User Guide for Lutron models including: Switching Power Module, 369357h
369357h 4 03.03.20 Switching Power Module Power Modules SPECIFICATIN SUMITTAL Page ob Name: ob Number: Model Numbers: Lutron Mounting • •Mount in 2-gang U.S. wallbox 3.5 in (89 mm) deep or
File Info : application/pdf, 10 Pages, 801.23KB
DocumentDocumentLutron Switching Power Module Switching Power Module Description · Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. · May be used to switch incandescent, electronic lowvoltage, magnetic low-voltage, HID, fluorescent ballasts, and neon / cold cathode lighting sources. · Utilizes Softswitch arcless switching technology. · Provides power and switching for one zone. · Up to 3 power modules may be wired on a single GRAFIK Eye zone. · Model available for 120 V~ control power. · Model available for 120 277 V~ load power. Works with 120 V~ versions of: · Lutron 3-wire fluorescent dimmers (consult Lutron for Vierti products); see approved list in the dimmers & switches specification guide at www.lutron.com · GRAFIK Eye QS control units · GRAFIK Eye 3000 Series control units · LP, LCP, and GP dimming panels · HomeWorks and HomeWorks QS remote power panels · HomeWorks and HomeWorks QS neutral wire dimmers · RadioRA 2 neutral wire dimmers · Caséta Wireless neutral wire dimmers · Energi Savr Node LED+ phase adaptive fixture controller Models and Capacities Model Number Control Power PHPM-SW-DV-WH 120 V~ Load Power 120 277 V~ Capacity 16 A Power Modules 369357h 1 03.03.20 SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 1 Lutron Specifications Switching Power Module Power Modules 369357h 2 03.03.20 Regulatory Approvals · UL® listed · CSA certified · NOM certified · Complies with requirements for use in other spaces used for environmental air (plenums) per NEC® 2017 300.22(C)(3) Power · Control voltage: 120 V~ · Load voltage: 120 277 V~ · Capacity: Full 16 A 120 277 V~: 1920 4432 W · Frequency: 50 / 60 Hz, phase-to-neutral. · Load (output) power: Phase independent of control device / control voltage. Terminals · Accepts up to two 12 AWG (2.5 mm2) wires. Environment · 32 to 104 °F (0 to 40 °C). Relative humidity less than 90% non-condensing. · Indoor use only. · Maximum heat output of module: 15 BTU/hour. Mounting · Surface- or recess-mount. Sources / Load Types · Switches the following load types: Incandescent (tungsten) Halogen LED CFL Magnetic low-voltage transformer (iron core) Electronic (solid-state) low-voltage transformer Magnetic and electronic fluorescent dimming ballasts Neon/cold-cathode HID · Motors: 11/2 HP at 277 V~ 1/2 HP at 120 V~ · May be used with GFI / AFCI breaker protected loads. Key Design Features · Patented Softswitch technology. · Two LEDs on front of unit provide diagnostic information (visible when faceplate is removed). SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 2 Lutron Dimensions All dimensions shown as: in (mm) Switching Power Module 6.3 (160) 5.1 (129.5) Power Modules 369357h 3 03.03.20 1.2 (30.5) 1.0 (25) SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 3 Lutron Switching Power Module Power Modules Mounting · Mount in 2-gang U.S. wallbox 3.5 in (89 mm) deep or 4 in x 4 in (102 mm x 102 mm) junction box 2.1 in (53 mm) deep. · Indoor use only. · This device generates heat; mount only where ambient temperature is 32 °F to 104 °F (0 °C to 40 °C). · Mount with arrows facing up to ensure adequate cooling. 369357h 4 03.03.20 · Allow 4.5 in (114 mm) above and below unit and between faceplates when mounting several in a vertical layout. · Mount so line (mains) voltage wiring is at least 6 ft (1.8 m) from sound or electronic equipment and wiring. · Mount within 7° of true vertical. Mount to 2-gang U.S. wallbox Mount to 4 in x 4 in (102 mm x 102 mm), 2.1 in (53 mm) deep U.S. junction box Mount to 4 in x 4 in (102 mm x 102 mm), 2.1 in (53 mm) deep U.S. junction box with barrier (for 277 V~ model if required by local electrical code) Barrier SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 4 Lutron Wiring Switching Power Module Power Modules 369357h 5 03.03.20 · Pull 12 AWG (2.5 mm2) copper (Cu) wires [167 °F (75 °C) minimum] for input power and load circuit. · Strip 1/2 in (12 mm) insulation from wires before connecting. · Run separate neutral for load circuit - no common neutrals. · May be used with GFI breaker protected loads. Load circuit wiring (from GFI breaker to power module to load) must be run in its own non-metallic conduit, or nuisance tripping may occur. Maximum 100 ft (30.5 m) between power module and load. · May be used with AFCI breaker protected loads. An AFCI circuit can be loaded to the full allowable NECR rating for switched lighting. If combining dimmed and switched lighting on the same AFCI circuit, the amount of dimmed lighting should not exceed 1000 W, as this may trip the AFCI breaker. Single Power Feed Note: The power module may be on the same circuit as the control unit only if the total load does not exceed the rating of the breaker. Circuit breaker L/H 120 V~ N GRAFIK Eye QS 123456LN Wire to appropriate zone L/H N Load (Switched) SH 120 V~ Legend L /H Line / Hot N Neutral SH Switched Hot Ground Not Used SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Zone in Control Neutral Page 5 Lutron Switching Power Module Wiring Multiple Power Feeds The load breaker may be on a different phase than the control breaker. Power Modules 369357h 6 03.03.20 GRAFIK Eye QS 123456LN Wire to appropriate zone N 120 V~ L/H Control breaker Load breaker Load wiring L/H N Load (Switched) Legend L / H Line / Hot N Neutral SH Switched Hot Ground Not Used L/H N Zone in SH Control Neutral SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 6 Lutron Switching Power Module Power Modules Wiring Multiple Power Modules to a Single GRAFIK Eye Zone 369357h 7 03.03.20 Shown with separate feeds for control and loads. All breakers must be turned off prior to installing or servicing the modules. Up to 3 power modules may be wired to a single zone. GRAFIK Eye QS 123456LN Wire to appropriate zone Load breaker L/H L/H N N Load wiring1 Load SH for Power (Switched) Module #1 N 120 V~ L/H Control breaker Zone in Control Neutral Load wiring1 for Power Module #2 Load breaker L/H N Load (Switched) L/H N Zone in SH Control Neutral Load breaker L/H L/H N N Load wiring1 Load SH for Power (Switched) Module #3 1 Load feed: 120 277 V~ for PHPM-SW-DV-WH SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Zone in Control Neutral Page 7 Lutron Switching Power Module Power Modules Multi-location Wiring 369357h 8 03.03.20 Note: The power module may be on the same circuit/control zone as the control device only if the total load does not exceed the rating of the breaker (120 V~ only). Load wiring (see Note below) Circuit breaker L/H N Load (Switched) Legend L/H Line / Hot N Neutral SH Switched Hot DH Dimmed Hot Ground Not Used L/H N Zone in SH Control Neutral DH (yellow or orange wire) 3-wire fluorescent dimmer 120 V~ (main dimmer) SH (red wire) Cap off 3-wire fluorescent dimmer 120 V~ (accessory/ companion dimmer or 3-way switch) H/L 120 V~ N For specific wire colors, see the wallbox lighting controls catalog at www.lutron.com/wallbox catalog SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Page 8 Lutron Switching Power Module Power Modules Wiring a Power Module to an LP, LCP, GP, or HomeWorks Panel 369357h 9 03.03.20 Up to three power modules may be wired to an output of a 120 V~ LP or LCP panel. The load type for the output must be set as Eco-10 or Hi-lume fluorescent load type on the panel's circuit selector (for an LP or GP panel), controller (for an LCP panel), or HomeWorks software (for a HomeWorks panel). Wire to appropriate output L/H N Load wiring1 Load (Switched) Dimmed (1) 14 to 10 AWG Hot DH DH Zone In (2.0 to 4.0 mm2) DH L/H DH N H SH Control Neutral N N (1) 14 to 10 AWG N (2.0 to 4.0 mm2) Neutral N N 1 Load feed: 120 277 V~ if used with PHPM-SW-DV-WH power module )Lutron, Lutron, GRAFIK Eye, Softswitch, Vierti, HomeWorks, RadioRA, Eco-10, Caseta, and Hi-lume are trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries. RadioRA 2 is a trademark of Lutron Electronics Co., Inc. NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. 120 V~ Branch Circuit Breakers Neutral Lug Power (Line / Hot) (3) 14 to 2/0 AWG (2.0 to 70 mm2) SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: Neutral (1) 14 to 2/0 AWG (2.0 to 70 mm2) Page 9 Lutron Switching Power Module Power Modules 369357h 10 03.03.20 Wiring to an Energi Savr Node LED+ Phase Adaptive Fixture Controller Single or Multiple Power Modules to Single Power Panel · Control feed must be 120 V~ only. · Load feed must not exceed voltage rating of the load. · Up to three power modules may be wired to an output. CCI COM MUX MUX COM CCI 800 W 500 W 500 W 500 W Zn 1 Zn 2 Zn 3 Zn 4 Input Entrada Entrée Ta > 70 °C Opt 120 V~ Def 50 / 60 Hz 16 A 1 Prog 277 V~ 2 50 / 60 Hz 8.3 A 3 QSN-4A5-D H M L +1.844.LUTRON1 lutron.com LL NNNNN DL1 DL2 DL3 DL4 LL NN N N N Control Feed (120 V~) L/H N N Load breaker L/H N Load Wiring1 Lighting Loads 1 Load feed: 120 277 V~ if used with PHPM-SW-DV-WH power module L/ H N Zone In SH Control Neutral SPECIFICATION SUBMITTAL Job Name: Model Numbers: Job Number: DL1 DL2 DL3 DL4 Phase Adaptive Outputs DL Legend L/H Line / Hot N Neutral SH Switched Hot DH Dimmed Hot Ground Not Used Page 10