User Manual for LG models including: ARNU073MAA4 Ceiling Concealed Duct Mid Static Air Conditioner, ARNU073MAA4, Ceiling Concealed Duct Mid Static Air Conditioner, Concealed Duct Mid Static Air Conditioner, Duct Mid Static Air Conditioner, Static Air Conditioner, Air Conditioner, Conditioner

MFL71985901

KMH

Multi V Air Conditioner - SVC MANUAL(Exploded View)

19 apr 2024 — Before Servicing the unit, read the safety precautions in General SVC manual. ... Wireless Remote Controller. 1. -. -. -. -. 3/3/3 ... Only training and service ...


File Info : application/pdf, 10 Pages, 29.69MB

PDF preview unavailable. Download the PDF instead.

SM Multi V Mid Static Ducted IDU
Multi V Air Conditioner SVC MANUAL(Exploded View)

MODEL :

ARNU073MAA4 ARNU093MAA4 ARNU123MAA4 ARNU153MAA4 ARNU183MAA4 ARNU243MAA4

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

1. Specification

Type

Model

Unit

kW

Cooling Capacity

kcal/ h

Btu/ h

kW

Heating Capacity

kcal/ h

Btu/ h

Casing

Dimensions (W x H x D)

mm Body
inch

Rows x Columns x FPI

Coil

Face Area

m2(sq.ft)

Type

Motor Output x Number

W

Running Current

A

Fan

Air Flow Rate(H/ M/ L)

CMM

(High Mode-Factory Set)

CFM

Ext Static Pressure mmAq(in.Aq)

Drive

Motor Type

Temperature Control

Sound Absorbing Thermal I nsulation Material

Air Filter

Safety Divice

Pipe Connections

Liquid Side Gas Side
Drain Pipe(I nternal Dia.)

mm(inch) mm(inch) mm(inch)

Net Weight

Body

kg(lbs)

Sound Pressure Level (H/ M/ L)

dB(A)+1

Power Supply Refrigerant Control

Ø, V, Hz -

Communication Cable(VCTF-SB)

AWG × cores

Ceiling Concealed Duct -Mid Static

ARNU073MAA4

ARNU093MAA4

ARNU123MAA4

2.20

2.80

3.60

1,900

2,400

3,100

7,500

9,600

12,300

2.50

3.20

4.00

2,200

2,800

3,400

8,500

10,900

13,600

Galvanized Steel Plate

Galvanized Steel Plate

Galvanized Steel Plate

900 x 245 x 700

900 x 245 x 700

900 x 245 x 700

35-7/ 16 x 9-21/ 32 x 27-9/ 16 35-7/ 16 x 9-21/ 32 x 27-9/ 16 35-7/ 16 x 9-21/ 32 x 27-9/ 16

2 × 13 × 18

2 x 13 x 18

2 x 13 x 18

0.19 (2.05)

0.19 (2.05)

0.19 (2.05)

Sirocco Fan

Sirocco Fan

Sirocco Fan

165 x 1

165 x 1

165 x 1

1.7

1.7

1.7

8/ 7/ 6

10 / 9 / 8

14 / 12 / 10

283 / 247 / 212

353 / 318 / 283

494 / 424 / 353

6(0.24)

6(0.24)

6(0.24)

Direct

Direct

Direct

BLDC

BLDC

BLDC

Microprocessor, Thermostat for Microprocessor, Thermostat for Microprocessor, Thermostat for

cooling and heating

cooling and heating

cooling and heating

Foamed polystrene

Foamed polystrene

Foamed polystrene

Pre-filter

Pre-filter

Pre-filter

Fuse

Fuse

Fuse

6.35 (1/ 4)

6.35 (1/ 4)

6.35 (1/ 4)

12.7 (1/ 2)

12.7 (1/ 2)

12.7 (1/ 2)

25 (1)

25 (1)

25 (1)

28.4(62.6)

28.4(62.6)

28.4(62.6)

28 / 27 / 25

28 / 27 / 26

31 / 29 / 28

1, 208 / 230, 60

1, 208 / 230, 60

1, 208 / 230, 60

EEV

EEV

EEV

AWG 18 x2C

AWG 18 x2C

AWG 18 x 2C

Notes: 1. Capacities are based on the following conditions:
Cooling · Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB · Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB · Interconnecting Piping Length 7.5m(24.6ft) · Level Difference of Zero
Heating · Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB · Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB · Interconnecting Piping Length 7.5m(24.6ft) · Level Difference of Zero
2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve 6. Noise Level is High Mode (factory set)

Conversion Formula
kcal/h= kW x 860 Btu/h = kW x 3412 cfm = m3/min x 35.3 l/s = CMM x 1000/60

-2-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

1. Specification

Type

Model

Unit

kW

Cooling Capacity

kcal/ h

Btu/ h

kW

Heating Capacity

kcal/ h

Btu/ h

Casing

Dimensions (W x H x D)

mm Body
inch

Rows x Columns x FPI

Coil

Face Area

m2(sq.ft)

Type

Motor Output x Number

W

Running Current

A

Fan

Air Flow Rate(H/ M/ L)

CMM

(High Mode-Factory Set)

CFM

Ext Static Pressure mmAq(in.Aq)

Drive

Motor Type

Temperature Control

Sound Absorbing Thermal I nsulation Material

Air Filter

Safety Divice

Pipe Connections

Liquid Side Gas Side
Drain Pipe(I nternal Dia.)

mm(inch) mm(inch) mm(inch)

Net Weight

Body

kg(lbs)

Sound Pressure Level (H/ M/ L)

dB(A)+1

Power Supply

Ø, V, Hz

Refrigerant Control

-

Communication Cable(VCTF-SB)

AWG × cores

Ceiling Concealed Duct -Mid Static

ARNU153MAA4

ARNU183MAA4

ARNU243MAA4

4.50

5.60

7.10

3,900

4,800

6,100

15,400

19,100

24,200

5.00

6.30

8.00

4,300

5,400

6,900

17,100

21,500

27,300

Galvanized Steel Plate

Galvanized Steel Plate

Galvanized Steel Plate

900 x 245 x 700

900 x 245 x 700

900 x 245 x 700

35-7/ 16 x 9-21/ 32 x 27-9/ 16 35-7/ 16 x 9-21/ 32 x 27-9/ 16 35-7/ 16 x 9-21/ 32 x 27-9/ 16

2 x 13 x 18

2 x 13 x 18

3 x 13 x 18

0.19 (2.05)

0.19 (2.05)

0.19 (2.05)

Sirocco Fan

Sirocco Fan

Sirocco Fan

165 x 1

165 x 1

165 x 1

1.7

1.7

1.7

15 / 12 / 11

18 / 15 / 12

20 / 15.5 / 13

530 / 424 / 388

635 / 530 / 424

706 / 547 / 459

6(0.24)

6(0.24)

6(0.24)

Direct

Direct

Direct

BLDC

BLDC

BLDC

Microprocessor, Thermostat for Microprocessor, Thermostat for Microprocessor, Thermostat for

cooling and heating

cooling and heating

cooling and heating

Foamed polystrene

Foamed polystrene

Foamed polystrene

Pre-filter

Pre-filter

Pre-filter

Fuse

Fuse

Fuse

6.35 (1/ 4)

6.35 (1/ 4)

9.52 (3/ 8)

12.7 (1/ 2)

12.7 (1/ 2)

15.88 (5/ 8)

25 (1)

25 (1)

25 (1)

28.4(62.6)

28.4(62.6)

29.7(65.5)

33 / 31 / 29

36 / 32 / 29

38 / 33 / 30

1, 208 / 230, 60

1, 208 / 230, 60

1, 208 / 230, 60

EEV

EEV

EEV

AWG 18 x 2C

AWG 18 x 2C

AWG 18 x 2C

Notes:1. Capacities are based on the following conditions:
Cooling · Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB · Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB · Interconnecting Piping Length 7.5m(24.6ft) · Level Difference of Zero
Heating · Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB · Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB · Interconnecting Piping Length 7.5m(24.6ft) · Level Difference of Zero
2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve 6. Noise Level is High Mode (factory set)

Conversion Formula
kcal/h= kW x 860 Btu/h = kW x 3412 cfm = m3/min x 35.3 l/s = CMM x 1000/60

-3-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

2. List of Functions

Category

Function

Air flow
Air purifying Installation Reliability
Convenience
Individual control

Air supply outlet
Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing
Chaos wind(auto wind) Jet cool(Power wind) Swirl wind
Deodorizing filter Plasma air purifier Prefilter(washable) Drain pump
E.S.P. control Electric heater(operation) High ceiling operation
Vertical installation kit Hot start
Self diagnosis
Auto changeover
Auto cleaning
Auto operation(artificial intelligence) Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off) Timer(weekly) Two thermistor control
LG Multi SITETM
Remote Controller
(With Occupancy Sensor) LG Multi SITETM
Remote Controller
Premium Simple
Wireless Remote Controller

ARNU073MAA4, ARNU093MAA4, ARNU123MAA4 ARNU153MAA4, ARNU183MAA4, ARNU243MAA4
1 3/3/3 X X O O O X ABDAMA0 O O O (Heat recovery only) O O (Heat pump or cooling only) O O O O O O O
PREMTBVC1
PREMTBVC0
PREMTA000 PREMTC00U PQWRHQ0FDB

O : Applied

X : Not applied ­ : No relation

Option : Model name & price are different according to options, and assembled in factory with main unit.

Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate

package.

-4-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

3. Piping Diagrams MA Chassis

Heat Exchanger

EEV
Filter

Th3

Th2

Sirocco Fan

Filter

Th1

lndoor unit

:Cooling :Heating

CHASSIS
MA
LOC. Th1 Th2 Th3

Refrigerant pipe connection port diameter

MODEL ARNU073MAA4 ARNU093MAA4 ARNU123MAA4 ARNU153MAA4 ARNU183MAA4 ARNU243MAA4

GAS Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)

Description Thermistor for room air temperature Thermistor for pipe in temperature Thermistor for pipe out temperature

[Unit : mm(inch)]
LIQUID Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
PCB Connector (Color) CN_ROOM (Yellow) CN_PIPE_IN (White) CN_PIPE_OUT (Red)

-5-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

4. Wiring Diagrams
ARNU073MAA4, ARNU093MAA4, ARNU123MAA4, ARNU153MAA4, ARNU183MAA4, ARNU243MAA4

FUSE_H 250 V / T 5 A

L(L1) N(L2)
POWER INPUT

MEZ65014864 Rev.01 020224

CN_PIPE_OUT
CN_REMO
CN_OPTION CN_WF CN_LGMV CN_OPTION CN_485
CN_PTC DIP SWITCH
CN_CC

CN_PIPE_IN CN_FLOAT
CN_ROOM CN_DC_DRAIN

CN_DISPLAY

CN_ZONE CN_EEV CN_EXT

CN_MOTOR1

CN_DAMPER

EARTH1

CN_D_PUMP
CN_POWER FUSE_H

-6-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

5. DIP Switch Setting

1. Indoor Unit

SW1 SW2 SW3 SW4
SW5 SW6 SW7
SW8

Function

Description

Communication N/A (Default)

Setting Off -

Setting On -

Cycle

N/A (Default)

-

-

Group Control Selection of Master or Slave

Master

Slave

Dry Contact Mode Selection of Dry Contact

Wired/Wireless remote

Mode

controller Selection of Manual or Auto

Auto

operation Mode

Installation

Fan continuous operation Continuous operation Removall

-

Heater linkage N/A

-

-

Ventilator linkage Selection of Ventilator linkage

Linkage Removal

Working

Vane selection (Console)

Selection of up/down side Vane

Up side + Down side Vane Up side Vane Only

Region selection Selection tropical region

General model

Tropical model

Etc.

Spare

-

-

Default Off Off Off
Off
Off Off
Off
Off

For Multi V Models, DIP switch 1, 2, 6, 8 must be set OFF.
2. Outdoor Unit
In case that the products meet specific conditions, "Auto addressing" function can start automatically with the improved speed by turning the DIP switch #3 of the outdoor unit and resetting the power. * Specific conditions:
- All names of the indoor units are ARNU****4. - The serial number of Multi V super IV (outdoor units) is after October 2013.
DIP switch 7 segment

Outdoor Unit PCB

Outdoor Unit DIP Switch

- 7-

Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.

137214 237213 739209 137213

237203

159830

W4810A 354210
330871A
739205 237202
W4030A

739207
147901 336600B

336600A 359012A

359012

346810

349600A

W4810B

349600B 349600C 249951

W4810C 739204

55221G 352118 152500A

739202A 249940

EBG13YL

2687S2 2687S1

249941

2687M

W4810D

EBG13RD
EBG13WH 261704
W6642 W6645

437213

W4030B

73920A

137223

237223

W50010 352150B 249950

237205

137211

249310

158591

7. Self-diagnosis function

Error Indicator

· This function indicates types of failure in self-diagnosis and occurrence of failure for air condition. · Error mark is displayed on display window of indoor units and wired remote controller, and 7-segment LED of
outdoor unit control board as shown in the table. · If more than two troubles occur simultaneously, lower number of error code is first displayed. · After error occurrence, if error is released, error LED is also released simultaneously.
Error Display

- 1st,2nd,3rd LED of 7-segment indicates error number, 4th LED indicates unit number. Indicates unit number. (* = 1:Master, 2 : Slave 1, 3 : Slave 2)

Ex) 211 : No.21 error of master unit 213 : No.21 error of slave2 1051 : No.105 error of master unit

(repetition)
Error Compressor Unit(1:Master, 2:Slave 1, 3:Slave 2) Error number

Refer to the DX-Venitilation manual for DX-Venitilation error code

Indoor unit related error

Display 01 02 03 04 05 06 -

Title Air temperature sensor of indoor unit Inlet pipe temperature sensor of indoor unit
Communication error : wired remote controller indoor unit
Drain pump
Communication error : Indoor communication PCB indoor unit
Outlet pipe temperature sensor of indoor unit

0 9 - Indoor EEPROM Error

1 0 - Poor fan motor operation

2 3 0 Refrigerant leakage sensing error

2

3

7

Communication defect in indoor communication PCB outdoor communication PCB

2

3

8

Communication error in outdoor communication PCB outdoor unit

Cause of Error Air temperature sensor of indoor unit is open or short Inlet pipe temperature sensor of indoor unit is open or short
Failing to receive wired remote controller signal in indoor unit PCB
Malfunction of drain pump Indoor Unit PCB did not receive signal from Indoor communication PCB for over 3 minutes continuously Outlet pipe temperature sensor of indoor unit is open or short In case when the serial number marked on EEPROM of Indoor unit is 0 or FFFFFF
Disconnecting the fan motor connector / Failure of indoor fan motor lock Refrigerant leakage sensing error and sensor defect error Indoor communication PCB did not receive signal from outdoor communication PCB for over 3 minutes continuously
Outdoor communication PCB did not receive communication signal from outdoor unit for over 3 minutes continuously

9

4

P/NO : MFL69041304 Copyright © 2024 LG Electronics Inc. All rights reserved. Only training and service purposes.



References

Acrobat Distiller 10.0.0 (Macintosh)