
Instruction Manual for Haier models including: JZY, T-QHA736, JZY, T-QHA638, T-QHA736 Household Gas Hob, T-QHA736, Hob, Household Gas Hob
Haier JZY/T-QHA638-Gas Hob-Haier Malaysia
26 avr. 2022 — GAS SAFETY REGULATIONS AND USE OF YOUR HOB. 1. Please carefully read the nameplate of the gas hob you purchased and make sure the type of gas.
File Info : application/pdf, 2 Pages, 4.36MB
DocumentDocumentHOUSEHOLD GAS HOB INSTALLATION AND USER INSTRUCTIONS JZY/T-QHA736 JZY/T-QHA638 Note: Do not use the hob until you have read the instruction manual. Cod:0070303648-D Even if you have used a gas hob before, it is important that you read these instructions thoroughly before using the appliance, paying particular attention to the installation and safety instructions. If you have any problems installing, operating or cooking with your hob, please check through these instructions to ensure all of them have been adhered to. WARNING! For your own safety, make sure that these instructions on installation, use and maintenance are followed. Please keep these instructions in a safe place for future reference. Should the appliance be sold or transferred, please pass on these instructions to the new owner 1. INTRODUCTION ³Product features Accidental flameout protection design In case of an accidental flameout due to air, overflow, accidental flameout protection function will start to automatically cut off internal gas access of gas hob and avoid mass gas leakage to ensure user safety. Glass panel hob applies tempered glass with explosion-proof mesh, which is safe, durable and easy to clean. Instantaneous ignition The JZY/T-QHA736 model and JZY/T-QHA638 model apply the instantaneous ignition technology which only needs to press the knob and rotate it by 90°. The gas stove can instantly open the valve. The ignition is easy to operate, safe and reliable. Boil dry protection (only for the left stove) When using the gas stove, if you forget to turn off the stove when it's at high heat and causes the bottom of the pan to be overheated and exceed the protection warning temperature (about 290°C~320°C), the anti-overheating protection system will start and make a continuous buzz alarm (approx. 20 seconds) and cut off the gas to avoid safety accidents such as fire caused by dry boiling the pan; (Please make sure that the pan bottom and the sensor are in effective contact, otherwise the boil dry protection function cannot be started reliably; this function is generally started when the pan has been dried thoroughly for several minutes. When the food in the pot has just been dried and burned, this function cannot fulfill the requirement to turn off the fire immediately. After the boil dry protection, if it's re-ignited immediately, it will not work and it can resume normal work after restoration from boil dry protection. Low battery alert (only for the left stove) When the battery voltage drops to the insufficient level to start the boil dry protection smart fire-off function, each time you press the left knob for ignition or press the knob for ignition while the left stove is burning, the gas stove will send out buzzer alarm (about 10 seconds) to remind you to replace the battery in time. After the ignition stops, alarm sound disappears. After the gas stove is used or the gas is cut off by protection function, in order to sustain the long service life of the battery, please turn the knob to the off position. Otherwise, the sensor probe will be in the power on standby detection state and waste battery power; except for the low battery alert function, for boil dry function, it's not allowed to press the knob to perform the ignition operation before the alarm ends. ³Part name Temperature Sensor Left burner cooktop pot rack Right burner Drip pan knob hob shell Note: the picture is the appearance sketch of the product and the specific appearance and color are subject to the purchased product. ³Cookware selection Pan Small pan V-bottom pan pit in the bottom Ceramics / Casserole Proper cookware Improper cookware Note: The minimum bottom diameter of the pan to be used is 120mm . When using the boil dry function for left stove, please use a stainless steel or iron pan. 2 SAFETY INSTRUCTIONS Make sure that this instruction booklet is read thoroughly and understood before attempting to install or operate this hob. The instructions are provided in the interest of your safety. GAS SAFETY REGULATIONS AND USE OF YOUR HOB 1. Please carefully read the nameplate of the gas hob you purchased and make sure the type of gas specified on the nameplate matches the type of gas you are currently using. 2. It is recommended to check the connections of gas hob for air tightness at least once a year and replace the gas-dedicated connecting pipe. 3. In the use process of gas hob, note ventilation, open the window or turn on the ventilation fan on a regular basis to ensure fresh air convection and ventilation. 4. In case of a leakage, avoid all the acts and sources of fire that cause gas explosion, immediately close the gas valve and open the windows and doors for ventilation. 5. It is a legal requirement that all gas appliances are installed by qualified personnel only in accordance with current legislation. It is your responsibility to ensure compliance with the law. 6. Repairs or servicing of this product must only be carried out by an authorised service agent using approved parts. 7. No attempt must be made to modify this appliance under any circumstances. 8. Cooking appliances can become very hot in use please keep children and pets away from them. 9. Do not allow children to operate or play with any part of the appliance. 10.Do not use unstable pans and ensure that the handle is positioned away from the edge of the worktop. 11. In the interest of hygiene and safety, please ensure the hob is kept clean. 12. This appliance is designed for domestic cooking only. Commercial use will invalidate the warranty. 13. Do not cover the hob or place combustible materials on or near the surface even when the hob is not in use. 14. Do not fill deep fat frying containers more than one third full of oil and NEVER leave unattended. 15. Before cleaning the hob, switch off at the mains. 16. When cooking is finished, switch off all controls and allow to cool. 17. These appliances are not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 18.Do not immerse the appliance into water or any other liquid. 19.The overheating protection function is only applicable to the high-heat state. When the flame is small, due to the reduction of the radiant heat of the pot, the protection action time and agility will be affected. 20.The left stove with overheating protection function should use stainless steel or cast iron pans with a bottom diameter of not less than 120mm (does not apply to v-bottom pan, casseroles, etc.). 21.The factors such as the unevenness of the bottom of the pan and the decrease of the gas pressure will adversely affect the heat transfer and accumulation, which will affect the action time and agility of overheating protection and automatic flameout, even the normal start. 22.If you cook on the left stove, such as frying or cooking pancakes, it will cause the overheating protection function to start and cut off the air supply. Please apply the above type of cooking on the right stove. 23.After the low battery alerts, although the gas stove can be normally ignited, the battery power will not be enough to normally start the overheating protection function, so please replace two new high-performance alkaline batteries in time. 24.The boil dry protection function is not completely intelligent. When you are cooking, do not leave the gas stove to avoid accidents. 25.After the boil dry protection function and the overheating protection function are activated, the left stove may be used after the sensor sensing temperature decreases. 26. Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment of the appliance are compatible. 27. The adjustment conditions for this appliance are stated on the label (or data plate) 28. This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation. 29. The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is well ventilated: keep natural ventilation holes open or install a mechanical ventilation device (mechanical extractor hood). 30. Prolonged intensive use of the appliance may call for additional ventilation, for example opening of a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present. 1 2. TECHNICAL DATA Type Rated heat load Applicable Total Heat Input Left burner Right burner gas type 8.0kW JZY/T-QHA736 (582g/h) 4.0kW 4.0kW (291g/h) (291g/h) LPG I3B/P(30) 8.1kW 3.8kW 4.3kW JZY/T-QHA638 (589.5g/h) (276.5g/h) (313g/h) LPG I3B/P(30) Rated pressure (Pa) 3000 3000 Size(mm) Length × Width × Height 750x430x150 730x420x150 Net Weight / Gross Weight(kg) 11.3/13.2 11.5/13.4 3. INSTALLATION INSTRUCTIONS ³Installation method When the gas hob is embedded in the cooktop, please follow the steps 1-5 to install. When the gas hob is put on the cooktop, please follow the steps 4-5 to install. 1. Please choose the cabinet with table thickness greater than 16mm, width not less than 550mm; Note: The cabinet countertops should be made of fire, high temperature-resistant, thermocyclingresistant material. The coating layer and plywood on the cabinet must be fire-resistant and glued together to avoid deformation or surface detachment. 2. According to the hole-digging size and requirements in the instruction, dig holes in the corresponding position of the table with fillet radius around the holes less than 50mm; 3. gas hob fitted with a battery is installed in the hole of the table; 4. Refer to the connection method and connect the gas hob and gas source with the gas special connecting pipe. If the rubber pipe is used, please use the pipe clamp to fix it firmly and avoid turning the gas pipe joint; 5. After installation, carry out gas leakage detection, apply soap water on the connection parts, open the indoor gas valve and carefully observe whether there is a bubble. If bubbles are generated, immediately close the indoor gas main valve, and adjust the intake connection according to the connection method. If there is no bubble, please refer to the instruction manual for ignition commissioning; after commissioning, make sure that the indoor gas main valve is closed. Unit: mm a 50 550 d b 100 16 150 c <R50 Type Overall dimensions Cooktop hole size a(mm) b(mm) c(mm) d(mm) JZY/T-QHA736 750 430 630 330 JZY/T-QHA638 730 420 630 330 Gas hobs should strictly follow the dimensions specified the diagram and Unit: mm keep the distance from combustible materials. If it's surrounded by fire-resistant materials, it's not subject combustibles to the requirements; if a range hood is installed above, it should be 650-700mm away from the hob (specific installation requirements of range hood refer to its instruction manual). 1000 200 Unit: mm combustibles 200 200 3 Do not install the gas hob above poorly ventilated ovens, refrigerators, freezers, dishwashers, sterilizer, or other types of kitchen appliances. Note At least 100mm vacant space shall be reserved below the bottom of hob after the gas hob is embedded into cabinet and all items are prohibited to be stored in the vacant space. To ensure good ventilation and cooling of the gas hob, open 2 openings of about 50mm in diameter on the back or side of the cabinet to the atmosphere to avoid the explosion caused by the accumulation of unburned gas mixture. If the cabinet is not perforated, take ventilation measures. ³Connection method Gas-dedicated rubber hose If you select the gas-dedicated rubber hose (length should not exceed 1.5m) with diameter of 9.5mm, please connect the rubber hose to the intake joint of red marking of gas hob and fix it firmly with pipe clamps. The rubber hose used should meet the relevant safety standards within service period. Rubber hose Pipe clamp Red line Intake joint Note After the installation, make sure the gas connecting pipe is not twisted, squeezed, bent and is not in touch with any movable part of the cabinet, such as drawers, rails, etc .; avoid high temperature area. 4. USER MANUAL Before using for the first time, make sure the gas type specified on the nameplate of the gas hob is the same as the type of gas you are currently using, and confirm that the burner parts, pot rack, knobs, gas-dedicated connecting pipe and gas pipe are correctly installed. There will be residual air in the gas line for the first-time use and ignition will be difficult, which is a normal phenomenon. Please repeat igniting until it's normal. ³Ignite and adjust the fire First of all, install a D dry battery in the battery box at the bottom of the gas hob and follow the order in the diagram to ignite and adjust the fire. Note: when adjusting the fire, please do not adjust the position near "OFF" to avoid Note flameout. It is normal to hear the sound of "bang" when it's off. 1 Open the indoor gas main valve 3 Adjust the fire Main gas valve diagram 2 Press the knob downwards and turn counterclockwise to the horizontal position (the state of high flame). After the fire holes are all ignited, continue to press for 3-5 seconds and release for use after the flameout protection is launched; if the flame is extinguished when releasing, turn the knob clockwise to off position and repeat the above ignition operation. Off High Medium Low 4 Turn the knob clockwise to the vertical "off" position, turn off the gas hob. 5 Make sure to close the indoor gas main valve after using the hob. 4 Cooktop cleaning diagram Warm water Neutral detergent Fire cover cleaning diagram Fine steel needle Cotton brush Burner parts diagram Soapy water leakage detection diagram Left fire cover Thermocouple Sensor Ignition porcelain needle Left burner Right inner fire cover Right outer fire cover Right burner The picture shows the burner parts diagram and please refer to purchased products for details. 6. TROUBLESHOOTING AND HANDLING Fault No ignition Battery Ignition porcelain needle Cause Dead battery No battery, poor contact or reverse installation Ignition porcelain far away from the fire hole Dirty or wet top Troubleshooting method Replace with new battery Re-install and confirm the correct polarity please adjust the discharge distance to 3-5mm Clean the top with a soft cloth and wipe dry Pulser Parts failure Contact service center for maintenance Flame is extinguished when releasing Safety valve Not working due to short press time Thermocouple Dirty top Valve body Valve body is not fully pressed Gas valve Valve is not open or not fully open Re-ignite and keep 3-5 seconds after ignition Clean the top with a soft cloth Hold the knob, press the valve body to the end and ignite Verify that the valve is fully open Failure or difficulty in ignition in pulsed ignition Fire cover Ignition porcelain needle Connecting pipe Battery Fire cover is not installed in place Confirm that the fire cover is properly installed in place Fire hole is blocked Clear and clean the fire hole dirt Dirty or wet top Damp or spilled water Clean the top with a soft cloth Clean with dry and soft cloth Flattened or bent Low battery, slow discharge frequency Replace with new gas dedicated connecting pipe Replace with new battery Gas Too high or too low gas outlet pressure Use gas hob dedicated reducing valve in line with national standards or check the gas supply for gas Loud burning noise Lifted flame and blow-off Fire cover Air regulator Fire cover is not installed in place Excessive air output Confirm that the fire cover is corrected installed in place Re-adjust the air regulator until the flame is burning properlye 6 ³Air regulator adjustment and air volume control When the flame is in poor condition, adjust the air regulator at the bottom of the hob. When the flame is long and yellow, turn the adjustable handle to the right to increase the air volume; when the flame is away from the fire hole, turn the adjustable handle to the left to reduce the air volume. When the flame state is normal, fasten the slot of adjustable handle with fixed throttle gear. Fixed air regulator Adjustable air regulator Correct Lifted flame Yellow flame combustion state state state Note: Normal flame color is light blue Fixed air regulator gear teeth Adjustable air regulator slot Adjustable air handle Turn left to reduce air volume Turn right to increase air volume ³Change the applicable gas type In case of changes in gas type due to relocation or local uniform gas reform, etc., professional trained maintenance personnel will implement gas type changes to the gas hob. Please change the gas type according to the gas type applicable to the models in the technical data list and the dedicated sales area of the product. It is forbidden to disassemble the gas hob by yourself to avoid any safety accident. 5. ROUTINE INSPECTION AND MAINTENANCE Before cleaning and maintaining the gas hob, please close the indoor gas main valve and make sure the gas hob is in a cooling state. Do not dismantle the gas hob cooktop and internal parts during the cleaning process. As ignition porcelain needle surface is made of ceramic material, avoid crush due to hard objects in cleaning and maintenance. Otherwise it will affect the ignition performance. Note The thermocouple is a sensitive component that controls the on-off of the gas line. Regular cleaning is required to prevent dirt from attaching. Otherwise, the accidental flameout protection function will be affected. The sensor is a sensitive part for sensing the temperature and the top must be cleaned frequently to avoid dirt adhesion, otherwise it will affect the boil dry protection function. ³Inspection Gas connecting pipe should be connected reliably without cracks. If leakage is found, please immediately stop using and carry out timely replacement. It is advisable to check the air tightness of the connections (as shown in the soapy water leak detection diagram, apply soap and water on the connections to check the air tightness) and replace the connecting pipe at least once a year. Do not stack inflammable objects around the gas hob. The burner parts must be properly installed in place (as shown in the burner assembly) and the fire holes should not be blocked by spills. Ignition porcelain needle and thermocouple surface can not have residual food, dirt and water. ³ Maintenance Cooktop, pot rack are cleaned with soft cloth dipped in neutral, non-corrosive detergent. In case that the gas contains impurities, after long-term use, it will form carbon deposition, sintering, etc. within fire holes of the fire cover and block the fire holes. In the use of gas hobs, if uneven or individual fire holes are found to be flameless, please turn off the gas hob, remove the fire cover in time until the burner is cooled, use a fine steel needle to remove the dirt and carbon deposition inside the fire hole and use the hob again after the treatment. Do not apply water directly to the fire cover (as the blisters temporarily block the fire hole) and do not rub the coated surface with a harder object, which can cause irreparable damage to the black-coated surface. Please use a soft brush to clean the dirt on the surface of the fire cover. After cleaning, please refer to the illustration of the burner assembly to properly install the inner ring fire cover, outer ring fire cover and pot rack, and confirm that the installation is in place. Otherwise, uneven flame and lifted flame caused may affect the normal use of hob. Scratches beyond repair caused by bump, impact and other improper installation will not be warranted. 5 Fault Cause Troubleshooting method Flameout in use Thermocouple Dirty top Clean the top with a soft cloth Unstable flame Long and yellow flame Gas source Fire cover Air regulator Unstable gas pressure Fire cover is not installed in place Too little air output Fire cover Fire cover is not installed in place Please contact the gas company to handle it Confirm that the fire cover is properly installed in place Readjust air regulator until the flame is burning correctly Confirm that the fire cover is properly installed in place Air source Impurities contained in gas Please contact the gas company to handle it Foul smell Uncertain length of flame Red flame Alarm at ignition Gas leakage Fire cover Gas Battery Connecting pipe ages, cracks, breaks or falls off Replace with new gas dedicated connecting pipe Fire cover is not installed in place and gas Confirm that the fire cover is properly installed in place is leaked while igniting Fire cover is not installed in place Confirm that the fire cover is properly installed in place Blocked fire hole High gas humidity Low battery voltage prompt at low battery state Clear and clean fire hole dirt Calcium contained in moisture causes red flame, but it doesn't affect burning Replace two new batteries Long buzz after 2 minutes of ignition, Sensor alarm and switch off Damaged Turn off knob, alarm sound disappears and contact after-sales service center for repair No flame out after long high-heat Overheating burning of left stove protection unit Long buzz alarm after left stove ignition Solenoid valve Damaged Damaged Contact after-sales service center for repair Turn off knob, alarm sound disappears and contact after-sales service center for repair Correct Disposal of This Product: This marking indicates that this product should not be disposed of together with other household waste. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote sustainable re-use of material resources. To return your unwanted product, please use local return and collect systems or contact the retailer where the product was purchased. They should be able to take the appliance for environmentally-safe recycling. ATTENTION This appliance must be installed in compliance with the current regulations and only installed in rooms equipped with adequate ventilation. Consult the instruction manual before proceeding with installation or use of the appliance. Country of DestinationMALAYSIA Diimport & Diedar oleh Haier Electrical Appliances (Malaysia) Sdn. Bhd.(Co.Reg.No:594702-A) Unit H-08-03, Level3, Block H Persiaran Wawasan,Pusat Bandar Puchong, 47160, Puchong, Selangor, Malaysia. 7