Installation Guide for GEOTAB models including: 6100 GEN5 Control System, 6100 GEN5, Control System, System

Force America 6100 GEN5 IOX-WRKS

Shane

Force America 6100 GEN5

IOX-WRKS: Winter Solution Install Guide

PDF preview unavailable. Download the PDF instead.

Force America 6100 GEN5 IOX-WRKS [PUB]
Field Services Installer Documentation: Force America 6100 GEN5 + IOX-WRKS
FA6100 to IOX-WRKS Primary port requires a standard straight through cable
HRN-FAI

IOX-WRKS

FA 6100 DB9 to IOX-WRKS primary port

Note: Early model (GEN 4 and lower) Force America 6100's require an ELA module. Refer to the GEN3-4 document for integration instructions for thise models.
Notice: Always use winter input mapping for telemetries AUX5- Belly Plow or Manual Spreader, AUX6- Front Plow, AUX7- Wing Plow, AUX8- Tow Plow or Beacon
Force America 6100 configuration settings
1. Once logged into the Calibration area of the 6100 Navigate to Calibration/Configuration/ Enable Options A password may be required to enter this area - Set "Event logging serial" to "Enabled". - Set "Event logging (OTA)" to "Disabled". - Set "SIM Speed" to "Enabled".
Navigate to Calibration/Event logging/ Intervals - Set each parameter to "Enabled".
Navigate to Calibration/ System Management/ Shutdown - select "Restart now" to reboot system.
On Reboot and from the operator screen - Set SIM speed ~ 25 MPH / KPH - toggle (green dial) from Standby to Operations - Verify integration
On completion - ensure SIM speed is returned to disabled if you enabled this feature.

ª
ªªªªª
ªª ª

Interval based triggers can be changed to modify reporting frequency

