Installation Guide for Danfoss models including: Pack Controller AK-PC 782B with USB-B

Pack Controller, type AK-PC 782B with USB-B

Pack Controller, type AK-PC 782B with USB-B - Danfoss

2023-03-27 — 1 (AI 1). 1 - 2. 2 (AI 2). 3 - 4. 3 (AI 3). 5 - 6. 4 (AI 4). 7 - 8. 5 (AI 5). 9 - 10. 6 (AI 6). 11 - 12. 7 (AI 7). 13 - 14. 8 (AI 8). 19 - 20. 9 (AI 9).

PDF preview unavailable. Download the PDF instead.

AN412826307589en-000101
Installation Guide
Pack Controller, type AK-PC 782B with USB-B

080R9351 AN412826307589en-000101

Danfoss 80Z942

080Z0202

-20 °C < tamb < 55 °C -0 °F < tamb < 130 °F 0 ­ 95% RH, non condensing IP10 / VBG4 UL: E31024

Warning
Ensure power is disconnected before adding or removing modules.

AI x 11 DO x 8
Supply voltage:
Transformer Class II

Danfoss 80Z941

AI A,B,C,D 24 V AC/DC

12 V 5 V

AI 5 V
Max. 10 V

The 24 V must not be shared by other controllers or units
The 24 V input must not have earth connection
24 V
OK
24 V

Max. 230 V

LAN* Not used IO Extension
*Shielded twisted pair CAT5

For the LAN with IP communication, the address must be set between 011 ­ 199.

ON/OFF

ON/OFF

Keep the safety distance. Low and high voltage must not be connected to the same output group.

SPDT

Umin : 48 V AC I max.: 0.5 A

SPDT: AC-1: 4A (ohmic) AC-15: 3A (Inductive)

Danfoss 80Z206

© Danfoss | Climate Solutions | 2022.06

AN412826307589en-000101 | 1

Point

Terminal 15: 12 V Terminal 16: 5 V Terminal 27: 12 V Terminal 28: 5 V Terminal 17, 18, 29, 30:

Relay or AKV coil 110/230 V

S (sensor) Pt 1000 ohm/0°C
P (pressure) AKS 32R
AKS 32

Signal

Signal type

S1 S2... Saux1 Saux2 SSA SdA

Pt 1000

AKS 32R

P0A P0B PcA

AKS 2050 MBS 8250 -1 - xx bar

PcB

AKS 32

-1 - zz bar

U (voltage) On/Off DO

AKV

0 - 5 V

...

0 - 10 V

Ext. Main switch Day/ Night Door Comp 1 Comp 2 Fan 1 Alarm

Active at: Closed / Open
Active at: ON / OFF

AO

AO

0-10 V

The Product contains electrical components And may not be disposed together with domestic waste. Equipment must be separate collected with Electrical and Electronic waste. According to Local and currently valid legislation.

2 | AN412826307589en-000101

Address

011 ­ 199 e.g. 012

Signal

(Controller)

Signal type / Active at

Module Point Terminals

1 (AI 1)

1 - 2

2 (AI 2)

3 - 4

3 (AI 3)

5 - 6

4 (AI 4)

7 - 8

5 (AI 5)

9 - 10

6 (AI 6) 11 - 12

7 (AI 7) 13 - 14

8 (AI 8) 19 - 20

9 (AI 9) 21 - 22

10 (AI 10) 23 - 24

1

11 (AI 11) 25 - 26

12 (DO 1) 31 - 32

13 (DO 2) 33 - 34

14 (DO 3) 35 - 36

15 (DO 4) 37 - 38

16 (DO 5) 39 - 41

17 (DO6) 42 - 44

18 (DO7) 45 - 47

19 (DO8) 24 (AO1) 25 (AO2)

48 - 50 -