User Guide for Klima models including: C16WiFi Basic WiFi Thermostat For Electric Floor Heating, C16WiFi, Basic WiFi Thermostat For Electric Floor Heating, WiFi Thermostat For Electric Floor Heating, Electric Floor Heating, Floor HeatingHeating

Print

90 072 86--DBL-01-en 3,8 MB

WS | Unterputz-Raumthermostat digital C16 WiFi

PDF preview unavailable. Download the PDF instead.

90 072 86--DBL-01-en
C16WiFi / Basic

5. Explanation of symbols
thermostat on. The thermostat is operated by means of the 3 touch-sensitive buttons

1. Introduction
Study this manual carefully and keep it with the warranty documents. Connection must be carried
regulations. Before mounting or dismounting
in the meter cupboard. This thermostat can be
deep in accordance with standard DIN formats. These regulations describe the C16 Basic and the C16 WiFi version.

Voltage Max. load Standby voltage Temp. range Housing Standard colour Sensor Warranty Approvals Manufacturer
86

: 230V - 50/60 Hz : Max. 16 Amp / 230V : C16 Basic: 1W / C16 WiFi: 2W : +5/+40ºC : IP21 : Polar white (RAL 9010) : Floor sensor and build in Air sensor : 2 years manufacturer's warranty : FI / CE : MHGroup B.V. Netherlands
51

11 9 26

86

52

59

Display Touch sensitive keys

Down (touch-sensitive key) Up (touch-sensitive key) WiFi indicator Hello Clock Room temperature Floor temperature Set up
6. Startup menu
will be updated automatically after connection. Clock (CLK)

Current temperature Heating Percentage Current period (Smart Mode) Key lock Frost protection mode Manual mode
House

3. Assembly

1. 2. Connect the thermostat according to the connection diagram (point 4). 3. 4. Put the frame on it and click the display back into place.

1.

2.

3.

4.

Choose Day

Choose Hour

Sensor selection (5 options)

Choose Minutes

4. Wiring diagram

meter cupboard.

Recommendation: Keep the maximum load around 90% of the 16A to extend the service life.

ROOM -OUT SENSOR

FLOOR SENSOR : Floor sensor connection ROOM OUT SENSOR: External room sensor connection

POWER

FLOOR SENSOR N1 Heating cable connection wire* L1 Heating cable connection wire*

// //- - -- 4 $40&./4043

108&3 85V-265V 50/60Hz
."9-0"% "

FLOOR SENSOR

*1

N Power supply (Neutral) L Power supply (Phase)
EARTH : Connect the earth of the heating cable and the earth of the power supply outside the thermostat using the supplied terminal block.

* Order L1 or N1 does not apply.

1. Floor sensor 2. Room sensor 3. 4. External room sensor 5.
of 28 degrees!

7. WiFi Connection (C16 WiFi version only)
Step 1: Download the App via the QR code or by searching for "Warmme" in the App Store or Google Play store.
Step 2: Start the App and create or log in with an existing account. Step 3: On thermostat: Simultaneously press  and for
Step 4: Click on "Add device" at the bottom of the screen.
Step 5:
Step 6: Click "Done" after the App has connected to the thermostat and the connection is complete.
Step 7: You can check, adjust or set the current temperature, turn the thermostat on
You can use the App to give other people in your family access to or exclude multiple thermostats.
Google Assistant or Amazon Alexa Via a Google or Amazon supported speaker you can set the temperature of your thermostat higher or lower or ask what the current temperature is. Connecting to Google Assistant or Amazon Alexa is explained in the App. In the App, go to your

8. Function and operation
8.1 Temporary temperature On the main screen, press  or  to set the temporary temperature. This temporary temperature is active until the start of the next heating period.

8.2 Mode On the main screen, press  to select the following modes:
Smart mode: This is the default mode. The thermostat operates on the basis of the set heating schedule in order to save energy.
Manual mode: Thermostat operates on the basis of the manually set temperature.
Frost protection mode: The thermostat will operate with the low set temperature. The maximum is 15oC.

8.3 Key lock
Lock all keys to prevent settings from being changed. On the main screen, press  and simultaneously for 3 seconds to lock or unlock.

8.4 Menu

On the main screen  press and hold for 3 seconds to activate the menu.

CLK

Set day and time (8.4.1)

EVE

Set schedule (8.4.2)

READ

Read consumption in % (8.4.3)

SET

Advanced settings (8.4.4)

END

Return to main screen

8.4.1 Clock (CLK)

Day, hour and minutes can be adjusted here via  or 

.

With the WiFi version it is automatically updated after connection.

8.4.2 Programming periods (EVE)

In MENU, press  or  to select EVE. The standard program can be adjusted on the

thermostat via  or 

.

· First choose the day via  or  (This can be done per day or as a cluster monday to friday and saturday/sunday separately).
· Then choose an event:

Awake Departure Return Sleep · Next step is to set the (start or end time). ·
desired temperature and the lowering temperature may be approx. 3oC as main heating and max. 5oC as auxiliary heating.
Repeat this until all periods and days have been programmed. If you have a WiFi thermostat, you can do this easily via the App.

Standard program for home use:

Home
Mon - Fri Sat - Sun

Start period 1
06:00 20.0oC
06:00 20.0oC

End period 1
08:30 15.0oC
08:30 20.0oC

Start period 2
17:00 20.0oC
17:00 20.0oC

End period 2
23:00 15.0oC
23:00 15.0oC

Mon - Fri Sat - Sun

Start work day
07:00 20.0oC
07:00 20.0oC

End work day
18:00 15.0oC
18:00 15.0oC

8.4.3 Consumption (READ) Displays the warm-up time (in percent) within a given period (1.30 or 365 days). In MENU, press  or  to select READ.
Press o to view the previous day's consumption. Press  or  to display the consumption of 1 day, 30 days or 365 days.

Example: The consumption is 20% and the installed power 300 Watt 20% x 300Watt = 60 Watt consumption per hour. 60W x 24 hours = 1.440 Watt consumption per day.
Press  to return to the main menu.

8.4.4 Advanced Settings (SET) PLEASE NOTE: Settings in this menu may only be adjusted in consultation with the supplier/installer to prevent unwanted results. In MENU, press  or  to select SET.

1. Sensor selection 2. Room temp. calibration 3. Floor temperature calibration 4. Floor temperature limit 5. Schedule selection 6. Used for heating or cooling 7. Intelligent function. This function ensures that the requested temperature has
already been reached when the period starts. 8. 9. Reset to factory settings

Each setting can be adjusted via  or  Full schedule:

No. Function

Default setting

1. Sensor selection

00: Floor sensor

.
Options 00: Floor sensor 01: Room sensor 03: External room sensor

2. Room temperature calibration 0.0oC

3. Floor temperature calibration 0.0oC

4.

35.0oC

5. Schedule

00: 7 days

6. Used for

00: Heating

7. Intelligent function

00: On

8. Location  Reset

00: Home 00: No

-5.0oC - 5.0oC -5.0oC - 5.0oC 20.0oC - 50.0oC 00: 7 days 01: Mon to Fri + Sat + Sun 00: Heating 01: Cooling (only for water based systems) 00: On
00: Home
00: No 01: Reset

8.5 Open window detection

automatically for 15 minutes when it detects a rapid drop in temperature.
9. Error messages
E1: Room sensor fault E2: Floor sensor fault E3: Sensor error external sensor


Adobe Illustrator 25.0 (Windows) Adobe PDF library 15.00