Instruction Manual for BANNER models including: LCA130T5KQ, LCA130T, LCA130T Andon Control Box, LCA130T, Andon Control Box, Control Box, Box
LCA130T5KQ | LCA130T Andon Control Box
Jun 4, 2024 · Rugged, cost-effective, and easy-to-install Andon Control Box. Integral three, four, or five capacitive touch button controller with ...
File Info : application/pdf, 13 Pages, 3.74MB
DocumentDocumentLCA130T Andon Control Box with IO-Link Instruction Manual Original Instructions p/n: 241973 Rev. A June 04, 2024 © Banner Engineering Corp. All rights reserved. Contents Chapter 1 Features Models ........................................................................................................................................................................................................... 3 Chapter 2 LCA130T Switch Diagram ..................................................................................... 4 Chapter 3 IO-Link Process Data Out (Master to Device) ..................................................... 5 Chapter 4 Specifications FCC Part 15 Class B for Unintentional Radiators.......................................................................................................................................... 7 Industry Canada ICES-003(B)....................................................................................................................................................................... 8 Dimensions .................................................................................................................................................................................................... 8 Chapter 5 Accessories Cordsets ........................................................................................................................................................................................................ 9 Power Supplies............................................................................................................................................................................................ 10 IO-Link Masters ........................................................................................................................................................................................... 10 Chapter 6 Banner Engineering Corp Limited Warranty..................................................... 12 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents Models.................................................................................................................................................................................................................. 3 Chapter 1 Features · Rugged, cost-effective, and easy-to-install Andon Control Box · Integral three, four, or five capacitive touch button controller with programmable LEDs and discrete outputs · IO-Link gives full access to color, flashing, and dimming settings, as well as advanced animations which provide dynamic response to changing machine conditions · Two M12 connectors for added Andon application flexibility and easy installation · Three to five discrete outputs available to pass up to a total of 4 amps Models Model Name Activation Method Number of Touch Buttons LCA130T3KQ 3 Buttons LCA130T4KQ Touch 4 Buttons LCA130T5KQ 5 Buttons Control IO-Link Connectors Input: Integral 4-pin M12 male quickdisconnect connector Output: Integral 5-pin M12 female quick-disconnect connector Input: Integral 4-pin M12 male quickdisconnect connector Output: Integral 5-pin M12 female quick-disconnect connector Input: Integral 4-pin M12 male quickdisconnect connector Output: Integral 8-pin M12 female quick-disconnect connector June 04, 2024 © Banner Engineering Corp. All rights reserved. page 3 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents Chapter 2 LCA130T Switch Diagram Touch, or touch and hold, one or more of the buttons to activate a programmed color and animation function. Input Pinout - All Models 4-pin M12 Male Connector 1 2 4 3 Pin Wire Color Wiring Description 1 Brown (bn) 18 V DC to 30 V DC 2 White (wh) Not used 3 Blue (bu) DC common (GND) 4 Black (bk) IO-Link Communication Output Pinout Switch Control Button Diagrams 5-Button LCA130T Button 5 Button 4 Button 3 Button 2 Button 1 Connectors 8-pin M12 Female Connector 2 3 1 4 7 6 5 8 Pinout Keys Pin 1 = Button 3 Pin 2 = Button 4 Pin 3 = Not used Pin 4 = Button 1 Pin 5 = Button 2 Pin 6 = Button 5 Pin 7 = DC common (GND) Pin 8 = Not used 4-Button LCA130T Button 4 Button 3 Button 2 Button 1 5-pin M12 Female Connector 2 1 3 4 5 Pin 1 = Button 2 Pin 2 = Button 3 Pin 3 = DC common (GND) Pin 4 = Button 1 Pin 5 = Button 4 3-Button LCA130T Button 3 Button 2 Button 1 5-pin M12 Female Connector 2 1 3 4 5 Pin 1 = Button 2 Pin 2 = Button 3 Pin 3 = DC common (GND) Pin 4 = Button 1 Pin 5 = Not used June 04, 2024 © Banner Engineering Corp. All rights reserved. page 4 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents Chapter 3 IO-Link Process Data Out (Master to Device) IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.io-link.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. State Mode Use Process Data In to read button output states of Off, On, or Hold. Use Process Data Out to set button output states to No Override, Off, On, or Hold. Use Parameter data to change touch button sensitivity, logic, color, intensity, flash speed, and select animation type on Off, On, and Hold output states. Name Description Animation Type Off Button LED is off Steady Color 1 is solid on at defined intensity Flash Color 1 flashes at defined speed, color intensity, and pattern Two Color Flash Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity Color Sweep Color 1 and Color 2 transition alternately at defined speed and color intensities Animation Pattern Defines the flash pattern for flash and two color flash animations (normal, strobe, three pulse, SOS, or random) Animation Speed Defines the animation speed (slow, medium, fast, or custom) Off Delay Type Defines if the Off Delay should be measured from when the conditions for the State began (Leading Edge) or from when the conditions ended (Trailing Edge) Off Delay (ms) The duration of the animation Off Delay. Leading Edge Off Delays can be used to ensure the animation is active for at least a minimum amount of time. Color 1 Defines Color 1 of defined animation Color 1 Intensity Defines the intensity of Color 1 in the animation (high, medium, low, off, or custom) Color 2 Defines Color 2 of defined animation Color 2 Intensity Defines the intensity of Color 2 in the animation (high, medium, low, off, or custom) Touch Sensitivity Defines the sensitivity of the touch button as either Standard, High or Low. Low sensitivity resists false activation. High sensitivity can be used for improved touch response Function Latching or Momentary options. Momentary function toggles output on only during a touch button input. Latching function toggles output on or off for each touch button input Hold Defines if Hold state is Enabled or Disabled June 04, 2024 © Banner Engineering Corp. All rights reserved. page 5 LCA130T Andon Control Box with IO-Link Instruction Manual IO-Link Process Data Out (Master to Device) Advanced Mode Use Process Data In to read button output states of True or False. Use Process Data Out to set touch button logic, color, intensity, flash speed, and select animation type. Name Description Animation Type Off Button LED is off Steady Color 1 is solid on at defined intensity Flash Color 1 flashes at defined speed, color intensity, and pattern Two Color Flash Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity Color Sweep Color 1 and Color 2 transition alternately at defined speed and color intensities Output Sets button output to On, Off, or Pattern Animation Pattern Defines the flash pattern for flash and two color flash animations (normal, strobe, three pulse, SOS, or random) Animation Speed Defines the animation speed (slow, medium, fast, or custom) Color 1 Defines Color 1 of defined animation Color 1 Intensity Defines the intensity of Color 1 in the animation (high, medium, low, off, or custom) Color 2 Defines Color 2 of defined animation Color 2 Intensity Defines the intensity of Color 2 in the animation (high, medium, low, off, or custom) page 6 © Banner Engineering Corp. All rights reserved. June 04, 2024 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents FCC Part 15 Class B for Unintentional Radiators ................................................................................................................................................ 7 Industry Canada ICES-003(B).............................................................................................................................................................................. 8 Dimensions........................................................................................................................................................................................................... 8 Chapter 4 Specifications Supply Voltage and Current 18 V DC to 30 V DC 50 mA maximum current at 18 V DC (exclusive of load) Supply Protection Circuitry Protected against transient voltages Response Time Power-Up Delay: 500 milliseconds maximum Input Response: 40 milliseconds maximum Output Response: 300 milliseconds maximum IO-Link Interface Supports Smart Sensor Profile: No Baud Rate: 38400 bps (COM2) Process Data In: 16 bits (2 bytes) Process Data Out: 160 bits (20 bytes) IODD Files: Provides all programming options, plus additional functionality Output Rating 4A maximum load (combined or on a single output) Connections Inputs: Integral 4-pin M12 male quick-disconnect connector Outputs: Integral 5-pin or 8-pin M12 female quick-disconnect connector, depending on model Models with a quick disconnect require a mating cordset Construction Polycarbonate Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Operating Conditions 40 °C to +50 °C (40 °F to +122 °F) 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating IP65 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) 20 22 24 Required Overcurrent Protection (A) 5.0 3.0 1.0 Supply Wiring (AWG) 26 28 30 Required Overcurrent Protection (A) 1.0 0.8 0.5 Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. June 04, 2024 © Banner Engineering Corp. All rights reserved. page 7 LCA130T Andon Control Box with IO-Link Instruction Manual Specifications Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. 35.5 [1.4] 50.8 [2.0] M12 x 1.0 4X 7.1 [0.28] 49.9 [1.96] 2X 1/4 - 20 PEM Insert 148.1 [5.83] 140.8 [5.54] 148.1 [5.83] M12 x 1.0 55.9 [2.2] 9.0 [0.35] page 8 © Banner Engineering Corp. All rights reserved. June 04, 2024 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents Cordsets ............................................................................................................................................................................................................... 9 Power Supplies .................................................................................................................................................................................................. 10 IO-Link Masters .................................................................................................................................................................................................. 10 Chapter 5 Accessories Cordsets Model MQDC-403 MQDC-406 MQDC-410 MQDC-415 MQDC-430 MQDC-450 MQDC-460 MQDC-470 MQDC-4100 4-Pin Threaded M12 Cordsets--Single Ended Length Style Dimensions 1 m (3.28 ft) 2 m (6.56 ft) 44 Typ. 3 m (9.8 ft) 5 m (16.4 ft) 9 m (29.5 ft) 15 m (49.2 ft) Straight M12 x 1 1 ø 14.5 Ø5.2 mm 4 18.3 m (60 ft) 21 m (68.9 ft) 58 mm 7 mm 30 m (98.43 ft) Pinout (Female) 2 1 = Brown 3 2 = White 3 = Blue 5 4 = Black 5 = Not used Model MQDEC-501SS MQDEC-503SS MQDEC-506SS MQDEC-512SS MQDEC-515SS MQDEC-530SS MQDEC-550SS Length 0.31 m (1.02 ft) 5-Pin Threaded M12 Cordsets--Double Ended Style Dimensions Pinout (Male) 1 2 4 3 5 0.91 m (2.99 ft) 1.83 m (6 ft) 3.66 m (12 ft) Male Straight/ Female Straight 5 m (16.4 ft) 9 m (29.5 ft) 15 m (49.2 ft) 40 Typ. M12 x 1 ø 14.5 44 Typ. M12 x 1 ø 14.5 1 = Brown 2 = White 3 = Blue Pinout (Female) 2 1 3 4 5 4 = Black 5 = Gray June 04, 2024 © Banner Engineering Corp. All rights reserved. page 9 LCA130T Andon Control Box with IO-Link Instruction Manual Model MQDEC1-803SS MQDEC1-806SS MQDEC1-810SS MQDEC1-815SS MQDEC1-830SS MQDEC1-850SS MQDEC1-8100SS MQDEC1-8200SS Length 1 m (3.28 ft) 2 m (6.56 ft) 3 m (9.84 ft) 5 m (16.4 ft) 8-Pin Threaded M12 Cordsets--Double Ended Style Dimensions 40 Typ. Male Straight / Female Straight M12 x 1 ø 14.5 44 Typ. M12 x 1 ø 14.5 9 m (29.5 ft) 15 m (49.2 ft) 30.5 m (100 ft) 61 m (200 ft) Female 2 3 1 4 7 6 5 8 Male 1 7 2 6 3 4 5 8 CSB-M1251FM1251M · 5-pin parallel Y splitter (Male-Male-Female) · For full Pro Editor preview capability · Requires external power supply, sold separately Accessories Pinout 1 = White 2 = Brown 3 = Green 4 = Yellow 5 = Gray 6 = Pink 7 = Blue 8 = Red Power Supplies PSW-24-1 · 24 V DC, 1 A Class 2 UL Listed power supply · 100 V AC to 240 V AC 50/60 Hz input · 2 m (6.5 ft) PVC cable with M12 quick disconnect · Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs PSW-24-2 · 24 V DC, 2 A Class 2 UL Listed power supply · 100 V AC to 240 V AC 50/60 Hz input · 3.5 m (11.5 ft) PVC cable with M12 quick disconnect · Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs TYPE A TYPE G TYPE C TYPE I IO-Link Masters DXMR90-4K Series Controller IO-Link Master · One female M12 D-Code Ethernet connector · Four female M12 connections for IO-Link master connections · One male M12 (Port 0) connection for incoming power and Modbus RS-485, one female M12 connection for daisy chaining Port 0 signals page 10 © Banner Engineering Corp. All rights reserved. June 04, 2024 Accessories LCA130T Andon Control Box with IO-Link Instruction Manual DXMR110-8K Series Controller IO-Link Master · Two female M12 D-Code Ethernet connectors for daisy chaining and communication to a higher-level control system · Eight female M12 connections for IO-Link master connections · One male M12 connection for incoming power, one female M12 connection for daisy chaining power 8 7 2 6 5 1 4 3 2 1 June 04, 2024 © Banner Engineering Corp. All rights reserved. page 11 LCA130T Andon Control Box With IO-Link Instruction Manual Chapter Contents Chapter 6 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. June 04, 2024 © Banner Engineering Corp. All rights reserved. page 12 LinkedIn Twitter Facebook © 2024. All rights reserved. www.bannerengineering.com