User Manual for ANLY models including: AH4CN-R Digital Timer, AH4CN-R, Digital Timer, Timer

AH5CN(M)W1.ai

jieyi

AH4CN-R AH5CN

12 avr. 2024 — User's Manual. SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product. WARNING. CAUTION. Warnings are indicated when ...

12 apr 2024 — User's Manual. SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product. WARNING. CAUTION. Warnings are indicated when ...


File Info : application/pdf, 1 Pages, 129.91KB

AH5CN Z1WA
AH4CN-R AH5CN
DIGITAL TIMER User's Manual
RESTRICTIONS ON USE
When using this product in applications that require particular safety or when using this product in important facilities, please pay attention to the safety of the overall system and equipment. Install failsafe mechanisms, perform redundancy checks and periodic inspections and adopt other appropriate safety measures when it is necessary. This product is rated at Class  .

SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product.

WARNING

Warnings are indicated when mishandling this product might result in death or serious injury to user.

CAUTION

Cautions are indicated when mishandling this product might result in minor injury to the user, or only physical damage to the timer.

WARNING

Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has been correctly wired before turning the power ON.
Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause electric shock.
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock. Do not disassemble the product. Doing so might cause electric shock or faulty operation.

CAUTION

Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
Make sure the product is firmly connected to the socket. Failure to do so might cause electric shock or fire.

Operating voltage Allowable operating voltage range Rated frequency Contact rating Reset time Power consumption Life Ambient temperature Ambient humidity Altitude Weight
2C, Mode A

SPECIFICATIONS

NAMES AND FUNCTIONS OF FACEPLATE

AC/DC(V): 12-48 or 100-240

85~110% of rated operating voltage 50 / 60 Hz 250VAC 5A (Resistive load) MAX 0.1S Approx. 2.5VA Mechanical : 5,000,000 times / Electrical : 100,000 times -10 ~ +50 (without condensation & freezing) MAX 85% RH (without condensation) MAX 2000m Approx. 130g

Contact Mode Switch A:for DPDT timelimiting output contacts B:for SPDT instantaneous and time-limiting output contacts
Memory Switch Set memory or not

Mode Memory

A

B off

on

Reset

AH5CN

hr

Display

CONNECTION

1A1C, Mode B

G Type

AH5CN-11

45

3

6

2

7

18

A

B

MODE

SOURCE

45

3

6

2

7

18

A

B

MODE

SOURCE

GATE RESET

45

3

6

2

7

18

SOURCE

GATE RESET

A

B

MODE

567

4

8

3

9

2

1

10 11

SOURCE

2C, Mode A

1A1C, Mode B

TIMING CHART
G Type

AH5CN-11

SOURCE (2-7) N.C. (8-5) N.O. (8-6) N.C. (1-4) N.O. (1-3) LAMP

Set Time Rt Set Time Rt:Reseting time

AH4CN-R/AH5CN

SOURCE (2-7) N.C. (8-5) N.O. (8-6) N.C. (1-4) N.O. (1-3) LAMP

Set Time Rt Set Time Rt:Reseting time

SOURCE (2-7) RESET (1-3) GATE (1-4)
SETTING VALUE
DISPLAY N.C. (8-5) N.O. (8-6)
LAMP

DIMENSION(mm)
AH4CN-R/AH5CN + Y-50 + US-08

SOURCE (2-10) RESET (6-7) GATE (6-5)
SETTING VALUE
DISPLAY (1-4)
N.C. (11-8) (1-3)
N.O. (11-9) LAMP

+0.5 -0

45

ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw

45

+0.5 -0

M-AH5CN-W-A
Printed in Taiwan



References

Acrobat Distiller 9.0.0 (Windows)