
User Manual for ANLY models including: AH4CN-R Digital Timer, AH4CN-R, Digital Timer, Timer
12 avr. 2024 — User's Manual. SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product. WARNING. CAUTION. Warnings are indicated when ...
12 apr 2024 — User's Manual. SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product. WARNING. CAUTION. Warnings are indicated when ...
File Info : application/pdf, 1 Pages, 129.91KB
DocumentDocumentAH4CN-R AH5CN DIGITAL TIMER User's Manual RESTRICTIONS ON USE When using this product in applications that require particular safety or when using this product in important facilities, please pay attention to the safety of the overall system and equipment. Install failsafe mechanisms, perform redundancy checks and periodic inspections and adopt other appropriate safety measures when it is necessary. This product is rated at Class . SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this product. WARNING Warnings are indicated when mishandling this product might result in death or serious injury to user. CAUTION Cautions are indicated when mishandling this product might result in minor injury to the user, or only physical damage to the timer. WARNING Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has been correctly wired before turning the power ON. Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause electric shock. Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock. Do not disassemble the product. Doing so might cause electric shock or faulty operation. CAUTION Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation. Make sure the product is firmly connected to the socket. Failure to do so might cause electric shock or fire. Operating voltage Allowable operating voltage range Rated frequency Contact rating Reset time Power consumption Life Ambient temperature Ambient humidity Altitude Weight 2C, Mode A SPECIFICATIONS NAMES AND FUNCTIONS OF FACEPLATE AC/DC(V): 12-48 or 100-240 85~110% of rated operating voltage 50 / 60 Hz 250VAC 5A (Resistive load) MAX 0.1S Approx. 2.5VA Mechanical : 5,000,000 times / Electrical : 100,000 times -10 ~ +50 (without condensation & freezing) MAX 85% RH (without condensation) MAX 2000m Approx. 130g Contact Mode Switch A:for DPDT timelimiting output contacts B:for SPDT instantaneous and time-limiting output contacts Memory Switch Set memory or not Mode Memory A B off on Reset AH5CN hr Display CONNECTION 1A1C, Mode B G Type AH5CN-11 45 3 6 2 7 18 A B MODE SOURCE 45 3 6 2 7 18 A B MODE SOURCE GATE RESET 45 3 6 2 7 18 SOURCE GATE RESET A B MODE 567 4 8 3 9 2 1 10 11 SOURCE 2C, Mode A 1A1C, Mode B TIMING CHART G Type AH5CN-11 SOURCE (2-7) N.C. (8-5) N.O. (8-6) N.C. (1-4) N.O. (1-3) LAMP Set Time Rt Set Time Rt:Reseting time AH4CN-R/AH5CN SOURCE (2-7) N.C. (8-5) N.O. (8-6) N.C. (1-4) N.O. (1-3) LAMP Set Time Rt Set Time Rt:Reseting time SOURCE (2-7) RESET (1-3) GATE (1-4) SETTING VALUE DISPLAY N.C. (8-5) N.O. (8-6) LAMP DIMENSION(mm) AH4CN-R/AH5CN + Y-50 + US-08 SOURCE (2-10) RESET (6-7) GATE (6-5) SETTING VALUE DISPLAY (1-4) N.C. (11-8) (1-3) N.O. (11-9) LAMP +0.5 -0 45 ANLY ELECTRONICS CO., LTD. http://www.anly.com.tw 45 +0.5 -0 M-AH5CN-W-A Printed in Taiwan