User Manual for INKBIRD models including: IAQM-129-W, 2AYZD-IAQM-129-W, IAQM-129-W Indoor Air Quality Monitor, Indoor Air Quality Monitor, Air Quality Monitor, Quality Monitor, Monitor

80x120mm

UM

Shenzhen Inkbird Technology Co., Ltd. IAQM-129-W Air Quality Monitor 2AYZD-IAQM-129-W 2AYZDIAQM129W iaqm 129 w

download (pdf)

IAQM-129-W Air Quality Monitor by Shenzhen Inkbird


File Info : application/pdf, 1 Pages, 681.13KB

PDF preview unavailable. Download the PDF instead.

IAQM-129-W-Users-Manual-Shenzhen-Inkbird-2ayzd-iaqm-129-w-ex-1-10
80mm x 120mm 2024.04.01

INKBIRD INDOOR AIR QUALITY MONITOR
IAQM-129-W

USER

MANUAL
01

Please keep this manual properly for reference. You can also scan the QR code to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support @inkbird.com.
02

04 OPERATION INSTRUCTIONS
4.1 Power On/Off
Press and hold the ECO button for 2 seconds to turn the device on or off.
4.2 Set Time & Date
Step 1: Press the button twice quickly to enter the time setting, the month number will flash.
Step 2: Press the or button to increase or decrease the number, then press the SET button to confirm.
Step 3: The day number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
Step 4: The hour number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
Step 5: The minute number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
4.3 Set AQI / CO2 / PM2.5 Alarm Values and CO2 Auto Calibration
Step 1: Press the SET button twice quickly to enter the alarm setting, the AQI alarm value will flash.
Step 2: Press the or button to increase or decrease the number and press the SET button to confirm.
Step 3: After setting the AQI alarm value, the CO2 alarm value will flash. Press the or button to increase or decrease the number and press the SET button to confirm.
Step 4: After setting the CO2 alarm value, it will enter the setting of CO2 auto-calibration. The character C-OF (CO2 calibration off) or C-ON (CO2 calibration on) will flash. Press the or button to switch the CO2 auto-calibration function on or off, then press the SET button to confirm.
07

Please note that the ON or OF character will pause for 2 seconds during setting, this is a normal phenomenon. Please be patient and wait for it to flash. Step 5: The PM2.5 alarm value will flash. Press the or button to
increase or decrease the number and press the SET button to confirm.
4.4 WiFi Function On/Off
Press and hold the button for 2 seconds to turn on the WiFi function. Press the button twice quickly to turn off the WiFi function. When the WiFi function is on, press and hold the button for 2 seconds to reset the WiFi connection.
4.5 ECO Mode (when the ECO light is on)
1. After operating the device, the sensor will detect in real time within 5 minutes;
2. After 5 minutes of inactivity, the sensor will detect once every 15 minutes;
3. After 1 hour of inactivity, the sensor will detect once every 1 hour; 4. If any operation or out-of-range data has occurred, the sensor will
revert to state 1.When the ECO mode is off (the ECO light is off), the sensor detects data in real time. Note: If there is no operation for 30 seconds, the unit will automatically
save the setting and exit.
05 APP INSTALLATION & CONNECTION
5.1 Search the INKBIRD App from Google Play or App Store to get it for free, or you can scan the QR code below to download it directly.
08

01 TECHNICAL SPECIFICATIONS

Product Name Model Number
Data Detection
Screen Size Built-in Li-Po Battery Power Input WiFi Connection Supporting
Package Contents

Indoor Air Quality Monitor IAQM-129-W Carbon Dioxide, Temperature, Humidity, AQI, HCHO, PM2.5, TVOC, PM10
14.1*6cm 2700mAh DC5V~12V 2.4GHz WiFi+Bluetooth
1x Air Quality Monitor; 1x USB cable; 1x User Manual

02 PRODUCT INTRODUCTION Product Appearance
Charging Port

AQI Alarm Light : Green light : 0~50 Yellow light : 51~100 Red light : 101~500
03

Hang Holes
Screen Information Description

CO2 Comfort Level Indicator: Green : 400~1000ppm Yellow : 1001~1400ppm Red : 1401~5000ppm

PM2.5 Comfort Level Indicator: Green : 0~35g/m³ Yellow : 36~75g/m³ Red : 76~1000g/m³

04

ICON

DESCRIPTION

MEASUREMENT RANGE

TEMP HUMI CO2 AQI

Temperature Humidity
Carbon Dioxide Air Quality Index

-10°C ~ 40°C (±1.5) / 14~104 (±2.7) 20 ~ 80 %RH (±5 %RH) 400 ~ 5000 ppm [±(50ppm + 5%)] 0~500

HCHO

Formaldehyde

0 ~ 2.000 mg/m³ (±15%)

PM2.5

Particulate Matter 2.5

0 ~ 999 g/m³ (±10%)

TVOC Total Volatile Organic Compounds 0~ 5.00 mg/m³ (±15%)

PM10

Particulate Matter 10

0 ~ 999 g/m³ (±10%)

AQI Comfort Level Emoticon

0~50: (comfortable) + green light 51~100: (medium) + yellow light 101~500: (uncomfortable) + red light

Battery Level WiFi Connection

Shows the remaining battery power in real time
Stays on when WiFi is connected; flashes when WiFi is requesting a connection.

Audible Alarm

On/Off switchable

ECO

ECO Mode

On/Off switchable

Backlight

Screen Backlight

Switchable between 100% and 5% brightness

03 OPERATION BUTTON DEFINITIONS

ECO Light
05

BUTTONS

DESCRIPTION  Press once to turn the ECO mode on or off. When ECO mode is on,
both the backlight and alarm light are turned off.  Press and hold for 2 seconds to turn the device on or off.

 Press once to change the backlight brightness to its 100% or 5%.  Press and hold for 2 seconds to turn on the WiFi function.  Press twice quickly to turn off the WiFi function.

 Press once to switch the temperature unit between Celsius and Fahrenheit. (The default setting is .)
 Press twice quickly to enter the setting of AQI/CO2/PM2.5 alarm values and CO2 auto calibration function.
 Press and hold for 2 seconds to turn the AQI alarm light on or off.
 Press twice quickly to enter the time and date setting.  Press once to switch between 12-hour and 24-hour format time
display.  Press and hold for 2 seconds to turn the audible alarm on or off.

Note: When the device is powered off, place it in a well-ventilated place, then press and hold both the ECO and SET buttons simultan -eously, the device will enter the CO2 calibration mode, which takes 200 seconds. During the CO2 calibration, please make sure that no one comes near the device to affect the calibration result.

06

NOTE 1. Your iOS devices must be running iOS 12.0 or above to download the
app smoothly. 2. Your android devices must be running android 7.1 or above to download
the app smoothly. 3. The device supports a 2.4GHz Wi-Fi router only. 4. APP Location Permission Requirement: We need to obtain your location
information to discover and add nearby devices. INKBIRD promises to keep your location information strictly confidential. And your location information will only be used for the location function of the App and will not be collected, used, or disclosed to any third party. Your privacy is very important to us. We will abide by relevant laws and regulations and take reasonable security measures to protect your information security.
5.2 Registration
Step 1: Registering an account is necessary before using the INKBIRD app for the first time.
Step 2: Open the app, select your Country/Region, and a verification code will be sent to you.
Step 3: Enter the verification code to confirm your identity, and the registration is complete.
5.3 How To Connect
Step 1: Turn on both the Bluetooth and WiFi functions on your smartphone.
Step 2: Open the INKBIRD app and click "+" on the top right corner to add the device. Then, follow the app instructions to complete the connection.
09

Note: 1. Make sure that the device is placed as close to the smartphone and
router as possible during the connection process. 2. All data exported from the application can only be in Celsius.
06 FCC REQUIREMENT
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
­ Reorient or relocate the receiving antenna. ­ Increase the separation between the equipment and receiver. ­ Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. ­ Consult the dealer or an experienced radio/TV technician for help.
10

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
07 CUSTOMER SERVICE
This item carries a 1-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge. For any problems in use, please feel free to contact us at support@inkbird. com. We will do our best to help you.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the intReerfoerrienct eorbryeolonceatoer tmhoerreecoefitvhinegfoalnlotweninnga.measures:
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to whCicohnstuhlet rtehceediveearleisr coornanneecxtepde.rienced radio/TV technician for help.

ISED Statement: This device complies with Part 15 of FCC Rules [ and contains license-exempt transmitter(s) that comply with innovation Science and Economic Development Canada's licence-exempt RSS Standar(s)]. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference received, including interference that may cause undesired operation The digital apparatus complies with Canadian CAN ICES 3 (B)/NMB 3(B). This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. French: L'émetteur/récepteurexempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et DéveloppementéconomiqueCanada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. l'appareil numérique du ciem conforme canadien peut 3 (b) / nmb 3 (b). cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du cnr - 10 et conformité avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des données canadiennes sur l'exposition aux champs rf et la conformité.