that you want to pair it. · Once BLE pairing completed, blue LED will turn off.
3. IR code set up · For AC setup, please type-in or select your brand then follow the Basic Search to test it one by one. · For AV setup, please select your device type (TV, CBL, B-Ray, Soundbar), brand then follow the Smart Search steps to test it. · Once you have successfully found an IR Code that matches your device, tap to confirm the code and download it into the ZXT-800.

AC Basic search

AV Smart Search

4. After IR code setup completed, please refer to Z-WaveTMinclusion and add ZXT800 into the Z-WaveTMnetwork, then go to your Z-WaveTMcontrol panel for device

CONTENTS

[ 9 | 24 ]

control directly.

ZXT-800 AC/AV MASTER USER MANUAL

3.6 IR Code learning

In case the IR code can't support full keys controls, user can use the IR learning function to capture the IR data from original remote controller, please follow below steps.

AC IR Code Learning

Please refer to "Configuration Master Table" for all configuration settings.

Step 1 2
3
4

Procedure / Description

Refer to your primary controller user manual, enter

Configuration setting.

To learn AC IR code, look up AC Learning Mapping Table

for learning and decide which IR setting you wants to

learn, example:Parameter number: 25 (Learn AC IR

code) Parameter value size: 1 byte Parameter value: 5

(Cool mode, 20°C) Then activate or save it in gateway.

Learning location:

Adjust your original AC remote

to Cool mode 21°C, aim your

original AC remote to ZXT-800

according to above position

Infrared receiving area

within 1-3cm. Press and release temperature down button to

adjust to 20°C, ZXT-800 will learn the IR code

automatically. If the learning is failed or need to learn

next IR code, repeat step 2 to step 3.

Once you finished the IR Code Learning, please go to

Configuration setting page on the Gateway. Parameter

number: 27 (Set IR code) Parameter value size: 2 bytes

Parameter value: 0000 (AC learning location) Then

activate or save it in gateway. ZXT-800 will set the code

number to "0000" which is AC learning code location.

Status Indicator Then Red LED turns ON for indicating the IR Code Learning
Successful: Blue LED flashes TWICE; Unsuccessful: Red LED flashes TWICE
-

CONTENTS

 Continued on next page
[ 10 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
TIPS 1. User need at least Learn the OFF (Parameter Value 0), and one Temperature
Mode (Parameter Value 2  28) to complete the usage model. 2. Keep away from Incandescent Light or Direct Sunlight during learning. 3. Make sure IR Transmitter of your Original Remote alight with learning diode
of ZXT-800, you may also slight adjust closer or further away the distance of two devices. Some of Remotes the IR transmitter in hidden behind lens and may not installed center of remote. 4. Make sure the power is good on both devices, especially the Original remote. Use Fresh Batteries in both devices recommended. ZXT-800 will not implement the learning process if the battery level below 20%.
 Continued on next page

CONTENTS

[ 11 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL

Parameter-Value (Storage Location)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Thermostat Command & IR Setting

Storage in Celsius Unit Storage in Fahrenheit Unit

OFF

OFF

ON (RESUME)

ON (RESUME)

17°C Cool

63°F Cool

18°C Cool

64°F Cool

19°C Cool

66°F (67°F Cool)

20°C Cool

68°F (69°F Cool)

21°C Cool

70°F (71°F Cool)

22°C Cool

72°F (73°F Cool)

23°C Cool

74°F (75°F Cool)

24°C Cool

76°F Cool

25°C Cool

77°F (78°F Cool)

26°C Cool

79°F (80°F Cool)

27°C Cool

81°F (82°F Cool)

28°C Cool

83°F (84°F Cool)

29°C Cool

85°F Cool

30°C Cool

86°F Cool

17°C Heat

63°F Heat

18°C Heat

64°F Heat

19°C Heat

66°F (67°F Heat)

20°C Heat

68°F (69°F Heat)

21°C Heat

70°F (71°F Heat)

22°C Heat

72°F (73°F Heat)

23°C Heat

74°F (75°F Heat)

24°C Heat

76°F Heat

25°C Heat

77°F (78°F Heat)

26°C Heat

79°F (78°F Heat)

27°C Heat

81°F (82°F Heat)

28°C Heat

83°F (84°F Heat)

29°C Heat

85°F Heat

30°C Heat

86°F Heat

Dry Mode

Dry Mode

Auto Mode

Auto Mode

Fan Mode

Fan Mode

Table 1: AC IR Learning Mapping Table (Parameter number 25)

CONTENTS

[ 12 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
Mapping Information 1. BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00 2. BASIC Set Value 0xFF will map to Thermostat mode Resume 0x05 3. Energy Saving Mode will map to Thermostat mode OFF

AV IR Code Learning

Please refer to "Configuration Master Table" for all configuration settings.

Step 1 2 3
4

Procedure / Description

Refer to your primary controller user manual, enter

Configuration setting.

Select AV endpoint (learning location), example:

Parameter number: 38 (Select AV endpoint); Parameter

value size: 1 byte; Parameter value: 2 (AV1); Then

activate or save it in gateway.

To learn AV IR code, look up AV Learning Mapping Table

for learning and decide which IR setting you wants to

learn, example: Parameter number: 26 (Learn AV IR

code); Parameter value size: 1 byte; Parameter value: 11

(VOL+); Then activate or save it in gateway.

Learning location:

Aim your original AV remote

to ZXT-800 according to above

position within 1-3cm. Press

and hold the "VOL+" button

Infrared receiving area

until blue LED flashes twice. ZXT-800 will learn the IR code

automatically. If the learning is failed or need to learn

next IR code, repeat step 2 to step 4.

Status Indicator -
-
Then Red led turns ON for indicating the IR Code Learning.
Successful: Blue LED flashes TWICE; Unsuccessful: Red LED flashes TWICE

 Continued on next page

CONTENTS

[ 13 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL

Parameter-Value (Storage Location)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Simple AV Command & IR Setting

Function Z-WaveTMAV key ID

Power

0x0027

Input

0x0026

Menu

0x001D

Smart

0x0185

Guide

0x001C

Back

0x004B

Up

0x001E

Down

0x001F

OK

0x0024

Left

0x0020

Right

0x0021

VOL+

0x0003

VOL-

0x0002

Mute

0x0001

Home

0x00AF

CH+

0x0004

CH-

0x0005

Skip-

0x011C

Stop

0x0014

Skip+

0x011B

Play

0x0013

Pause

0x0015

Rewind

0x0017

Record

0x0019

Fast Forward

0x0016

Red

0x009D

Green

0x009B

Yellow

0x009F

Blue

0x009A

 Continued on next page

CONTENTS

[ 14 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL

Parameter-Value (Storage Location)
29 30 31 32 33 34 35 36 37 38 39 40

Simple AV Command & IR Setting

Function Z-WaveTMAV key ID

0

0x0006

1

0x0007

2

0x0008

3

0x0009

4

0x000A

5

0x000B

6

0x000C

7

0x000D

8

0x000E

9

0x000F

Info

0x0011

Text

0x013F

Table 2: AV IR Learning Mapping Table (Parameter number 26)

4. Configuration Master Table
Please using the correct data format, if the Gateway support decimal numbering format, please use decimal value accordingly. If the Gateway support hexadecimal numbering format, please use hex value accordingly.
 Continued on next page

CONTENTS

[ 15 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL

Parameter Name/
Description Learn AC IR code
Learn AV IR code
Set IR code from built-in AC library
External IR Emitter power
level Set Auto Report Condition, Trigger
by Room Temperature
change
Set Built-in IR Emitter Control

Parameter Parameter Value
Number

25 (0x19) 26 (0x1A) 27 (0x1B) 28 (0x1C) 30 (0x1E)
32 (0x20)

Storage location 0 ­32 for AC IR code learning (refer to AC learning mapping table) Storage location 0 ­40 for AV IR code learning (refer to AV learning mapping table) Refer to AC code list find from code finder page by code list QR code AC Learning code number = 0000(0x0000) 0(0x00) - normal power mode 255(0xFF) - high power mode (default) 0(0x00) = Disable AUTO report function (default) It can extend the battery life.
Auto report if room temperature is different from last report 1(0x01) = 1°F (0.5°C) 2(0x02) = 2°F (1°C) 3(0x03) = 3°F (1.5°C) 4(0x04) = 4°F (2°C) 5(0x05) = 5°F (2.5°C) 6(0x06) = 6°F (3°C) 7(0x07) = 7°F (3.5°C) 8(0x08) = 8°F (4°C) It is allowed to disable internal IR emitter if use external IR emitter jack, it can extend the battery life.

Size (Byte) 1 1 2 1 1
1

0(0x00) = Disable 255(0xFF) = Enable (default)

CONTENTS

[ 16 | 24 ]

Control Air conditioner "Swing" function Temperature and Humidity Auto
Report
Calibrate temperature
reading

33 (0x21) 34 (0x22)
37 (0x25)

ZXT-800 AC/AV MASTER USER MANUAL

0(0x00) = Swing OFF

1

1(0x01) = Swing Auto (default)

Set Auto Report Condition by Time

Interval

0(0x00) = Disable AUTO report 1
(default)

1(0x01) = 15 mins

2(0x02) = 30 mins

3(0x03) = 1 Hr

4(0x04) = 2 Hrs

5(0x05) = 3 Hrs

6(0x06) = 4 Hrs

7(0x07) = 8 Hrs

Temperature offset value

0(0x00) = 0°C (default)

1(0x01) =0.5°C

2(0x02) = 1°C

3(0x03) = 1.5°C

4(0x04) = 2°C

1

5(0x05) = 2.5°C

6(0x06) =3°C

7(0x07) = 3.5°C

8(0x08) = 4°C

9(0x09) = 4.5°C

10(0x0A) = 5°C

255(0xFF) = -0.5°C

254(0xFE) = -1°C

253(0xFD) = -1.5°C

252(0xFC) = -2°C

251(0xFB) = -2.5°C

250(0xFA) = -3°C

249(0xF9) = -3.5°C

248(0xF8) = -4°C

247(0xF7) = -4.5°C

246(0xF6) = -5°C

CONTENTS

[ 17 | 24 ]

Select AV endpoint
Calibrate humidity reading

38 (0x26) 53 (0x35)

ZXT-800 AC/AV MASTER USER MANUAL
2(0x02) = end point 2 (AV1) default 1
3(0x03) = end point 3 (AV2) 4(0x04) = end point 4 (AV3)

0(0x00) = 0% (default

1

1(0x01) = 1% to 30(0x1E) = 30%

255(0xFF) = -1% to 226(0xE2) = -30%

0(0x00) = Disable BLE advertising

Trigger BLE

(default)

advertising 60 (0x3C) 255(0xFF) = Enable BLE advertising,

1

please also set Parameter 61 below.

(If the ZXT-800 is installed at ceiling

location, user can trigger BLE

advertisement through the Z-WaveTM

Configuration without click the

PROG button.)

BLE advertising 61 (0x3D) 0(0x00) = ZXT-800 advertises for 10

1

option

minutes then stop (default)

1(0x01) = ZXT-800 keep advertising,

it is suitable for USB supply power

Device reset to

160 (0xA0) 255(0xFF): device reset to default

1

default

5. Reset to Factory Default

NOTE : Please use this procedure only when the network primary controller is missing or inoperable.
· Press and Hold "PROG" button for 6 seconds on ZXT-800, the Purple indicator will light up. DO NOT release the "PROG" button until Blue indicator flashes TWICE.
· Device will be excluded from network, All Configuration Parameters will be restored to factory default. All downloaded IR data and learned data will be cleared.

CONTENTS

[ 18 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL
· ZXT-800 will send Device Reset Locally Notification to gateway. · ZXT-800 will not implement the Reset to Factory Default when the battery level
below 20%.
6. Mounting and Placement
· The ZXT-800 should be mounted on an inner wall about 5ft (1.5m) above the floor where it is readily affected by changes of the general room temperature with freely circulating air.
· Before mounting, check the material and structure of the mounting location. If the location does not have the proper material or structure, the ZXT-800 can fall and cause an injury.
· Avoid mounting above or near hot surfaces or equipment (e.g. TV, Heater, Refrigerator). Avoid mounting where it will be exposed to direct sunshine, drafts, or in a laundry room or other enclosed space.
· Better to mount your device where it has no any obstacle or blocked object between the device and your AC Appliance.

· Position ZXT-800 on wall, level and mark hole positions with pencil. · Drill holes at marked positions, then tap in supplied wall anchors. · Insert and tighten mounting screws as above figure.
 Continued on next page

CONTENTS

[ 19 | 24 ]

7. Technical Specifications

ZXT-800 AC/AV MASTER USER MANUAL

Model number
RF Frequency
RF Operating Distance Temperature Measurement
Operating Ambient Temperature
Storage Temperature Powered Source Size Weight

BW8493US (ZXT-800US) BW8493EU (ZXT-800EU) BW8493AU (ZXT-800AU) BW8493JP (ZXT-800JP) BW8493KR (ZXT-800KR) BW8493IN (ZXT-800IN) BW8493IL (ZXT-800IL) BW8493CN (ZXT-800CN) 908.4MHz (ZXT-800US) 868.4MHz (ZXT-800EU) 921.4MHz (ZXT-800AU) 922-926MHz (ZXT-800JP) 919-923MHz (ZXT-800KR) 865.2MHz (ZXT-800IN) 916.0MHz (ZXT-800IL) 868.4MHz (ZXT-800CN) Up to 500ft / 150m outdoor line of sight, in unobstructed environment
Measurable range: 0 C 40°C / 32°F 104°F Report resolution: 0.5°C / 1°F
0°C  40°C, non-condensing
-10°C  50°C USB Power DC 5V 1A or Alkaline Batteries AAA × 3pcs 90mm × 70mm × 25.5mm 70g (exclude battery)

CONTENTS

[ 20 | 24 ]

8. BLE Channels and Frequency

ZXT-800 AC/AV MASTER USER MANUAL

RF FREQUENCY MHZ
2402 2404 2406 2408 2410 2412 2414 2416 2418 2420 2422 2424 2426 2428 2430 2432 2434 2436 2438 2440 2442 2444 2446 2448 2450 2452 2454 2456 2458 2460 2462 2464

CHANNEL TYPE
Advertising channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Advertising channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel Data channel

DATA CHANNEL INDEX
0 1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

ADVERTISING CHANNEL INDEX
37
38

CONTENTS

[ 21 | 24 ]

ZXT-800 AC/AV MASTER USER MANUAL

RF FREQUENCY MHZ
2466 2468 2470 2472 2474 2476 2478 2480

CHANNEL TYPE
Data channel Data channel Data channel Data channel Data channel Data channel Data channel Advertising channel

DATA CHANNEL INDEX
30 31 32 33 34 35 36

ADVERTISING CHANNEL INDEX
39

9. Warranty
ONE-YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributors or dealer.
REMOTEC shall not be liable for: Damages caused by defective devices for indirect, incidental, special, consequential or punitive damages, including, inter alia, loss of profits, savings, data, loss of benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the device. Service trips to provide instruction on product use.
Shipping costs for replacement products.
This warranty is limited to the repair or replacement of this product only, if the purchase date cannot be substantiated, the warranty period will begin on the date of manufacture as indicated on this product. All warranty claims must be made to Remotec appointed distributors or dealers during the applicable warranty period. This warranty gives you specific legal right and you may also have other rights which vary in each country.
Website : https://www.remotec.com.hk

CONTENTS

[ 22 | 24 ]

10. Regulatory information

ZXT-800 AC/AV MASTER USER MANUAL

FCC ID : M7N-BW8493
FCC Compliance Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
· This device may not cause harmful interference, and · This device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
Notice: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.
To maintain compliance with FCC's RF Exposure guidelines, This equipment should be installed and operated with minimum 20cm distance between the radiator and your body: Use only the supplied antenna.

CONTENTS

[ 23 | 24 ]

11. IC Notice

ZXT-800 AC/AV MASTER USER MANUAL

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
· This device may not cause interference, and · This device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditionssuivantes:
· l'appareil ne doit pas produire de brouillage, et · l'utilisateur de l'appareil doit accepter tout brouillage radioélec - trique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.

12. Warnings
· Do not modify the unit in any way. · Risk of fire. · Risk of electrical shock. · Risk of burns. · Do not dispose of electrical appliances as unsorted municipal waste, use sep-
arate collection facilities. Contact your local government for information regarding the collection systems available. · There is no user serviceable parts in this unit.

13. Caution
· Risk of explosion if battery is replaced by an incorrect type. · Dispose of used batteries according to the instructions.
CONTENTS

[ 24 | 24 ]



References

LaTeX with hyperref TeX Live 2022 Debian