Datasheet for Tektronix models including: TMDP0200, THDP0200, THDP0100, P5200A, P5202A, P5205A, P5210A, High-voltage Differential Probes
Apr 30, 2021 — Tektronix offers a broad portfolio of high-voltage probing solutions that enable users to safely and accurately make floating measurements.
Ordering information Standard accessories P5200A, P5202A, and P5205A Description Quantity included Reorder part number Hook clips 1 set of red and black hook clips AC280-FL
File Info : application/pdf, 6 Pages, 964.33KB
DocumentDocumentHigh-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A Tektronix offers a broad portfolio of high-voltage probing solutions that enable users to safely and accurately make floating measurements. Key performance specifications · Bandwidths up to 200 MHz · Up to 6000 V differential (DC + pk AC) · Up to 2300 V common (RMS) Key features · Overrange Indicator · Safety Certified · Switchable Attenuation · Switchable bandwidth limit Applications · Floating measurements · Switching power supply design · Motor drive design · Electronic ballast design · CRT display design · Power converter design and service · Power device evaluation Connectivity · BNC interface (P5200A probes) · TekVPI® interface (TMDP and THDP Series probes) · TekProbe® interface (P5202A, P5205A, and P5210A Series probes) Safe high-voltage probe solutions The THDP0100 and P5210A have the largest differential dynamic range capability from Tektronix, allowing users to safely measure up to ±6000 V. The THDP0100 supports bandwidths up to 100 MHz and slew rates up to 2500 V/ns at 1/1000 gain. These probes are supplied with two sizes of hook tips and have an overrange visual and audible indicator which warns the user when they are exceeding the linear range of the probe. The THDP0200 and P5205A are active differential probes that are capable of safely measuring differential voltages up to ±1500 V. The probes are effective in making measurements in IGBT circuits such as motor drives and power converters. The THDP0200 supports bandwidths up to 200 MHz and slew rates up to 275 V/ns at 1/250 gain. The TMDP0200 and P5202A are designed for medium-voltage applications with differential requirements up to ±750 V. These probes have lower attenuation ranges and offer better signal-to-noise ratio. The P5200A can be used with any oscilloscope and enables users to safely make measurements of floating circuits with their oscilloscope grounded. The P5200A Active Differential Probe converts floating signals to low-voltage ground-referenced signals that can be displayed safely and easily on any ground-referenced oscilloscope. Warning: For safe operation, do not use the P5200A High-voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 and THS3000 Series oscilloscopes. The P5200A High-voltage Differential Probe requires an oscilloscope or other measurement instrument with grounded inputs. Connectivity options The TMDP and THDP Series probes are equipped with the TekVPI® interface which allows smart communication between the oscilloscope and probe. Pushing the probe menu button will launch the probe control menu on the oscilloscope display providing access to all relevant probe settings and controls. These probes are designed to operate on TekVPI® oscilloscopes without requiring the TPA-BNC adapter. The P52xxA Series probes are equipped with the Tektronix TekProbe® interface which communicates scale information to the oscilloscope. Direct connections can be made to oscilloscopes configured with the TekProbe® interface or to any oscilloscope when used with the 1103 TekProbe® Power Supply. www.tek.com 1 High Voltage Differential Probe Datasheet Specifications All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. Model overview ProbesTekVPI Table 1: Probes with the TekVPI® interface Attenuation Differential Voltage TMDP0200 25X / 250X 250X: ±750 V 25X: ±75 V THDP0200 50X / 500X 500X: ±1500 V 50X: ±150 V THDP0100 100X / 1000X 1000X: ±6000 V 100X: ±600 V Common Mode Voltage Maximum Input Voltage-to-Earth ±750 V 550 V CAT I 300 V CAT III ±1500 V 1000 V CAT II 600 V CAT III ±6000 V 2300 V CAT I 1000 V CAT III Bandwidth Rise Time Slew Rate Input Impedance at the Probe Tip Typical CMRR 200 MHz <1.8 ns <275 V/ns at 1/250 gain 5 M || <2 pF DC: > -80 dB 100 kHz: > -60 dB 3.2 MHz: > -30 dB 100 MHz: > -26 dB 200 MHz <1.8 ns <650 V/ns at 1/500 gain 10 M || <2 pF DC: > -80 dB 100 kHz: > -60 dB 3.2 MHz: > -30 dB 100 MHz: > -26 dB 100 MHz <3.5 ns <2500 V/ns at 1/1000 gain 40 M || <2.5 pF DC: > -80 dB 100 kHz: > -60 dB 3.2 MHz: > -30 dB 100 MHz: > -26 dB Cable Length 1.5 m 1.5 m 1.5 m ProbesTekProbe Table 2: Probes with the BNC and TekProbe® interface P5200A P5202A P5205A P5210A Attenuation 50X / 500X 20X / 200X 50X / 500X 100X / 1000X Differential Voltage 500X: ±1300 V 50X: ±130 V 200X: ±640 V 20X: ±64 V 500X: ±1300 V 50X: ±130 V 1000X: ±5600 V 100X: ±560 V Common Mode Voltage ±1300 V ±640 V ±1300 V ±5600 V Maximum Input Voltage-toEarth 1000 V CAT II 450 V CAT l 300 V CAT ll 1000 V CAT II 2300 V CAT l 1000 V CAT III Bandwidth 50 MHz 100 MHz 100 MHz 50 MHz Differential Input Impedance 10 M || 2 pF 5 M || 2 pF 10 M || 2 pF 40 M || 2.5 pF Input Impedance between each 5 M || 4 pF Input and Ground Table continued... 2.5 M || 4 pF 5 M || 4 pF 20 M || 5 pF www.tek.com 2 Typical CMRR Cable length THDP0200 probe label P5200A DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >30 dB 50 MHz: >26 dB 1.8 m P5202A DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >40 dB 50 MHz: >30 dB High Voltage Differential Probe Datasheet P5205A P5210A 1. The differential voltages the maximum measurable range between the (+) and (-) input leads of the probe. Beyond these limits, the output could be clipped. 2. The maximum common mode voltage and maximum input voltage-to-earth (RMS) are the maximum voltages that each input lead (+/-) can be from ground. www.tek.com 3 High Voltage Differential Probe Datasheet Ordering information Standard accessories P5200A, P5202A, and P5205A Description Hook clips Pincer clips Alligator clips Extension cables TMDP0200 and THDP0200 Quantity included 1 set of red and black hook clips 1 set of red and black pincer clips 1 set of red and black alligator clips 1 set of red and black extension cables Description Hook clips Pincer clips Alligator clips Extension cables Test leads Probe holder THDP0100 and P5210A Quantity included 2 2 2 2 2 1 Description Probe tips Large hook clips Small hook clips Quantity included 2 2 2 Probe and accessory derating table Common mode, relative to ground, when used with P52xxA Series probes Accessory Description TMDP0200 / P5202A 450 V CAT I 300 V CAT II 196-3523-00 AC280-FL Table continued... 2x Extender Leads (1.5 m) 2300 V CAT I 1000 V CAT III Standard 450 V CAT I 300 V CAT II 2x Hook Clips 1000 V CAT III 600 V CAT IV Standard 450 V CAT I 300 V CAT II 1 The TP175 must be ordered through Fluke. Reorder part number AC280-FL AC283-FL AC285-FL 196-3523-00 Reorder part number AC280-FL AC283-FL AC285-FL 196-3523-00 TP1751 TPH1000 Reorder kit part number 020-3070-00 THDP0200 / P5200A / P5205A 1000 V CAT II 600 V CAT III Standard 1000 V CAT II 600 V CAT III Standard 1000 V CAT II 600 V CAT III THDP0100 / P5210A 2300 V CAT I 1000 V CAT III Standard 2300 V CAT I 1000 V CAT III Optional 1000 V CAT I 1000 V CAT III www.tek.com 4 High Voltage Differential Probe Datasheet Accessory Description TMDP0200 / P5202A 450 V CAT I 300 V CAT II AC283-FL AC285-FL 2 020-3070-00 TP175 2x Pincer Clips 1000 V CAT III 600 V CAT IV 2x Alligator Clips 1000 V CAT III 600 V CAT IV Hook Clip Kit 2300 V CAT I 1000 V CAT II 2x Test Leads 1000 V CAT III 600 V CAT IV Standard 450 V CAT I 300 V CAT II Standard 450 V CAT I 300 V CAT II Optional 450 V CAT I 300 V CAT II Standard (TMDP0200) 550 V CAT I 300 V CAT III Options Power plug options (P5200A only) Opt. A0 Opt. A1 Opt. A2 Opt. A3 Opt. A4 Opt. A5 Opt. A6 Opt. A10 Opt. A11 Opt. A12 Opt. A99 North America power plug (115 V, 60 Hz) Universal Euro power plug (220 V, 50 Hz) United Kingdom power plug (240 V, 50 Hz) Australia power plug (240 V, 50 Hz) North America power plug (240 V, 50 Hz) Switzerland power plug (220 V, 50 Hz) Japan power plug (100 V, 50/60 Hz) China power plug (50 Hz) India power plug (50 Hz) Brazil power plug (60 Hz) No power cord Service options Opt. C3 Opt. C5 Opt. D1 Opt. D3 Calibration Service 3 Years Calibration Service 5 Years Calibration Data Report Calibration Data Report 3 Years (with Opt. C3) THDP0200 / P5200A / P5205A 1000 V CAT II 600 V CAT III Standard 1000 V CAT II 600 V CAT III Standard 1000 V CAT II 600 V CAT III Optional 1000 V CAT II 600 V CAT II Standard (THDP0200) 1000 V CAT II 600 V CAT III THDP0100 / P5210A 2300 V CAT I 1000 V CAT III Optional 1000 V CAT I 1000 V CAT III Optional 1000 V CAT I 1000 V CAT III Standard 2300 V CAT I 1000 V CAT II Optional 2300 V CAT I 1000 V CAT III 2 To prevent damage to the insulation on the AC285-FL alligator clips, do not use in high A/m magnetic fields at high frequencies, which can cause induction heating of the jaws. www.tek.com 5 High Voltage Differential Probe Datasheet Opt. D5 Opt. R3 Opt. R5 Opt. SILV200 Calibration Data Report 5 Years (with Opt. C5) Repair Service 3 Years (including warranty) Repair Service 5 Years (including warranty) Standard warranty extended to 5 years Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms. The P52xxA Series probes provide high-voltage differential measurement solutions for any oscilloscope. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. ASEAN / Australasia (65) 6356 3900 Belgium 00800 2255 4835* Central East Europe and the Baltics +41 52 675 3777 Finland +41 52 675 3777 Hong Kong 400 820 5835 Japan 81 (120) 441 046 Middle East, Asia, and North Africa +41 52 675 3777 People's Republic of China 400 820 5835 Republic of Korea +822 6917 5084, 822 6917 5080 Spain 00800 2255 4835* Taiwan 886 (2) 2656 6688 * European toll-free number. If not accessible, call: +41 52 675 3777 Austria 00800 2255 4835* Brazil +55 (11) 3759 7627 Central Europe & Greece +41 52 675 3777 France 00800 2255 4835* India 000 800 650 1835 Luxembourg +41 52 675 3777 The Netherlands 00800 2255 4835* Poland +41 52 675 3777 Russia & CIS +7 (495) 6647564 Sweden 00800 2255 4835* United Kingdom & Ireland 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Canada 1 800 833 9200 Denmark +45 80 88 1401 Germany 00800 2255 4835* Italy 00800 2255 4835* Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Norway 800 16098 Portugal 80 08 12370 South Africa +41 52 675 3777 Switzerland 00800 2255 4835* USA 1 800 833 9200 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com. Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 30 Apr 2021 51W-11195-14 www.tek.comAH XSL Formatter V7.0 MR4 for Windows (x64) : 7.0.5.46841 (2020-08-31T10:02 09) Antenna House PDF Output Library 7.0.1604