Installation Guide for Honeywell Home models including: TH8320R1003-Uv VisionPRO 8000 with RedLINK Multistage Thermostat, TH8320R1003-Uv, VisionPRO 8000 with RedLINK Multistage Thermostat, RedLINK Multistage Thermostat, Multistage Thermostat, Thermostat
Edmondson Supply | Honeywell Home TH8320R1003/U VisionPROÂ 8000 with RedLINKÂ Multistage Thermostat, 3 Heat/2 Cool
File Info : application/pdf, 12 Pages, 3.00MB
DocumentDocumentVisionPRO® Series with RedLINK 2.0® Installation Guide Wired Directly to Equipment Dual Powered - C Wire or Battery (C wire or Wire Saver required to use RedLINK accessories) OR RedLINK to Equipment Interface Module TM 2 Wires for Power or Battery Only (no wires) OR RedLINK to TrueZONE Wireless Adapter TM 2 Wires for Power or Battery Only (no wires) TM M37817 Reference to key features * Password is the date code. Current display. Underlined label signifies the current display. Mode control buttons. Use to change settings for Fan or System Heat/Cool. Menu. Select options to: set schedules, view equipment status, change IAQ settings, access installer options*, etc. Current status. Shows system mode (heat/cool), outdoor temperature and humidity (with optional outdoor sensor). Current schedule. Shows desired temperature and schedule status. Indoor conditions. Shows indoor temperature and humidity. Current Time. Alert Light. On when alert message is active or system is set to Em Heat. Flashes for battery-only power; on continuous for 24 VAC. microSD Card Port. Use card to load settings and dealer information. Getting started Follow these basic steps to install this thermostat, link it with the wireless accessories, and set installer options. 1 Installing the thermostat 2 Powering optional RedLINK 2.0 accessories 3 Performing initial setup 4 Finding your password (Date Code) · To add or remove RedLINK 2.0 2126 accessories · To make changes to Installer Setup · To perform an Installer Test 4 Country of origin: Mexico Pays d'origine : Mexique RoHS Compliant M34161B TH8321R1001 1 800 468 1502 Customer.Resideo.com Country of origin: Mexico Manufactured by Resideo Technologies, Inc., Pays d'origine : Mexique RoHS Compliant Thermostat (back view) 2126 4 M34164B Password (Date Code) 1985 Douglas Dr. N. Golden Valley, MN 55422 Conformité RoHS 1985 Douglas Dr. N. Golden Valley, MN 55422 Conformité RoHS Manufactured by Resideo Technologies, Inc., Customer.Resideo.com 1 800 468 1502 TH8321R1001 2 1 Installing the thermostat NOTE: For best RedLINK 2.0 Button performance, mount thermostats at least 2 feet apart. 1.1 Separate wallplate from thermostat. If your thermostat has a button along the top of the wallplate, press button on top and pull to remove the wallplate as shown. Updated models do not have this button. On those models pull evenly along the sides and bottom of the thermostat to separate it from the wallplate. 1.2 Mount wallplate as shown. Mount new wallplate using screws and anchors included with the thermostat. Drill 3/16-in holes for drywall. Drill 7/32-in holes for plaster. Wallplate Thermostat Wallplate (back view) C S1 S1 K S1 S1 RC W O/B R Y Y U1 G G U1 W2 AUX U2 -E Y2 Y2 U2 A L/A 1.3 Connect power. 1.3a Insert supplied AA alkaline batteries for primary or backup power. NOTE: When the thermostat is NOT used with the Equipment Interface Module or the TrueZONE Wireless Adapter, a C wire is required for RedLINK 2.0. 1.3b For 24VAC primary power, connect common side of transformer to C terminal. 3 Thermostat (back view) CONVENTIONAL C S1 S1 K S1 S1 RC W O/B R Y Y U1 G G U1 W2 AUX -E U2 Y2 Y2 U2 A L/A HEAT PUMP 1.4 Wire the thermostat. Is the thermostat wired directly to the equipment? · If the thermostat is wired directly to the equipment: a Refer to the table and wiring diagrams on the next page. b Turn on 24VAC NOW. 24VAC (C wire) is required to connect RedLINK 2.0 accessories. · If the thermostat is used with an Equipment Interface Module or TrueZONE Wireless Adapter, power the thermostat using Rc and C terminals or with batteries. NOTE: The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or CONVENTIONAL C S1 S1 S1 S1 K W O/B RC Y Y R G G U1 U1 W2 AUX -E U2 Y2 Y2 U2 A L/A HEAT PUMP CONVENTIONAL C S1 S1 K S1 S1 RC W O/B R Y Y U1 G G U1 W2 AUX U2 -E Y2 Y2 U2 A L/A HEAT PUMP TrueZONE Wireless Adapter. 1.5 With thermostat removed from sub-base, insert the coin cell battery. NOTE: On some models the coin cell battery compartment slides out from the left side of the thermostat when viewing it from the back (not pictured). 1.6 Mount thermostat on wallplate. NOTE: If your thermostat has hinges at the bottom of the wallplate as shown, insert the thermostat into the hinges, then push the top toward the wall until it snaps together. Updated models do not have hinges. On those models push evenly along the sides and bottom of the thermostat to connect it to the wallplate. Thermostat 4 MCR34279A Wallplate Terminal Designations Terminal C Conventional System Description Common wire from secondary side of cooling transformer (if 2 transformers). Terminal C Heat Pump Description Common wire from secondary side of cooling transformer. Rc* Cooling power. Rc Cooling power. R* Heating power. R Heating power. W Heat Stage 1 O/B Changeover valve for heat pumps. W2 Heat Stage 2 AUX-E Backup Heat/Emergency Heat Y Compressor Stage 1 Y Compressor Stage 1 Y2 Compressor Stage 2 Y2 Compressor Stage 2 G Fan Relay G Fan Relay A U1 / U1 S1 / S1 Connect to Economizer Module or Lighting Panel (TOD). Relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. Input for a wired indoor, outdoor or discharge sensor. L/A U1 / U1 S1 / S1 Connect to Compressor Monitor, Zone Panel, Economizer Module or Lighting Panel (TOD). Relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. Input for a wired indoor, outdoor or discharge sensor. K** Connect to K on C-wire adaptor. K** Connect to K on C-wire adaptor. * Remove factory installed jumper for two transformer systems. ** The THP9045 C-wire adaptor is used on heat/cool systems when you only have four wires at the thermostat and you would like the thermostat to be powered with a common wire. Use the K terminal in place of the Y and G terminals on conventional or heat pump systems to provide control of the fan and the compressor through a single wire--the unused wire then becomes your common wire. See THP9045 instructions for more information. POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILA- TOR SYSTEM C TRANSFORMER 24 120 VAC VAC R THERMOSTAT C K RC R HUM, DEHUM OR VENT TRANSFORM- U1 POWERED ER HUMIDIFIER, 24 120 DEHUMIDIFIER VAC VAC U1 OR VENTILATOR DEHUMIDIFICATION WITH LOW SPEED FAN THERMOSTAT C TRANSFORMER 24 120 VAC VAC R C K RC R 1 U1 OR U1 FIELD INSTALL JUMPER BETWEEN R AND U1 DEHUMIDIFICATION WITH LOW SPEED FAN 1 Wire the thermostat U1 terminal to the low speed fan for dehumidification control at the equipment as shown. The relay can be set to normally open or normally closed in the installer setup. Normally open, dry contacts Normally closed, dry contacts 5 NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR THERMOSTAT SYSTEM C TRANSFORMER 24 120 VAC VAC R C K RC R FIELD INSTALL JUMPER BETWEEN R AND U1 U1 NON-POWERED HUMIDIFIER, U1 DEHUMIDIFIER OR VENTILATOR CONNECTING A HEAT OR COOL STAGE TO U1 THERMOSTAT TRANSFORMER C 24 120 VAC VAC R C K RC 1R U1 U1 2 HEAT STAGE 3, COOL STAGE 3, BACKUP HEAT STAGE 2 FOR HEAT PUMPS, OR GEOTHERMAL RADIANT HEAT 1 U1 terminals are normally open dry contacts when set up for a stage of heating or cooling. 2 You must install a field jumper if the stage of heat- ing or cooling is powered by system transformer. Do NOT install a field jumper if the stage of heating has its own transformer. 2 Powering optional RedLINK 2.0 accessories 2.1 Install batteries in RedLINK 2.0 accessories. · Portable Comfort Control · Wireless Outdoor Sensor* · Wireless Indoor Sensor* · Wireless Entry/Exit Remote* · Wireless Vent and Filter Boost Remote* * Requires setup. See Installer Setup options in Step 3.4. 2.2 Connect gateway to internet and connect to power. 2.2a Connect RedLINK 2.0 Internet Gateway to router or modem with Ethernet cable (RJ45). 2.2b Connect gateway's power cord to an electrical outlet that is not controlled by a wall switch. REDLINPKOWERINTERNET NOTE: If the thermostat is wired directly to the equipment, 24VAC (C wire) is required to connect RedLINK 2.0 accessories. Turn on 24VAC before performing initial setup in Step 3. 2.2a 2.2b M36568 3 Performing initial setup Initial setup options define the type of system you are installing: · Residential or commercial · Non-zoned or zoned · Used with or without an Equipment Interface Module (THM5421) · Used with or without the TrueZONE Wireless Adapter (THM4000) 3.1 Follow prompts on the screen to select the appropriate options. NOTE: If you are connecting the thermostat to the TrueZONE Wireless Adapter (THM4000), refer to the TrueZONE instructions to link the thermostat and RedLINK 2.0 accessories. Then go to Step 3.4. APPLICATION residential 3.2 When you see the prompt Connect RedLINK 2.0 Accessories? Touch No or Yes. Connect RedLINK Accessories? · If you select No, continue to Step 3.4. · If you select Yes, you will be prompted to Press Connect on New Accessories. Continue to Step 3.3. 6 3.3 Connect each RedLINK 2.0 accessory. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 3.3a While the Press Connect message is displayed (listening mode), press and quickly release the CONNECT button on each new RedLINK 2.0 accessory. 3.3b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK 2.0 accessory. Touch s or t to review the list. 3.3c Touch Done at the thermostat after all new RedLINK 2.0 accessories are connected. NOTE: Thermostat displays a countdown timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. 3.4 Finish the initial setup. Finish the setup by selecting the desired options. Touch Done after you select the last option you want to change. The thermostat now displays its Home screen and the thermostat setup is complete. Press Connect on New Accessories. Listening mode Outdoor Sensor has been added THERMOSTAT TYPE programmable 7 4 Finding your password (Date Code) · To add or remove RedLINK 2.0 accessories · To make changes to Installer Setup · To perform an Installer Test Thermostat (back view) Pays d'origine : Mexique RoHS Compliant Country of origin: Mexico Finding your password You can find the date code 2126 on the back of the thermostat, or 1 Touch Menu. 4 Country of origin: Mexico Pays d'origine : Mexique RoHS Compliant M34161B TH8321R1001 1 800 468 1502 Customer.Resideo.com Manufactured by Resideo Technologies, Inc., 1985 Douglas Dr. N. Golden Valley, MN 55422 Conformité RoHS 2126 4 M34164B Password (Date Code) 1985 Douglas Dr. N. Golden Valley, MN 55422 Conformité RoHS Manufactured by Resideo Technologies, Inc., Customer.Resideo.com 1 800 468 1502 TH8321R1001 2 Select Dealer Information. Dealer Information Installer Options 3 Scroll down to see the Date Code. Linking RedLINK 2.0 accessories to the thermostat 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Wireless Manager. 8 TH8321R1001 Date Code: 1324 Installer Options Enter password 0 0 0 0 Wireless Manager Reset To Defaults 5 Select Add Device. The screen displays "Press Connect on New Accessories." The thermostat is now in listening mode. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 5a Press and quickly release the CONNECT button on each new RedLINK 2.0 accessory. 5b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK 2.0 accessory. Touch s or t to review the list. 5c Touch Done at the thermostat after all new RedLINK 2.0 accessories are connected. NOTE: Thermostat displays a countdown timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. Add Device Connected Devices Press Connect on New Accessories. Listening mode Outdoor Sensor has been added Making changes to Installer Setup and performing an Installer Test NOTE: Use a microSD card to save set up time. See next page. 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Installer Setup or Installer Test. 5 Follow prompts on the screen to select the desired setup options or to perform an equipment test. 9 Installer Options Enter password 0 0 0 0 Installer Setup Installer Test Using a microSD card for setup, data logs and software upgrades Note: newer micro SD cards that exceed 8 MB may have compatibility issues. Use a microSD (secure digital) card to save setup time by loading Installer Setup settings, Dealer Information, Holiday Schedules, and Custom Reminders to multiple thermostats. For troubleshooting help, you can save the thermostat Data Logs (Alerts Log and Interaction Log) to a microSD card - then view them on your computer. Also use the microSD card to upgrade the thermostat software. Loading Dealer Information and New Thermostat Software: Computer 1 Visit https://www.resideo.com/us/en/pro/ thermostat-setup/ to enter your dealer information or load new thermostat software. 2 Connect a microSD USB Adapter to your computer to download the file(s). USB adapter microSD card 3 After the file(s) are downloaded, remove the microSD card from the adapter and insert into thermostat. Thermostat To use the microSD card in the thermostat: 1 Slide card into the bottom of thermostat. 2 Select the item to load or save. microSD card 3 Follow the prompts on the screen. · To add information from the card to the thermostat, select Load from SD Card. · To put thermostat information on the card, select Save to SD Card. Installer Setup Dealer Information 4 When you are finished, touch Done, then Home, and remove the microSD card. To replace a thermostat When you replace a thermostat, you must reset the RedLINK 2.0 accessories before connecting them to the new thermostat. Follow the instructions below: At the Portable Comfort Control: Press and hold the blank space (or arrow) in the lower right hand corner of the screen until the display changes (hold for about 4 seconds). Press REMOVE, then YES to disconnect from the old thermostats. To reconnect the thermostat, go to Step 3.2. Portable Comfort Control At the Indoor Sensor, RedLINK 2.0 Internet Gateway, Entry/Exit Remote, Vent-Filter Boost Remote or TrueSTEAM Wireless Adapter: Press and hold the CONNECT button on the accessory until the status light glows amber (hold for about 10 seconds). To reconnect the thermostat, go to Step 3.2. Press and hold At the Equipment Interface Module (EIM): Press and hold the CONNECT button on the EIM until the CONNECTED LED glows amber (hold for about 10 seconds). Follow the prompts on the screen to connect the new thermostat to the EIM. 10 Specifications and replacement parts Operating Ambient Temperature Thermostat: 32 to 120° F (0 to 48.9° C) Portable Comfort Control: 32 to 120° F (0 to 48.9° C) Wireless Outdoor Sensor: -40 to 140° F (-40 to 60° C) Wireless Indoor Sensor: 0 to 120° F (-17.8 to 48.9° C) -For Optimal Battery Life: 35 to 114° F (1.7 to 45.6° C) Equipment Interface Module: -40 to 165° F (-40 to 73.9° C) Return Air Sensor: 0 to 200° F (-17.8 to 93.3° C) Discharge Air Sensor: 0 to 200° F (-17.8 to 93.3° C) RedLINK 2.0 Internet Gateway: 32 to 120° F (0 to 48.9° C) Operating Relative Humidity Thermostat: 5% to 90% (non-condensing) Portable Comfort Control: 5% to 90% (non-condensing) Wireless Outdoor Sensor: 0% to 100% (condensing) Wireless Indoor Sensor: 5% to 90% (non-condensing) Equipment Interface Module: 5% to 95% (non-condensing) RedLINK 2.0 Internet Gateway: 5% to 95% (non-condensing) Physical Dimensions (height, width, depth) Thermostat: 4-15/16 x 4-5/8 x 1-1/8 inches (126 mm x 118 mm x 29 mm) Equipment Interface Module: 9-5/16 x 4-13/16 x 1-19/32 inches (91 x 147 x 42 mm) Wireless Outdoor Sensor: 5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm) Wireless Indoor Sensor: 2-7/8 x 1-7/8 x 15/16 inches (74 x 48 x 24 mm) Portable Comfort Control: 6-1/4 x 3-1/8 x 1-5/8 inches (158 x 80 x 38 mm) RedLINK 2.0 Internet Gateway: 3-7/8 x 3-9/16 x 1-1/8 (99 x 91 x 29 mm) RedLINK 2.0 Communication Frequency: 900 Mhz frequency range Re-Sync Time: RedLINK 2.0 devices re-establish communication within 6 minutes after AC power resumes. Electrical ratings Terminal W - OB Y (cooling) G (fan) W2 - Aux (heating) Y2 (cooling) A-L/A (output) U1/U1 Voltage (50/60 Hz) 18 to 30 VAC and 750 mVDC 18 to 30 VAC 18 to 30 VAC 18 to 30 VAC 18 to 30 VAC 18 to 30 VAC 30 VAC max. 1.00A 1.00A 0.50A 0.60A 0.60A 1.00A 0.50A Max. Current Rating Accessories and replacement parts Accessories / Replacement Parts Equipment Interface Module Wireless Adapter for TrueZone, TrueSteam, or extend wireless range of EIM RedLINK 2.0 Internet Gateway Wireless Entry/Exit Remote Wireless Vent and Filter Boost Remote Portable Comfort Control Wireless Outdoor Sensor Wireless Indoor Sensor Wired Outdoor Sensor 10k ohm NTC Wired Wall-mount Indoor Sensor 10k ohm NTC Supply or Return Air Sensor 10k ohm NTC Cover Plate (covers marks left by old thermostats) C-wire adaptor Part Number YTHM5421R1010, THM5421R1021 THM4000R1000 THM6000R7001 REM1000R1003 HVC20A1000 REM5000R1001 C7089R1013 C7189R1004 C7089U1006 C7189U1005 C7735A1000 THP2400A1019 THP9045A 11 Model Numbering TH8321 TH8320 TH8110 Stages 3H/2C HP 3H/2C HP 1H/1C HP 2H/2C 2H/2C 1H/1C CONV CONV CONV Residential or Commercial P P P Dual Powered - C Wire or Battery P P P Onboard Humidity Sensor P Number of IAQ Relays 1 0 0 Number of Sensor Inputs Economizer / TOD Output 1 1 1 P P Works with Optional Equipment Interface Module* P P P Works with Optional TrueZONE Wireless Adapter* P P P * The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or the TrueZONE Wireless Adapter. * If the thermostat has been setup WITHOUT an Equipment Interface Module or the TrueZONE Wireless Adapter and you would like to add one, you must reset the thermostat back to factory defaults. Press MENU > Installer Options > scroll down to select Reset to Defaults. DISCONNECT POWER BEFORE INSTALLATION. Can cause electrical shock or equipment damage. This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material--special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate CAUTION: MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal. CAUTION: ELECTRONIC WASTE NOTICE: The product and batteries should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health. Must be installed by a trained, experience technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help? For assistance please visit http://customer.resideo.com, or call toll-free: 800-468-1502 Scan for more information TM www.resideo.com Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 69-2760--11 SA Rev. 06-23 | Printed in United States ©2023 Resideo Technologies, Inc. This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-855-733-5465. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. 69-2760-11Adobe PDF Library 17.0