Vortice VORT HR W-ALL 100 DF Dual-Flow Heat Recovery Units

Introduction

The VORT HR W-ALL 100 DF series by Vortice offers decentralized dual-flow heat recovery units designed to ensure optimal air exchange in homes, residential buildings, commercial premises, firms, offices, and hotel rooms. These units are engineered for efficiency, comfort, and ease of installation.

Key features include:

Benefits for the User

Benefits for the Installer

Models and Technical Features

The VORT HR W-ALL 100 DF series is available in three versions:

Passive House certified versions are also planned.

Design Features:

Regulatory Standards Compliance:

The products comply with European Norms, Directives, and Regulations including:

Patent pending. Vortice is a member of AMCA (Air Movement & Control Association).

Dimensions

Detailed dimensions are provided for each model:

VORT HR W-ALL 100 DF W Cod. 12484 (Wall-Mounted Version)

Model A (mm) B (mm) C (mm) D (mm) ØE (mm) F (mm) G (mm)
VORT HR W-ALL 100 DF W 605 385 250 72 97 358 573

VORT HR W-ALL 100 DF SR Cod. 12485 (Semi-Recessed Version)

Model A (mm) B (mm) C (mm) D (mm) ØE (mm) F (mm) G (mm) ØH (mm) ØI (mm)
VORT HR W-ALL 100 DF SR 605 385 250 72 584 664 366 97 96

VORT HR W-ALL 100 DF R Cod. 12486 (Recessed Version)

Model A (mm) B (mm) C (mm) D (mm) ØE (mm) ØF (mm)
VORT HR W-ALL 100 DF R 595 393 217 675 97 96

Technical Data

Detailed technical data including voltage, speed, phase, IP rating, motor class, power, temperature range, and weight are provided for each model:

VORT HR W-ALL 100 DF W Cod. 12484

V~50-60 HZ SPEED NUMBER PHASE NUMBER IP MOTOR CLASS W (V1/V2/V3/V4/V5) °C MIN/MAX KG
220-240 5 1 22 B 8/11/16/31/48 -5/40 17
FLOW RATE IN m³/h BOOST HIGH PERFORMANCE PERFORMANCE QUIET SUPER QUIET
Pa 90 75 50 35 15
314 215 105 58 24

VORT HR W-ALL 100 DF SR Cod. 12485

V~50-60 HZ SPEED NUMBER PHASE NUMBER IP MOTOR CLASS W (V1/V2/V3/V4/V5) °C MIN/MAX KG
220-240 5 1 22 B 8/11/16/31/48 -5/40 17.6
FLOW RATE IN m³/h BOOST HIGH PERFORMANCE PERFORMANCE QUIET SUPER QUIET
Pa 90 75 50 35 15
314 215 105 58 24

VORT HR W-ALL 100 DF R Cod. 12486

V~50-60 HZ SPEED NUMBER PHASE NUMBER IP MOTOR CLASS W (V1/V2/V3/V4/V5) °C MIN/MAX KG
220-240 5 1 22 B 8/12/19/39/58 -5/40 17.6
FLOW RATE IN m³/h BOOST HIGH PERFORMANCE PERFORMANCE QUIET SUPER QUIET
Pa 130 110 70 53 31
296 220 104 59 26

* The company reserves the right to modify the above data without prior notice and whenever necessary.

Sound Pressure Levels (LpA) at 1m and 3m:

Speed VORT HR W-ALL 100 DF W Cod. 12484 VORT HR W-ALL 100 DF SR Cod. 12485 VORT HR W-ALL 100 DF R Cod. 12486
Lwa dB(A) Lp 1m dB(A) Lp 3m dB(A) Lwa dB(A) Lp 1m dB(A) Lp 3m dB(A) Lwa dB(A) Lp 1m dB(A) Lp 3m dB(A)
Super Quiet 24 16 < 10 22 14 < 10 24 16 < 10
Quiet 36 28 19 33 25 16 31 23 14
Performance 43 35 26 41 33 24 36 28 19
High Performance 52 44 35 51 43 34 45 37 28
Boost 57 49 40 56 48 39 50 42 33

* Sound pressure values calculated for hemispherical free field propagation at a distance of 1 m and 3 m from the unit.

Curves

Performance curves illustrating the relationship between airflow rate (q), static pressure (Pa), and power consumption (W) are provided for the wall-mounted and semi-recessed versions. These curves help in selecting the optimal operating point.

Diagram showing performance curves for VORT HR W-ALL 100 DF W Cod. 12484 (Wall Installation). The graph plots static pressure and power against airflow rate for different operating modes (Boost, High Performance, Performance, Quiet, Super Quiet).
Diagram showing performance curves for VORT HR W-ALL 100 DF SR Cod. 12485 (Semi-Recessed Installation). Similar to the wall-mounted version, this graph illustrates performance across various modes.

For the semi-recessed installation (code 12472), the air flow rate extracted from a second room depends on the ducting system's pressure losses. An example is given for a specific ducting configuration.

For the recessed version, the total extracted and introduced flow rate can be inferred from the provided diagram.

Flow Rate Settings:

SET POINT "Other room" spigot intake flow rate by configuration (code 12472) m³/h
SUPER QUIET 8
QUIET 18
PERFORMANCE 25
HIGH PERFORMANCE 41
BOOST 45
Diagram showing performance curves for VORT HR W-ALL 100 DF R Cod. 12486 (Recessed Installation). This graph details static pressure and power against airflow rate for different operational modes. A key explains the color coding for pressure and power in each mode.

Applications and Installation Examples

The VORT HR W-ALL 100 DF units are suitable for various installation types:

Illustration of a wall installation for the VORT HR W-ALL 100 DF W Cod. 12484 unit, showing the unit and necessary duct components.
Illustration of a semi-recessed installation without extraction from another room for the VORT HR W-ALL 100 DF SR Cod. 12485 unit, showing the unit and duct components.
Illustration of a semi-recessed installation with extraction from another room for the VORT HR W-ALL 100 DF SR Cod. 12485 unit, depicting the unit, ducting, and its placement within a wall.
Illustration of a recessed installation for ventilating multiple rooms, with ducts in a false ceiling, for the VORT HR W-ALL 100 DF R Cod. 12486 unit. This includes the unit and ductwork.
Illustration of a flush-mounted installation for ventilating multiple rooms, with ducts in the wall, for the VORT HR W-ALL 100 DF R Cod. 12486 unit. This shows the unit and its duct connections.

Accessories

Vortice offers a range of accessories to complement the VORT HR W-ALL 100 DF units:

Control Units

Models Description Code
CB LCD R Remote control unit with wired LCD panel, for recessed installation in standard UNI 503 box. 21194
CB LCD W Remote control unit with wired LCD panel, for wall installation. 21195
CB LCD D Remote control unit with wired LCD panel, for recessed installation in standard DIN box. 21381

Housing Boxes

Models Description Code
SCI 503 Flush mounted box for housing the control unit. 22461
SCP 503 Wall box for housing the control unit. 22732

Other Accessories

Models Description Code
WA SR/R Kit for suction and discharge at the window reveal; ideal for installations in historic buildings with constraints on facade aesthetics. 20992
MWS-D Outdoor windscreen made of galvanized, white painted, steel sheet. 13147

BRA.VO Remote Sensors

Models Description Code
BRA.VO S1 Wireless remote sensor for monitoring temperature, relative humidity and VOC concentration in the target room. 13147
BRA.VO S2 Wireless remote sensor for monitoring temperature, relative humidity and VOC, PM2.5 and PM10 concentration in the target room. 13148
BRA.VO S3 Wireless remote sensor for monitoring temperature, relative humidity and VOC and CO2 concentration in the target room. 13149
BRA.VO S4 Wireless remote sensor for monitoring temperature, relative humidity and VOC and CO2, PM2.5 and PM10 concentration in the target room. 13150

CFD Analysis

The development of the VORT HR W-ALL 100 DF series utilized CFD (Computational Fluid Dynamics) technology, similar to that used in Formula 1 car design, to optimize performance, consumption, and noise emissions.

CROSS SECTION WITH VELOCITY VECTORS: This image illustrates the diffusion and propagation of fresh air within a room where the VORT HR W-ALL 100 DF is installed, highlighting effective air exchange.
ISO SURFACE: This image represents the correct and effective propagation of fresh air in a room served by the VORT HR W-ALL 100 DF, ensuring proper air exchange for occupant well-being and health.
STREAM LINE: This image depicts the trajectories of air flows induced by the product, showing the absence of stagnant air zones in the room.
VOLUME RENDERING: This image illustrates the distribution of air speed within the room, emphasizing the absence of overly fast or disruptive air currents.

PDF preview unavailable. Download the PDF instead.

Export\Inglese\Doc Pubblicita VORT HR W-ALL 100 DF 190393 Adobe PDF Library 17.0 Adobe InDesign 20.0 (Macintosh)

Related Documents

Preview Vortice VORT HR W-ALL 100 DF: Decentralized Double-Flow Heat Recuperator
Discover the Vortice VORT HR W-ALL 100 DF, a decentralized double-flow heat recuperator designed for efficient air exchange in residential and commercial spaces. This document details its features, advantages for users and installers, technical specifications, dimensions, performance data, application examples, and accessories.
Preview Vortice VORT HR W-ALL 100 DF Dual-Flow Heat Recovery Units
Discover the Vortice VORT HR W-ALL 100 DF, a series of decentralized dual-flow heat recovery units designed for efficient air exchange in residential and commercial spaces. Learn about its benefits for users and installers, technical specifications, dimensions, and installation examples.
Preview Vort HR W-ALL 100 DF: Decentralized Heat Recovery Ventilators
Discover the Vort HR W-ALL 100 DF, a range of decentralized double-flow heat recovery ventilators designed for efficient air exchange in residential and commercial spaces. Explore its features, benefits, technical data, and installation examples.
Preview Vort HR 300 Neti / Neti H Instruction Manual
This document provides comprehensive instructions for the installation, operation, and maintenance of the Vortice HR 300 Neti / Neti H heat recovery unit. It covers general information, product description, safety warnings, installation guidelines, usage modes, and troubleshooting.
Preview Vortice VORT HRW 30/40/60 MONO EVO Installation and User Manual
Comprehensive guide for the installation, operation, and maintenance of Vortice VORT HRW 30, 40, and 60 MONO EVO ventilation units. Learn about features, safety precautions, and technical specifications.
Preview Vortice VORT HRW MONO EVO WiFi Installation and User Manual
Comprehensive guide for the Vortice VORT HRW MONO EVO WiFi series, covering installation, operation, maintenance, and safety for models like VORT HRW 30, 40, and 60.
Preview Vortice VORT HRI DH Series Dehumidifier Instructions
Comprehensive instructions and safety information for the Vortice VORT HRI 260 DH and VORT HRI 500 DH series dehumidifiers, covering installation, operation, maintenance, and troubleshooting.
Preview Vort Quadro: Manuale d'Uso e Installazione
Manuale completo per i ventilatori centrifughi Vort Quadro di Vortice (Micro 80, 100, Medio, Super). Include istruzioni di installazione, funzionamento, manutenzione e sicurezza.