Hoymiles HM-800T Series Quick Installation Guide

Applicable to HM-600T/700T/800T microinverters

1. Accessories

Note: All accessories listed above are not included in the package and need to be purchased separately. Please contact our sales representative for pricing information. (M8 screws need to be prepared by the installer.)

Item Description
A AC Trunk Cable, 12/10 AWG Cable
B DC Extension Cable, 1 m
C M8 × 25 Screws
D AC Trunk Port Disconnect Tool
E AC Trunk Connector Unlock Tool
F AC Trunk Port Cap
G AC Trunk End Cap, IP67
Diagram Description: A visual representation showing items labeled A through G, corresponding to AC Trunk Cable, DC Extension Cable, M8 Screws, AC Trunk Port Disconnect Tool, AC Trunk Connector Unlock Tool, AC Trunk Port Cap, and AC Trunk End Cap, respectively.

2. Installation Steps

Ensure the microinverter is installed in the required environment. (Refer to product user manual for more details.)

2.1 Pre-installation

  1. Plan the cable length to make the bus cable aligned with each PV module.
  2. Install the AC Trunk End Cap:
    • Use the AC Trunk Connector Unlock Tool to unlock the port upper cover.
    • Loosen the three screws with a screwdriver. Untighten the cap as circled below, and remove the extra cable.
    • Screw the cap back into the port, and insert the AC Trunk End Cap.
    • Plug the upper cover back to the bus connector.
Diagram Description: A multi-step diagram illustrating the process of installing the AC Trunk End Cap. It shows using a tool to unlock a port cover, loosening screws, removing an extra cable, screwing the cap back, inserting the end cap, and plugging the cover back.

2.2 Installation Steps

Step 1. Attach Microinverter on Rail

  1. Mark the center of each panel on the frame.
  2. Fix the screw on the rail.
  3. Hang the microinverter on the screw (as shown in the picture), and tighten the screw. The silver cover side of the microinverter should be facing the panel.

Note: Please install the microinverter at least 50 cm above the ground/roof for better communication with the Hoymiles DTU.

Diagram Description: A diagram depicting the attachment of a microinverter to a mounting rail. It shows marking the panel center, fixing a screw on the rail, and then hanging the microinverter onto the screw and tightening it, with the silver cover facing the panel.

Step 2. Complete AC Connection

  1. Attach the AC Trunk Cable to the mounting rail, and secure the cable with ties.
  2. Push the AC connector of the microinverter into the trunk cable connector until you hear a clicking sound.
  3. If there is any vacant bus port, please insert the AC Trunk Port Cap in the vacant plug to ensure waterproofing and dustproofing.

Note: Under circumstances that require removing the inverter AC cable from bus port, please use the AC Trunk Port Disconnect Tool and insert the tool into the side of the AC port.

Diagram Description: A diagram showing the AC Trunk Cable being attached to a mounting rail and secured with ties. It also illustrates pushing the AC connector into the trunk cable connector until it clicks. Another part shows inserting an AC Trunk Port Cap into a vacant bus port.

Step 3. Install AC End Cable

  1. Prepare an AC end cable with proper length and insert one side of the cable into the cap. Insert the L, N and Ground lines into the appropriate slots. Tighten the screws, and then reinsert the cap tightly in the port. Plug the upper cover back to the bus connector.
  2. Connect the other side of the AC end cable to the distribution box, and wire it to the local grid network.
Diagram Description: A diagram illustrating the installation of an AC end cable. It shows preparing the cable, inserting the L, N, and Ground lines into appropriate slots in a cap, tightening screws, and reinserting the cap. The diagram also indicates that the conductor should be 'Coated with solder'. It then shows connecting the other end to a distribution box and the local grid network.

Step 4. Create an Installation Map

  1. Peel the removable serial number label from each microinverter (the position of the label is shown on the right).
  2. Affix the serial number label to the respective location on the installation map.
Diagram Description: A visual representation of an installation map with fields for panel type, azimuth, tilt, sheet information, customer information, and a grid for affixing serial number labels from microinverters. It shows a removable serial number label being peeled off.

Step 5. Connect PV Modules

  1. Mount the PV modules above the microinverter.
  2. Connect the PV modules' DC cables to the DC input side of the microinverter.
Diagram Description: A diagram showing PV modules mounted above a microinverter, with their DC cables being connected to the DC input side of the microinverter.

Step 6. Energize the System

  1. Turn on the AC breaker of the branch circuit.
  2. Turn on the main AC breaker of the house. Your system will start to generate power in about two minutes.

Step 7. Set Up the Monitoring System

Refer to the DTU User Manual, DTU Quick Installation Guide, and Quick Installation Guide for S-Miles Cloud to install the DTU and set up your monitoring system.

Product information is subject to change without notice. Please download reference manuals at www.hoymiles.com.

Region: Global AP040210 REV1.3 © 2022 Hoymiles Power Electronics Inc. All rights reserved.

Models: HM-800T, Solar Micro Inverter, Micro Inverter, Solar Inverter, HM-800T, Inverter

File Info : application/pdf, 2 Pages, 3.48MB

PDF preview unavailable. Download the PDF instead.

Quick Installation Guide HM-800T Series Global EN REV1.3

References

Adobe PDF library 16.07 Adobe Illustrator(R) 24.0

Related Documents

Preview Hoymiles HM-600/HM-700/HM-800 Single-phase Microinverter User Manual
Comprehensive user manual for Hoymiles HM-600, HM-700, and HM-800 single-phase microinverters, detailing installation, operation, safety precautions, and troubleshooting for solar photovoltaic systems. Features high efficiency and robust design.
Preview Hoymiles HM-800NT Series Quick Installation Guide for Solar Microinverters
This guide provides step-by-step instructions for the installation of Hoymiles HM-800NT Series solar microinverters, including accessory identification, pre-installation, AC and DC connections, system energization, and monitoring setup.
Preview Hoymiles HM-300/350/400 Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles HM-300, HM-350, and HM-400 single-phase microinverters, covering installation, operation, safety, troubleshooting, and technical specifications.
Preview Hoymiles Single-phase Microinverter User Manual: HM-1000, HM-1200, HM-1500
Comprehensive user manual for Hoymiles HM-1000, HM-1200, and HM-1500 single-phase microinverters, covering installation, operation, safety, troubleshooting, and technical specifications.
Preview Hoymiles Single-phase Microinverter User Manual: HM-1200, HM-1200P, HM-1500
User manual for Hoymiles HM-1200, HM-1200P, HM-1500 single-phase microinverters, covering installation, operation, safety, troubleshooting, and technical specifications for solar PV systems.
Preview Hoymiles HM-2000T-S Series Quick Installation Guide
A quick installation guide for the Hoymiles HM-2000T-S Series microinverter system, covering accessory identification, AC trunk cable planning and connection, microinverter installation, system energization, and monitoring setup.
Preview Hoymiles HM-400NT Series Microinverter Quick Installation Guide
A concise guide for installing Hoymiles HM-300NT, HM-350NT, and HM-400NT series microinverters, covering accessories, pre-installation, installation steps, AC connection, end cable installation, and system setup.
Preview Hoymiles Microinverter System Export Management Guide
A technical guide from Hoymiles detailing the installation, configuration, and operation of their Export Management System for microinverter solar power systems, ensuring grid compliance and efficient energy management.