User Guide for yellobrik models including: CQS 1462 Bi Directional Single Link Converter, CQS 1462, Bi Directional Single Link Converter, Directional Single Link Converter, Single Link Converter, Link Converter
CQS 1462: 12G 4x3G-SDI Bi-Directional SQD/2SI Quad Link to Single Link Converter - LYNX Technik AG
CQS 1462 - LYNX Technik USA
File Info : application/pdf, 2 Pages, 1.73MB
DocumentDocumentApplication Examples 4K Quad Link 2SI/SQD to 12G SDI Conversion Quad Link Input 1 Single Link Output 5 Single Link SFP Output In1 Reset Loop / Out 5 yellobrik® 12G 2SI/SQD Quad/Single Link Converter CQS 1462 SFP Operation Mode Single Link to Quad Link (2SI) Single Link to Quad Link (SQD) Quad Link (2SI) to Single Link Quad Link (SQD) to Single Link Quad Link (Auto) to Single Link Distribution Mode Input Settings OFF BNC SFP Link Indication ON OFF Link Loss ON OFF Reply ON OFF Power + Prog.Settings + 12V 0V WARNING CLASS 1 Laser Product Mode 2SI Operation Link Replacement 6 1 Bit Switch Set Off On 2SI/SQD Black Black Output (Missing Link) (Full Picture) Down 6 16 16 1 Link Loss Settings (Quad to Single Link) PC Control USB Quad Link 2SI / SQD Single Link Converter In/Out 4 In/Out 3 In/Out 2 Out 1 Single Link Output 1 Quad Link Input 2-4 Single Link Input 1 Single Link Loop Single Link SFP Input / Loop Output 12G SDI to 4K Quad Conversion In/Out 4 In/Out 3 In/Out 2 Out 1 In1 Reset Loop / Out 5 yellobrik® 12G 2SI/SQD Quad/Single Link Converter CQS 1462 SFP Operation Mode Single Link to Quad Link (2SI) Single Link to Quad Link (SQD) Quad Link (2SI) to Single Link Quad Link (SQD) to Single Link Quad Link (Auto) to Single Link Distribution Mode Input Settings OFF BNC SFP Link Indication ON OFF Link Loss ON OFF Reply ON OFF Power + Prog.Settings + 12V 0V WARNING CLASS 1 Laser Product Mode 2SI Operation Link Replacement 6 1 Bit Switch Set Off On 2SI/SQD Black Black Output (Missing Link) (Full Picture) Down 6 16 16 1 Link Loss Settings (Quad to Single Link) PC Control USB Single Link Quad Link 2SI / SQD Converter Quad Link Output 1-4 Distribution Mode 1 5+1 Input 1 Output 5 SFP In/Output Reset In1 Loop / Out 5 yellobrik® 12G 2SI/SQD Quad/Single Link Converter CQS 1462 SFP Operation Mode Single Link to Quad Link (2SI) Single Link to Quad Link (SQD) Quad Link (2SI) to Single Link Quad Link (SQD) to Single Link Quad Link (Auto) to Single Link Distribution Mode Input Settings OFF BNC SFP Link Indication ON OFF Link Loss ON OFF Reply ON OFF Power + Prog.Settings + 12V 0V WARNING CLASS 1 Laser Product Mode 2SI Operation Link Replacement 6 1 Bit Switch Set Off On 2SI/SQD Black Black Output (Missing Link) (Full Picture) Down 6 16 16 1 Link Loss Settings (Quad to Single Link) In/Out 4 In/Out 3 In/Out 2 Out 1 PC Control USB Output 1-4 1x Single Link Input 5x Single Link Output + 1x Fiber SFP Note: Fiber SFP are optional equipment and not included with the base module. yellobrik® Technical Specifications SDI I/O 1 x dedicated SDI video input on BNC connector 2 x dedicated SDI video output on BNC connector (1 x Loop/Processed output) 3 x switchable SDI video in-/outputs on BNC connector SMPTE 292M, SMPTE 424M, SMPTE 2081-1, SMPTE 2082-1 Multi-standard operation from 1.5G to 12G 720p (23.98/24/25/29.97/30/50/59.94/60 Hz)* 1080psf (23.98/24/25/29.97/30 Hz)* 1080i (50/59.94/60 Hz)* 1080p (23.98*/24*/25*/29.97*/30*/50/59.94/60 Hz) 2160p (23.98/24/25/29.97/30/50/59.94/60 Hz) Electrical Return Loss Automatic cable EQ to 1.5GHz to 3GHz >15dB >10dB 1.5Gbit/s 3Gbit/s 200m 150m Belden 1694A to 6GHz to 12GHz >7dB >4dB 6Gbit/s 12Gbit/s 90m 85m Belden 4794R Fiber I/O 1 x fiber optic input and output ( optional, see table ) SMPTE 297M - 2006 Power +12VDC @ 13.24W nominal (incl. SFP) - ( 7-24VDC input range ) * Only supported in Distribution Mode We are constantly adding more yellobrik modules. Please visit our website for the latest product updates. www.lynx-technik.com LYNXTechnik AG | www.lynx-technik.com yellobrik® Quick Reference CQS 1462 Bidirectional 2SI / SQD Quad Link to 12G Single Link Converter SDI Loop/ Out 5 SDI In 1 SDI In / Out 2 - 4 (configured automatically) SDI Out 1 In/Out 4 In/Out 3 In/Out 2 Out 1 In1 Reset Loop / Out 5 yellobrik® 12G 2SI/SQD Quad/Single Link Converter CQS 1462 SFP Operation Mode Single Link to Quad Link (2SI) Single Link to Quad Link (SQD) Quad Link (2SI) to Single Link Quad Link (SQD) to Single Link Quad Link (Auto) to Single Link Distribution Mode Input Settings OFF BNC SFP Link Indication ON OFF Link Loss ON OFF Reply ON OFF Power + Prog.Settings + 12V 0V WARNING CLASS 1 Laser Product Mode 2SI Operation Link Replacement 6 1 Bit Switch Set Off On 2SI/SQD Black Black Output (Missing Link) (Full Picture) Down 6 16 16 1 Link Loss Settings (Quad to Single Link) PC Control USB Power SFP Cage Reset Link Loss Settings Operation Modes USB Connection (for LynxCentraal & yelloGUI) WARNING CLASS 1M LASER PRODUCT Laser Radiation Do not look directly into emitter with optical instruments Connections This module has six BNC connectors and one SFP cage. One for dedicated input, one for dedicated output, one for loop or dedicated output, and three switchable in/outputs. The optical port (SFP slot) can be used for transceiver SFPs (i.e. OH-TR-12G-LC) as well as single Transmitter or Receiver SFPs. Operation Modes Operation Mode settings can be changed on the device itself or in our control software. · 6G/12G SDI Single Link 4 x 1.5G/3G SDI Quad Link (2SI) · 6G/12G SDI Single Link 4 x 1.5G/3G Quad Link (SQD) · 4 x 1.5G/3G SDI Quad Link (2SI) 6G/12G SDI Single Link · 4 x 1.5G/3G SDI Quad Link (SQD) 6G/12G SDI Single Link · Auto Quad Link to Single Link Operation Mode Single Link to Quad Link (2SI) Single Link to Quad Link (SQD) Quad Link (2SI) to Single Link Quad Link (SQD) to Single Link Quad Link (Auto) to Single Link Distribution Mode · Distribution mode In Distribution Mode the CQS 1462 can be used for distributing SDI signals from Input 1 (BNC/SFP) to the five Outputs (BNC) as well as the fiber Output (SFP). Operation Modes Following Input Settings are available: · Auto Select: Switch Automatic andOMpaenruaatlioSenleMctoiodneof input Input Settings sources ( Ignored in quad to sinSginlgelemLinok dtoeQsua)d Link (2SI) · Link Indication: Add numberSeindgleoLvinekrltao yQufaodrLoinku(tSpQuD)ts to BNC OFF SFP indicate link source. Quad Link (2SI) to Single Link Link Indication ON OFF · Link Loss Reply: Choose howQQtuuoaaddrLLeiinnskkp((ASouQntDod)) ttootoSSiinnmgglleeisLLsiinninkk g links. » Mode shows in which modes supporDtiswtrihbuitciohn MOopdeerations. Link Loss ON Reply ON OFF OFF » Operations are: Link Replacement (only 2SI output) duplicates input link 1 to preserve image brightness. Black "Missing Link" replace missing link with Mode 2SI Operation Link Replacement 6 1 Bit Switch Set Off On 2SI/SQD Black Black Output (Missing Link) (Full Picture) Down 6 16 16 1 frame black (reduces the image brightness). Black "Full Picture" output full frame black image Link Loss Settings (Quad to Single Link) if a single link is lost. Output Down turns off the output entirely ( no SDI output signal ). » Bit Switch Settings visualizes how to set the DIP switches. Power The module requires a 12V DC power input and the LED confirms when power is connected. A power supply is provided, however, if you use your own power supply, please provide a clean 12V DC power source(or between 7 and 24V DC). Module LEDs The module has several LEDs included to indicate status: SDI Present LED (electrical and fiber input have individual LEDs) Green Valid SDI signal Off No valid or missing SDI signal Power / Prog Setting LED Green Power OK and no internal programmed settings are present Yellow Power OK and control software exclusive settings are not at factory default* Yellow (blinking) "Locate" functionality enabled via control software to identify physical module Red Power OK and physical settings are overwritten by software settings Red (blinking) Hardware malfunction ( Fan Error, Overheating, etc.) Off Power not present * The module can be reset to factory defaults by using the reset switch Central Control Interface via USB The USB connection on the module is for firmware updates and control via the Lynx Centraal or yelloGUI software applications. Please register to connect to our update server [Database settings > Registration] and you will receive the latest firmware updates yelloGUI automatically. Check in the "update" section on Lynx Centraal or look for the red update flag in yelloGUI. Firmware updates and our control software are free of charge. LYNX | CentraalTM Fiber I/O Options The optional fiber I/O SFP modules plug into the side of the yellobrik and are ideal to bridge longer distances. We offer Singlemode CWDM versions (in 18 different wavelengths according to ITU-T G694.2), as well as Singlemode. This module can use TR (Transceiver), TX (Transmitter), RX (Receiver) SFPs. Option # OH-TR-12G-LC Wavelength 1310 nm TX Power -5 ... +0.5dBm OH-TR-12G-XXXX-LC 1270 - 1610nm -2 ... +3dBm OH-TX-12G-LC 1310nm -5 ... +0.5dBm OH-RX-12G-LC 1310nm - RX Sensitivity 6 - 12G: -10dBm 1.5 - 3G: -14dBm 6 - 12G: -10dBm 1.5 - 3G: -14dBm 6 - 12G: -10dBm 3G: -14dBm 1.5G:-16dBm Max Distance 10km (6.2miles)* 10km (6.2miles)* 10km (6.2miles)* 10km (6.2miles)* Power Lead Strain Relief The module (different module shown here) has a small hole in the case located above the power connection. This prevents the power lead from being accidentally pulled out. Use the supplied tie-wrap and secure the lead, as shown below. Mounting Solutions The optional RFR 1001 mounting bracket can be used to permanently mount the module on any surface or on 19" rack rails. The optional RFR 1200 rack mount can be used to mount up to 14 yellobrik modules permanently. In addition, the RFR 1200 can provide full power redundancy for all mounted yellobriks.