User Manual for the t amp models including: TA-50 Power Amplifier, TA-50, Power Amplifier, Amplifier

328775

the t.amp TA-50

A5 Thomann BK margin

the t.amp TA50 – Thomann UK

User Manual


File Info : application/pdf, 20 Pages, 1.21MB

PDF preview unavailable. Download the PDF instead.

328775 c 328775 v2 en online
User Manual

TA-50
Power Amplifier

Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 Internet: www.thomann.de
05.09.2023, ID: 328775 (V2)

Table of contents

Table of contents

1 General information................................................................................................................................. 5 1.1 Symbols and signal words............................................................................................................... 5
2 Safety instructions..................................................................................................................................... 7 3 Features.......................................................................................................................................................... 9 4 Installation and starting up................................................................................................................ 10 5 Connections and controls................................................................................................................... 11 6 Technical specifications....................................................................................................................... 13 7 Plug and connection assignment.................................................................................................... 15 8 Cleaning....................................................................................................................................................... 17 9 Protecting the environment.............................................................................................................. 18

3 TA-50
Power Amplifier

4 TA-50 Power Amplifier

General information
1 General information
This document contains important instructions for the safe operation of the product. Read and follow the safety instructions and all other instructions. Keep the document for future refer- ence. Make sure that it is available to all those using the product. If you sell the product to another user, be sure that they also receive this document. Our products and documentation are subject to a process of continuous development. They are therefore subject to change. Please refer to the latest version of the documentation, which is ready for download under www.thomann.de.
1.1 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are used in this document.
5 TA-50
Power Amplifier

General information

Signal word DANGER! WARNING! NOTICE!
Warning signs

Meaning
This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a pos- sible dangerous situation that can result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a pos- sible dangerous situation that can result in material and environmental damage if it is not avoided.
Type of danger
Warning ­ danger zone.

6 TA-50 Power Amplifier

Safety instructions

2 Safety instructions

Intended use

This device amplifies electric audio frequency signals to operate passive speakers. Use the device only as described in this user manual. Any other use or use under other operating con- ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.

Safety

DANGER!
Risk of injury and choking hazard for children!
Children can suffocate on packaging material and small parts. Children can injure themselves when handling the device. Never allow children to play with the packaging material and the device. Always store packaging material out of the reach of babies and small children. Always dispose of packaging material properly when it is not in use. Never allow children to use the device without supervi- sion. Keep small parts away from children and make sure that the device does not shed any small parts (such knobs) that children could play with.
WARNING!
Possible hearing damage due to operating the device at a high volume!
The device can produce volume levels that, when operated at a high volume, may cause temporary or permanent hearing impair- ment. Over an extended period of time, even levels that seem to be uncritical can cause hearing damage. Avoid operating the device at excessively high volumes over an extended period of time. Decrease the volume level immediately if you experience ringing in your ears or hearing impairment. If this is not possible, keep a greater distance or use adequate ear-muffs.

7 TA-50
Power Amplifier

Safety instructions
NOTICE! Damage to the device if operated in unsuitable ambient conditions! The device can be damaged if it is operated in unsuitable ambient conditions. Only operate the device indoors within the ambient conditions specified in the "Technical specifications" chapter of this user manual. Avoid operating it in environments with direct sun- light, heavy dirt and strong vibrations. Avoid operating it in environments with strong temperature fluctuations. If temperature fluc- tuations cannot be avoided (for example after transport in low outside temperatures), do not switch on the device immediately. Never subject the device to liquids or moisture. Never move the device to another location while it is in operation. In environments with increased dirt levels (for example due to dust, smoke, nicotine or mist): Have the device cleaned by qualified specialists at reg- ular intervals to prevent damage due to overheating and other malfunctions.
NOTICE! Interference with nearby electrical devices due to magnetic fields! The device generates strong magnetic fields that can interfere with the function of poorly shielded devices. The magnetic fields are strongest directly above and below the Power Amplifier. You should therefore never place sensitive devices such as pre-amplifiers, radio transmission systems, or tape decks directly above or below the Power Amplifier. When placing the Power Amplifier in a rack, you should place it at the bottom thereof, and place any other equipment at the top of the rack.
NOTICE! Damage to the external power supply due to high voltages! The device is powered by an external power supply. The external power supply can be damaged if it is operated with the incorrect voltage or if high voltage peaks occur. In the worst case, excess voltages can also cause a risk of injury and fires. Make sure that the voltage specification on the external power supply matches the local power grid before plugging in the power supply. Only operate the external power supply from professionally installed mains sockets that are protected by a residual current circuit breaker (FI). As a precaution, disconnect the power supply from the power grid when storms are approaching or it the device will not be used for a longer period.
8 TA-50 Power Amplifier

3 Features

n Minimal space requirement n Ideal for mounting on flat panel displays, in suspended ceilings,... n Output power: 2 × 17 W @ 4  (2 × 20 W max.) n Integrated limiter n Suitable DC 24 V power supply included n Standby feature

Features

9 TA-50
Power Amplifier

Installation and starting up
4 Installation and starting up
Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the product against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards.
The device is suited for mounting on flat panel displays, in suspended ceilings etc. Two suit- able mounting brackets are included.

10

TA-50 Power Amplifier

5 Connections and controls

Connections and controls

STEREO

BRIDGE LIMITER
OFF ON

.. . .. .. .. ..
0 10
VOLUME

POWER

POWER

OFF

ON

AUTO

ö #$

%&

DC 24V IN

INPUT

SPEAKER OUTPUT

R

L

'

(

)

TA-50 Power Amplifier

11

Connections and controls
1 [STEREO | BRIDGE] | Switch for the "STEREO" (channels operate independently of each other) and "BRIDGED" (channels are interconnected to form one channel with double output) operating modes.
2 [LIMITER OFF | ON] | On/off switch for the integrated limiter. 3 [VOLUME] | Volume control. 4 [POWER] | Power indicator. The power indicator lights up green in normal mode and red in standby mode. 5 [POWER OFF | AUTO | ON] | OFF switch position: Device is switched off. AUTO switch position: Device is switched on.
The device automatically switches to standby mode when no input signal is received for 15 minutes. ON switch posi- tion: Device is switched on, standby function is disabled. 6 [DC 24V IN] | Phoenix terminals to connect the supplied 24 V power adapter for power supply. 7 [INPUT] | Input socket (3.5 mm jack) for connecting the signal source. 8 [SPEAKER OUTPUT] | Phoenix terminals to connect speakers in bridged (one speaker with 8 ) or stereo mode (two speakers, each with 4 ), see wiring diagram on the unit.

12

TA-50 Power Amplifier

6 Technical specifications
Amplifier class Input impedance Output power Frequency response Signal-to-noise ratio Total harmonic distortion (THD) Damping factor (1 kHz, 8 ) Sensitivity Gain Attack Protection circuitry Control indicator Power consumption Power adapter

Technical specifications

D 10 k 2 x 20 W @ 4  35 Hz...50 kHz, -3 dB -95 dB (4 , 1 K) 6.5% >20 dBu 330 mV (17 W, 4 ) 0...10 dBu 2800 ms Limiter Power max. 36 W Secondary current Secondary voltage

1500 mA 24 V

TA-50 Power Amplifier

13

Technical specifications
Dimensions (W × H × D) Weight Ambient conditions

145 mm × 95 mm × 45 mm

0.6 kg

Temperature range

0 °C...40 °C

Relative humidity

20%...80% (non-condensing)

14

TA-50 Power Amplifier

Plug and connection assignment

7 Plug and connection assignment

Introduction

This chapter will help you select the right cables and plugs to connect your valuable equip- ment in such a way that a perfect sound experience is ensured.
Please note these advices, because especially in `Sound & Light' caution is indicated: Even if a plug fits into the socket, an incorrect connection may result in a destroyed power amp, a short circuit or `just' in poor transmission quality!

Balanced and unbalanced trans- mission

Unbalanced transmission is mainly used in semi-professional environment and in hifi use. Instrument cables with two conductors (one core plus shielding) are typical representatives of the unbalanced transmission. One conductor is ground and shielding while the signal is trans- mitted through the core.
Unbalanced transmission is susceptible to electromagnetic interference, especially at low levels, such as microphone signals and when using long cables.
In a professional environment, therefore, the balanced transmission is preferred, because this enables an undisturbed transmission of signals over long distances. In addition to the conduc- tors `Ground' and `Signal', in a balanced transmission a second core is added. This also transfers the signal, but phase-shifted by 180°.
Since the interference affects both cores equally, by subtracting the phase-shifted signals, the interfering signal is completely neutralized. The result is a pure signal without any noise inter- ference.

TA-50 Power Amplifier

15

Plug and connection assignment
1/4" TS phone plug (mono, unbalanced)
1 2
3.5 mm TRS phone plug (mono, balanced)
1 2 3
Three-pole 1/8" mini phone jack (stereo, unbalanced)
1 2 3

Signal Ground
Signal (in phase, +) Signal (out of phase, ­) Ground
Signal (left) Signal (right) Ground, shielding

16

TA-50 Power Amplifier

8 Cleaning
Fan grids

Cleaning
The fan grids of the device must be cleaned of any contamination, such as dust, etc. on a reg- ular basis. Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth.

TA-50 Power Amplifier

17

Protecting the environment

9 Protecting the environment

Disposal of the packaging mate- rial

For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of.
Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging.

Disposal of your old device

This product is subject to the European Waste Electrical and Electronic Equipment Directive (WEEE) in its currently valid version. Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility.

18

TA-50 Power Amplifier

Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de



References

AH XSL Formatter V6.6 MR6 for Windows (x64) : 6.6.8.39286 (2019-06-17T09:37 09) Antenna House PDF Output Library 6.6.1465 (Windows (x64))