User Manual for SUPER BRIGHT LEDS models including: LPDBL Series Dimmable LED Panel Light, LPDBL Series, Dimmable LED Panel Light, LED Panel Light, Panel Light, Light

PDF preview unavailable. Download the PDF instead.

LPDBL manual
Important: Read all instructions prior to installation.
Dimmable LED Panel Light

Dimensional Drawings
LPDBL-xK24-50-S

23.75in 603.25mm

User Manual
LPDBL Series

47.75in 1212.85mm

1.61in 40.64mm

Dimmable LED Panel Light
LPDBL Series
User Manual

2.46in 62.48mm
3/4 INCH CONDUIT KNOCKOUT

1.77in 44.96mm

LPDBL-xK22-40-S

23.75in 603.25mm

2.12in 53.85mm

1.77in 44.96mm
Rev Date: V1 07/01/2019

23.75in 603.25mm

1.50in 37.97mm

LPDBL-40K24-50-S
Rev Date: V1 07/01/2019

Important: Read all instructions prior to installation.
Dimmable LED Panel Light

User Manual
LPDBL Series

Included Parts 1 - LED panel Light

Recommended Accessories

· 0­10V Slide Dimmer (F019) · 0­10V Knob Dimmer (A019)

Specifications

Model Dimmable Operating Temperature IP Rating Product Weight

LPDBL-xK22-40-S

LPDBL-xK24-50-S

0­10 V

-4°­113° F(-20°­45° C)

IP20

4.45 lb (2 kg)

9.1 lb (4.1 kg)

Check product label for specific electrical specifications related to installation. Improper installation will void warranty.

Safety Information

· Product should be installed by a certified electrician in accordance with applicable national, state, and local building and electrical codes.
· To reduce the risk of electric shock, ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures.
· Avoid looking directly into the light when illuminated. · Failure to properly support the fixture may result in damage or injury, for
which the manufacturer does not assume responsibility. A safety cable is not included, but it is recommended that one be connected to grid clip
during installation.

Wiring Diagram
100­277 VAC Supply
0­10 V Dimmer

Black White Green
Purple Gray

L

L

N

N

GND GND

+

+

­

­

Black White Green
Purple Gray/Pink

Drop Ceiling Installation

1. Turn supply power to circuit off. If installing as a retrofit, remove existing fixture. 2. Open driver box and remove knockout(s) for wiring. Make electrical connections
using wiring diagram. Once complete, resecure driver box cover.

FIG 1

Firmly bend Safety Tabs up and out

Safety Tab

3. Bend out safety tab to be vertical, then upper portion out 90 degrees.
It is recommended that a safety cable (included) be installed to anchor the fixture as well. 4. Lay fixture into T-grid.

FIG 2

Fixture

Safet Tab

T-Grid

Driver Box

Note: Tabs should secure light in
T-grid while still allowing reinstallation of adjacent ceiling tiles.