User Guide for Carrier models including: TV-UCXPIO48, TV-UCXPIO48 TruVu I O Expanders, TV-UCXPIO48, TruVu I O Expanders, I O Expanders
TruVu™ I/O Expander
File Info : application/pdf, 32 Pages, 912.34KB
DocumentDocumentTruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide ©2024 Carrier. All rights reserved. · Catalog No. 11-808-1009-01 · 9/11/2024 Verify that you have the most current version of this document from www.hvacpartners.com, the Carrier Partner Community website, or your local Carrier office. Important changes are listed in Document revision history at the end of this document. ©2024 Carrier. All rights reserved. Contents What are TruVuTM I/O Expanders? .............................................................................................................................. 1 Specifications ........................................................................................................................................................2 TV-UCXPIO48 Expander power and communication configurations ....................................................................... 4 Wiring the TV-UCXPIO48 to the controller's I/O Bus ................................................................................................. 5 To mount the expander........................................................................................................................................5 To wire an external power supply to the expander..........................................................................................6 To wire the expander for communications .......................................................................................................8 To address the TV-UCXPIO48...................................................................................................................................... 9 Wiring inputs and outputs.........................................................................................................................................10 Inputs ................................................................................................................................................................... 10 Outputs ................................................................................................................................................................ 11 Wiring specifications ......................................................................................................................................... 12 To wire inputs and outputs ............................................................................................................................... 12 To adjust input and output properties .....................................................................................................................15 Input values ........................................................................................................................................................ 15 Output values ..................................................................................................................................................... 17 Resolution values .............................................................................................................................................. 17 Offset/Polarity values ....................................................................................................................................... 18 To use an output's Hand-Auto-Off switch ....................................................................................................... 19 Troubleshooting .........................................................................................................................................................20 LED's .................................................................................................................................................................... 20 Troubleshooting inputs and outputs ............................................................................................................... 20 To get the TV-UCXPIO48's serial number ....................................................................................................... 22 To monitor expander communication ............................................................................................................ 22 To replace the TV-UCXPIO48's fuses............................................................................................................... 23 Compliance ................................................................................................................................................................25 FCC Compliance ................................................................................................................................................. 25 CE and UKCA Compliance ................................................................................................................................ 25 Industry Canada Compliance........................................................................................................................... 25 Document revision history ........................................................................................................................................26 What are TruVuTM I/O Expanders? TruVu I/O Expanders (part no. TV-UCXPIO Expanders) connect to TruVu Advanced Equipment Controllers to provide inputs and outputs. You can connect a single TV-UCXPIO Expanders to the TruVu Expandable Universal Equipment Controller 683 (part no. UCXP683T) This expander (part#)... TV-UCXPIO Expanders Provides this number of inputs... 8 And this number of outputs... 4 TV-UCXPIO Expanders TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 1 ©2024 Carrier. All rights reserved. Specifications Power I/O Bus port I/O Bus edge connector Inputs Input resolution Input pulse frequency Outputs Output resolution Microprocessor Protection Status indicators Environmental operating range Physical Terminal blocks and connectors 24 Vac ±10%, 5060 Hz, 50 VA 26 Vdc ±10%, 12 W Provides communication to TV-UCXP683T and TV-UCXP683T-V host modules. The port's End of Net? switch can be used to terminate the expander network. Not used by the TV-UCXP I/O Expander 8 Inputs are configurable in the control program for 05 Vdc, 010 Vdc, 020 mA, RTD, thermistor, dry contact, or pulse counter. 16 bit A/D 40 pulses per second. Minimum pulse width (on or off time) required for each pulse is 12.5 msec. 4 Outputs can be set as analog or binary outputs. Analog outputs can be used for 0-10 Vdc or 0-20 mA devices. Binary outputs have a built-in relay and can be used to switch external devices or relays up to 1A, 30 Vac/Vdc. 12 bit D/A 32-bit microprocessor with 256 kB Flash memory and 64 kB SRAM The TV-UCXPIO48 has two fast acting , 5 mm x 20 mm glass fuses: · A 2A fuse for the TV-UCXPIO48's power · A 4A fuse which is not used by this expander The power and network ports comply with the EMC requirements EN50491-5-2. LEDs indicate status of communications, system state (running or errors), outputs, and power -40 to 158°F (-40 to 70°C), 10-95% relative humidity, non-condensing NOTES · The TV-UCXPIO48 is suitable for installation inside or outside the building envelope. · Install in a UL Listed enclosure only. · Do not change the position of the power or End of Net switch at temperatures below -22°F (-30C) to ensure proper operation and electrical connectivity. Fire-retardant plastic ABS, UL94-5VA Screw-type terminal blocks. 0.2 in (5.08 mm) pitch connectors TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 2 ©2024 Carrier. All rights reserved. Overall dimensions A: B: Depth: Screw mounting dimensions C: D: 6.9 in. (17.53 cm) 6.95 in. (17.65 cm) 2.09 in. (5.31 cm) 6.45 in (16.38 cm) 4.1 in. (10.4 cm) Weight Compliance 1.1 lb. (0.49 kg) United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class A; UL Listed to UL 916, PAZX, Energy Management Equipment Canada: Industry Canada Compliant, ICES-003, Class A cUL Listed UL 916, PAZX7, Energy Management Equipment Europe: Mark, UK: EN50491-5-2:2009; Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment RoHS Compliant: 2015/863/EU REACH Compliant Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3 TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 3 ©2024 Carrier. All rights reserved. TV-UCXPIO48 Expander power and communication configurations Wire to the I/O Bus port for communication and then wire to an external transformer for power See Wiring the TV-UCXPIO48 to the controller's I/O bus (page 5). WARNING Do not apply line voltage (mains voltage) to the controller's ports and terminals. CAUTIONS · The TV-UCXPIO48 is powered by a Class 2 power source. Take appropriate isolation measures when mounting it in a control panel where non-Class 2 circuits are present. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 4 ©2024 Carrier. All rights reserved. Wiring the TV-UCXPIO48 to the controller's I/O Bus When wiring the TV-UCXPIO48 to the controller, you must: 1 Mount the expander (page 5) 2 Wire an external power supply to the expander 3 Wire the expander for communication with the controller To mount the expander NOTE We recommend screw mounting when installing in a high temperature and high humidity environment. DIN rail mount 1 Push down and pull out the center tabs shown below to clear the DIN rail trough on the back of the expander. 2 Place the expander on the DIN rail so that the rail is in the trough on the back of the expander. 3 Push the center tabs towards the expander until you hear them click. 4 Pull gently on the expander to verify that it is locked in place. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 5 ©2024 Carrier. All rights reserved. Screw Mount Leave about 2 in. (5 cm) on each side of the controller for wiring. Insert #6 screws through the mounting tabs. Use no more than 8 in.lbs. torque to secure plastic tab to mounting surface. A: B: C: D: Depth: 6.9 in. (17.53 cm) 6.95 in. (17.65 cm) 6.45 in. (16.38 cm) 4.1 in. (10.4 cm) 2.24 in (5.69 cm) To wire an external power supply to the expander WARNING Do not apply line voltage (mains voltage) to the controller's ports and terminals. CAUTIONS · The TV-UCXPIO48 is powered by a Class 2 power source. Take appropriate isolation measures when mounting it in a control panel where non-Class 2 circuits are present. · Carrier controllers can share a power supply as long as you: · Maintain the same polarity. · Use the power supply only for Carrier controllers. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 6 ©2024 Carrier. All rights reserved. To wire the power supply to the expander 1 Make sure the TV-UCXPIO48's power switch is in the OFF (down) position to prevent it from powering up before you can verify the correct voltage. 2 Remove power from the power supply. 3 Pull the red screw terminal connector from the expander's power terminals labeled 24 V (+/-). 4 Connect the power supply's wires to the red screw terminal connector. 5 Connect an 18 AWG or larger wire from the power supply's negative (-) terminal to earth ground. This wire must not exceed 12 in. (30.5 cm). 6 Apply power to the power supply. 7 Measure the voltage at the red screw terminal connector to verify that the voltage is within the operating range of 20 to 30 Vac or 23.4 to 30 Vdc. 8 Insert the red screw terminal connector into the expander's power terminals. 9 To verify the polarity of the wiring, measure the voltage from the negative terminal of the red screw terminal connector to a nearby ground. The reading should be 0V. 10 Turn on the TV-UCXPIO48's power switch. 11 Verify that the PWR LED on top of the expander is on. 12 Measure the voltage at the red screw terminal connector to verify that the voltage is within the operating range of 20 to 30 Vac or 23.4 to 30 Vdc. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 7 ©2024 Carrier. All rights reserved. To wire the expander for communications Wiring restrictions for connecting the expander to the controller Maximum length: 100 feet (30 meters) 22 or 24 AWG, low-capacitance, twisted, stranded, shielded copper wire WARNING Do not apply line voltage (mains voltage) to the expander's ports and terminals. 1 Turn off the controller's and expander's power. 2 Wire the expander's I/O Bus port to the same port on the controller. NOTE Use the same polarity throughout the network segment. 3 Set the I/O Bus End of Net? switch to Yes to apply network termination and bias. NOTE The controller has built-in I/O bus network termination. 4 Turn on the controller's and expander's power. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 8 ©2024 Carrier. All rights reserved. To address the TV-UCXPIO48 1 Turn off the power switch on the controller that the TV-UCXPIO48 is attached to. 2 Set the TV-UCXPIO48's address on the rotary switch to 1 as shown below. 3 Turn on the controller's power switch. The controller reads the TV-UCXPIO48's address each time you turn on the controller's power. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 9 ©2024 Carrier. All rights reserved. Wiring inputs and outputs Inputs The TV-UCXPIO48 has inputs that accept the following signal types. Signal Type Thermistor 1 Dry contact 05 Vdc 010 Vdc 020 mA Description · Precon Type 2 (10kOhm at 77 °F) · Carrier YSI 5kOhm at 77 °F · TS-5700-850 10kOhm w/ 11kOhm shunt (5238 ohm@77°F) Input voltages should be from 0.09 Vdc to 4.36 Vdc for thermistors. The maximum current when the contact is closed is 0.5 mA. The input voltage should be 4.5V when the contact is open. Maximum closed contact resistance is 1kOhms. The input impedance of the TV-UCXPIO48 is approximately 221 kOhm when configured as a voltage input. The input resistance on the positive (+) terminal is 200 Ohms when configured as a current input. Each 24 Vdc connector is capable of supplying 24 Vdc to multiple 420 mA transducers. RTD 1 CAUTION Both connectors combined must not exceed: 66.7 mA for the and 100 mA for the and · Platinum 1kOhm at 32°F (0°C) (0.00375 TCR) · Nickel-iron 1kOhm at 70°F (21°C) · Platinum TS-8000 1kOhm at 32°F (0°C) (0.00385 TCR) · Balco (nickel-iron) TS8000 1kOhm at 70°F (21°C) Input voltages should be from 0.30.68V. NOTE Carrier recommends use of an external current transducer between an RTD and the TV-UCXPIO48 to improve accuracy and resolution. Pulse counter 2 Pulse counting up to pulses per second. Minimum pulse width (on or off time) required for each pulse is msec. 1 To use a thermistor or RTD not listed above, you can set up a custom translation table for your sensor in the controller's driver. 2 The TV-UCXPIO48 can perform pulse counting for dry contact or voltage inputs if you assign the input to a Pulse to Analog Input microblock. See To adjust input and output properties. WARNING Do not apply voltage to any input configured for 0-20 mA as this could damage the expander. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 10 ©2024 Carrier. All rights reserved. Outputs The TV-UCXPIO48's universal outputs can be set as analog or binary on their two DIP switches. The expanders' outputs return to their unconfigured state if they are removed from the program or the program is deleted from the controller. Also, outputs time out and return to their unconfigured or off state after two minutes of inactivity. The unconfigured state results in: · Not running control programs that are due to download · Losing power to the controller, but not the expander NOTE This does not apply to outputs that have been locked in the i-Vu® application. Analog outputs Outputs set up as analog can be used for: · 0-10 Vdc devices · 0-20 mA devices WARNING Do not apply voltage to any output whose DIP switch is set to Analog. If output controls a... 010 Vdc device 020 mA device Resistance to ground must be... 500 Ohms minimum 500 Ohms maximum NOTE The device must share the same ground as the expander. Binary outputs The outputs have a built-in relay and provide a dry contact so an external voltage source must be wired to one of the two terminals. Outputs set up as binary can be used to switch external devices and relays up to 1A, 30 Vac/Vdc. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 11 ©2024 Carrier. All rights reserved. Wiring specifications Input wiring Input Thermistor Dry contact 05 Vdc 010 Vdc 020 mA RTD Maximum length 1000 feet (305 meters) 1000 feet (305 meters) 3000 feet (914 meters) 100 feet (30 meters) Minimum gauge 22 AWG 26 AWG 26 AWG 22 AWG Shielding Shielded Shielded Shielded or unshielded Shielded NOTES · Carrier recommends use of an external current transducer between an RTD and the TV-UCXPIO48 to improve accuracy and resolution. · RTD inputs require either sensor calibration or an estimated offset correction for wiring resistance. See Offset and Polarity values (page 18). Output wiring To size output wiring, consider the following: · Total loop distance from the controller to the controlled device NOTE Include the total distance of actual wire. For 2-conductor wires, this is twice the cable length. · Acceptable voltage drop in the wire from the controller to the controlled device · Resistance (Ohms) of the chosen wire gauge · Maximum current (Amps) the controlled device requires to operate To wire inputs and outputs WARNING Do not apply line voltage (mains voltage) to the controller's ports and terminals. 1 Verify that the TV-UCXPIO48's power and communications connections work properly. 2 Turn off the TV-UCXPIO48's power. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 12 ©2024 Carrier. All rights reserved. 3 Connect the input wiring to the UI screw terminals on the TV-UCXPIO48. WARNING Do not apply voltage to any input configured for 0-20 mA as this could damage the expander. NOTE Connect the shield wire to the terminal with the ground wire. Do not connect the shield wire at the other end of the cable as this will cause a ground loop error. 10 kOhm thermistor Dry contact 1 kOhm RTD + Any input - + Any input - + Any input - 2 wire 3 wire External 24 Vdc half-wave power supply 4 wir e V+ 0-5 Vdc, 0-10 Vdc, Out or 4-20 mA V+ 0-5 Vdc, 0-10 Vdc, Out or Gnd 4-20 mA + Any input n/c - + Any input - V+ 0-5 Vdc, Out + 0-10 Vdc, Gnd or 4-20 mA Out - + Any input - 2 wire 3 wire 0-5 Vdc, V+ 0-10 Vdc, Out or 4-20 mA V+ 0-5 Vdc, Out 0-10 Vdc, or Gnd 4-20 mA + Any input n/c - + Any input - 4 wir e V+ 0-5 Vdc, Out + 0-10 Vdc, Gnd or Out 4-20 mA + Any input - 24 Vdc connector NOTE For a loop-powered 4-20 mA sensor, wire the sensor's positive terminal to the + terminal on the TV-UCXPIO48's 24 Vdc connector. Wire the sensor's negative terminal to an input's + terminal. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 13 ©2024 Carrier. All rights reserved. 4 Connect binary and analog output wiring to the UO screw terminals on the TV-UCXPIO48 and to the controlled device. Connect the ground wire to the UO's terminal. WARNING Do not apply voltage to any output whose DIP switch is set to Analog. Analog outputs Binary outputs - Any UO + - Any UO + - Any UO + - Any UO + - Any UO + 0-1 0 V + 2-wire Gnd 0-1 0 V + Hot 3-wire Hot 0-1 0 V + Gnd 4-wire 0-20 mA + Hot 3-wire Hot 0-20 mA + Gnd 4-wire 24 Vac/Vdc - Any UO + Gnd Coil: 24 Vac/Vdc, 1 A max. 24 Vac/Vdc - Any UO + To external device 24 Vac/Vdc, 1A max. 24 Vac/Vdc 5 Set each output's two DIP switches to the appropriate settings for the type of device wired to the output. For... Analog 0-20 mA Analog 0-10 Vdc Binary Set top DIP switch to... Up Up Down Set bottom DIP switch to... Up Down N/A CAUTION Outputs are set to Binary in the factory. To avoid damage to the expander, use a voltmeter to verify there is no voltage on the + and terminals before setting the DIP switch to Analog. 6 Turn on the TV-UCXPIO48's power. See Troubleshooting inputs and outputs. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 14 ©2024 Carrier. All rights reserved. To adjust input and output properties An input or output must be assigned to its corresponding point in the control program. This is typically done when the control program is created, but you can adjust the settings at the time of installation in the i-Vu® interface. 1 In the i-Vu® Geographic tree, select the equipment controlled by the TV-UCXPIO48. 2 On the Properties page, select the I/O Points tab. 3 For each point, type the expander's rotary switch address in the Exp field and the number of the expander's corresponding input or output in the Num field. EXAMPLE If UO-01 on the TV-UCXPIO48 (which has a rotary switch address of 1) is used for the point Fan S/S, enter 1:1 in the Exp:Num column for Fan S/S. NOTE Do not assign the same output number to more than one point. 4 Enter the appropriate values for each input and output in the remaining columns. See Input values, Output values, Resolution values and Offset/Polarity values below. CAUTION Do not assign two input microblocks to the same physical input using Dry Contact in one and Binary Input in the other. This results in faulty behavior. 5 If you have not performed the initial download to the attached controller, you must download now to verify inputs and outputs. 6 To verify each input's operation, force each sensor to a known value, then compare it to the Value shown on the Properties page on the I/O Points tab. 7 To verify each output's operation, lock each output to a known condition on the I/O Points tab, then verify that the equipment operates correctly. See Troubleshooting inputs and outputs. Input values Input Analog (BAI) 0-5 Vdc I/O Type 05 Volt 0-10 Vdc 010 Volt Sensor/Actuator Type Linear Full Range No Translation Linear Full Range No Translation Min/Max Engineering values associated with 0 Vdc (Min) and 5 Vdc (Max) 1 N/A. The input microblock's value will be the raw voltage of the input. Engineering values associated with 0 Vdc (Min) and 10 Vdc (Max) 1 N/A. The input microblock's value will be the raw voltage of the input. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 15 ©2024 Carrier. All rights reserved. Input 2-10 Vdc 0-20 mA I/O Type 010 Volt 020 mA 4-20 mA RTD 020 mA RTD Input Thermistor Thermistor Pulse to Analog (BPTA) 3 Pulse Counter Dry Contact or Binary Input Binary (BBI) Dry Contact Dry Contact Sensor/Actuator Type Min/Max Linear w/Offset, 210 Volts Engineering values associated with 2 Vdc (Min) and 10 Vdc (Max) 1 Linear Full Range Engineering values associated with 0 mA (Min) and 20 mA (Max) 1 No Translation N/A. The input microblock's value will be the raw milliamps of the input. Linear w/Offset, 420 mA Engineering values associated with 4 mA (Min) and 20 mA (Max) 1 Select your RTD type or set up N/A and select a Non-Linear, Custom Table 2, 4 Select your Thermistor type or N/A set up and select a Non-Linear, Custom Table 2 N/A N/A N/A N/A CAUTION Do not assign two input microblocks to the same physical input using Dry Contact in one and Binary Input in the other. This results in faulty behavior. 5 1 The sensor reads a value and sends a corresponding signal (Volt or mA) to the TV-UCXPIO48's physical input. The Analog Input microblock uses the Min and Max values to linearly translate the signal into the engineering value used in subsequent control logic. For example, set Min to 0 and Max to 10 for a 420 mA sensor that measures velocity from 0.0 to 10.0 inches/second so that when the input reads 4 mA, the microblock outputs a value of 0. Similarly, when the input reads 8 mA, the microblock outputs a value of 2.5. 2 You can set up a custom translation table on the driver's Custom Translation Tables pages in the i-Vu® interface. 3 The control program must have one Pulse to Analog Input microblock for each pulse counting input. 4 To improve the accuracy for RTD sensors used with long cables, see Offset/Polarity values (page 18). 5 Binary Input and Dry Contact input types are not interchangeable. Setting an input to Dry Contact applies a wetting voltage to sense a dry contact. Setting an input to Binary Input will not apply a wetting voltage. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 16 ©2024 Carrier. All rights reserved. Output values Output I/O Type Sensor/Actuator Type Min/Max Analog (BAO) 0-10 Vdc Electrical 010 Volt Linear Full Range Engineering values associated with 0 Vdc (Min) and 10 Vdc (Max) 1 No Translation N/A. The Analog Output microblock will output the same value that comes in to the microblock. 2-10 Vdc Electrical 010 Volt Linear w/Offset, 210 Volts Engineering values associated with 2 Vdc (Min) and 10 Vdc (Max) 1 0-20 mA Electrical 020 mA Linear Full Range Engineering values associated with 0 mA (Min) and 20 mA (Max) 1 No Translation N/A. The Analog Output microblock will output the same value that comes in to the microblock. 4-20 mA Electrical 020 mA Linear w/Offset, 420 mA Engineering values associated with 4 mA (Min) and 20 mA (Max) 1 Digital (Binary) (BBO) Relay Relay/Triac N/A N/A Output 1 The Analog Output microblock uses the Min and Max values to linearly translate its incoming value into a physical output signal (Volt or mA) sent from the TV-UCXPIO48 to an actuator. For example, set Min to 0 and Max to 100 for an Analog Output microblock that receives a 0 to 100% open signal from a PID microblock and that controls a 010 Vdc actuator so that when the PID signal is 100%, the TV-UCXPIO48 output is 10 Vdc. Similarly, when the PID signal is 50%, the TV-UCXPIO48 output is 5 Vdc. Resolution values Resolution is not particular to a type of input or output, but the driver handles analog and binary inputs and outputs differently. To set these values appropriately, you should understand how the driver uses them. Resolution Analog Input (BAI) Analog Output (BAO) Notes The driver rounds the microblock's present value according to the resolution. EXAMPLE If the calculated present value is 13.789 and you set the Resolution to 0.1, the control program uses 13.8 for any calculations downstream from the microblock. The driver rounds the wire input value to the microblock before performing any scaling calculations. EXAMPLE If the wire input value is 13.789 and you set the Resolution to 0.1, the microblock uses 13.8 for any scaling calculations. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 17 ©2024 Carrier. All rights reserved. Offset/Polarity values Offset/Polarity is not particular to a type of input or output, but the driver handles analog and binary inputs and outputs differently. To set these values appropriately, you should understand how the driver uses them. Offset/Polarity Analog Input (BAI) Notes Offset value (positive or negative) adds a fine adjustment to a sensor reading after all scaling for calibration. EXAMPLE If a sensor reads 74.9°F when the actual measured value is 73.6°F, enter an Offset of 1.3 to calibrate the sensor to the measured value. RTD inputs require either sensor calibration or an estimated offset correction for wiring resistance. Cable length and size affects RTD sensor accuracy. Use the following information for a 100 ft. (30.48 m) cable as a guideline for entering an offset. For shorter cable, scale the offset linearly. For example, for a 50 ft. cable, use half the offset shown below. RTD sensor Offset for 100 ft. (30.48 m) cable 22 AWG 18 AWG Platinum 1kOhm at 32°F (0°C) (0.00375 -1.5 TCR) -0.59 Nickel-iron 1kOhm at 70°F (21°C) -1.1 -0.43 Platinum TS-8000 1kOhm at -1.5 32°F (0°C) (0.00385 TCR) -0.59 Balco (nickel-iron) TS8000 1kOhm -1.4 at 70°F (21°C) -0.56 Cable resistance for signal and 3.1 ground wires (ohms) 1.24 Analog Output (BAO) You can use the Offset value (positive or negative) to calibrate an output, but you generally do not need to. If used, the driver adds the offset value to the wire input value before performing any scaling calculations to determine the TV-UCXPIO48's output. Binary Input (BBI) Polarity determines the microblock's present value when no signal is received from the equipment. When no signal is received from the equipment, if Polarity is set to: normal--present value is off reversed--present value is on Binary Output (BBO) Polarity determines the TV-UCXPIO48's output based on the control program's signal to the microblock. When the control program's signal to the microblock is on, if Polarity is set to: normal--output is on reversed--output is off NOTE Regardless of Polarity, the output will be off if the TV-UCXPIO48 loses power. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 18 ©2024 Carrier. All rights reserved. To use an output's Hand-Auto-Off switch You can control an output using the Hand-Auto-Off switch. Set the switch to... Hand Auto Off To... · Turn on a binary output. · Allow an analog output to be controlled by the AO Hand Override potentiometer. Let the control program control the output Turn off the output The AO Hand Override, located below the Hand-Auto-Off switch, allows you to manually control the output level of an analog output. Place the Hand-Auto-Off switch in the Hand position, then turn the potentiometer counterclockwise to reduce the output, or clockwise to increase the output. The control program can monitor the status of a Hand-Auto-Off switch and display the status on the control program's Properties page > I/O Points tab in the i-Vu® interface. The Value of the point monitoring the Hand-Auto-Off switch shows Off if the switch is set to Auto, and On if the switch is set to Hand or Off. To monitor the position of the manual Hand-Auto-Off switch 1 Insert a BACnet Binary Input microblock in the control program. 2 On the microblock's Properties page in the i-Vu® interface, set the I/O Type field to H-A-O Status Feedback. 3 In the Input Number field, type the number of the output you want to monitor. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 19 ©2024 Carrier. All rights reserved. Troubleshooting LED's The LED's on the TV-UCXPIO48 show the status of certain functions. If this LED is on... Pwr RX TX Sts Status Status is... The TV-UCXPIO48 has power. The TV-UCXPIO48 is receiving data from the I/O bus. The TV-UCXPIO48 is transmitting data over the I/O bus. Green, slow blink: Expander is functioning normally. Red, fast blink: The controller cannot update the expander's firmware. In the i-Vu® application, go to the controller driver I/O Bus and Xnet Expanders page to see if the expander is communicating with the controller. Green, fast blink: Red, continuously on: Firmware download is in progress. Invalid configuration settings. Contact Technical Support. Located just below each output's AO Hand Override potentiometer, the LED flashes when the expander starts up. After startup, if the output is: · Binary, the LED will be either on or off to indicate the output's status. · Analog, the LED's brightness indicates the strength of the output signal. Troubleshooting inputs and outputs The i-Vu® interface shows if you have I/O errors resulting from: · A misconfigured microblock · A misconfiguration on the expander · A missing or disconnected expander To check for errors: 1 In the i-Vu® User tab or Network tree, select the equipment controlled by the . 2 On the Properties page, select the I/O Points tab. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 20 ©2024 Carrier. All rights reserved. 3 Click the Name of any input or output whose name is red (indicates an error) to open its dialog box. 4 On the Details tab, scroll down to see the Reliability field under BACnet Configuration. 5 Anything other than No Fault Detected indicates an error. See the table below to determine the error and possible actions to take. Reliability description Communication Failure Configuration Error Over Range No Output No Sensor Shorted Loop Possible error · Expander is not connected to the controller. · The expander has no power. · The controller is offline. · The microblock's I/O Type and Sensor/Actuator Type are not compatible. · The output's DIP switch setting does not match the connected device. · Invalid expander address or I/O number. · Input exceeds the Min/Max limits. · Output's Hand-Auto-Off switch is in Hand or Off position. · No device is attached to the output. · Internal voltage feedback does not correspond with commanded value. Verify that... · The expander is connected to the controller's I/O bus port. · The expander has power. · The I/O Type and Sensor/Actuator Type combination is valid for the I/O number and microblock type. · The DIP switch setting is appropriate for the output and microblock type. · The expander is present and functional at the address shown in the i-Vu® interface and that I/O number is valid. · The input is within the Min/Max limits. · The expander's Hand-Auto-Off switch is in the Auto position. · The device is present and functioning. · The load on the output is within the valid range. · A voltage/current source has not been connected to an output. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 21 ©2024 Carrier. All rights reserved. Reliability description Open Loop Unreliable Other Possible error Verify that... · Internal current feedback does not · The load on the output is within the valid correspond with commanded value. range. · A voltage/current source has not been connected to an output. · Feedback from the expander does not · Expander may be faulty. Contact correspond with commanded value (for Technical Support. example, the output relay is not in commanded state). To get the TV-UCXPIO48's serial number If you need the TV-UCXPIO48's serial number when troubleshooting, the number is laser-etched on the board inside the TV-UCXPIO48. To remove the cover, insert a small flathead screwdriver as shown below, and then gently pry up on the cover until it is released from the base. To monitor expander communication You can add an analog input in a control program that will provide the communication status of the TV-UCXPIO48. If the input reads a value of , the expander is communicating. If the input reads 0, the expander is not communicating. To have the input provide the TV-UCXPIO48's status, define the following properties for the input. Expander: The expander number you want to read Input Number: 1 Input Type: Special TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 22 ©2024 Carrier. All rights reserved. To replace the TV-UCXPIO48's fuses The TV-UCXPIO48 has 2 fuses: Symptoms of a blown fuse: Expander's power fuse - The expander's Pwr LED is not lit. If you suspect a fuse is blown, remove the fuse as described below, and use a multimeter to check it. If the fuse is blown, try to determine why it blew before you replace it. Check the power wiring polarity of the TV-UCXPIO48 and any other devices that share the power supply. Use the same polarity for all of them. The fuses are fast-acting, 5mm x 20mm glass fuses that you can purchase from one of the following vendors: Manufacturer Littelfuse Bussmann Belfuse Optifuse Mfr. Part # for 2A fuse 0217002.HXP S500-2-R 5SF 2-R FSD-2A Mfr. Part # for 4A fuse 0217004.HXP S500-4-R 5SF 4-R FSD-4A TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 23 ©2024 Carrier. All rights reserved. To replace a fuse: 1 Turn off the TV-UCXPIO48's power switch. 2 On one end of the expander, insert a small flathead screwdriver as shown below, and then gently pry up on the cover until it is released from the base. 3 Remove the cover from the base. 4 Use a fuse puller to remove the blown fuse. 5 Use the fuse puller to snap the new fuse into the fuse holder. 6 Replace the expander's cover. 7 Depending on how you removed power in step 2, replace the expander's power connector. 8 Turn on the TV-UCXPIO48's power switch. 9 Verify the Pwr LEDs on. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 24 ©2024 Carrier. All rights reserved. Compliance FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 This device may not cause harmful interference. 2 This device must accept any interference received, including interference that may cause undesired operation. NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with this document, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. CAUTION Any modifications made to this device that are not approved by Carrier will void the authority granted to the user by the FCC to operate this equipment. CE and UKCA Compliance WARNING This is a Class B product. In a light industrial environment, this product may cause radio interference in which case the user may be required to take adequate measures. Industry Canada Compliance This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 25 ©2024 Carrier. All rights reserved. Document revision history Important changes to this document are listed below. Minor changes such as typographical or formatting errors are not listed. Date 9/11/24 Topic Inputs * For internal use only Change description Removed Precon Type 3 Thermistor Code* X-PM-DD-E TruVuTM I/O Expanders (part no. TV-UCXPIO48) Installation and Start-up Guide Carrier Proprietary and Confidential 26 ©2024 Carrier. All rights reserved. Carrier ©2024 · Catalog No. 11-808-1009-01 · 9/11/2024