Candy Pura Mono Air Conditioner Series
This document provides detailed technical specifications for the Candy Pura Mono air conditioning series, available in 9000, 12000, 18000, and 24000 BTU/h capacities. The series utilizes R32 refrigerant and offers high energy efficiency ratings (A++/A+).
Product Overview
The Pura Mono series is designed for efficient cooling and heating, with models offering various performance metrics such as nominal capacity, energy efficiency ratios (SEER/EER, SCOP/COP), and power consumption.
Model | Capacity (BTU/h) | Energy Rating (Cooling/Heating) | Refrigerant |
---|---|---|---|
Pura Mono 9000 | 9000 | A++/A+ | R32 |
Pura Mono 12000 | 12000 | A++/A+ | R32 |
Pura Mono 18000 | 18000 | A++/A+ | R32 |
Pura Mono 24000 | 24000 | A++/A+ | R32 |
Cooling Performance
Detailed cooling performance data, including nominal capacity, SEER/EER values, and energy consumption, are provided for each model. Operating limits for cooling are also specified.
Model | Nominal Capacity (BTU/h) | Nominal Capacity (kW) | SEER/EER | Pdesign RAFF (kW) | Annual Energy Consumption RAFF (kWh/a) | Operating Limits RAFF (°C) |
---|---|---|---|---|---|---|
Pura Mono 9000 | 9215 (2390-11600) | 2.7 (0.7-3.4) | 6.5/3.23 | 2.7 | 145 | -20~43° (out) |
Pura Mono 12000 | 10920 (2730-12965) | 3.2 (0.8-3.8) | 6.1/3.23 | 3.2 | 184 | -20~43° (out) |
Pura Mono 18000 | 15015 (4430-18420) | 4.4 (1.30-5.40) | 6.3/3.23 | 4.8 | 267 | -20~43° (out) |
Pura Mono 24000 | 20475 (4430-25250) | 6.0 (1.30-7.40) | 6.7/3.23 | 6.2 | 324 | -20~43° (out) |
Heating Performance
Heating performance data, including nominal capacity, SCOP/COP values, and annual energy consumption for heating, are presented. Operating limits for heating are also detailed.
Model | Nominal Capacity (BTU/h) | Nominal Capacity (kW) | SCOP/COP | Pdesign RISC (kW) | Annual Energy Consumption RISC (kWh/a) | Operating Limits RISC (°C) |
---|---|---|---|---|---|---|
Pura Mono 9000 | 9895 (2390-12285) | 2.9 (0.7-3.6) | 4.0/3.71 | 2.6 | 910 | -20~24° (out) |
Pura Mono 12000 | 11945 (2390-13650) | 3.5 (0.7-4.0) | 4.0/3.71 | 3.0 | 1050 | -20~24° (out) |
Pura Mono 18000 | 15695 (4430-18420) | 4.6 (1.3-5.4) | 4.0/3.71 | 3.6 | 1260 | -20~24° (out) |
Pura Mono 24000 | 21500 (4770-25590) | 6.3 (1.4-7.5) | 4.0/3.71 | 4.6 | 1610 | -20~24° (out) |
Unit Dimensions and Weight
Physical dimensions and weight for both indoor and outdoor units are provided.
Model | Net Dimensions (W/D/H) (mm) | Packaging Dimensions (W/D/H) (mm) | Net Weight (kg) | Max Airflow (m³/h) |
---|---|---|---|---|
Pura Mono 9000 | 805/292/200 | 876/365/272 | 8.8 | 550 |
Pura Mono 12000 | 805/292/200 | 876/365/272 | 8.8 | 650 |
Pura Mono 18000 | 875/212/304 | 945/390/296 | 10.0 | 770 |
Pura Mono 24000 | 975/222/318 | 1050/397/301 | 11.6 | 1100 |
Model | Net Dimensions (W/D/H) (mm) | Packaging Dimensions (W/D/H) (mm) | Net Weight (kg) | Max Airflow (m³/h) |
---|---|---|---|---|
Pura Mono 9000 | 700/245/544 | 819/320/592 | 21.5 | 2100 |
Pura Mono 12000 | 700/245/544 | 819/320/592 | 22.0 | 2100 |
Pura Mono 18000 | 800/280/553 | 902/375/614 | 29.2 | 2200 |
Pura Mono 24000 | 800/280/553 | 902/375/614 | 32.7 | 2500 |
Sound Pressure and Power Levels
Sound levels for both indoor and outdoor units during cooling and heating operations are specified.
Unit | Operation | Sound Power | Sound Pressure (H/M/L) |
---|---|---|---|
Indoor Unit | Cooling | 57-64 | 20-44 |
Heating | 57-64 | 20-44 | |
Outdoor Unit | Cooling | 62-68 | 50-57 |
Heating | 62-68 | 51-57 |
Dehumidification
The dehumidification capacity of the units is provided.
Model | Capacity (L/h) |
---|---|
Pura Mono 9000 | 1.2 |
Pura Mono 12000 | 1.4 |
Pura Mono 18000 | 2.0 |
Pura Mono 24000 | 2.8 |
Outdoor Unit Details
Information regarding the outdoor unit's compressor, refrigerant type, and piping specifications.
Feature | Pura Mono 9000 | Pura Mono 12000 | Pura Mono 18000 | Pura Mono 24000 |
---|---|---|---|---|
Compressor Brand | RECHI | HIGHLY | SANYO | HIGHLY |
Compressor Type | Inverter Single Rotary | Inverter Single Rotary | Inverter Single Rotary | Inverter Twin Rotary |
Refrigerant Type | R32 | R32 | R32 | R32 |
Refrigerant Charge (kg) | 0.510 | 0.510 | 0.780 | 0.900 |
Liquid Pipe Diameter (mm) | 6.35 | 6.35 | 6.35 | 6.35 |
Gas Pipe Diameter (mm) | 9.52 | 9.52 | 12.7 | 12.7 |
Max Pipe Length (m) | 20/10 | 20/10 | 20/15 | 25/15 |
Max Height Difference (m) | 5 | 5 | 7 | 7 |
Additional Charge (g/m) | 20 | 20 | 20 | 20 |
Manufacturer Information
Details about the manufacturer and distributor.
Manufacturer: HAIER AIR CONDITIONING, N.1 Haier Road, Qingdao - 266101 PR China
Distributor: Haier A/C (Italy) Trading S.p.a. Unipersonale, Via Marconi, 96-31020 Revine Lago TV-Italy
Website: haiercondizionatori.it
Notes
Performance data is based on tests conducted in accordance with UNI EN 14511.
Reference conditions for Heating: Ambient temperature: 20°C BS; Outdoor temperature: 7°C BS.
Reference conditions for Cooling: Ambient temperature: 27°C BS-19.5°C BU; Outdoor temperature: 35°C BS.
Data in this document may be subject to change. Buyers should verify accuracy with the supplier before signing any order or purchase agreement.