InfiRay ILR-1200-1 Bluetooth Laser Rangefinder
This document provides detailed information regarding the InfiRay ILR-1200-1 Bluetooth Laser Rangefinder, including its specifications, installation, operation, and regulatory compliance.
Product Description
The ILR-1200-1 Bluetooth Rangefinder is designed as an accessory for the TUBE series thermal imaging scopes. It allows users to accurately determine target distances, enabling precise shooting. The device features a compact, lightweight design with a visible red dot and movable red dot functions. It supports both single ranging and continuous ranging modes.
Specifications
Model | ILR-1200-1 |
---|---|
Type | Wireless Bluetooth Rangefinder |
Measuring Range, m | 10~1200 |
Accuracy, m | ±1, (10-100 m) ±(1 + L × 0.25%), (100 < L < 1200 m, L being the target distance) |
Laser Wavelength, nm | 900 ~ 908 (Eye-safe) |
Laser Pointer, nm | 650 |
Bluetooth | 5.0 |
Battery Parameters | One replaceable CR123 / 3.7V / 4h |
IP Rating | IP67 |
Dimensions, mm | 90 × 45 × 30 |
Weight, g | < 105 (w/o battery) |
* Measurement conditions for typical values: target size ≥1 m × 1 m, target reflectance ≥ 85%, outdoor visibility > 5 km
Components and Controls
The ILR-1200-1 consists of the following components:
- 1. Bluetooth laser rangefinder module: The main unit.
- 2. Laser indicator: Shows laser status.
- 3. Laser receive port: Receives laser signals.
- 4. Laser launch port: Emits the laser beam.
- 5. Quick release fixture: For mounting the rangefinder.
- 6. Battery compartment cover: Houses the battery.
- 7. Power button: For turning the device on/off.
- 8. LED indicator: Shows connection and power status.
Laser Warning Information:
[CAUTION] LASER 3R. P<5mW, 650nm. Complies with EN 60825-1:2014/A11:2021. [Laser Radiation Symbol] [Eye Protection Recommended Symbol]
Installation
Installation with Mate
The package includes:
- ILR-1200-1 Bluetooth Rangefinder
- Quick release fixture
- Insert ring for TUBE SE series
- L-shaped wrench
- User manual
Installation with Tube
- Use three inner hexagon screws to connect the bottom of the ILR-1200-1 Bluetooth rangefinder to one end of the fixture (5).
- Clamp the other end of the fixture, which is designed as a quick-release clamping ring, onto the TUBE series scope.
- The default inner diameter of the clamping ring is 30mm. If installed on the TUBE SE series, an insert ring (included in the package) is required.
Note: When the LRF is linked with TUBE, the stadiametric rangefinder function on TUBE series will not be available.
Operation and Usage
Battery Installation
- Rotate the battery compartment cover (4) counterclockwise.
- Place a CR123 3.7V battery into the compartment, ensuring the positive pole faces inward and the negative pole faces outward, as indicated by the label.
- Tighten the battery compartment cover (4) clockwise.
Safety Instructions
- Use the device within the recommended temperature range of -20°C to +50°C. Battery life may be impaired outside this range.
- Battery capacity may drop when the device is used below zero degrees Celsius; this is normal and does not indicate a defect.
- The device features low power shutdown protection: when the battery voltage is lower than 2.8V, the device will automatically shut down with a 30-second countdown prompt.
LED Indicator
The LED indicator shows the current connection and power status:
Indicator Color | Indicator Status | Device Status |
---|---|---|
Green Dot | Blinking | Automatically searching for a connection |
Keeping solid on for 3s after blinking and off | Successfully connected | |
Red Dot | Slow Blinking | Pairing failed |
Fast Blinking | Low power level | |
(No color specified) | Keeping solid on for 2s and off | The rangefinder is powered off successfully. |
Laser Calibration
After installation, if the laser's indicated position is inconsistent with the reticle center on the Tube, laser calibration is required:
- Select a common observation distance.
- Loosen the two screws (9) on the fixture (5) slightly.
- Ensure there is a spherical adapter ring (10) between the laser rangefinder and the fixture (5).
- Fine-tune the angle at the connection between the laser rangefinder and the fixture (5) until the position indicated by the laser is aligned with the reticle center of the Tube.
- Then tighten the two screws (9) to fix the angle.
Linkage and Usage with Tube
- Turn on the Bluetooth function on the Tube.
- Turn on the laser rangefinder by long-pressing the Power button (7) for 2 seconds.
- When the laser rangefinder module is on, it will automatically search and connect with the Tube series.
- Manual connection is also supported. On the Tube series, search and select the ID of the rangefinder, which can be found on the label affixed to the body or package of the rangefinder.
- When the LED indicator (8) on the rangefinder switches from blinking (green) to solid green for 3 seconds and then turns off, the connection is successful.
- Press the Power button (7) twice to turn the laser indicator (2) on or off.
- After use, long-press the Power button (7) to power off the rangefinder.
- For details about linkage and usage with Tube series, please refer to the user manual of the Tube.
Attention! Do not point the laser indicator directly to human eyes or faces.
Software Upgrade
The ILR-1200-1 Bluetooth laser rangefinder supports software upgrades. Users can download the upgrade program from the official website to their mobile device and upgrade it through the InfOutdoorBC APP.
- Download the upgrade program from the official website.
- Download and install the InfOutdoorBC APP on your mobile device from the APP Store.
- Turn on the Bluetooth of the mobile device.
- Long-press the Power button (7) to turn on the rangefinder.
- Open the InfOutdoorBC APP and tap the [Bluetooth Icon] in the APP to enter the search interface.
- Tap the [Search Icon] (Q) at the bottom to search for the Bluetooth signal.
- Select the name "Infiray-ILR-1200-1" and connect.
- When the connection is successful, an upgrade message is displayed automatically.
- Select "Yes" to enter the firmware upgrade interface, and tap the "Select File" option to find and select the upgrade program previously downloaded.
- Tap the "Start Upgrade" option. The percentage of the upgrade process will appear on the interface until the update is successful.
Upgrade Process Visuals:
Step 1: Initial screen showing scope view.
Step 2: Blank screen, likely preparing for connection.
Step 3: Connection screen showing "Connect" option.
Step 4: Upgrade confirmation screen for "Infiray-ILR-1200-1" with "Yes" and "No" options.
Step 5: Firmware upgrade interface showing file selection.
Step 6: Firmware upgrade interface with file details.
Step 7: Upgrade progress shown as "18.0%".
Legal and Regulatory Information
General
- Wireless transmitter module frequency range: WLAN: 2.412-2.472GHz (For EU).
- Wireless transmitter module power < 20dBm (only for EU).
EU Declaration of Conformity
[CE Mark] [UKCA Mark] IRay Technology Co., Ltd. declares that the Zoom V2 series thermal imaging monocular complies with directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity and additional information are available at: www.infirayoutdoor.com.
This device may be operated in all member states of the EU.
User Information on Disposal (WEEE Directive)
2012/19/EU (WEEE directive): Products marked with the [WEEE Disposal Symbol] cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information, see: www.recyclethis.info.
Regulatory Information USA
- FCC ID: 2AYGT-40-ILR
- Labeling requirements: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
- The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
Body-worn Operation
This device was tested for typical body-support operations. To comply with RF exposure requirements, a minimum separation distance of 0.5cm must be maintained between the user's body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.
Contact Information
IRay Technology Co., Ltd.
Add.: 11th Guiyang Street, YEDA, Yantai, P.R. China
Tel: 0086-400-999-3800
Email: infirayoutdoor@infiray.com
[CE Mark] [UKCA Mark] [RoHS Compliant]