Instruction Manual for Axonics models including: R20, R20 Rechargeable Sacral Neuromodulation System, Rechargeable Sacral Neuromodulation System, Sacral Neuromodulation System, Neuromodulation System
File Info : application/pdf, 15 Pages, 1.71MB
DocumentDocumentNeurostimulator Implant Manual Rechargeable | Model 5101 Rx only Axonics® and Axonics Sacral Neuromodulation System® are trademarks of Axonics, Inc., registered or pending registration in the U.S. and other countries. Axonics, Inc. 15515 Sand Canyon Ave Irvine, CA 92618 (USA) www.axonics.com Tel.: +1-(877) 929-6642 (for U.S.) Tel.: +61 1800 954 009 (for Australia) Fax: +1-(949) 396-6321 AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 1 LABEL SYMBOLS This section explains the symbols found on the product and packaging. Symbol Description Axonics Neurostimulator Axonics Torque Wrench Neurostimulator default waveform with 14 Hz frequency, 0 mA amplitude and 210 µs pulse width Neurostimulator default electrode configuration: Electrode 0: negative (-) Electrode 1: Off (0) Electrode 2: Off (0) Electrode 3: Positive (+) Case: Off (0) Product Serial Number Manufacturer Product Model Number Manufacturing Date Non-ionizing electromagnetic radiation Refer to instructions for use available electronically. Temperature limitation Humidity limitation Pressure limitation Do not reuse Sterilized using Ethylene oxide AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 2 Symbol Rx only IC FCC ID Description Use by Do not use if package is damaged Do not re-sterilize Open here This device is restricted for sale by or on the order of a physician Warning / Caution Product Literature Magnetic Resonance (MR) Conditional Industry Canada certification number This device complies with all applicable Australian Communications and Media Authority (ACMA) regulatory arrangements and electrical equipment safety requirements US Federal Communications Commission device identification This device is packaged in two sterile barriers The Neurostimulator is connected to the Axonics Tined Lead Model 1201 (also included in Model 2201) Medical Device AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 3 TABLE OF CONTENTS LABEL SYMBOLS....................................................... 2 TABLE OF CONTENTS ............................................. 4 INTRODUCTION........................................................ 5 INDICATIONS, WARNINGS, AND PRECAUTIONS 5 DEVICE DESCRIPTION ............................................ 5 Package Contents .................................................................5 System Registration Form and Patient Identification Card ...5 STORAGE AND USAGE ENVIRONMENT............. 6 Component Packaging ..........................................................6 Sterilization ..........................................................................6 SPECIFICATIONS ...................................................... 7 X-RAY IDENTIFICATION ........................................ 8 NEUROSTIMULATOR IMPLANT PROCEDURE 9 Procedure Supplies...............................................................9 Clinical Environment ............................................................9 Neurostimulator Preparation ...............................................9 Creating the Neurostimulator Pocket ...................................9 Connecting the Lead to the Neurostimulator .....................10 Implanting the Neurostimulator.........................................12 Completing the Implant Procedure.....................................13 Post-Surgery Management .................................................13 Replacing the Neurostimulator...........................................13 WIRELESS COMMUNICATION ............................14 CUSTOMER SERVICE .............................................15 AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 4 INTRODUCTION This manual provides information about the Axonics Sacral Neuromodulation (SNM) System Neurostimulator (Model 5101), which is a part of the Axonics SNM System. The Neurostimulator is connected to the Axonics Tined Lead (Model 1201 or 2201). INDICATIONS, WARNINGS, AND PRECAUTIONS · Refer to Indications for Use insert for indications and contraindications. · Refer to Information for Prescribers and Patients booklet for warnings, precautions, adverse events, patient selection and clinical summary. · Refer to MRI guidelines for information on MRI compatibility and requirements. These documents can be found at www.axonics.com/eIFU. DEVICE DESCRIPTION The Axonics Rechargeable Neurostimulator (Figure 1) is part of the Axonics SNM System. The Neurostimulator is a programmable device that is connected to the Axonics Tined Lead, which conducts stimulation pulses to the sacral nerve. Figure 1: Axonics Rechargeable Neurostimulator. Package Contents The Neurostimulator package contains the following: · Neurostimulator · Torque wrench · System registration form · Patient identification card · Product Insert with Indications for Use The contents of the inner package are STERILE. The contents of the Neurostimulator package are intended for single use only. System Registration Form and Patient Identification Card The system registration form registers the device and creates a record of the device in Axonics' implant data system. The patient identification card is also packaged with this device. The patient should carry the identification card at all times. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 5 STORAGE AND USAGE ENVIRONMENT Component Packaging Any component that has been compromised in any way should not be implanted; this includes the re-use of non-reusable product. Do not implant the component if any of the following have occurred: · The storage package or sterile pack has been damaged, pierced, or altered, as sterility cannot be guaranteed, which may lead to infection. · The component itself shows any signs of damage. The component may not function properly. · The use-by date has expired. In this case, component sterility cannot be guaranteed, and infection may occur. · The sterile component was dropped onto a non-sterile surface. In this case, the sterility cannot be guaranteed, and infection may occur. Usage Environment: The following lists the appropriate temperature, humidity, and pressure usage conditions for use of the Neurostimulator: · Temperature: 20 °C to 45 °C · Pressure: The Neurostimulator should function at up to 30 m (100 feet) underwater (403 kPa) and at altitudes up to 3000 m (10,000 feet) associated with activities like hiking and skydiving (as low as 70 kPa) Shipping and Storage Environment: The following lists the appropriate temperature, humidity, and pressure conditions for shipping and storing the Neurostimulator: · Temperature (short term: 3 days): -10 oC to 55 oC · Humidity (short term: 3 days): 15% to 95% · Pressure (short term): 57 kPa to 106 kPa If the Neurostimulator is exposed to extreme temperatures, it may be permanently damaged and should not be used, even if it has returned to a temperature that is within the specified operating range. Sterilization The contents of this package have been sterilized using ethylene oxide. This device is for single use only and should not be re-sterilized. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 6 SPECIFICATIONS Table 1 shows the Neurostimulator physical specifications. For detailed descriptions and specifications for other components and accessories, refer to the product literature for those devices. Table 1: Neurostimulator Specifications. Physical Attributes Height 42 mm Length 22 mm Thickness 6 mm Weight 11 g Volume 5 cc Radiopaque identifier GRJ Stimulation Characteristics Frequency 2 50 Hz Pulse Width 60 330 µs Amplitude 0 8 mA Minimum Amplitude Step Size 0.05 mA Ramping 0 30 s Stimulation Mode Continuous or Cycling Mode of Operation Current-Controlled Power Source Battery Note: All dimensions are approximate. Rechargeable Table 2 shows the Neurostimulator battery recharge interval at various energy settings. Table 2: Battery Recharge Interval Amplitude (mA) Rate (Hz) Pulse width (s) Recharge Interval 0.1 mA 14 210 10 months 1 mA 14 210 8 months 1.5 mA 14 210 6 months 2 mA 14 210 5 months Note: Settings include continuous stimulation at 1200 Ohms impedance Table 3 shows the materials used in the Neurostimulator kit components that come in contact with human tissue. Device Neurostimulator Torque wrench Table 3: Human-Contact Materials. Component Material Neurostimulator case Titanium-Ceramic Neurostimulator header Epoxy Septum and strain relief Silicone Setscrew Titanium Adhesive Silicone Torque wrench handle Polyetherimide Torque wrench shaft Stainless steel Note: The Neurostimulator case, which contains the electronics and power source, is hermetically sealed. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 7 X-RAY IDENTIFICATION The radiopaque marker allows physicians to identify the manufacturer and model number under standard x-ray procedures. For the Axonics Neurostimulator, the designated code is GRJ, which appears as light characters on a black background (Figure 2). Figure 2: The Axonics Neurostimulator radiopaque marker, "GRJ". AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 8 NEUROSTIMULATOR IMPLANT PROCEDURE The following section describes the procedure for implanting the Axonics Neurostimulator. This procedure should be performed when an Axonics tined lead has already been implanted. Procedure Supplies In addition to the general surgical tools required by the physician, the following supplies are needed for the preparation, implantation, programming, and Remote Control pairing of the Neurostimulator: · Axonics Neurostimulator, Model 5101 · Axonics Charging System, Model 1401 · Axonics Clinician Programmer (CP), Model 2501 · Axonics Patient Remote Control, Model 2301 The user should avoid damaging the Neurostimulator and be especially cautious using sharp Caution instruments as damage to the Neurostimulator may require a surgical replacement. Clinical Environment The Neurostimulator implantation must be performed in a clinical setting (Hospital Operating Room), adhering to the necessary surgical protocols and local clinical standards. Neurostimulator Preparation Use the Charger to activate the Neurostimulator. Before opening the sterile Neurostimulator package, the Clinician Programmer (CP) should be used to communicate with the Neurostimulator to verify the ability to communicate and confirm the battery status of the Neurostimulator. If the Neurostimulator battery is low, the device should be charged through the box before implantation by using the Charger. Refer to the CP and Charging System Manuals for further instructions. Creating the Neurostimulator Pocket 1. The Neurostimulator will be placed in a subcutaneous pocket at the anterior surface of the muscle in the upper buttock area. Create a small incision, slightly larger than the smaller dimension of the Neurostimulator, and then bluntly dissect a subcutaneous pocket. Notes: · The Neurostimulator should be placed no deeper than 3.0 cm (about 1 in) below the skin and should be parallel to the skin. If the Neurostimulator is too deep, charging and/or programming the device may be unsuccessful. · The Neurostimulator should be implanted horizontally (Figure 3) with the ceramic side farthest from the patient's midline to facilitate charging and programming. · For a patient with another neurostimulator already implanted, the neurostimulators should be placed as far away as practical and separated by a minimum of 20 cm (8 in). AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 9 Figure 3: Axonics Neurostimulator Implantation Position. Cautions · The Neurostimulator implant site should be irrigated with antibiotic solution, and it is recommended that IV antibiotics be administered perioperatively. Do not soak the Neurostimulator in antibiotic solution as this may affect lead connections. · The Neurostimulator has been sterilized. The Neurostimulator should not be placed on any non-sterile surface. The Neurostimulator should not be placed on skin. An infection may require surgical removal of the implanted system. 2. Use the tunneling tool to create a tunnel from the lead incision site to the neurostimulator pocket. Refer to the Tined Lead Manual for detailed tunneling and lead implant instructions. Connecting the Lead to the Neurostimulator 1. The components should be wiped and dried to remove any fluids before making the connections. If necessary, use sterile water or a non-ionic antibiotic solution, then wipe dry. Caution Failure to completely dry the components could lead to undesired stimulation, intermittent stimulation, or loss of therapy. 2. Ensure that the Neurostimulator connector block is dry and clean. 3. Use the torque wrench to turn the setscrew counterclockwise to back up the setscrew. Do not remove the setscrew from the connector block (Figure 4). AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 10 Figure 4: Use the Torque Wrench to Turn the Setscrew Counterclockwise to Back up the Neurostimulator Setscrew and Allow for Insertion of the Lead. 4. Insert the lead into the Neurostimulator connector block until fully seated and the lead cannot be inserted further. Marker D on the lead should be inside the Neurostimulator strain relief (Figure 5). The retention sleeve on the tined lead should be positioned under the Neurostimulator setscrew. Figure 5: Insert Lead Fully into the Neurostimulator Connector Block. Cautions · Avoid pulling the lead body taut when implanted. · Do not attempt to insert the lead into the Neurostimulator if the setscrew is not sufficiently retracted as doing so may cause damage to the lead and/or cause the lead to not seat fully into the connector block. · Ensure that the setscrew tightens on the retention sleeve, not an electrode. Tightening the setscrew onto the contact could damage the contact, leading to lack of therapy. 5. Fully insert the torque wrench into the hole of the Neurostimulator connector block. Tighten the setscrew by turning the torque wrench clockwise until it clicks (Figure 6). AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 11 Figure 6: Secure the Lead by Tightening the Setscrew Clockwise onto the Retention Sleeve. Cautions · Ensure that the torque wrench is fully inserted into the setscrew. Otherwise, the setscrew may be damaged, which can result in intermittent or loss of stimulation. · The torque wrench is designed for single use only and cannot be assured to work appropriately if used for multiple surgeries. Discard the torque wrench after use. Implanting the Neurostimulator 1. Place the Neurostimulator into the subcutaneous pocket. Ensure that the ceramic side is placed away from the patient's midline to ensure good communication with the Remote Control and ease of recharging (Figure 3). The etched writing can face either towards or away from the muscle tissue. Ensure that the lead curves gently away from the Neurostimulator with no sharp bends. Note: The Neurostimulator should be placed no deeper than 3.0 cm (about 1 in) below the skin and should be parallel to the skin. If the Neurostimulator is too deep or is not parallel to the skin, telemetry and/or charging may be unsuccessful. Do not coil excess length in front of Neurostimulator. Wrap excess length around the perimeter of the Neurostimulator (Figure 7) or place under the Neurostimulator to minimize interference with Cautions telemetry during programming. Figure 7: Wrap Excess Lead Around or Under, but not on Top of, the Neurostimulator. 2. Use the Clinician Programmer to check the impedances and ensure good function and connectivity of the system. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 12 Notes: · The Neurostimulator should be in the subcutaneous pocket during system interrogation to ensure proper readings. · Refer to the Clinician Programming Manual for detailed instruction on checking the system integrity and impedances. 3. Use the suture hole in the header to secure the Neurostimulator to the muscle fascia with non-absorbable silk. Completing the Implant Procedure 1. Close and dress all incisions. 2. Any opened or used products which are no longer sterile should be discarded appropriately. It is recommended to recycle non-biohazardous waste to the extent possible. 3. Program the patient's Neurostimulator and Remote Control. Refer to the Clinician Programming Manual for more detailed instruction. 4. Give a Remote Control and patient ID card to the patient. The patient should carry the Remote Control at all times to be able to adjust or turn off the Caution Neurostimulator. 5. Complete the system registration paperwork and return to Axonics. 6. Schedule the patient's follow-up visits at regular intervals to ensure that the stimulation is programmed optimally. Post-Surgery Management Patients should be monitored post implant. Administer prophylactic antibiotics for 24 hours. Patients should avoid sudden movements and putting pressure on implant site. This will reduce risk of movement or migration of the implanted system. Replacing the Neurostimulator 1. Carefully open the implant site and remove the Neurostimulator from the subcutaneous pocket. Avoid cutting the tined lead to preserve for connection with the new Neurostimulator. 2. Clean the Neurostimulator connector block and lead with sterile water. Wipe both dry with sterile gauze. 3. Use the torque wrench to loosen the setscrew in the Neurostimulator connector block by turning it counterclockwise (Figure 5). 4. Gently remove the lead from the Neurostimulator. Replace any device that shows signs of damage, pitting, or corrosion. Caution 5. Set aside the explanted components. 6. Connect the lead and replacement Neurostimulator according to the steps above. Dispose of explanted devices as bio-hazardous waste. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 13 WIRELESS COMMUNICATION Model: 5101 FCC ID: 2AEEGS IC: 20225-S FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation This transmitter is authorized by rule under the Medical Device Radio Communication Service (in part 95 of the FCC Rules) and must not cause harmful interference to stations operating in the 400.150406.000 MHz band in the Meteorological Aids (i.e., transmitters and receivers used to communicate weather data), the Meteorological Satellite, or the Earth Exploration Satellite Services and must accept interference that may be caused by such stations, including interference that may cause undesired operation. This transmitter shall be used only in accordance with the FCC Rules governing the Medical Device Radio Communication Service. Analog and digital voice communications are prohibited. Although this transmitter has been approved by the Federal Communications Commission, there is no guarantee that it will not receive interference or that any particular transmission from this transmitter will be free from interference. IC Compliance This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. FCC and IC Compliance This device may not interfere with stations operating in the 400.150406.000 MHz band in the Meteorological Aids, Meteorological Satellite, and Earth Exploration Satellite Services and must accept any interference received, including interference that may cause undesired operation. Note: Changes and modifications to the Neurostimulator are not authorized by Axonics could void FCC and IC certification and negate the user's authority to use the product. Quality of Wireless Service This device operates in the 402-405 MHz frequency and the maximum effective radiated power of the Neurostimulator communication is below the limit of 25 µW ERP/EIRP as specified in EU: EN ETSI 301-839 and USA: FCC 47 CFR Part 95; Subpart I. The Remote Control, Clinician Programmer or Charger must be within 1 meter from the implant for successful communication. Wireless Security The Neurostimulator can only communicate with a single Remote Control that is paired to it using the Clinician Programmer. Any Axonics Clinician Programmer or Charger can communicate with a Neurostimulator. Additional mechanisms exist to ensure the integrity of radio data. AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 14 CUSTOMER SERVICE For questions regarding the Axonics SNM System, please contact our Customer Support Center: · In the U.S., call toll-free at +1-877-929-6642 · In Australia, call +61 1800 954 009 · For all regions, email customersupport@axonics.com Additional information and product manuals can be found at our website: www.axonics.com 2024-08 All Rights Reserved. Copyright 2024. Axonics, Inc. 110-0290-001 Rev D AXONICS SNM SYSTEM® Neurostimulator | Rechargeable, Model 5101 Page 15