User Guide for Klima models including: C16WiFi Basic WiFi Thermostat For Electric Floor Heating, C16WiFi, Basic WiFi Thermostat For Electric Floor Heating, WiFi Thermostat For Electric Floor Heating, Electric Floor Heating, Floor HeatingHeating
WS | Unterputz-Raumthermostat digital C16 WiFi
C16WiFi / Basic 5. Explanation of symbols thermostat on. The thermostat is operated by means of the 3 touch-sensitive buttons 1. Introduction Study this manual carefully and keep it with the warranty documents. Connection must be carried regulations. Before mounting or dismounting in the meter cupboard. This thermostat can be deep in accordance with standard DIN formats. These regulations describe the C16 Basic and the C16 WiFi version. Voltage Max. load Standby voltage Temp. range Housing Standard colour Sensor Warranty Approvals Manufacturer 86 : 230V - 50/60 Hz : Max. 16 Amp / 230V : C16 Basic: 1W / C16 WiFi: 2W : +5/+40ºC : IP21 : Polar white (RAL 9010) : Floor sensor and build in Air sensor : 2 years manufacturer's warranty : FI / CE : MHGroup B.V. Netherlands 51 11 9 26 86 52 59 Display Touch sensitive keys Down (touch-sensitive key) Up (touch-sensitive key) WiFi indicator Hello Clock Room temperature Floor temperature Set up 6. Startup menu will be updated automatically after connection. Clock (CLK) Current temperature Heating Percentage Current period (Smart Mode) Key lock Frost protection mode Manual mode House 3. Assembly 1. 2. Connect the thermostat according to the connection diagram (point 4). 3. 4. Put the frame on it and click the display back into place. 1. 2. 3. 4. Choose Day Choose Hour Sensor selection (5 options) Choose Minutes 4. Wiring diagram meter cupboard. Recommendation: Keep the maximum load around 90% of the 16A to extend the service life. ROOM -OUT SENSOR FLOOR SENSOR : Floor sensor connection ROOM OUT SENSOR: External room sensor connection POWER FLOOR SENSOR N1 Heating cable connection wire* L1 Heating cable connection wire* // //- - -- 4 $40&./4043 108&3 85V-265V 50/60Hz ."9-0"% " FLOOR SENSOR *1 N Power supply (Neutral) L Power supply (Phase) EARTH : Connect the earth of the heating cable and the earth of the power supply outside the thermostat using the supplied terminal block. * Order L1 or N1 does not apply. 1. Floor sensor 2. Room sensor 3. 4. External room sensor 5. of 28 degrees! 7. WiFi Connection (C16 WiFi version only) Step 1: Download the App via the QR code or by searching for "Warmme" in the App Store or Google Play store. Step 2: Start the App and create or log in with an existing account. Step 3: On thermostat: Simultaneously press and for Step 4: Click on "Add device" at the bottom of the screen. Step 5: Step 6: Click "Done" after the App has connected to the thermostat and the connection is complete. Step 7: You can check, adjust or set the current temperature, turn the thermostat on You can use the App to give other people in your family access to or exclude multiple thermostats. Google Assistant or Amazon Alexa Via a Google or Amazon supported speaker you can set the temperature of your thermostat higher or lower or ask what the current temperature is. Connecting to Google Assistant or Amazon Alexa is explained in the App. In the App, go to your 8. Function and operation 8.1 Temporary temperature On the main screen, press or to set the temporary temperature. This temporary temperature is active until the start of the next heating period. 8.2 Mode On the main screen, press to select the following modes: Smart mode: This is the default mode. The thermostat operates on the basis of the set heating schedule in order to save energy. Manual mode: Thermostat operates on the basis of the manually set temperature. Frost protection mode: The thermostat will operate with the low set temperature. The maximum is 15oC. 8.3 Key lock Lock all keys to prevent settings from being changed. On the main screen, press and simultaneously for 3 seconds to lock or unlock. 8.4 Menu On the main screen press and hold for 3 seconds to activate the menu. CLK Set day and time (8.4.1) EVE Set schedule (8.4.2) READ Read consumption in % (8.4.3) SET Advanced settings (8.4.4) END Return to main screen 8.4.1 Clock (CLK) Day, hour and minutes can be adjusted here via or . With the WiFi version it is automatically updated after connection. 8.4.2 Programming periods (EVE) In MENU, press or to select EVE. The standard program can be adjusted on the thermostat via or . · First choose the day via or (This can be done per day or as a cluster monday to friday and saturday/sunday separately). · Then choose an event: Awake Departure Return Sleep · Next step is to set the (start or end time). · desired temperature and the lowering temperature may be approx. 3oC as main heating and max. 5oC as auxiliary heating. Repeat this until all periods and days have been programmed. If you have a WiFi thermostat, you can do this easily via the App. Standard program for home use: Home Mon - Fri Sat - Sun Start period 1 06:00 20.0oC 06:00 20.0oC End period 1 08:30 15.0oC 08:30 20.0oC Start period 2 17:00 20.0oC 17:00 20.0oC End period 2 23:00 15.0oC 23:00 15.0oC Mon - Fri Sat - Sun Start work day 07:00 20.0oC 07:00 20.0oC End work day 18:00 15.0oC 18:00 15.0oC 8.4.3 Consumption (READ) Displays the warm-up time (in percent) within a given period (1.30 or 365 days). In MENU, press or to select READ. Press o to view the previous day's consumption. Press or to display the consumption of 1 day, 30 days or 365 days. Example: The consumption is 20% and the installed power 300 Watt 20% x 300Watt = 60 Watt consumption per hour. 60W x 24 hours = 1.440 Watt consumption per day. Press to return to the main menu. 8.4.4 Advanced Settings (SET) PLEASE NOTE: Settings in this menu may only be adjusted in consultation with the supplier/installer to prevent unwanted results. In MENU, press or to select SET. 1. Sensor selection 2. Room temp. calibration 3. Floor temperature calibration 4. Floor temperature limit 5. Schedule selection 6. Used for heating or cooling 7. Intelligent function. This function ensures that the requested temperature has already been reached when the period starts. 8. 9. Reset to factory settings Each setting can be adjusted via or Full schedule: No. Function Default setting 1. Sensor selection 00: Floor sensor . Options 00: Floor sensor 01: Room sensor 03: External room sensor 2. Room temperature calibration 0.0oC 3. Floor temperature calibration 0.0oC 4. 35.0oC 5. Schedule 00: 7 days 6. Used for 00: Heating 7. Intelligent function 00: On 8. Location Reset 00: Home 00: No -5.0oC - 5.0oC -5.0oC - 5.0oC 20.0oC - 50.0oC 00: 7 days 01: Mon to Fri + Sat + Sun 00: Heating 01: Cooling (only for water based systems) 00: On 00: Home 00: No 01: Reset 8.5 Open window detection automatically for 15 minutes when it detects a rapid drop in temperature. 9. Error messages E1: Room sensor fault E2: Floor sensor fault E3: Sensor error external sensorAdobe Illustrator 25.0 (Windows) Adobe PDF library 15.00