9

Enriqueta Arboli Hewlett-Packard Company

Ecler VIDA-24Q


File Info : application/pdf, 150 Pages, 8.12MB

PDF preview unavailable. Download the PDF instead.

EC-CVIDA24Q 6 user manual CVIDA24Q 65e9989edda33
Web HW GUI

VIDA Series
AMPLIFIERS Digital Amplifiers

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

USER MANUAL

50-0429-0106

VIDA Series

E N

TABLE OF CONTENTS
1. PRECAUTIONS ........................................................................................................................5 1.1 Important Remark..............................................................................................................................5 1.2 Important Safety Instructions.........................................................................................................6 1.3 Cleaning ................................................................................................................................................6
2. PACKAGE CONTENTS ..........................................................................................................7 3. DESCRIPTION and FEATURES............................................................................................8
3.1 Main Features......................................................................................................................................8 4. INSTALL & CONNECT............................................................................................................9
4.1 Location, Assembly and Ventilation.............................................................................................9 4.2 Mains Connection ..............................................................................................................................9 4.3 Analogue Input Connections....................................................................................................... 11 4.4 Player and Micro SD Card ............................................................................................................ 11 4.5 Digital Audio Inputs and Outputs .............................................................................................. 12 4.6 Amplified Output Connections ................................................................................................... 12
4.6.1 OUT MODE........................................................................................................................ 12 4.6.2 Operation Example ......................................................................................................... 13 4.7 Auxiliary Output Connections..................................................................................................... 13 4.8 GPI Ports............................................................................................................................................ 14 4.8.1 Connecting the GPI Remote Control Ports ............................................................. 14 4.9 GPO Ports ......................................................................................................................................... 15 4.10 External Mute ................................................................................................................................... 15 4.11 Ethernet Ports .................................................................................................................................. 16 5. START-UP and OPERATION ............................................................................................ 17 5.1 Start Up .............................................................................................................................................. 17 6. PANEL FUNCTIONS ............................................................................................................ 18 6.1 Front Panel ........................................................................................................................................ 18 6.2 Rear Panel ......................................................................................................................................... 18 7. TECHNICAL DATA .............................................................................................................. 19 7.1 Technical Specifications................................................................................................................ 19 7.1.1 VIDA-24Q.......................................................................................................................... 19 7.1.2 VIDA-16Q.......................................................................................................................... 24 7.2 Mechanical Diagram....................................................................................................................... 29 7.2.1 VIDA-24Q.......................................................................................................................... 29 7.2.2 VIDA-16Q.......................................................................................................................... 30 8. WebGUI .................................................................................................................................. 31

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
2

Panels APP

Routing GPOs VersaPower Groups Player

8.1 Updates.............................................................................................................................................. 32 8.2 First steps .......................................................................................................................................... 34
8.2.1 Automatic connection using the Ecler VIDA user web app............................... 34 8.2.2 Automatic connection using a computer ................................................................. 34 8.2.3 Manual connection .......................................................................................................... 35 8.3 Login ................................................................................................................................................... 36 8.3.1 Keep me logged in .......................................................................................................... 37 8.3.2 Forgot password ............................................................................................................. 37 8.3.3 Public Panels..................................................................................................................... 37 8.3.4 Setup Device ..................................................................................................................... 38 8.4 Navigation ......................................................................................................................................... 38 8.4.1 App Bar............................................................................................................................... 39 8.5 Settings .............................................................................................................................................. 41 8.5.1 Device.................................................................................................................................. 42 8.5.2 Network .............................................................................................................................. 44 8.5.3 Knobs/GPIOs..................................................................................................................... 46 8.5.4 Energy Saving................................................................................................................... 48 8.5.5 Health.................................................................................................................................. 50 8.5.6 Backup and Firmware .................................................................................................... 52 8.6 Status.................................................................................................................................................. 54 8.7 Routing ............................................................................................................................................... 56 8.8 EQ (Equalizer)................................................................................................................................... 64 8.9 GPOs ................................................................................................................................................... 66 8.10 IO Setup (Input and Output Setup) ........................................................................................... 67 8.10.1 Inputs Setup ...................................................................................................................... 67 8.10.2 Sources Setup .................................................................................................................. 69 8.10.3 Amp & Aux Outs Setup ................................................................................................. 71 8.10.4 Digital Outs Setup ........................................................................................................... 73 8.11 VersaPower ...................................................................................................................................... 74 8.12 Processing ......................................................................................................................................... 76 8.12.1 Inputs Processing ............................................................................................................ 76 8.12.2 Outputs Processing ........................................................................................................ 81 8.13 Groups ................................................................................................................................................ 92 8.14 Events ................................................................................................................................................. 97 8.14.1 Event Knob ......................................................................................................................100 8.14.2 Event GPI .........................................................................................................................101 8.14.3 Event Load Preset .........................................................................................................105 8.14.4 Event Calendar ...............................................................................................................106

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
3

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.14.5 Event External Mute .....................................................................................................113 8.15 Player ................................................................................................................................................114
8.15.1 Playlists.............................................................................................................................116 8.15.2 Browser ............................................................................................................................119 8.16 Users .................................................................................................................................................121 8.17 Panels ...............................................................................................................................................125 8.18 Register ............................................................................................................................................130 9. ECLER VIDA APP...............................................................................................................135 9.1 Login .................................................................................................................................................136 9.2 Setup Device ..................................................................................................................................137 9.3 Home.................................................................................................................................................139 9.4 My Panels ........................................................................................................................................141 9.5 Settings App...................................................................................................................................142 10. TP-NET PROTOCOL..........................................................................................................145 10.1 Introduction TP-NET Protocol ..................................................................................................145 10.2 VIDA Parameters ..........................................................................................................................147

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

4

1. PRECAUTIONS

1.1 IMPORTANT REMARK

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of " " may be of
sufficient magnitude to constitute a risk of electric shock. The external wiring connected to the terminals requires installation by an instructed person or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to rain or
moisture.
WARNING: A device with Class I construction shall be connected to a mains socket-outlet
with a protective earthing connection.
WARNING: Ecler products have a long lifetime of more than 10 years. This
product must not be discarded, under any circumstance, as unsorted urban waste. Take to the nearest electrical and electronic waste treatment centre.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
5

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

1.2 IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this device near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other device (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the device.
11. Only use attachments/accessories specified by the manufacturer.

12. Unplug the device during lightening sorts or when unused for long periods of time.
13. Refer all servicing to qualified personnel. Servicing is required when the device has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the device, the device has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
15. Equipment is connected to a socketoutlet with earthing connection by means of a power cord.
16. The marking information is located at the bottom of the unit.
17. The device shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on device.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1.3 CLEANING Clean the unit with a soft, dry clean cloth or slightly wet with water and neutral liquid soap only, then dry it with a clean cloth. Be careful that water never gets into the unit through any hole. Never use alcohol, benzine, solvents or abrasive substances to clean this unit.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused to people, animal, or objects due to failure to comply with the warnings above.
6

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

We thank you for the trust you have placed in us by choosing an Ecler VIDA Series device!
It is VERY IMPORTANT to carefully read this manual and to fully understand its
contents before any connection in order to maximize your use and get the best performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its maintenance be carried out by our authorised Technical Services.
All ECLER products are covered by warranty, please refer to www.ecler.com or the warranty card included with this product for the period of validity and conditions.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

DESCRIPTION & FEATURES

Ecler is truly committed with the environment and planet sustainability, energy saving and CO2 emission reduction. Recycling materials and using non-contaminant components are also top priorities in our green crusade.
Ecler has deeply evaluated and analyzed the environmental impacts of all the processes involved in the production of this product, including packaging, and has alleviated, reduced and/or compensated for them.

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

2. PACKAGE CONTENTS
· 1 unit of one of the VIDA Series models. · Universal Mains cords. · Euroblock Connectors (inputs /outputs). · Desktop feet, rack 19" installation hardware. · First Steps Guide. · Warranty Card.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

7

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. DESCRIPTION and FEATURES
VIDA Series is a family of digital amplifiers, with different power levels: VIDA-24Q with 2400W of power and VIDA-16Q with 1600W. Both with 4 amplified outputs that can be independently configured in high (100/70V) or low (8/4/2ohm) impedance. The VersaPower technology, developed by Ecler, allows an asymmetrical power distribution, and thanks to the Smart VersaPower tool it helps installers by facilitating a smart and fast configuration. In addition, the Class D amplification technology as well as the configurable 4-outputs auto standby and sleep mode functions, both configurable, further improve energy efficiency.
The VIDA Series offers a wide range of possibilities thanks to its 4 analogue and 4 DanteTM / AES67 digital inputs, audio player - with microSD slot for local audio files ­ as well as signal generator, plus 2 auxiliary line outputs and 4 DanteTM/ AES67 digital outputs.
All these features are managed from its intuitive web application which, among other functionalities, allows signal routing - matrix -, audio signal processing - such as equalisation or limiters -, priority management, GPIO configuration through events, as well as calendar events, playlist management and SD card content, thus facilitating the start-up of the audio-visual installation, its maintenance and customisation.
Thanks to the Android/iOS/Web application available to the end user, the audio installation can be managed by them in an easy, intuitive, and customised way.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

3.1 MAIN FEATURES

· 4 VersaPower amplified outputs with asymmetrical power management.
· 4 DanteTM/ AES67 outputs and 4 DanteTM/ AES67 inputs.
· 2 auxiliary outputs. · 4 analogue inputs.

· MicroSD/SDHC card slot audio player.
· Internal matrix and signal processing.
· Web application for device configuration.
· Smart power management Smart VersaPower.

· Control and scheduled events for automation.
· Customize user panels. · Remote control user
application for iOS/Android/Web.
· Energy saving (Ultralow power consumption mode).

VersaPower is the amplification technology, developed by Ecler, that allows asymmetrical power distribution among amplified outputs, independent of load.
Smart Versapower is the tool that allows automatic gain and sensitivity adjustment, to distribute in an easy and quick way, the total power among the amplified outputs.
8

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4. INSTALL & CONNECT
The equipment must be correctly grounded (ground resistance, Rg = 30 Ohm or less). The environment must be dry and dustless. Do not expose the unit to rain or water splashes, and do not place liquid containers or incandescent objects like candles on top of the unit.
Do not obstruct the ventilation grilles with any kind of material. If the device requires any intervention and/or connection/disconnection, it must be first powered off.
Do not handle the speaker output terminals with your device turned on, there are high voltages. The output cabling should be connected by a qualified technician. Otherwise only use pre-made flexible cables. There are no user serviceable parts inside the amplifier.
Non-compliance with the instructions or neglecting warnings may cause malfunction or even damage the unit.
· Avoid turning on the device without the speakers connected to its outputs and without having previously set the volume/gain controls to minimum level.
· Always use shielded cables to make connections between devices. · In an amplifier, avoid placing the speaker output cables close to other signal
cables (micro, line...). This may cause the system to oscillate, damaging the amplifier and speakers.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

4.1 LOCATION, ASSEMBLY AND VENTILATION
Vida series devices have a 19" rack format (2RU).
It is very important not to enclose the amplifier or expose it to extreme temperatures as it generates heat. It is also necessary to promote the passage of fresh air through the ventilation holes of the chassis. The ventilation system forces the air flow, front to back, through the unit.
If multiple products are installed in the same rack or in a cabinet with closed doors, it is highly recommended to install fans in their upper and lower ends for a forced airflow from the bottom up. This upward air flow will help to dissipate the heat generated inside.
It is advisable not to place power amplifiers under other appliances, but upon these ones, leaving at least one rack unit off between each device and installed above and below it in the rack frame.
4.2 MAINS CONNECTION
VIDA operates on alternating voltages from 90 to 264V and 47 to 63Hz. This device is equipped with an oversized power supply capable of adapting without any type of adjustment to the mains voltage of any country in the world.
9

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

On the rear panel, next to the IEC power connector, there is an On/Off switch for the unit.

Web HW GUI

PRECAUTIONS

On the front panel there is button ON/SLEEP with its LED indicator, that illuminates when the unit is in operation, and soft-blinks when it is in sleep mode.

PACKAGE CONTENTS

DESCRIPTION & FEATURES

Do not allow the mains cable to run parallel to the shielded cables carrying the audio signal, as this may cause humming.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

10

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4.3 ANALOGUE INPUT CONNECTIONS
VIDA rear panel provides analogue, balanced, line level signal inputs. The selection of hardware inputs and their routing and mixing towards either amplifier channel is performed from its embedded web application. Please refer to the web application manual for more information on www.ecler.com

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Signal input connectors are 3 position screw terminal block. The wiring is:

Live or direct signal

>

Cold or inverted signal >

Ground

>

Terminal + Terminal Terminal

For unbalanced connection short-circuit pin to pin -.
4.4 PLAYER AND MICRO SD CARD VIDA integrates a stereo audio player able to play audio files from local storage device (microSD card), for background music or voice messages. Includes playlist management and integration with device's calendar events for automation. Also available for customizable user panels. Fully configurable, through VIDA web application. Refer to the web application manual for more information. MicroSD Card slot is located in the rear panel. Insert the microSD card into the slot, until a click sound is heard. To extract it, push the microSD card inside the slot, until a click sound is heard, then, it will be released.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

11

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4.5 DIGITAL AUDIO INPUTS AND OUTPUTS
VIDA allows the reception of 4 channels of digital audio DANTETM/ AES67 and the sending of 4 channels of digital audio DANTETM/ AES67 through an Ethernet network compatible with the transport of digital audio over IP through the DANTETM protocol. The routing of the digital audio signals DANTETM/ AES67 through the Ethernet network, as well as the network configuration of the ports DANTETM/ AES67 (IP addresses, mask, etc.) of the VIDA, is managed by the software application Dante Controller.
For more information, please refer to the developer's documentation: www.audinate.com/products/software/dante-controller.
AES67 is enabled by default. DanteTM devices cannot subscribe to AES67 streams from other DanteTM devices.
4.6 AMPLIFIED OUTPUT CONNECTIONS
The rear panel is fitted with two position screw terminal block for each amplified output.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Always respect the relative polarity for outputs (+ and ­ on each output connector), wiring and speakers. 4.6.1 OUT MODE Allows configuring each amplified output, individually, to operate with high or low impedances.
Select the appropriate operation mode to do not damage the loudspeakers. Never connect loads below 2 ohms when working in low impedance mode.
Make sure to match the impedance of the total load connected to the loudspeakers, when working in low impedance for a correct performance. If impedance values do not match, select the closer one above.
12

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4.6.2 OPERATION EXAMPLE

AMP OUT1: HIZ-100V AMP OUT2: HIZ-70V
When HIZ is selected, 2ohm switch has no effect.

AMP OUT3: LOZ-8ohm AMP OUT4: LOZ-2ohm
When LOZ is selected, and 2ohm switch is in 2ohm position (down), switch 4/8ohm has no effect.

The connection cable that joins the amplifiers outputs and the loudspeakers must be of good quality, sufficient section and as short as possible. This is most important when the distances to cover are long ones i.e., up to 10 meters it is recommended to use a section not inferior to 2.5mm2 and for superior distances 4mm2.

4.7 AUXILIARY OUTPUT CONNECTIONS
VIDA rear panel provides two analogues, balanced, line level auxiliary outputs. Their independent routing, mixing, and processing is performed from VIDA embedded web application.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Please refer to the web application manual for more information.
For unbalanced connection short-circuit pin to pin -.
· If an auxiliary output is connected to an amplifier or audio device with a balanced input, all terminals must be connected point by point and between the two devices.
· When connecting an output channel to an amplifier or device with an unbalanced audio input, leave the ­ terminal unconnected.

Live or direct signal

>

Cold or inverted signal >

Ground

>

Terminal + Terminal Terminal

13

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4.8 GPI PORTS
VIDA rear panel provides four 0-10VDC remote control ports, labelled "GPI 1-4", to which you can connect analogue devices such as the WPa series wall panels. With the VIDA web application, a function can be assigned to each of these ports: a GPI port can control remotely volume of sources, outputs (amplified, auxiliary or digital), and local and network groups, including general volume. Also, loading presets or playlists.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Please refer to the web application manual for more information.

4.8.1 CONNECTING THE GPI REMOTE CONTROL PORTS The GPI connectors are Euroblock type. The assignment of the connection is as follows:

Positive, + 10 VDC

> Pin +

Variable voltage, 0-10 VDC > Pin 1-4

Ground

> Pin

· Up to 16 remote control ports can be connected in parallel to the same hardware control potentiometer. Ground connections of all devices those ports belong to must be joined.
· The connection cables can be up to 500m long if a section of 0.5mm2 is used. · Consult the available accessories at www.ecler.com.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

14

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4.9 GPO PORTS
VIDA has on its rear panel 4, relay outputs NO / NC (normally open / normally closed). Each of these outputs can have its status change associated with a user preset by means of a specific function programmed through VIDA web application, such as a calendar event or the touch of a key available on a user panel. In this way, it is possible to interact with external equipment, such as motors for projection screens or movable partition walls, lights, sirens, GPI inputs from other equipment, etc.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

4.10 EXTERNAL MUTE VIDA has on its rear panel a control input, or EXT. MUTE port (Normally Open = MUTE OFF / Closed = MUTE ON), which allows the activation /deactivation of the mute of audio outputs (zones) of the unit by means of a push button, relay or external potential free contact closure.
· The assignment of outputs affected by the MUTE port is configured from VIDA web application.
· Please refer to the VIDA web application manual for more information.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

15

4.11 ETHERNET PORTS
The RJ-45-type ETHERNET connectors on the rear panel, named NET1 and NET2, allows the equipment to be connected to an Ethernet network, or directly to a computer or other device with an Ethernet interface, point-to-point.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

This connection enables, within a local network, the following: · Global programming and management of the VIDA unit using the VIDA embedded web application and a standard web browser running on a computer, tablet, etc. · Connection of client devices for end-user management of areas of the installation through the VIDA application, compatible with Android and iOS, or through standard web browsers running on computers, tablets, etc. · Connection to Internet for clock synchronization (calendar events), automatic, firmware updates and other tools. · Reception of 4 channels of digital audio DanteTM/ AES67 and sending of 4 channels of digital audio DanteTM/ AES67. · Connection of third-party devices for integration in control systems (Crestron®, Extron®, AMX®, Vity®, Medialon®, etc., registered trademarks by their manufacturers), using the NET protocol embedded in VIDA devices. Refer to the TPNET protocol manual for more information.
DanteTM/ AES67 digital audio license is included.
VIDA features two ports with RJ-45 interface in its rear panel: · Net1 (Control): WebGUI, control panels, third party control and other control packages are sent/received over Net1. · Net2 (Control + DanteTM/ AES67): control and DanteTM/ AES67 Audio perform over the same network.
Use Net1 and Net2 in different networks. Configuring both, Net1 and Net2, over the same local network might cause malfunctioning in network features of the device.
16

5. START-UP and OPERATION
5.1 START UP When the rear panel Power switch is pressed, the amplifier is powered and can be switched on, briefly holding the front ON/SLEEP button or remotely from the VIDA web application or with the NET protocol.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

In a complete audio installation, it is important to start up the equipment in the following sequence:
1. sound sources 1. mixer 2. equalizers 3. active filters 4. processors 5. power amplifiers. To turn them off the sequence should follow an inverse pattern.
17

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

6. PANEL FUNCTIONS
6.1 FRONT PANEL

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

1. Control knobs, KNOB1-4 2. On/Sleep Button 3. Signal indicator LED 4. Clip indicator LED 5. Protection indicator LED 6. Standby/mute indicator LED
6.2 REAR PANEL

7. Limit indicator LED 8. Thermal indicator LED 9. DanteTM/ AES67 indicator LED 10. Data indicator LED 11. On/Sleep indicator LED

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Power switch 2. Mains socket base 3. Amplified outputs, OUT1-4, 2-pin
Euroblock. Pitch: 7,62 mm 4. Analogue inputs, IN1-4, 3-pin
Euroblock, balanced, pitch 3,5 mm 5. MicroSD slot 6. RJ-45 ethernet network ports,
NET1-2

7. GPO ports, GPO1-4 8. GPIs ports, GPI1-4 9. External mute port 10. Outputs configuration dip switches,
OUT MODE 11. Auxiliary outputs, AUX1-2, 3-pin
Euroblock, balanced, pitch 3,5 m

18

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

7. TECHNICAL DATA

7.1 TECHNICAL SPECIFICATIONS

7.1.1 VIDA-24Q

VIDA-24Q

INPUTS

Number of Inputs
Analogue input connection type Digital input connection type Input configuration

4 analogue input channels 4 DANTETM/ AES67 Network Rx channels 1 embedded player, 1 embedded signal generator IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm. Ethernet, managed via DanteTM/ AES67 Controller Digital matrix 4 in x 6 out (Settings by embedded web application)

AMPLIFIED OUTPUTS

Number of amplified outputs Amplified output connection type
Output configuration

4 2-pin Euroblock. Pitch: 7,62 mm Ref: DEGSON 5EDGRC-7.62 Lo-Z/Hi-Z, 70V/100V, 4/8/2 Output mode selection per channel Rear panel DIP SWITCH selectors

VERSAPOWER

SYMMETRICAL - All channels driven @1kHz @CF9dB @ 1%THD

Max output power @ 8 Max output power @ 4 Max output power @ 2 Max output power @ 100V Max output power @ 70V

600W 600W 600W 600W 600W

ASYMMETRICAL - Single channel driven @1kHz @CF9dB @ 1%THD

Max output power @ 8 Max output power @ 4 Max output power @ 2 Max output power @ 100V Max output power @ 70V

1400W 2400W 1600W 2400W 2000W

AUXILIAR OUTPUTS

Number of auxiliar outputs Auxiliar output connection type

2 AUX1-2: 3-pin Euroblock, balanced (Euroblock pitch 3,5 mm. Settings by embedded web application)

DIGITAL OUTPUTS

Number of digital outputs 4 Digital output connection type Ethernet, managed via DanteTM/ AES67 Controller

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

19

SIGNAL Voltage gain 28 to 40 dBV 30,2 to 42,2 dBu
Input sensitivity -6 to +6 dBV -3,78 to 8,2 dBu 0,5 to 2 Vrms (adjusted by means of Smart Versa Power utility)
Input impedance >24k (balanced) Max input level +18 dBV +20,2 dBu (@ Gain 34 dBV)
Frequency response 15Hz-25kHz (-3dB, 1W any load) THD + Noise < 0,1 % 0,015 Typ (@ 1kHz, from 0,1W to Full Power) SNR 95 dBA (40dB Gain, from 20Hz - 20kHz) Crosstalk >80dB (@ 1kHz) CMRR > 65 Typ (from 20Hz-20kHz)
Damping factor >500 (@ 8, from 20Hz to 1kHz) ELECTRICAL
Power supply Universal, regulated SMPS with PFC AC mains requirement 100-240 V @ 50-60Hz ((±10%) Power factor correction > 0,96 (Output Power > 500W)
AC mains connector IEC C14 inlet (10Amax) POWER & HEAT @230VAC
1/4 POWER, @ 4 (all channels driven) Power 848 W | 888 VA
Current Draw 3,88 Arms Thermal Loss 214,1kcal/h | 849,8BTU/h 1/8 POWER, @ 4 (all channels driven)
Power 498 W | 536 VA Current Draw 2,33 Arms Thermal Loss 170,3kcal/h | 675,8BTU/h IDLE (all channels driven)
Power 72 W | 122 VA Current Draw 0,52 Arms Thermal Loss 61,9kcal/h | 245,7BTU/h SLEEP MODE (all channels driven)
Power 4,1 W | 23,8 VA Current Draw 0,1 Arms Thermal Loss 3,5kcal/h | 14BTU/h

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
20

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

POWER & HEAT @120VAC 1/4 POWER, @ 4 (all channels driven) Power 855 W | 865 VA Current Draw 7,37 Arms Thermal Loss 219,3kcal/h | 870,3BTU/h 1/8 POWER, @ 4 (all channels driven) Power 483 W | 493 VA Current Draw 4,16 Arms Thermal Loss 157,4kcal/h | 624,6BTU/h IDLE (all channels driven) Power 68 W | 89 VA Current Draw 0,75 Arms Thermal Loss 58,5kcal/h | 232,1BTU/h SLEEP MODE (all channels driven) Power 3,6 W | 10,2 VA Current Draw 0,09 Arms Thermal Loss 3,1kcal/h | 12,3BTU/h
TECHNOLOGIES Amplification technology Class D Energy saving Auto standby function programmable per channel Sleep Mode function selectable Efficiency 72% (1/4 POWER, @ 4) Cooling Fan (forced air, front to back airflow. Temperature controlled continuously variable speed) Maximum fan noise 45dB (maximum acoustical noise @1m)
PROTECTIONS DC protection Yes (protects loudspeaker and installation against DC and infrasonic signals at the outputs) HF protection Yes (protects the loudspeakers against non-audible, strong, non-musical high frequency signals)
Short-circuit protection Yes (protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)
Clip limiter Yes (prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output).
Long term limiter Yes (protects the loudspeaker and amplifier against steady long term rms signals (sine wave, non-music) reducing maximum output) Yes (output power reduction when output stages operating
Thermal protection temperature up to 90 °C (194 °F). Mute when output stages operating temperature up to 100 °C (212 °F)

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

21

REMOTE CONTROL CONNECTIONS ON / OFF No x4 GPIs (0-10V) GPIs Function and settings by embedded web application 5-pin Euroblock connector, rear panel. Euroblock pitch 3,5 mm GPOs x4 NC / NO contacts 4x 3pins Euroblock connector, rear panel Euroblock pitch 3,5 mm
External MUTE Yes, contact (2 pins Euroblock connector, rear panel, Euroblock pitch 3,5 mm)
LOCAL CONTROL Attenuators Programmable Front panel knobs (defaults: Amplified OUTs attenuators)
Output mode settings Lo-Z/Hi-Z, 70V/100V, 4/8/2 Output mode selection per channel (Rear panel DIP SWITCH selectors)
RUN/SLEEP mode Yes, front panel push-button (operate when pressed more than 0,5 seconds)
Power ON/OFF Yes, back panel switch (red LED indicator) CONNECTIVITY
Ethernet Ethernet Base-Tx 10/100/1000Mb Auto X-Over (CAT5 up to 100m. Settings by embedded web application)
DANTETM/ AES67 Protocol DanteTM/ AES67 4x Tx / 4x Rx channels Primary and secondary capability. RJ-45 ports (Settings by embedded web application)
Programming and control Embedded web application MONITORING
Signal Present SP LED (White) per channel (trigger @- 40 dBV) Clipping CLIP LED (Red) per channel (Clip, Versa power limiter, Peak power, Power supply overload) Protect PROT LED (Red) per channel (Current overload, Output short circuit, Under voltage, Over Voltage, DC OUT (slow blink), HF protect (fast blink)
Standby / Mute STBY/MUTE LED (White) per channel (ON when STBY, BLINK when MUTE)
Limit LIMIT LED (Red) per unit (Power (power supply) overload)
Thermal THERMAL LED (Red) per unit (Temperature limiter) DanteTM/ AES67 DANTETM/ AES67 LED (White) per unit (OFF NO WIRE, ON
when MASTER, BLINK when SLAVE) Data DATA LED (White) per unit (ON when DATA)
On ON LED (White) per unit (ON when RUN, SLOW BLINK when SLEEP by BUTTON, FAST BLINK when SLEEP by AUTOSTBY, VERY FAST BLINK when HW Fault)

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
22

Panels APP

Routing GPOs VersaPower Groups Player

DIGITAL ENGINE Processor Quad core 64bits 1,5GHz
AUDIO CONVERTERS Sampling rate 48 kHz Resolution 24 bit
Dynamic range 114dB PROCESSING
Digital processing 32/64 bit Latency 2,8 ms (Analog IN to analog OUT)
Inputs processing Noise gate, HPF, Freq. Shifter, compressor/limiter Outputs processing Delay, Parametric EQ, Graphic EQ independent for every
amp out and aux out. Limiters independent for every amp out Smart VersaPower management (Settings by embedded web application) Preset management, Internal matrix, priority & backup Others signals management, local & network groups, events management incl. calendar (Settings by embedded web application) REAL-TIME CLOCK Retention time > 5 years Accuracy ±1 minute / month Battery VARTA CR2032 3V, 230mAh LOCAL STORAGE Micro SD SDXC Capacity Up to 2TB File system FAT16, FAT 32, VFAT (read/write) NTFS (read) Multi-partition up to 1 Playable audio files mp3, ogg, WAV, FLAC, AIFF Files analysis 65354 playable folders 65354 playable folders within each folder 65354 playable files within each folder Folder hierarchy Up to 8 containing the root directory Sorting UNICODE, in alphabetical order Up to 100 folders / files by folder Folders/files over 100 sorted in the FAT order PHYSICAL Operating temperature -10º to 50º C 14º to 122º F (performance may be reduced above 40 °C) Operating humidity 5 - 85% RH, non-condensing Storage temperature -10º to 50º C 14º to 122º F Storage humidity 5 - 85% RH, non-condensing

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
23

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

Rack 19" installation & desktop Universal Main cords, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19" installation hardware 482.6 x 88 x 410 mm. / 19 x 3.46 x 16.14 inches 9.3 kg / 20.5 lb 650 x 125 x 600 mm. / 25.59 x 4.92 x 23.62 inches 12.3 kg / 27.1 lb

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

7.1.2 VIDA-16Q

VIDA-16Q

INPUTS

Number of Inputs
Analogue input connection type Digital input connection type Input configuration

4 analogue input channels 4 DANTETM/ AES67 Network Rx channels 1 embedded player, 1 embedded signal generator IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm. Ethernet, managed via DanteTM/ AES67 Controller Digital matrix 4 in x 6 out (Settings by embedded web application)

AMPLIFIED OUTPUTS

Number of amplified outputs Amplified output connection type

4 2-pin Euroblock. Pitch: 7,62 mm Ref: DEGSON 5EDGRC-7.62

Output configuration

Lo-Z/Hi-Z, 70V/100V, 4/8/2 Output mode selection per channel Rear panel DIP SWITCH selectors

VERSAPOWER

SYMMETRICAL - All channels driven @1kHz @CF9dB @ 1%THD

Max output power @ 8 Max output power @ 4 Max output power @ 2 Max output power @ 100V Max output power @ 70V

400W 400W 400W 400W 400W

ASYMMETRICAL - Single channel driven @1kHz @CF9dB @ 1%THD

Max output power @ 8 Max output power @ 4 Max output power @ 2 Max output power @ 100V Max output power @ 70V

1400W 1600W 1600W 1600W 1600W

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

24

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

AUXILIAR OUTPUTS Number of auxiliar outputs 2
Auxiliar output connection type AUX1-2: 3-pin Euroblock, balanced (Euroblock pitch 3,5 mm. Settings by embedded web application)
DIGITAL OUTPUTS Number of digital outputs 4
Digital output connection type Ethernet, managed via DanteTM/ AES67 Controller SIGNAL
Voltage gain 28 to 40 dBV 30,2 to 42,2 dBu
Input sensitivity -6 to +6 dBV -3,78 to 8,2 dBu 0,5 to 2 Vrms (adjusted by means of Smart Versa Power utility)
Input impedance >24k (balanced) Max input level +18 dBV +20,2 dBu (@ Gain 34 dBV)
Frequency response 15Hz-25kHz (-3dB, 1W any load) THD + Noise < 0,1 % 0,015 Typ (@ 1kHz, from 0,1W to Full Power) SNR 95 dBA (40dB Gain, from 20Hz - 20kHz) Crosstalk >80dB (@ 1kHz) CMRR > 65 Typ (from 20Hz-20kHz)
Damping factor >500 (@ 8, from 20Hz to 1kHz) ELECTRICAL
Power supply Universal, regulated SMPS with PFC AC mains requirement 100-240 V @ 50-60Hz ((±10%) Power factor correction > 0,96 (Output Power > 500W)
AC mains connector IEC C14 inlet (10Amax) POWER & HEAT @230VAC
1/4 POWER, @ 4 (all channels driven) Power 607 W | 640 VA
Current Draw 3,8 Arms Thermal Loss 178,0kcal/h | 706,5BTU/h 1/8 POWER, @ 4 (all channels driven)
Power 362 W | 414 VA Current Draw 1,8 Arms Thermal Loss 139,3kcal/h | 552,9BTU/h IDLE (all channels driven)
Power 72 W | 122 VA Current Draw 0,52 Arms Thermal Loss 61,9kcal/h | 245,7BTU/h

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

25

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

SLEEP MODE (all channels driven) Power 4,1 W | 23,8 VA
Current Draw 0,1 Arms Thermal Loss 3,5kcal/h | 14BTU/h
POWER & HEAT @120VAC 1/4 POWER, @ 4 (all channels driven) Power 604 W | 611 VA Current Draw 5,17 Arms Thermal Loss 175,4kcal/h | 696,3BTU/h
1/8 POWER, @ 4 (all channels driven) Power 354 W | 362 VA
Current Draw 3,04 Arms Thermal Loss 132,4kcal/h | 525,6BTU/h IDLE (all channels driven)
Power 68 W | 89 VA Current Draw 0,75 Arms Thermal Loss 58,5kcal/h | 232,1BTU/h SLEEP MODE (all channels driven)
Power 3,6 W | 10,2 VA Current Draw 0,09 Arms Thermal Loss 3,1kcal/h | 12,3BTU/h TECHNOLOGIES Amplification technology Class D Energy saving Auto standby function programmable per channel
Sleep Mode function selectable Efficiency 68% (1/4 POWER, @ 4)
Cooling Fan (forced air, front to back airflow. Temperature controlled continuously variable speed)
Maximum fan noise 45dB (maximum acoustical noise @1m) PROTECTIONS
DC protection Yes (protects loudspeaker and installation against DC and infrasonic signals at the outputs)
HF protection Yes (protects the loudspeakers against non-audible, strong, non-musical high frequency signals)
Short-circuit protection Yes (protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)
Clip limiter Yes (prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output).
Long term limiter Yes (protects the loudspeaker and amplifier against steady long term rms signals (sine wave, non-music) reducing maximum output)

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

26

Thermal protection Yes (output power reduction when output stages operating temperature up to 90 °C (194 °F). Mute when output stages operating temperature up to 100 °C (212 °F)
REMOTE CONTROL CONNECTIONS ON / OFF No x4 GPIs (0-10V) GPIs Function and settings by embedded web application 5-pin Euroblock connector, rear panel. Euroblock pitch 3,5 mm GPOs x4 NC / NO contacts 4x 3pins Euroblock connector, rear panel Euroblock pitch 3,5 mm
External MUTE Yes, contact (2 pins Euroblock connector, rear panel, Euroblock pitch 3,5 mm)
LOCAL CONTROL Attenuators Programmable Front panel knobs (defaults: Amplified OUTs attenuators)
Output mode settings Lo-Z/Hi-Z, 70V/100V, 4/8/2 Output mode selection per channel (Rear panel DIP SWITCH selectors)
RUN/SLEEP mode Yes, front panel push-button (operate when pressed more than 0,5 seconds)
Power ON/OFF Yes, back panel switch (red LED indicator) CONNECTIVITY
Ethernet Ethernet Base-Tx 10/100/1000Mb Auto X-Over (CAT5 up to 100m. Settings by embedded web application)
DANTETM/ AES67 Protocol DanteTM/ AES67 4x Tx / 4x Rx channels Primary and secondary capability. RJ-45 ports (Settings by embedded web application)
Programming and control Embedded web application MONITORING
Signal Present SP LED (White) per channel (trigger @- 40 dBV) Clipping CLIP LED (Red) per channel (Clip, Versa power limiter, Peak power, Power supply overload) Protect PROT LED (Red) per channel (Current overload, Output short circuit, Under voltage, Over Voltage, DC OUT (slow blink), HF protect (fast blink)
Standby / Mute STBY/MUTE LED (White) per channel (ON when STBY, BLINK when MUTE)
Limit LIMIT LED (Red) per unit (Power (power supply) overload)
Thermal THERMAL LED (Red) per unit (Temperature limiter) DanteTM/ AES67 DANTETM/ AES67 LED (White) per unit (OFF NO WIRE, ON
when MASTER, BLINK when SLAVE) Data DATA LED (White) per unit (ON when DATA)

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
27

Panels APP

Routing GPOs VersaPower Groups Player

On ON LED (White) per unit (ON when RUN, SLOW BLINK when SLEEP by BUTTON, FAST BLINK when SLEEP by AUTOSTBY, VERY FAST BLINK when HW Fault)
DIGITAL ENGINE Processor Quad core 64bits 1,5GHz
AUDIO CONVERTERS Sampling rate 48 kHz Resolution 24 bit
Dynamic range 114dB PROCESSING
Digital processing 32/64 bit Latency 2,8 ms (Analog IN to analog OUT)
Inputs processing Noise gate, HPF, Freq. Shifter, compressor/limiter Outputs processing Delay, Parametric EQ, Graphic EQ independent for every
amp out and aux out. Limiters independent for every amp out Smart VersaPower management (Settings by embedded web application) Preset management, Internal matrix, priority & backup Others signals management, local & network groups, events management incl. calendar (Settings by embedded web application) REAL-TIME CLOCK Retention time > 5 years Accuracy ±1 minute / month Battery VARTA CR2032 3V, 230mAh LOCAL STORAGE Micro SD SDXC Capacity Up to 2TB File system FAT16, FAT 32, VFAT (read/write) NTFS (read) Multi-partition up to 1 Playable audio files mp3, ogg, WAV, FLAC, AIFF Files analysis 65354 playable folders 65354 playable folders within each folder 65354 playable files within each folder Folder hierarchy Up to 8 containing the root directory Sorting UNICODE, in alphabetical order Up to 100 folders / files by folder Folders/files over 100 sorted in the FAT order PHYSICAL Operating temperature -10º to 50º C 14º to 122º F (performance may be reduced above 40 °C) Operating humidity 5 - 85% RH, non-condensing

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
28

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

-10º to 50º C 14º to 122º F 5 - 85% RH, non-condensing Rack 19" installation & desktop Universal Main cords, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19" installation hardware 482.6 x 88 x 410 mm. / 19 x 3.46 x 16.14 inches 9.3 kg / 20.5 lb 650 x 125 x 600 mm. / 25.59 x 4.92 x 23.62 inches 12.3 kg / 27.1 lb

7.2 MECHANICAL DIAGRAM 7.2.1 VIDA-24Q

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

29

7.2.2 VIDA-16Q

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

3 0

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8. WebGUI
VIDA series digital amplifiers are configured and controlled through their embedded web application. The user interface can be operated via any web browser on any device: Windows, MacOS, Tablet or Smartphone1.
ECLER VIDA is the user application that allows control of one or more VIDA series amplifiers on the same local network through customised user control panels set up by the system administrator. The app gives allows users to control volume, select sources, equalise, select playlists, control the internal audio player, select presets, and more. Exclusive panel for each user, fast and straightforward to create. There is also a tool for the administrator to start up the equipment for the first time.
Compatible with Ecler VIDA series amplifiers. An Ecler VIDA series amplifier is required to create user panels and publish them on the local network.
Available for iOS and Android. Download the app free from:

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

We recommend updating your browser to the latest version to ensure that the app functions correctly.
Demo version available. Visit www.vida.ecler.com and access the VIDA application online ­ physical connection to a VIDA device is not required ­ and explore the capabilities of these devices. Note that some functionalities, such as firmware update, will not be available and require a physical connection to a VIDA device.
1Web application not optimised for Smartphone. We recommend using on PC or Tablet.
31

8.1 UPDATES
· Current version: V1.03 (December 2023): o Support for VIDA-48Q model. o Back-up copies compatible with various models. o TP-NET support for input selection ("zoner" mode). o Group volumes saved in presets. o Possibility to select "None" as the input of a source. o French, Portuguese and Galician languages have been added. o Unique language list. o Bug fixing and improvements o NIMBO-24 EQ upgrade. o Secondary signal display in mixer/zoner is hidden when it does not exist. o Fixed auto-update when in boot mode. o Fixed bug where group volumes could not be loaded from a backup. o Adaptability of combos selection to content has been improved. o Some minor bugs fixed.
· Previous versions: o V1.02 (July 2023):  Support for VIDA-16Q model.  AES67 support.  User EQ settings management has been added, allowing saving, editing and deleting EQ curves.  The option to import and export user EQ settings has been added.  Added factory EQ setting for NIMBO-24.  Improvements and TP-NET support of the impedance monitor.  The administrator can now reorder the controls in the user panels.  When the auxiliary IP is active, it is now also displayed on the STATUS page.  Language selection has been added to the user application.  Italian and Basque have been added.  Improvements and bug fixes · The audio player continues playback after the equipment has been switched off. · Review of templates. · Manual refresh of the contents of the microSD card. · The configuration files now belong to each model. · Latency error corrected between the amplified and auxiliary outputs. · Possible connection error corrected when connecting point-to-point equipment via auxiliary IP.

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
32

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Other minor errors corrected.
o V1.01 (April 2023):  Spanish and Catalan added.  Stereo output link added to limiters.  Fixes in Net Groups that were causing malfunction.  Automatic management of stereo outputs in Net Groups.  Fix in Calendar Monitoring for a bug when creating an event in the past.  Improved management of network activity events (logs).  Amendment of some texts in Events for clarity.  Major improvements to Impedance Monitor  Change in Health: Health Monitor and the list of errors and recovered errors are independent. Daily health events list displayed.  Fix in logs, which might have caused detection of a system error.  Correction to configuration of delay scale, which might have caused adjustment control to disappear.  Minor bug fixes and performance improvements.
o V1.00 (April 2023):  Official release version of VIDA-24Q.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

33

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.2 FIRST STEPS
To access the VIDA web application from an external device (computer, tablet, etc.) using a browser, first make sure that both devices are physically connected to the same local area network (LAN), and configured within the same network range.
DHCP is the default network configuration mode. If you have a router/switch with a DHCP server (see the specifications for your device), network configuration is automatic so there is no need for you to do any re-configuration.
There are 3 ways to connect to the embedded VIDA web application:
8.2.1 AUTOMATIC CONNECTION USING THE ECLER VIDA USER WEB APP
1. Download the Ecler VIDA app from the app store for your device. 2. Connect the VIDA device to the router/switch using a CAT5 or higher cable (NET1
Ethernet port on the VIDA device) 3. Connect your Smartphone to the same local network as the VIDA device over
WiFi. 4. Open the app and click on "Setup Device". Follow the instructions. 5. A list of all VIDA devices on the network will be shown. When you click on a listed
device, you can see further information and its web connection and IP address. 6. Copy one or more links and paste them into your browser, on the same or another
device.
8.2.2 AUTOMATIC CONNECTION USING A COMPUTER
1. Connect the VIDA device to the router/switch using a CAT5 or higher cable (NET1 Ethernet port on the VIDA device)
2. Connect your browser-equipped device (computer, tablet, etc.) to the same local network (router/switch). You can do this over a wired or WiFi connection, depending on your network device and computer/Tablet.
3. Check the label on the back panel or the additional label in the packaging, and enter the web address shown here (http://vida-24q-xxxx.local) into your browser. The last 4 digits of the web address are the same as the MAC address of the device.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

34

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4. Enter that address in your browser.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Another way is to find out the IP address for the device via the internet or your router/switch's settings if you can access them using the Ecler VIDA user app. 8.2.3 MANUAL CONNECTION If you do not have a DHCP server, don't know whether you have one, or just want to make a point-to-point connection with a computer:
1. Connect the VIDA device to the computer using a CAT5 cable or higher (NET1 Ethernet port on the VIDA device).
2. If no DHCP server is found the VIDA device can be accessed via IP address: 192.168.0.100. Localise your computer in the same IP range to access the device.
3. Enter the IP address 192.168.0.100 in your browser.
35

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.3 LOGIN

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

There are 2 profiles that can access the app
1. Administrator: An administrator has access to all functions of the VIDA device and can configure any amplifier parameter, event, peripherals, etc. An administrator creates users and control panels for the Ecler VIDA user app.
2. User: users (non-administrator users or end-users of the system) have limited access. The only functions available to normal users are controls (e.g. controlling the volume of an output) but no configuration functions.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

36

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

Administrator and user access are password-protected. The default administrator access credentials are:
· Username: admin · Password: admin
An administrator can change their access password in the VIDA web app and manage users and passwords.
Usernames and passwords are case-sensitive.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

8.3.1 KEEP ME LOGGED IN
When this function is active, a new login will not be required each time the VIDA web app is opened. The LOGIN page will not be displayed and the last page visited will be displayed. To deactivate, log out of the web app.

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

8.3.2 FORGOT PASSWORD Allows users to change their password and the administrator to restore login credentials (name and password) if forgotten. To reset the administrator credentials, enter them in the Reset Passwords dialogue box:
· User name: admin · Password: reset
Administrator access credentials will be restored to the default values: admin/admin.

8.3.3 PUBLIC PANELS
Access to control panels, public profile (no login credentials required). These control panels must be created by an administrator. See Panels chapter for more details on public control panels.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

37

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.3.4 SETUP DEVICE Quick start-up and/or discovery of VIDA devices on the same local network.
To set up an installation with several VIDA devices, access the web app of any of those devices and use Setup Device to find the network information for the others and access them easily.
8.4 NAVIGATION The app screen has 3 parts.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. App bar: contains important information, quick action buttons and the app configuration menu.
2. Main menu: contains the different configuration pages. 3. Page: Displays all configuration options within the chosen menu option. A menu
entry may contain different tabs with different pages.
38

8.4.1 APP BAR 1 2
3 4

Web HW GUI
Expand or collapse main menu
Management of user presets: · Load: opens a window in which you have to select the preset you want to load. · Save: saves the settings in the current preset. · Save as: opens a window to save the settings in the preset selected. It can be given a name. · Presets for panels: the presets selected in the window will be available to users. They can be uploaded from a control panel. · Import: allows you to import a preset from your computer.
· Export allows you to export/download a preset to your computer.
Presets are settings for Routing, GEQ and GPO status. Only changes to these settings will be uploaded or saved, the settings for individual Device cannot be changed.
Device name: name of the device. By default, the last 4 digits of the MAC (NET1) are shown.
You should not give the same name to more than one device on the same local network. Duplicate names could cause conflicts on the network and cause malfunction in the network functions of a device.
Power saving mode activated (Sleep Mode). When power saving is activated, pressing the button opens a window that allows exit from power saving mode.
Power saving mode deactivated (Running Mode). The device is in operation.
39

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

5

Panic button activated: mutes all outputs.

Panic button deactivated.

Web HW GUI

PRECAUTIONS

6

Undo and redo buttons.

7

Full screen.

Exit full screen.

PACKAGE CONTENTS

8

Help menu.

DESCRIPTION & FEATURES

9

App menu:

· UI Scale: set the display size for the GUI.

· Language: GUI language selection.

· Mini Player: opens/closes the mini player in the lower bar.

· Service: reserved for authorised personnel.

· About: displays information about the web app.

· Logout: exit the app.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

40

8.5 SETTINGS This is where to configure the general settings for the device.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

· Device · Network. · Knobs/GPIOs · Energy Saving · Health · Backup and Firmware.
4 1

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

8.5.1 DEVICE General settings.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Device · Device name: The name is used to identify the device on the network (NET1 and NET2), and identifies it as a DanteTM/ AES67 device, as well as mDNS (to resolve hostnames to IP addresses). The info button shows the requirements for a DanteTM/ AES67 name. · Web Access: access to the configuration web page using the device name. Copy and paste the address into your browser to open a new instance of the web app. · Group ID: Identifying name of the group of VIDA amplifiers on the same local network. Amplifiers with the same group name can use the same Net Groups. There can be the same number of Net Groups (up to four Net Groups) on a network as there are Group IDs on the network. · Comments: space for comments and notes about the amplifier, installation, configuration, etc.
42

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Time & Date · Time & Date: time and date on the device. · Time Zone: selection of time zone. · Date Format: date format. · Week starts on: first day of the week. · NTP Synchronization: enables or disables time synchronization with NTP server. Internet connection required. Enable this functionality for automatic time synchronization on the device. · NTP server: address of the NTP server.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

DESCRIPTION & FEATURES

3. Boot-Up · Reboot device: reboot the device. The device will keep its current configuration on reboot. · Restore defaults: reverts to factory settings.
The current network configuration and device name will be lost. May cause disconnection of the device from the local network.
· Boot-up mode: selects the mode in which the device starts after shutdown: · Remember: starts up with the configuration at shutdown. · Load: allows you to select the preset for device start-up.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

43

8.5.2 NETWORK Device network settings and search function.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. VIDA devices have 2 RJ-45 Ethernet connectors on the rear panel. Each is for an independent network interface. · NET 1: network interface for monitoring. Communication with web app, user control application and third party integration protocol. The option if DanteTM/ AES67 digital audio send and/or receive is not used. · NET 2: Network interface for control and DanteTM/ AES67 digital audio send and receive. DanteTM/ AES67 digital audio, communication with web app, user control app and third party integration protocol. The option if you use DanteTM/ AES67 digital audio send and/or receive.
The NET 1 and NET 2, networks can be configured independently. They can be connected and operate simultaneously, for example, to isolate DanteTM/ AES67 digital audio traffic from other traffic on the network.
If the NET 1 and NET 2 networks are used simultaneously, they should be configured so that they are on different networks. If the NET 1 and NET 2 networks are connected on the same local network, network conflicts may arise that impact network functionality.
44

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

Network cable not connected.
Network cable connected.
Button that opens settings for network parameters. Shows IP addressing:
· Auto (DHCP): automatic addressing. DHCP server required. Default value.
· Manual: manual addressing.
Network parameter factors: · If NET 1 is configured as Auto (DHCP), and there is no DHCP server, it will automatically be configured with an auxiliary IP addressed and can be accessed via: 192.168.0.100. Use that address if you are connecting point-to-point with a computer. · If the NET 1 and NET 2, networks are connected, access to the Internet will be through the Gateway of NET 1 and NET 2 will have a display value of 0.0.0.0. · The DNSs of NET2 are the same as the NET 1 DNSs when both networks are connected.
2. Finder: Function to distinguish the device from other devices in the same location.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

When the Finder function is enabled, the front panel LEDs will flash for 60 seconds. It is then automatically deactivated.

3. Internet Connection: Internet connection check.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

45

8.5.3 KNOBS/GPIOS Configuration of front panel potentiometers, GPIs and GPOs.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Knobs Allows individual configuration of the rotary controls on the front panel:
· Label: label, for easy identification. The label has to be different for each of the four potentiometers.
· Status: indicates the status of a potentiometer or GPI. Values are in the range 0 (minimum)-100 (maximum). GPOs show the values open or closed.
46

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. GPIs Allows individual configuration of the rear panel GPI ports:
· Label: label, for easy identification. It must be unique for each GPI. · Mode: Analogue or digital mode:
o Analogue: Analogue for volume control. Rotary controls 0-10VDC. o Digital: for actions like signal muting, loading presets or playlists, activating
GPO and Play/Pause. Buttons, push buttons, contact closures. · Calib. (GPI calibration):
o Place the potentiometer at the end where it gives a minimum reading. Read the Status value and set the minimum value of the "Calib" control to the same value.
o Place the potentiometer at the end where it gives a maximum reading. Read the Status value and set the maximum value of the "Calib" control to the same value.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

3. GPOs Allows individual configuration of the rear panel GPO ports:
· Label: label, for easy identification. It must be unique for each GPO. · Mode: Preset or event mode.
o Preset: the active or inactive status of the GPOs is stored in the Presets, so that recovering one of them recovers the combination of active/inactive GPOs at the time of saving. GPOs configured as preset GPOs are not available for modification via events.
o Event: The active or inactive status of GPOs is determined by events. GPOs configured as event GPOs are not available for modification via presets.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

47

8.5.4 ENERGY SAVING
The VIDA series performs a fully programmable energy saving function that reduces energy consumption by up to 95%, which can help save money.

Web HW GUI

See below for the different types of amplifier power saving mode settings.

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Sleep Mode VIDA amplifiers have an energy saving mode where power draw is very low.

· Amplifier status: shows the current status of the amplifier:

o Running: normal operation.

o Sleeping: sleep or power-saving mode. The amplifier can enter powersaving mode in 2 ways:

 Manual: by pressing the ON button on the front panel, or via internet

configuration with the "power" button

on the STATUS page.

 Automatic: by activating Auto Sleep Mode.

48

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Auto Sleep Mode: When activated, the amplifier will enter power-saving mode (Sleeping) when all 4 amplified outputs are in Standby and will automatically return to normal operation (Running) when: o An amplified output is not in Standby mode. o The button on the front panel is pressed. If enabled. o The "Power" button on the STATUS page is pressed. o An event or user control causes one of the amplified outputs to exit standby.
The digital inputs and outputs are disabled when the device is in power-saving mode.
If any of the analogue inputs carries an audio signal, even if not assigned to a Source, the device will remain operational and will not enter power saving mode.
· Front Panel On/Sleep Button: Enables or disables the ON/SLEEP button on the front panel to prevent unwanted operation.
To switch the device off completely, use the "Power" button on the rear panel.
2. Auto Standby Configuration of auto standby for amplified outputs independently. · Enable: enables/disables the auto standby function for the output. · Threshold: standby activation threshold setting. · Time: waiting time.
For an output to enter standby, the audio signal at the output must remain below the specified threshold for the specified time.
If any of the outputs have auto standby disabled, the Auto Sleep function will not work properly. Auto standby must be enabled on all 4 amplified outputs.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

49

8.5.5 HEALTH Amplifier health monitor.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Health Monitor: Summary of the amplifier's health status: · OK: everything is OK. There are no errors or if there were, they have been resolved. · Warning: attention is required, an error has occurred.
2. List of daily incidents: shows errors, recovered errors, warnings and system failures that have occurred since 00:00.
The health monitor reports system errors (failures), which could lead to a major failure of the device, i.e. warnings for overvoltages, temperatures, etc. The event list, in addition to system errors, shows a list of errors and warnings related to the configuration of the device, that are not a major failure of the device, but may lead to a malfunction.
· The health monitor may indicate that all is well, and at the same time display errors and warnings in the event listing. This means that the health of the system is not compromised, but that there may be causing a malfunction. For example, an Internet connection fault is causing the firmware not to update automatically.
· The health monitor may indicate that the device requires attention and at the same time not display any errors or warnings. This means that a failure that compromises the health of the system occurred before 00:00. Please view the log for more information.
50

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. Amplifier monitor: The monitor displays the most important amplifier output parameters and has an in-built impedance monitor. · Voltage (RMS): RMS voltage, in volts. · Current (RMS): RMS current, in amperes. · Power (RMS): RMS power, in Watts. · Z-Switch: position of the rear panel impedance selector. · Impedance: value of the impedance at the output, in ohms. · Z-monitor: enables impedance monitoring at the output. If enabled, an error notification will be sent when the impedance exceeds the set thresholds or a short-circuit or open-circuit situation occurs. This functionality is also available via TP-NET, to communicate the status of the amplifier line to third parties (see chapter TP-NET Protocol for details): o Z-min: lower impedance threshold. o Z-max: upper impedance threshold.
The impedance monitor is an informative tool. The protections against overcurrent situations in the amplifier are always enabled (PROTECT), regardless of whether the impedance monitor is enabled or not.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

An indicator in the upper right corner of each amplifier shows its output status:
· STBY: output on Standby. · 0W: output set to 0 W in Smart VersaPower. · EXTM: output affected by GPI External Mute. · NETM: the output belongs to a network group
that is muted. · LOCM: the output belongs to a local group that is
muted. · GENM: the output belongs to the general volume
group that is muted. · MUTE: the output is muted in the audio matrix.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

51

8.5.6 BACKUP AND FIRMWARE
Upload and download of configuration files and backups and update of amplifier firmware.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Backup Management A backup is a security copy or configuration file of the device. A replica of the status and configuration of the amplifier.
· Export backup file: saves a backup copy of the amplifier on the device that is running the app (e.g. computer).
· Import backup file: upload a backup file to the amplifier from the device that is running the app (e.g. computer).
· Load Template: loads a template. A default configuration and status for quick start-up.
Templates do not change network parameters or device settings (Settings/Device).
When a configuration file is uploaded(backup), all device parameters, including network parameters, are overwritten. Care must be taken when uploading a configuration file because access to the web app may be lost.
The configuration files are unique to each model. So a configuration file of a particular model of the VIDA series cannot be loaded into another model of the series.
52

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Firmware Management · Reports the current firmware version of the amplifier and management of firmware updates.
· Current Firm. Version: current version of the device. · Last update: date of the last update. · Check update: check online for recent updates. · Manual update: manual update · Automatic update: if enabled, the device will be updated automatically:
o Boot-up: check if there is an update at each start-up. If an update is available, it will be installed.
o Scheduled: scheduling the checking of updates. It will check whether there is an update at the specified interval if the device is in operation. If an update is available, it will be installed.
The automatic firmware check and update require an Internet connection.
It is recommended to schedule firmware updates outside the normal working hours for the device.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

53

8.6 STATUS Overview of amplifier status, display and control of basic parameters.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. General · Health: summary of the health status of the device. · Network: summary of the network configuration. · Device: model and firmware version of the device. · Time/Data: time and date of the device. · Power: ON/Sleep button.
2. Monitor Hardware · The button on the right shows the hardware monitor view and display a replica of the front panel and the status of the hardware connected to the device.
· A. Indicators for presence of signal (signal), saturation (clip), protection (prot),
standby (stby) and mute for each amplified output and the value set on the front panel rotary control.
54

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

B. Indicators for limiter (limit), thermal protection (thermal), DanteTM/ AES67 activity, network activity (data) and amplifier operation (on).
C. GPIs: indicates the reading values for the GPI and GPOs: shows the status of the GPO, open or closed. If greyed out, it means that the GPO is event-driven and if lit, it means that it can be changed via presets.
D. The button on the right returns to the overview.
For more information on the front panel of the amplifier, see chapter Functions Panels.
3. Signal monitor 3.1 The top selector allows you to change which signals are displayed. 3.2 Display and control of a signal. The picture is different depending on the group selected but all have the same layout.
· Label: to distinguish it from other signs. Clicking on Label takes you to the configuration page.
· Volume and VU meter for the signal. · Source selected: clicking in a source takes you to the signal routing page. · Impedance selector monitor: shows the impedance selected on the
commutator on the rear panel.
For safety reasons, the selected impedance cannot be changed via the web app: because an unwanted change to impedance could harm the equipment.
An indicator in the upper right corner of each amplifier shows its output status:
· STBY: output on Standby. · 0W: output set to 0 W in Smart VersaPower. · EXTM: output affected by GPI External Mute · NETM: the output belongs to a network group
that is muted. · LOCM: the output belongs to a local group that
is muted. · GENM: the output belongs to the general
volume group that is muted. · MUTE: The output is muted in the audio matrix.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

55

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.7 ROUTING
Signal routing for the amplifier.
The routing of the amplified and auxiliary outputs is independent, and can be configured as follows:
· Mixer: allows the mixing of several sources in the same output. Outputs configured as a mixer will appear in the Mixer/Matrix window.
· Zoner: allows the routing of sources. It is not possible to mix sources on the same output; however, a source selector is built into each output. Outputs configured as zoners will appear in the Zoner window.
Configurable matrix:
· 4x6: 4 input sources, 6 outputs (4 are amplified outputs - OUT - and 2 are auxiliary outputs - AUX-).
· 4x4: 4 input sources, 4 amplified outputs (amplified outputs configured as mixer, auxiliary outputs configured as zoner).
· 4x2: 4 input sources, 2 auxiliary outputs (amplified outputs configured as zoners, auxiliary outputs configured as mixers).
The digital outputs always operate in zoner mode as an audio signal router.
In VIDA, there are several types of input signals:
· 4x Analogue inputs: balanced line inputs. · 4x Digital inputs: DanteTM/ AES67 digital audio inputs. · 1x Audio player. · 1x Signal generator.
A Source is the combination of two input signals, a primary and a secondary signal. There can be no secondary. In VIDA, 4 independently configurable sources are available. Sources are the input signals to the audio matrix (mixer mode) or the sources available on the router (zoner mode).

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

56

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

1. Mixer/Matrix Matrix view selector:

Single view / Full view.

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Mixer View

Crosspoint section for the selected output. It takes on the colour assigned to the corresponding output. From top to bottom:

· Source Label.

· Pri: input_n / Sec: input_m, primary and secondary source signals. The signal currently on the source is illuminated.

· Crossover point volume control and VU meter.

Control + click on a fader to reset to default value (0dB).

· Enable/disable the crossover point at the output. Sources with the crossover point enabled are mixed at the corresponding output.

The VUs change colour depending on the signal level: · Green: below 0dB. · Orange: 0-18dB (headroom). · Red: clip, above 18dB, signal saturation.

57

Panels APP

Users Register TP-NET Protocol

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Output selection section. From top to bottom:
· Output Label.
· Status LEDs:
o STBY / MUTE: shows the standby status of the output (if amplified) and whether it is affected by any group or external MUTE.
o LGRP: local group indicator. If lit, it means that the output belongs to at least one local group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
o NGRP: Network Group Indicator. If lit, the output belongs to at least one network group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
o Volume control for the output and VU meter.
o MUTE button, to mute the output.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

STBY indicator: · STBY: output on Standby. · 0W: output set to 0 W in Smart VersaPower. · EXTM: output affected by GPI External Mute. · NETM: the output belongs to a network group that is muted. · LOCM: the output belongs to a local group that is muted. · GENM: the output belongs to the general volume group that is muted. · MUTE: The output is muted in the audio matrix.
If both outputs are in Mixer mode, the AUXs button appears and shows the mixer window for the auxiliary outputs.
The OUTs button on the auxiliary output mixer returns to the mixer for the amplified outputs.
58

Matrix View

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Audio sources. When an audio source is selected, its information and control are displayed on screen. · Source Label (Source). · Pri: input_n / Sec: input_m, primary
and secondary source signals. The signal currently on the source is illuminated. · Volume control for the source with volume meter. · MUTE button, to mute the source.
Audio outputs. When an audio output is selected, its information and control are displayed on the screen.
59

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Output section. From top to bottom:
· Output Label.
· Status LEDs:
o STBY / MUTE: shows the standby status of the output (if amplified) and whether it is affected by any group or external MUTE.
o LGRP: local group indicator. If lit, it means that the output belongs to at least one local group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
o NGRP: Network Group Indicator. If lit, the output belongs to at least one network group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
· Volume control for the output and VU meter.
· MUTE button, to mute the output.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Crossover points. When a crossover point is selected, its information and control are displayed on the screen, as well as the information and control for the source and output for that crossover point

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

60

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Crossover point volume control and VU meter.
· Enable/disable the crossover point.
Double click on a crossover point to enable/disable it.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Crossover point disabled
Crossover point enabled
2. Zoner Outputs configured as Zoner.
A group of outputs (OUTs or AUXs) configured as a Zoner are not available in the Mixer/Matrix tab.
Audio outputs, top to bottom: · Output Label.
· Source selector: for selection of source for the output.
· The Auxiliary outputs as well as the 4 sources allow audio signal to be redirected to amplified outputs.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

61

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Post/pre fader control. o If the post fader is enabled, the signal is sent to the output after processing and after the fader for the selected input signal. · If the post fader control is disabled, the signal is sent to the output after processing or afterwards (selectable by the post DSP control) and prior to the fader for the selected input signal.
· Status LEDs: o STBY / MUTE: shows the standby status of the output (if amplified) and whether it is affected by any group or external MUTE. Exclusive for amplified outputs. o LGRP: local group indicator. If lit, it means that the output belongs to at least one local group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there. o NGRP: Network Group Indicator. If lit, the output belongs to at least one network group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
· Volume control for the output and VU meter.
· MUTE button, to mute the output.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

62

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. Services
Routing of DanteTM/ AES67 digital audio outputs.
Digital audio outputs, top to bottom:
· Output Label. · Post/pre fader control.
o If the post fader is enabled, the signal is sent to the output after processing and after the fader for the selected input signal.
o If the post fader control is disabled, the signal is sent to the output after processing or after (selectable by the post DSP control) and prior to the fader for the selected input signal.
· Status LEDs: o LGRP: local group indicator. If lit, it means that the output belongs to at least one local group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there. o NGRP: Network Group Indicator. If lit, the output belongs to at least one network group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there.
· Volume control for the output and VU meter. · MUTE button, to mute the output.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

63

8.8 EQ (EQUALIZER) Graphical user equaliser.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Independent 8-band graphic equaliser (GEQ) for each amplified and auxiliary output. · The GEQ settings for each output can be saved and recalled via presets. · It can be added as an equalisation control in the user panels, per output.
Enables or disables (bypasses) GEQ for the selected output.
· Changes made to the GEQ are applied in realtime.
· If GEQ is disabled on an output, it cannot be edited.
Output selection: the selected output is larger and brighter than the others.
64

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

GEQ preset selection.
If any of these settings of these settings is changed it is displayed in the GEQ as "custom", to indicate a custom setting.

Web HW GUI

PRECAUTIONS

Adjusting gain for the GEQ bands.
· Adjust between positive 12dB and negative 12dB.

PACKAGE CONTENTS

DESCRIPTION & FEATURES

INSTALL & CONNECT

· Pre-GEQ level indicator.
· GEQ level adjustment: positive 12dB to negative 12dB.
· Post-GEQ level and post-level adjustment indicator(GEQ-Vol).

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

65

8.9 GPOS Status of contact closures, GPOs.
The status of the GPOs (open/closed) on this page can be saved and retrieved via presets.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. GPO configured as an event GPO. · The status of the GPO is event-driven. · Its status cannot be changed from this page so that a particular state cannot be retrieved via presets.
2. GPO closed. 3. OpenGPO .
66

8.10 IO SETUP (INPUT AND OUTPUT SETUP) Configuration of inputs and outputs for an amplifier.
8.10.1 INPUTS SETUP Adjustment of the audio inputs available on an amplifier.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Analogue inputs Adjustment of the 4 balanced analogue line inputs.
· Label: label for an input. · Trim: digital gain adjustment, 0-12dB. · Level: adjustment of signal level, mute and VU. · Mode: selection of mono or stereo mode. · Polarity: selection of the polarity of the signal.
Stereo signals:
· Only adjacent signals can be configured as a stereo pair. · The odd signal configuration will be applied to the stereo pair. · When undoing stereo, the odd signal keeps the stereo pair configuration and
the even signal has the configuration it had in mono. · A stereo pair is displayed as a single input/output. · The amplifier performs the routing of a stereo signal automatically. Like this: if
a stereo signal is sent to a mono output, the stereo sum will be sent; and if a mono signal is sent to a stereo output, the same signal will be sent to both outputs.
67

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Digital inputs Adjustment of the 4 DanteTM/ AES67 digital audio inputs. The DanteTM/ AES67 Controller app is required for the configuration and routing of DanteTM/ AES67 audio signals.
· Label: label for an input. The information icon shows how to create labels compatible with the DanteTM/ AES67 Controller app.
· Trim: digital gain adjustment, 0-12dB. · Level: adjustment of signal level, mute and VU. · Mode: selection of mono or stereo mode. · Polarity: selection of the polarity of the signal.
3. Player Internal audio player settings. · Label: label for an input. · Level: adjustment of signal level, mute and VU.
The player's signal is stereo.
4. Generator Signal generator settings, for testing and adjustment during commissioning of the AV system. · Label: label for an input. · Signal Type: selection of test signal type. · Frequency: selection of the frequency of the test signal. Available when a Sine type signal is selected. · Level: adjustment of signal level, mute and VU.
The generator signal is mono.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

68

8.10.2 SOURCES SETUP Adjustment of the amplifier's audio sources.
A Source is the combination of a primary input signal and a secondary (optional) input signal.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

· Label: label of the source. · Prim. Input: selection of the primary input signal. · User Range Volume limits set by the user via user panels. · Sec. Mode: operating mode of the secondary signal
o Priority: the secondary signal has priority. The secondary signal will be swapped with the primary signal when a signal is detected on the secondary signal.
o Backup: the primary signal has priority. The secondary signal will be swapped with the primary signal when no primary signal is detected.
· Prim./Sec: If this function is enabled, the priorities defined in this section are set. · Now playing: indicates the signal present at the source (primary or secondary). · Priority: configuration of a source with a secondary priority signal.
69

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

The secondary signal will be exchanged with the primary signal, when the secondary signal exceeds the set threshold(Sec. Threshold). When the secondary signal is again below the threshold, for the time set (Hold), the primary signal will again be present at the source.
Select a higher Hold time to extend the priority time window. For example, in a spoken message pauses cause the primary signal to return.
· Backup: the secondary signal will be swapped with the primary signal, when the primary signal is below the set threshold (Prim. Threshold), and held for the specified time (Hold). When the primary signal is again above the threshold, the primary signal will again be present at the source.
Select a higher Hold time to extend the time window before input of the backup signal to the source. For example, in a music programme with high dynamic range some passages cause the secondary signal to be introduced.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

70

8.10.3 AMP & AUX OUTS SETUP Adjustment of the amplified outputs and auxiliary outputs of the amplifier.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Output routing: selection of the routing mode for the amplified and auxiliary signals .
· Mixer o Allows mixing of several sources on the same output. o Control of level of sources, crossover points and outputs. o Outputs configured as a mixer will appear in the Mixer/Matrix window.
· Zoner o Allows routing of sources. o It is not possible to mix sources on the same output. o Source selector on each output. o Allows you to manage the level of outputs. o Outputs configured as zoners will appear in the Zonerwindow.
71

o
2. Amplified Output: settings for the 4 amplified outputs .
· Label: output label. · Gain: Amplifier gain at the output.
o Disabled: option disabled if the Smart VersaPower function is enabled.
o Gain options.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

If the Smart VersaPower tool is not used, use the limiters available in the processing section to not damage the equipment.
· User Range. Volume limits set by the user via user panels. · Mode: selection of mono or stereo mode. · Polarity: selection of the polarity of the signal. · HPF: selection of the high-pass-filter frequency. Always
enabled when the output is configured as 100/70 V line output. · Colour: allows assignment of a colour to an output.
Related events
Outputs can be controlled by events, either physical controls (rotary controls, GPIs...), virtual controls (panels) or automations (calendar events).
If any outputs are associated with an event, the following automatic settings are made when switching mono or stereo mode:
· Mono to stereo output: Events related to the odd output are maintained, with the stereo pair configured as the event output. Events related to the even output are maintained, with no output assigned. Stereo to mono output: Events related to the stereo pair are maintained, with the odd output configured as the event output. Does not apply to even output.
We recommend reviewing event configuration when there is a configuration change on the outputs (mono to stereo, or stereo to mono) and the outputs have associated events.
3. Auxiliary Outputs: settings for the two balanced auxiliary line outputs .
72

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

· Label: label for the output. · User Range Volume limits set by the user via user panels. · Mode: selection of mono or stereo mode. · Polarity: selection of the polarity of the signal. · Colour: allows assignment of a colour to an output.

Web HW GUI

PRECAUTIONS

8.10.4 DIGITAL OUTS SETUP Adjustment of the 4 DanteTM/ AES67 digital audio outputs.
The DanteTM Controller app is required for the configuration and routing of DanteTM audio signals.

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

· Label: output label. The information icon shows how to create labels compatible with the DanteTM/ AES67 Controller application.
· User Range: Volume limits set by the user via user panels. · Mode: selection of mono or stereo mode. · Polarity: selection of the polarity of the signal. · Colour: allows assignment of a colour to an output.
73

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.11 VERSAPOWER
VersaPower is the amplifier technology developed by Ecler which allows asymmetrical power distribution between the amplified outputs, independent of the load.
The Smart VersaPower tool allows you to limit the maximum power delivered at each amplified output and adjust gain automatically. The maximum power of the amplifier can be distributed asymmetrically between the outputs.
Specify the sensitivity of an audio input and set the desired maximum RMS power for each amplified output.
The sum of the maximum RMS power for the four amplified outputs (Total power used) may not exceed the maximum total power of the amplifier.
Enabling Smart VersaPower disables the gain adjustment in the IO Setup section for the outputs..
Smart VersaPower is enabled by def0ault, configured as a symmetrical amplifier, 4x600W, for inputs with 0dB sensitivity.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Smart VersaPower configuration Enables/disables the Smart VersaPower tool.
When enabled, it can be reconfigured. By default, it is enabled. If disabled, note that the gain setting for the outputs will return to the value before Smart VersaPower was enabled. That is, 34dB for each output if unmodified (default values).
74

2. Calculate: Button for resetting the Smart VersaPower settings. Button available if Smart VersaPower is enabled. The button opens a window to reconfigure the parameters.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

A. Configuration of parameters for an output: · Impedance selector indicator on the rear panel, to display the status of the impedance selector. · Sensitivity: selection of the sensitivity of the input signal to the amplifier. · Max RMS Power: setting of the maximum power delivered by an amplified output. The value must be between 0 W and the maximum power of the amplifier. The sum of the power of the 4 outputs may not exceed the maximum power of the amplifier.
B. Indicates the power used across the 4 channels. C. Cancel: cancels the configuration. Smart VersaPower will remain disabled and no
changes will be applied. Apply: applies the changes made to the Smart VersaPower configuration. If there is an error, e.g. exceeding the maximum power, it will not let you continue.
3. VersaPower Smart Monitor Displays the current status of the Smart VersaPower configuration.
· VU for the amplified output: Clicking on a value shows different measurements of the signal before and after the amplifier.
· Settings: o Sensitivity: selected sensitivity. o Max RMS Power: maximum power that can be delivered by an output. o Max Peak Power: maximum peak power at an output. Not editable. o Gain: gain applied to the output to obtain the indicated power value.
75

8.12 PROCESSING
8.12.1 INPUTS PROCESSING Processing of amplifier input signals. The processing of the inputs, analogue, digital and audio player, is independent for each of them.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Parametric Equaliser (PEQ): Two crossover filters and eight fully configurable filters. Module selected and enabled. Changes made in processing are applied in real time. Module selected and disabled. If a module is disabled on an output, it cannot be edited.
76

Module enabled, not selected. Module not selected and disabled. Selector to enable/disable (bypass) the processing module.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

2. Inputs

Input selection: the selected input stands out from the rest, larger and brighter.

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

7 7

8.12.1.1 PEQ INPUTS
Parametric Equaliser (PEQ) with 10 filters (2 crossover and 8 configurable) independent for each of the analogue, digital and audio player inputs. .

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Filter selector and equaliser curve

Filter selector. Allows selection of PEQ filters for display and parameter setting.

Filter selected and enabled.

Filter selected and disabled.

Filter not selected and enabled.

Filter not selected and disabled.

Copy and paste equalisation curve: allows you to replicate the 10 filter settings on different outputs
Allows the display of the equalisation curves for the different inputs.

78

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Parameters for a filter

Filter name and button to enable/disable the filter.
Selection of filter type:
· Bell · Low-Shelf · High-Shelf · Low-Pass · High-Pass · All-Pass
Filter central frequency selector.

Filter gain selector.

Filter Q-factor selector.
Allows copying and pasting of filter parameters
Parameters for a filter: Crossovers

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Filter type selector. Cut-off frequency selector.
79

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. Graphic editing and visualiser

Information on the current parameters for the selected filter.
Level button: displays the EQ curve with the level set for an output.
Scale adjustment: modifies the gain axis (dB) for the graphical representation of the EQ curve.
· -12dB: between +12dB and 12dB
· -30dB: between +18dB and 30dB
· -60dB: between +18dB and 60dB
Filter selected: · Up/Down: modifies the gain. · Left/right: changes the frequency.
Scrolling (mouse wheel): modifies the Q-factor.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

80

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.12.2 OUTPUTS PROCESSING
Processing of amplifier output signals. The processing of the amplified and auxiliary outputs is independent for each one. It consists of the following modules:
· Delay: delay settings. · Parametric Equaliser: Two crossover filters and eight fully configurable filters. · Limit: limiter

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Processing Modules.

Management of processing modules. It allows the selection of modules for display and configuration of parameters and enables and disables the module quickly without having to open the settings page.
81

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Module selected and enabled. Changes made in processing are applied in realtime.
Module selected and disabled. If a module is disabled on an output, it cannot be edited.
Module enabled, not selected.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Module not selected and disabled.

DESCRIPTION & FEATURES

Selector to enable/disable (bypass) the processing module.
Output selection: the selected output is larger and brighter than the others.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

82

8.12.2.1 DELAY Output signal delay.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

A

Selection of units:

· Milliseconds: setting 0-1000 ms.

· Metres: adjustment 0-343 m.

B

Delay setting, by fader or by entering a

numerical value:

· Fine adjustment: 0-1 ms, allows delay adjustment with an accuracy of 0.021 ms.

· Coarse adjustment: 0-1000 ms, allows a delay adjustment with an accuracy of 1 ms.

83

8.12.2.2 PEQ OUTPUTS (PARAMETRIC EQUALIZER OUTPUTS)
It allows the selection of parametric equalisation presets, of 10 filters (2 crossover and 8 configurable) independent for each amplified and auxiliary output.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

The PEQ configuration of each output is saved in the device settings. It is not saved in the user presets unlike the user GEQ.
The user GEQ is placed after the PEQ but before the Limiter in the processing chain.
84

1. Parametric EQ Setting: parametric equalisation preset selection.

· The "Flat" setting resets all filters to their default values.
· Changes to settings are shown in the PEQ as "custom".

The settings icon

provides access to

the management of user equalisation curves.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Management of user equalisation curves Allows you to manage user equalisation curves: save, delete, rename, import and export.
· Save custom equalisation curves: o Make the desired EQ settings for an output. o Click on the settings icon to open the "Custom EQ Settings" dialogue box. o Click on the "+ New EQ Setting" button. o Rename it with a unique name. o Click on the "Save" button
· You can save as many EQ curves as you wish. · The saved EQ curves will be available in the EQ load list. · To delete an EQ curve, click on it and then click on the "delete" icon. It will
no longer be available from the list of EQs.
The factory equalisation curves cannot be changed.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

85

· Exporting and importing custom EQ curves
o Export: click on the "Export" button to download a CSV containing all custom EQ curves.
o Import: click on the "Export" and select a valid EQ CSV file. Either exported from another VIDA device or manually modified.

The CSV can be opened with Notepad or Excel to edit the content. The imported EQ curves replace the existing ones.

Information for manual editing of EQ CSV files

Filter Type 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Bypass Bell Low-Shelf 6dB/oct Low-Shelf 12dB/oct High-Shelf 6dB/oct High-Shelf 12dB/oct Low-Pass 6dB/oct Low-Pass 12dB/oct High-Pass 6dB/oct High-Pass 12dB/oct All-Pass 1 All-Pass 2 Low-pass Butterworth 6dB/oct High-pass Butterworth 6dB/oct Low-pass Butterworth 12dB/oct High-pass Butterworth 12dB/oct Low-pass Butterworth 18dB/oct High-pass Butterworth 18dB/oct Low-pass Butterworth 24dB/oct High-pass Butterworth 24dB/oct Low-pass Bessel 12dB/oct High-pass Bessel 12dB/oct Low-pass Bessel 18dB/oct High-pass Bessel 18dB/oct

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
86

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

24

Low-pass Bessel 24dB/oct

25

High-pass Bessel 24dB/oct

26

Low-pass LinkwitzRiley 12dB/oct

27

High-pass LinkwitzRiley 12dB/oct

28

Low-pass LinkwitzRiley 24dB/oct

29

High-pass LinkwitzRiley 24dB/oct

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

2. Filter selector and equaliser curve Filter selector. Allows selection of PEQ filters for display and parameter setting.
Filter selected and enabled.
Filter selected and disabled.
Filter enabled, but not selected.
Filter not selected and disabled.
Copy and paste EQ curve: allows you to replicate the 10 filter settings on different outputs.
Allows the display of the equalisation curves for the different outputs.

INSTALL & CONNECT

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

87

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. Parameters for a filter

Filter name and button to enable/disable the filter.

Selection of filter type: · Bell · High-Shelf · Low-Shelf · High-Pass · Low-Pass · All-Pass
Filter central frequency selector.

Filter gain selector. Filter Q-factor selector. Allows copying and pasting of filter parameters

Parameters for a filter: Crossovers

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Filter type selector Cut-off frequency selector
88

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

4. Graphic editing and visualiser:
Editing filter parameters represented graphically.
Information on the current parameters for the selected filter.
Level button: displays the EQ curve with the level set for an output.
Scale adjustment: modifies the gain axis (dB) for the graphical representation of the EQ curve.
o -12dB: between +12dB and -12dB o -30dB: between +18dB and -30dB o -60dB: between +18dB and -60dB
Filter selected: o Up/down: modifies gain. o Left/right: Changes the frequency. o Scrolling (mouse wheel): modifies the Q-factor.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

89

8.12.2.3 LIMITERS RMS and peak output signal limiters.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Configuration of limiters
If an output is set to stereo, the limiters for the paired outputs are displayed on the same page.
By default, when configuring two stereo outputs, the limiters of those outputs are linked; any modification of the parameters of the limiter for one output also applies to the other output. The link can be undone, to independently configure the stereo output limiters, without affecting routing.
Stereo output limiter link button.
Limiter Settings: automatic limiter setting selection.
· The "None" setting sets all limiters to their default values.
· Any changed setting is shown in the combo box as "custom".
90

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Monitoring of levels of an output:
· Gain: gain for the output. · Level pre-lim: Output level prelimiter, before
reduction. · Level post-lim: output level post-limiter after
reduction. · Reduction: reduction of output signal
Output signal limiter settings (RMS):
· Threshold: threshold for the RMS signal at which the limiter starts to act.
· Auto Att&Rel: automatic attack and release settings. If this option is disabled, manual adjustment is possible.
Output signal limiter (Peak) settings:
· Threshold: threshold of the peak signal, at which the limiter starts to act.
· Auto Att&Rel: automatic attack and release settings. If this option is disabled, manual adjustment is possible.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

The RMS and peak limiter settings are independent, they can be enabled independently.

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

2. Monitoring limiters

Monitoring of the levels of the four outputs and their reduction.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

91

8.13 GROUPS Configuration of the local groups and network groups for the device.
· An output can belong to several different groups: local, general and network. · If an output belongs to different groups, its volume will be affected by the
different volume controls of the groups.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Local Groups: VIDA has four local volume control groups, source selection and graphic equalisation. Group volume controls are placed after the output volume controls and before the General Volume control in the processing chain.
92

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Group configuration: o Label: group label. o NGRP: Network Group Indicator. If lit, it means that the group belongs to at least one network group. Clicking on the indicator brings up the list of groups to which the output belongs; the list can be edited quickly from there. o Volume control and group mute. o User Range. Volume limits set by the user via user panels. o Colour: allows assignment of a colour to the group.
Assigning outputs to a local group.
Each column corresponds to a group: all outputs enabled in the same column belong to the same group.
Output groups can be expanded or collapsed.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

2. General Volume: Local volume control group for the amplified outputs. Differences between General Volume and a local group: · Group volume controls are placed after the output volume controls and before the General Volume control in the processing chain. · The general volume group is local, it cannot belong to a network group. · It is exclusive to the amplified outputs.
93

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Group configuration: o Label: group label. o Volume control and group mute. o User Range. Volume limits set by the user via user panels. o Colour: allows assignment of a colour to the group.
Assignment of outputs to the general volume group.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

3. Net Groups VIDA has four volume control network groups. The network groups do not have source selection and equalisation. Network groups allow control of volume for several outputs belonging to different devices simultaneously.
· The group volume controls are located at the end of the processing chain. · An output can belong to several network groups. · If an output belongs to different groups, its volume will be affected by the
different volume controls of the network groups. · There is a maximum of four network groups per amplifier group (Group ID). · Groups are shared by all devices that are on the same network and belong
to the same amplifier group (Group ID). · An output can belong to several network groups. · An amplifier can only belong to one amplifier group (Group ID). · The network groups and Group ID are independent of the VIDA amplifier
model. The network groups allow control of the volume of different outputs
belonging to different VIDA amplifier models: VIDA-16Q*, VIDA-24Q and VIDA-48Q*
* VIDA-16Q and VIDA-48Q will be available soon.
If the two network interfaces, NET1 and NET2, are connected the network groups will communicate via the NET1 interface only. If only one network interface is connected, the network groups will communicate over that interface.
94

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

A. Management of devices

· Discover: discovers VIDA devices on the same local network.
· Local Device: local device. Equipment to which you are connected. Displays the Group ID, the name of the equipment and its IP address.
· Group Network Devices: group of network devices with the same Group ID as the local machine. Displays the Group ID, the name of the equipment and its IP address.
Clicking on a network device displays its group assignment matrix and options:

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

o : delete or forget the device. The Discover button returns to this list.
o : opens the device configuration app in a new window.
· Other Network Devices: group of network devices with a different Group ID than the local machine. Displays the Group ID, the name of the equipment and its IP address.
95

Panels APP

Users Register TP-NET Protocol

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

B. Network group configuration

Group configuration: · Label: group label. · Volume control and group mute. · Colour: allows assignment of a colour to the group.
Assignment of outputs to a network group.
· Each column corresponds to a group.
· All outputs enabled in the same column belong to the same group.
Output groups can be expanded or collapsed.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

96

8.14 EVENTS
Events that allow the device to automate actions and interact with external devices, such as volume control GPIs and internal functions such as the audio player.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. Event Management

Management of the list of events available on the device. Allows the selection of an item from the list for display and configuration and to perform actions without having to open the configuration page.
By default there are five predetermined events which can be modified, disabled or deleted. They are recovered when the device is reset to factory settings.
· Volume knob1-4: volume control of the amplified outputs OUT1-4 via the front panel rotary knobs.
· External Mute: external mute affecting the four amplified outputs OUT1-4.

97

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

· Add a new event. · A unique name must
be given to add an event to the list
Event enabled and selected.
Event enabled and focused. Event disabled and selected.
Event disabled and not in focus.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Quick actions (from left to right):
deletes the event from the device.
allows renaming of event.
creates a copy of the event. enables/disables the event. A
disabled event will have no effect, although it will remain in the list of available events and its configuration will not be lost.
Move events from position:
· Allows reordering of the list of events. Press and hold and drag to the
desired position to relocate the event.
The position of an event is not linked to its priority over other events.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

98

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Event configuration

Programming of an event:
· When: when the event occurs or the input that triggers it.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

· Action: action of the event or output of the input stimulus.
Event Input: type of event input. Depending on the selection, the available options for each type of event will be loaded.
· Knob: rotary controls on the front panel. · GPI: 0-10V GPI control inputs on the
rear panel. · Load preset: Load a preset. · Calendar: calendar schedule. · External mute: external mute input from
the rear panel.

INSTALL & CONNECT

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

99

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.14.1 EVENT KNOB The event input is one of the rotary controls on the front panel (Knobs). When
Four control knobs available.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

Action

Status. indicates the current status of a rotary control, where 0 is the minimum (left) and 100 is the maximum (right).
Enables control of the volume of an audio signal.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Last action: indicates the last action for an event.
100

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.14.2 EVENT GPI The event input is one of the 0-10 VDC GPIs on the rear panel. When
Four GPIs available.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

· Input param.: selection of GPI that triggers the event.
· Configuration: GPI configuration. Can be analogue (values 0-100), or digital (values 0 or 100). Depending on the GPI's operating mode, the Action section will display different options. Configurable in the SETTINGS / Knobs/GPIOs menu.
· Polarity: determines how the signal received at the GPI is interpreted: Direct/Reverse: 0 VDC is maximum and 10 VDC is minimum or vice versa.
Status: indicates the current status of the GPI, where 0 is the minimum and 100 is the maximum.

INSTALL & CONNECT

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

101

Action (analogue mode)

Enables control of the volume of an audio signal.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Action (digital mode)

Last action: indicates the last action for an event.
Last Action does not indicate the current state of the control, but indicates the last state triggered by the event.
A GPI-digital event allows the following actions to be performed:
· Mute: Mutes the selected audio signal. · Load preset: loads the selected preset. · Load & Play: Load and play the
selected playlist. · GPO: modifies the status of the
selected GPO. · Play/Pause: resumes or stops the
current playback by an audio player.

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

102

Panels APP

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Mute

Mutes the selected audio signal. PANIC mutes all outputs

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Load Preset

Mode: Mute operating mode: · Mute Toggle: switches between Mute On and Mute Off. · Mute On: changes the status to Mute On, regardless of Mute status. · Mute Off: changes the status to Mute Off, regardless of Mute status. · Mute Hold: changes the status to Mute On for the duration of the input stimulus.
Load the selected preset.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

103

Load & Play GPO Play/Pause

Load and play the selected playlist.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Modifies the status of the selected GPO .
Only GPOs configured as event GPOs are available. Configurable in the COMMANDS/GPIOS settings.
Resumes or pauses the current playback by an audio player.
· Play/Pause: toggles between resume and pause playback.
· Play: Switches the playback status to Play, regardless of the player's current state.
· Pause: Switches the playback status to Pause, regardless of the player's current status.
104

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Panels APP

Routing GPOs VersaPower Groups Player

8.14.3 EVENT LOAD PRESET The input to the event is the loading of a preset. When
Input param.: selection of the preset that triggers the event.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Action

Enables loading and playback of the specified playlist.

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

105

8.14.4 EVENT CALENDAR
Allows the configuration of calendar-triggered events. A calendar event performs a certain action, such as loading a message with priority according to configurable parameters: date, time, repetitions, etc.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. When

Setting the time/date that trigger an event and repeat triggers for the event.

Date and start time of the event.
Priorities cannot be set between two events that are triggered on the same day at the same time. However, times can be set using seconds so that events can be sequenced at intervals of no less than one second.
106

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

Frequency: Frequency of recurrence of the event. Days on which the event is triggered at the selected start time.
· Never: one-shot event. Not repeated. · Daily: repeated daily. Repeated every day. · Weekly: repeated weekly. Repeated every seven
days, starting from the selected start date. · Monthly: repeated monthly. Repeated on a
particular date (N) in each month. N is the date in each month on which the event is triggered.
If the selected date does not exist in the month, the event is not triggered. For example, if the trigger date is 31, the event is triggered only on 31 in each month. If a month does not have 31 days, the event is not triggered.
· Annually: repeated yearly. Repeated on the same day of the same month every year. The date in the month is the same in each successive year.
· Custom: Custom repeat. See section Customise Frequency below.
End of the event. · Never: the event repeats indefinitely (2099). · After: the event ends after N shots. · Date: end date of the event. Last date triggered.
Customise Frequency
Custom Frequency allows custom frequencies to be set.
Daily: Daily.
Every: The event is triggered every N days.
Weekly: Weekly: the event is triggered on the selected days of the week, every N weeks (shown under Every).

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

107

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Monthly: Monthly: the event is triggered on the selected days in each month, every N months.
If the selected date does not exist in the month, the event is not triggered. For example, if the trigger date is 31, the event is triggered only on 31 in each month. If a month does not have 31 days, the event is not triggered.
Yearly: Yearly The event is triggered in the selected months of each year, on the same day as the start date, every N years.
After applying the changes, a brief summary of the event trigger frequency setting is displayed.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

108

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

2. In-day Repeats

Repeat firings of an event within the same day.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Enables or disables in-day repeats.
· Disabled: there are no in-day repeats. The event will be triggered once on each day, in function of the trigger frequency setting.
· Enabled: the event is repeated within the same day, according to the daily repeats configuration. The repeats occur every trigger day for the event, which is determined by the trigger frequency.
Start At: Time of first trigger, as configured by the event trigger frequency. Subsequent triggers during a day are viewed as repeats of the first trigger. On a given day the event is triggered 1 (first trigger, frequency) plus N repetitions.
Repeat Every: Repetition interval or frequency of in-day repetition.
End of the event.
· Never: the event repeats indefinitely up to 23:59.
· After: the event ends after N repetitions. · Time: end time for the event. After this
time, no more repeats are triggered.
If a repeat takes place at the end time for repeats, it will be the last replay of the day.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

109

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

3. Action A. Action Mute:

A calendar event allows the following actions:
A. Mute: Mutes the selected audio signal. B. Load Preset: loads the selected preset. C. Load & Play: Load and play the selected playlist. D. GPO: modifies the status of the selected GPO . E. Play/Pause: Continues or stops the current
playback by an audio player.

Web HW GUI

PRECAUTIONS

Mutes the selected audio signal. PANIC mutes all outputs.

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Mode: mode of operation:
· Mute Toggle: Toggles between Mute On and Mute Off.
· Mute On: changes the status to Mute On, regardless of Mute status.
· Mute Off: changes the status to Mute On, regardless of Mute status.
· Mute Hold: changes the status to Mute On for the duration of the input stimulus.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

110

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

B. Action Load Preset:

Load the selected preset.

Web HW GUI

PRECAUTIONS

C. Action Load & Play:

Load and play the selected playlist.

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

D. Action GPO: E. Action Play/Pause:

Modifies the status of the selected GPO.
Only GPOs configured as event GPOs are available.
Configurable in the COMMANDS/GPIOS settings.
Resumes or pauses the current playback by an audio player. · Play/Pause: Toggles between resume and
pause playback. · Play: changes the playback status to Play,
regardless of the player's current state. · Pause: switches the playback status to
Pause, regardless of the player's current state.

4. Calendar Monitoring 111

Panels APP

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Monitoring the frequency of events and their daily repetition.
· Previous event · Time and date · Upcoming event
Indicates the number of times the event has been triggered, not counting its in-day repetitions.
· Times: first, number of times triggered / second, times remaining before the end of the event.
· Last event at: date of the last day on which the event is to be triggered.
Indicates the number of times the event has been repeated on the same day (in-day repetitions).
· Repetition: in first position, number of repeats / in second position repeats remaining before the end of the day.
· Last event at: time at which the event will be repeated for the last time.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

112

8.14.5 EVENT EXTERNAL MUTE
Mutes the selected audio outputs while the external contact close (External Mute) is closed.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

When Action

Polarity: determines how the signal received at Ext port is interpreted. Mute. · Direct: Closed = 100; Open = 0. · Reverse: Closed = 0; Open = 100. Status: indicates the current status of the Ext. Mute.
· Mutes the selected audio outputs. Multiple outputs can be selected.
· Last action: indicates the last action of the event. Last Action does not indicate the current
status of Ext. Mute, but indicates the last state triggered by the event.
113

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

Panels APP

8.15 PLAYER
Embedded audio player, playlist management and file manager.
Enables playback of mp3, ogg, WAV, FLAC, AIFF audio content from a microSD card (not included) inserted into the microSD slot on the rear panel of the device (see microSD slot location in Panel Functions section).

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1

Playing track information:

· Album art: requires an Internet connection for album art retrieval to work.

· Labels (3 screens): Track title - Artist - Album

· Track information: bit-rate per second - sample rate position in the playlist.

114

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2

· Fade mode: transition between tracks.

· Playback queue: o Name of the playlist. o The number of items in the playlist. o The track in playback.
Allows any item in the list be played by clicking Play when it is highlighted.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

3

Player control, from left to right:

· Playback mode: sequential / random. · Previous track. · Resume playback (Play / Pause). · Next track. · Repeat mode:

4

Volume, mute and VUs for the audio player

5

Transport bar:

· Playback time. · Time remaining.

Allows fast forward/reverse of the track.

INSTALL & CONNECT

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

115

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.15.1 PLAYLISTS Music playlists and their management. A playlist is a group of items that has an alias and an address on the microSD card. A playlist can contain several addresses that can point to:
· Files: an audio file. · Folders: containing audio files.
Valid audio files: mp3, ogg, WAV, FLAC, AIFF
If a file is invalid or the folder contains invalid files, such as images, the player will ignore those files and only play valid audio files.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

116

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

1. Playlist management

Management of the playlists available on the device.
Allows the selection of an item from the list for display and configuration and to perform actions without having to open the configuration page.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Add a new play list. A unique name
must be given to add the playlist to the list. Selected playlist.
Focused playlist.
Playlist not in focus.
Quick actions (from left to right):
delete a list from the device. rename a list. creates a copy of a list. shows the current playlist and enables a playlist to be played from the beginning.
If the play button for a playlist is clicked, it will start playing from the beginning. Move position playlists: allows reordering of playlists. Press and hold and drag to the desired position to reposition the list.
The order of the playlists is linked to the order in which they are displayed in the user panels.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

117

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Playlist settings

Web HW GUI
· Adds a new item to the playlist. · An alias must be given to add an item to the list.
It can be left blank, in which case the filename will automatically be set as its alias. · The filename (path/url) must be a valid address. · The file/folder must already exist on the microSD card.
Element information: · Audio file/folder icon. · Alias · Address
Quick actions (from left to right):
removes the item from the playlist. rename an item.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

118

8.15.2 BROWSER
MicroSD card browser. Allows addition and deletion of files and folders on the microSD card and viewing of their content to create playlists or edit existing lists. With no need to remove the microSD card from the device.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

1. Medium

Media selection and media options: · Upload files: adds files from your computer to the microSD card. · Upload folder: adds a folder from your computer to the microSD card. · Add to playlist: add the root address of the microSD card to an existing playlist ("mmc://"). · New playlist: creates a playlist with the root address of the microSD card ("mmc://"). · Format: format the microSD card to a valid format for the device.
Formatting the microSD card will delete all content.
119

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Users Register TP-NET Protocol

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

2. Route 3. Folders and Files

Address or path of the selected item.
· Autocomplete when an item is selected.
· An address can be entered manually.
· Allows copying and pasting.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

Folders and files on the microSD card: · Selecting a folder displays its contents. · To collapse the contents of a folder, click on it again. · Allows browsing of the content of media (microSD card).
Folder options: · Upload files: adds files from your computer to the selected folder. · Upload folder: adds a folder from your computer to the selected folder. · Add to playlist...: adds the address of the selected folder to an existing playlist. · New playlist...: creates a playlist with the address of the selected folder. · Delete: deletes the folder and its contents.

INSTALL & CONNECT

Archive options:
· Rename: rename the file · Add to playlist...: adds the address of the
selected file to an existing playlist. · New playlist...: creates a playlist with the
address of the selected file. · Delete: deletes the archive and its
contents.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

120

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

8.16 USERS
Management of device users and display of user panels assigned to users.
There are three user profiles:
· Administrator: system administrator. Has access to the device configuration web page.
· Public: public user. Has access to the user panels assigned to the profile. No login credentials are required.
· Users: users. Each user has access to the user panels assigned to them by the administrator. Requires login credentials.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

1. User management

Management of users available on the device.
Allows the selection of an item from the list, for display of the panels assigned to the user and quick actions.

121

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Add a new user.
A unique name must be given to add the user to the list of users of the device.
Same user on multiple devices: If the same user (identical name and password) is created on different devices belonging to the same local network, it is possible to assign panels to this user on different devices, allowing a single user to control several VIDA devices.
Modifies the access credentials for the administrator profile.

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Default: admin / admin User enabled and selected.
User enabled and focused. User disabled and selected. User disabled and focused.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

122

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Quick actions (from left to right):
removes a user from the device.
allows a user to be renamed and assigned a new password.
creates a copy of the user.
Enables/disables the user. A disabled user will not be able to access their panels, although they will stay in the list of available users and their settings will not be lost.
When deleting a user with assigned panels, you will be asked what should be done with those panels. Panels can:
· Be kept (Keep panels), for the other users assigned to the same panel or for assignment to other users.
· Deleted (Delete panels), when they will be unavailable to other users.
The public profile can only be enabled or disabled and cannot undergo any other operations.
The public profile is enabled by default. If disabled, the option to access the public panels on the login page will not be available.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Move position of users: · reorder the list of users. · Press and hold and drag to the desired position to relocate the user. Position 1 is always taken by the public profile.
123

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Assigned Panels Displays the panels assigned to the selected user. This list shows the panels on the local device and the panels on other devices for the same user.
The list of user panels can be sorted and can offer a different order for each user. Press, hold and drag to the desired position to relocate the Panel.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

The selected user has access to the dashboard, where the following information can be viewed:
· Name of the panel. · Number of controls within the panel. · Name of the device that contains the
panel. · IP address of the device that contains the
panel. · Edit: quick access to panel settings. · Delete: removes the panel. · Open in new tab: When a panel is located
on another networked VIDA device, there is a shortcut to the settings page for that device. Open a new browser tab with the IP address of the device.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

124

8.17 PANELS
Remote control panels for users. A user control panel is a set of controls, which allow users to remotely control - from the Ecler Vida application or from a browser - the volume, the audio player, sources and presets, and equalise one or several zones at a time.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Users Register TP-NET Protocol

1. Panel Management

Management of the list of panels available on the device. Allows the selection of an item from the list for display and configuration and to perform actions without having to open the configuration page.

125

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

A new panel is added and its properties are configured: · Label: a unique name has to be given to add an event to the list. · Player: enables the audio player on the panel.
Access to player control and playlist selection.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

·Load Preset: enables preset selection on the panel.

You will only have access

to the presets available to

users (Presets for panels -

configurable in the presets

management

drop-down

menu).

·Users: assignment of users

Panel enabled and selected.

Panel enabled and focused.

Panel disabled and selected.

Panel disabled and focused.

Public panel indicator:
· Unlocked: public panel. Assigned to the public profile.
A panel can be assigned to the public profile and users. If assigned to both, the public panel indicator is displayed.
·Locked: private panel. Assigned to one or more users, not available to the public profile.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

126

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Quick actions (from left to right):
removes the panel from the device.
allows editing of the properties of the panel
creates a copy of the panel. Enables/disables the panel. A disabled panel
will not be shown to the assigned users; it will remain in the list of available panels and its configuration will not be lost.
Move position of panels: · Allows the list of panelsto be reordered. · Press and hold and drag to the desired position to relocate the event.
The order of the list of panels is the order in which the panels are displayed to users in the Ecler Vida control app. If a user has panels for different devices, the panels are displayed grouped by device, as arranged by the user.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

2. Panel configuration Allows configuration of panel controls. Indicators for enabled controls. · Configurable in the panel properties. · Audio player control and playlist selection. · Selection of presets allowed per user.
If exclusive access to playlists and presets is required for certain users, duplicate an existing panel and enable both options.

Routing GPOs VersaPower Groups Player

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

127

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

A new control is added to the panel (at the end of the list) and its properties are configured.
· Label: a unique name must be given to add the control to the list
· Target: signal to be controlled. Depending on the selection, the control options for each type of signal are loaded automatically: sources, amplified outputs, auxiliary outputs, digital outputs, local groups, overall volume and network groups.

·

volume control and signal mute. Signal level

display.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

DESCRIPTION & FEATURES

·

selection of fonts made available to the user.

·

graphic equaliser and quick equaliser settings.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

If no control is enabled: volume, source selection or equaliser, the control displays the level of the selected signal. Useful if the area only needs to be monitored.
128

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Control
Once configured controls created in a panel are available to users assigned to that panel. The controls shown in the panel configuration can be manipulated by both the administrator and the user.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

A. Control label and selected source. B. One volume, source and EQ control selector. C. Control options: edit properties, delete and duplicate. D. Graphic volume, source and equaliser control. Displayed depending on the
option chosen in the selector.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

129

8.18 REGISTER System activity log. Allows detailed visualisation of device activity, for troubleshooting or programming tracking.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

1. Information

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Basic system information. · Local time and date for the device · Time the equipment has been in operation since the last restart. 130

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

2. Export register

Export a copy of the log lines to the microSD card.
· Frequency: export frequency o Daily: saves a daily copy of the log at the selected time o Weekly: saves a weekly copy of the log every Monday at the selected time o Monthly: keeps a monthly copy of the log on the first day of each month at the selected time
· Path: address of the microSD folder where copies of the log are stored:
If export is enabled, but the address is empty, logs are saved to the root of the microSD card.
If the address entered does not exist, the folder will be created.

The following conditions must be met for the export to be successful:
· The device is switched on the day and at the time scheduled for log export. · The microSD card is inserted. · The address has not been changed.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

131

3. Search Search in the system registry. Filter and generate reports with the required information.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

Indicates the age of the record. Filter by specific words. Filter by date:
· Today (console): displays the log for the day, from 00:00 to the time of search.
· This week: shows the log since Monday. · This month: shows the log from the 1st of
the month. · Custom: allows custom date range.
132

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Filter by log line type. More than one can be selected:
· Any: all types. · Information: normal activity. · Warning: some functions may not be
working properly. Shown in yellow.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

· Recovery: recovery from a warning or error. Shown in green.
· Error: error, something is not working properly. The proper functioning of the system may be compromised. Shown in red.
· Failure: system failure, critical error. The system requires immediate attention. Shown in red.
System starts are shown in blue, for easy identification.

DESCRIPTION & FEATURES

INSTALL & CONNECT

Filter by line category of the log. More than one can be selected. Allows a more refined search.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

133

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

Number of lines displayed per page.

Web HW GUI

When the search is confirmed, the filters applied are displayed in the console. They can be quickly deleted and new ones added. The last search performed is saved.

PRECAUTIONS

PACKAGE CONTENTS

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

4. Today (console) Log console. Displays real-time activity on the system. Each day the previous day's log is stored and replaced by the succeeding log. · Indicates the log lines, after filtering.

·

Share log, copy to the clipboard the selected

lines, for sharing in apps like an email manager, e.g.

· Download log, save a copy on your computer (browser download folder) of the selected lines in CSV format. It can be opened using a spreadsheet program.

Header of the log lines (columns): · Device Date&Time: local date and time of the device at which the activity event occurs. It can be sorted in ascending or descending order. · Type: type of activity event. Sortable alphabetically, grouping activity events by type. · Category: activity event category. Sortable alphabetically, grouping activity events by category. · Description: brief description of the activity event
Log pagination.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

134

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

9. ECLER VIDA APP
Ecler VIDA is an application for the control of one or more VIDA series amplifiers on the same local network through customised user control panels designed by the system administrator.
The app allows users to manage volume, select sources, equalise, select playlists and control the internal audio player, select presets and more.
The panels are designed exclusively for each user, simply and quickly. There is also a tool for commissioning the equipment. Compatible with Ecler VIDA series amplifiers. An Ecler VIDA series amplifier is required to create user panels and publish them on the local network.
Available for iOS and Android. Download the app free from:

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

135

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

9.1 LOGIN
There are two access profiles for the app:
· Administrator: An administrator has access to all functions of the VIDA device and can configure any amplifier parameter, event, peripherals, etc. An administrator creates users and control panels for the Ecler VIDA user app.
· User: users (non-administrator users or end-users of the system) have limited access. The only functions available to normal users are controls (e.g. controlling the volume of an output) but no configuration functions.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

The administrator profile is disabled in the iOS and Android apps.
Usernames and passwords are case-sensitive.
· Keep me logged in When this function is active, a new login will not be required each time the VIDA web app is opened. The LOGIN page will not be displayed and the last page visited will be displayed. To deactivate, log out of the web app.
· Forgot password Allows users to change their password Password.
· Public Panels Access to control panels, public profile (no login credentials required). These control panels must be created by an administrator.
· Navigation On accessing the app, the last panel selected is displayed. The app has a navigation menu at the bottom of the screen: · Home: panel selected. · Panels: list of panels assigned to the user. · Settings: application settings.
136

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

9.2 SETUP DEVICE
Quick start-up and/or discovery of VIDA devices on the same local network.
If you are setting up an installation with several VIDA devices, log in to the web app of any of the devices or open the mobile app, click on "Setup device" on the welcome page to discover VIDA devices and get network information for the devices and easy access to them.
The Setup Device button takes you to the tutorial: · Welcome page. · Link to device documentation.

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

DESCRIPTION & FEATURES

INSTALL & CONNECT

Connect the VIDA device to the mains and switch on the device.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

137

· Connect the VIDA device to the router/switch using a CAT5 cable or higher (NET1 Ethernet port on the VIDA device).
· Connect the Smartphone to the same local network as the VIDA device over WiFi.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

If there are devices on the local network that have been discovered, a list of accessible devices on the local network is displayed.
· Clicking on the name of a device opens a tab in the default browser for the IP address of the device.
· Important information about the device is displayed, with options for access to its web app (for configuration by the system administrator). Copy one or more links and paste them into your browser, on the same or another device.
If there are no computers on the local network or none have been discovered, other connection options and troubleshooting options are displayed:
· Try again: try to re-establish a connection. When a connection has not been made correctly or the network configuration of a device has been changed recently.
· Check that your local network has a DHCP server. If no DHCP server is found the VIDA device can be accessed via IP address: 192.168.0.100. Locate your smartphone in the same IP range to access the device.
138

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

9.3 HOME
Home page shows the selected panel (from the list of available panels). This page shows all the controls for a panel.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

Audio player
If the audio player is enabled in the panel, playback control and playing track information are displayed at the bottom of the screen. Clicking on the control opens the audio player page.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

139

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Playlist selection. All playlists available on the device are displayed.
Playing track information:
· Album art: requires an Internet connection for album art retrieval to work.
· Tags ID3: Track title - Artist - Album. · Track information: bit-rate per second - sample rate -
position in the playlist.
Audio player control:
· Playback time. · Time remaining. · Allows fast forward/reverse of the track. · Sequential/random playback mode. · Previous track. · Resume playback (Play / Pause). · Next track. · Repeat mode: · Fade mode: transition between tracks. · See playback queue.
Playback queue:
· Name of the playlist. · The number of items in the playlist. · The track in playback. · Allows you to play any item in the list by clicking play
over the item.

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

140

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Preset selection

Presets available on the panel.

Web HW GUI

PRECAUTIONS

PACKAGE CONTENTS

DESCRIPTION & FEATURES

The playlists and the list of available presets is not exclusive to the user. The same lists are available to any user with access to the panel.
If exclusive access to playlists and presets is required for certain users, duplicate an existing panel and enable both options.
9.4 MY PANELS List of panels available to the user.
· Click to select a panel. · Name of the user panel. · Device containing the panel. If the user has
panels on several VIDA devices, they are all listed here, regardless of the device.

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

141

9.5 SETTINGS APP Control app settings.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Devices

List of devices on the same local network. Clicking on a device displays its information page.

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

142

Device information: · Important device information. · Health: shows the health status of the device. · Share Log: share the daily log for the device.
Copies lines from the daily log to the clipboard for sharing in applications such as an email manager.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

UI Scale

Set the display size for the GUI.

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

143

Support

Useful links: · Read: VIDA amplifier documentation. · Watch: link to VIDA's YouTube page. Contains
training and promotional videos. · Contact: Ecler Technical Support contact form.

Web HW GUI

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

About

Displays information related to the app: · Version · Privacy Policy · Open source licences.

Routing GPOs VersaPower Groups Player

Panels APP

Inputs/Outputs Setup Processing Events

Users Register TP-NET Protocol

DESCRIPTION & FEATURES

INSTALL & CONNECT

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

144

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

10. TP-NET PROTOCOL
10.1 INTRODUCTION TP-NET PROTOCOL
The TP-NET protocol allows a client machine (or control device) to query and modify various internal parameters.
Communication with such devices can be done over Ethernet and using the UDP/IP transport protocol, using UDP registered port 5800.
The protocol is simple and textual, making it easy to read, write code and modify, and is message-based, with no need for start and end delimiters: each message is implicitly delimited by the size of the UDP packet. The maximum message size is 80 characters. All texts must be written in capital letters.
To facilitate the processing of messages in control systems such as CRESTRON®, AMX®, RTI®, VITY®, MEDIALON®, etc., the device adds the character LF (0x0A) at the end of each message. If the client program does not have time to process the received messages one by one, it can concatenate consecutive messages into a single memory string (buffer) and separate them again later using the LF delimiter. The device also allows several messages to be sent in a single data packet and read using the delimiter.
Messages are made up of one or more fields, separated by blanks ( = blank space):
<TYPE> [PARAM1] [PARAM2] [PARAM3] [PARAM4][LF]
The first field (TYPE) defines the type of message, and therefore the number of parameters required below (each type of message requires a certain number of parameters). The TYPE field can have the following values:
· SYSTEM · GET · SET · INC · DEC · Subscribe to · UNSUBSCRIBE · DATA · ERROR

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Inputs/Outputs Setup Processing Events

Web HW GUI

The table in the chapter VIDA Parameters describes the different types of messages and their associated parameters.

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

145

SYSTEM, GET, SET, INC, DEC, SUBSCRIBE and UNSUBSCRIBE messages can be sent from the client to the device; DATA and ERROR messages are sent from the device to the client. SYSTEM PING is the only SYSTEM message sent by the device if the optional PINGPONG parameter is specified in the client SYSTEM CONNECT message.
Communication is initiated when a client sends a SYSTEM CONNECT message to the device. As UDP communication is connectionless (unlike TCP communication), the device stores the IP address of the client sending the SYSTEM CONNECT message to be used as a destination for the messages generated by the device itself (DATA and ERROR). After receiving a connection message, the device performs a data dump by sending all implemented DATA values one by one.
Communication can be terminated in two ways:
· Manually: when the client sends the SYSTEM DISCONNECT message , which cancels all subscriptions and stops the sending of DATA and ERROR
· Automatically: if in the initial SYSTEM CONNECT message the optional parameter PINGPONG was specified and the client has not received SYSTEM PONG messages for a period over 10 seconds (assumed loss of communication).
SET messages sent by the client have no feedback, i.e. The device does not send a DATA message after processing the SET message. The client updates the value internally with the data sent to the device and, if necessary, uses a GET message to verify that the parameter has been correctly processed in the device.
· Numerical values are always unsigned whole numbers (positive numbers without decimals).
· [PINGPONG] is an optional parameter used to configure communication with the client so that it is possible to determine whether either party has terminated communication. When configured in this way, the device sends a SYSTEM PING message periodically (once every second) to the client, which must reply with a SYSTEM PONG message. If either party does not receive the relevant message within 10 seconds, communication is deemed to have been terminated.
· <Input Channel> and <Output Channel> are numeric values that identify an input or output channel on the device.
· <Preset Number> is a numeric value that identifies one of the Presets available in the device's memory.
· <Level>, <Pre VUmeter Level> and <Post VUmeter Level> are numerical values in the range [0-100] which define values on a scale equivalent to [-inf-0] in dB
· <GPI> and <GPO> are numeric values in the range [1-8]. · <GPI Value> is a numeric value in the range [0-100] that indicates the value of an
analogue input. If the input is digital, the two possible values are 0 and 100.

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Users Register TP-NET Protocol

Inputs/Outputs Setup Processing Events

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Web HW GUI
146

Panels APP

Routing GPOs VersaPower Groups Player

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

· <GPO Value> is a numeric value in the range [0-1], i.e. it can only take the value 0 or 1 (relay contact open or closed).
· <Rate> is a numeric value in the range [1-10] that specifies the frequency of sending VU meters to the client, in number per second (default = 3).
· "<Device Name>" indicates the device name in double quotes to allow for names with spaces.
· <Error ID> is a numeric value encoding a type of error. · "<Error Description>" is a text string enclosed in double quotes containing a
description of the error.
10.2 VIDA PARAMETERS
Communication between client and device is established with an initial SYSTEM CONNECT message. If not, commands from the client to the device will be ignored by the device. See the chapter TP-NET Protocol Introduction for more information.
The INC and DEC commands generate a DATA command response from the device, containing the resulting LEVEL value, incremented or decremented. When the INC or DEC command attempts to adjust to a value outside the minimum and maximum allowed limits, no response will be produced (no DATA command will be sent).

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

TYPE DEVICE SYSTEM

PARAM1
CONNECT

GET

DISCONNECT SUBSCRIPTION_RATE PING PONG PING INTERVAL
ALL POWER PRESET SLEVEL OLEVEL / CHAN_VOL

XLEVEL GLEVEL SMUTE OMUTE XMUTE GMUTE ZONERIN

PARAM2
[PINGPONG]
<Rate>
<1-1000>
<Source> <Output Channel > <Source> <Loc/Net/Gen> <Source> <Output Channel > <Source> <Loc/Net/Gen> <Output>

SVU OVU ALARM_PROTECT ALARM_FAULT GPI GPO EXTMUTE INFO_NAME INFO_MODEL INFO_VERSION INFO_MAC IP_CONFIG IP_LIST Z_MONITOR

<Source> <Output Channel > <Output Channel > <Output Channel > <Input> <Output>
<NET1/NET2> <NET1/NET2>
<Output Channel >

PARAM3
[ONCE]
<Output Channel > <Group> <Output Channel > <Group>

PARAM4

DESCRIPTION
Saves the cl ient IP address for responses and then dumps current device status (with DATA messages) Cancel subscriptions and terminates communication Times per second for subscriptions refresh (1-10) Al ive message from device Al ive ACK message from cl ient Ping Interval , in seconds
Dumps current device status (with DATA messages) Gets the Device RUNNING/SLEEP status Gets the current PRESET Gets the current LEVEL of an audio Source Gets the current LEVEL of an Output Channel (Main:1~4, Aux: 4,5, Digital : 6~10) Gets the current LEVEL of a Matrix point Gets the current LEVEL of a Group Gets the current MUTE Status of an audio Source Gets the current MUTE status of an Output Channel Gets the current MUTE status of a Matrix Point Gets the current MUTE of a Group Gets zoner repl ica for given Output (1~4=Main, 5,6=Aux, 7~10=Digital ). For main outputs, can be S1~4, for Aux outputs, can be S1~4 and al so O1~4 (Main output 1~4), for Digital outputs can be S1~4, O1~4 and al so A1~2 (Aux out 1~2) Gets the VU-meter val ue of an audio Source Gets the VU-meter val ue of an Output Channel Gets the Protect al arm status of an Output Channel Gets the sel f-diagnosis system al arm status of an Output Channel Gets the current val ue of a General Purpose Input Gets the current val ue of a General Purpose Output Gets the current val ue of the External Mute Input Gets the Device Name Gets the Device Model Gets the Firmware Version Gets the Device MAC address for NET1 or NET2 Ethernet interface Gets NET1/2 ethernet interface addresses info Gets l ist of registered TP-Net cl ients Gets Impedance monitor status of an Output Channel

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

147

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

Routing GPOs VersaPower Groups Player

SET

POWER PRESET SLEVEL OLEVEL
XLEVEL GLEVEL SMUTE OMUTE XMUTE GMUTE ZONERIN

INC DEC

GPO SLEVEL OLEVEL XLEVEL GLEVEL
SLEVEL OLEVEL

XLEVEL
GLEVEL
SUBSCRIBE ALL SVU OVU
UNSUBSCRIBE ALL SVU OVU
DATA POWER PRESET SLEVEL OLEVEL
XLEVEL GLEVEL SMUTE OMUTE XMUTE GMUTE ZONERIN

SVU OVU GPI GPO EXTMUTE ALARM_PROTECT ALARM_FAULT INFO_NAME INFO_MODEL INFO_VERSION INFO_MAC Z_MONITOR Z_MONITOR ERROR CODES 0 1 2 3 4 ERROR 0 1 2 3 4 7 9 10 11 12 13 14 15

ON/OFF <Preset Number> <Source> <Output Channel >
<Input Channel > <Source> <Loc/Net/Gen> <Source> <Output Channel > <Input Channel > <Source> <Loc/Net/Gen> <Output>
<Output>
<Source>
<Output Channel >
<Input Channel > <Source>
<Loc/Net/Gen>
<Source>
<Output Channel >
<Input Channel > <Source>
<Loc/Net/Gen>

<Level > <Level > <Output Channel > <Group> YES/NO YES/NO <Output Channel > <Group> <Source> or <Output> or <Aux>
<GPO Val ue> <Val ue> <Val ue>
<Output Channel > <Group>
<Val ue> <Val ue>
<Output Channel > <Group>

<Source> <Output Channel >
<Source> <Output Channel >
RUNNING / SLEEPING <Preset Number> <Source> <Output Channel >
<Input Channel > <Source> <Loc/Net/Gen> <Source> <Output Channel > <Input Channel > <Source> <Loc/Net/Gen> <Output>

<Level > <Level >
<Output Channel > <Group> YES/NO YES/NO <Output Channel > <Group> <Source> or <Output> or <Aux>

<Source> <Output Channel > <Input> <Output>

<Post Vumeter Level _Left> <Post Vumeter Level > <GPI Val ue> <GPO Val ue)

<Output Channel > <Output Channel > "<Device Name>" <Device Model > <Firmware Version> <NET1/NET2> <Output Channel >

ON/OFF ON/OFF
<Error Code>

Z IN RANGE Z ABOVE Z-MAX THRESHOLD Z BELOW Z-MIN THRESHOLD SHORT-CIRCUIT (PROTECTION ON) OPEN- CIRCUIT

TPNET_ERROR_NONE TPNET_ERROR_INVALID_FIELD_TYPE TPNET_ERROR_INVALID_FIELD_PARAM1 TPNET_ERROR_INVALID_FIELD_PARAM2 TPNET_ERROR_INVALID_FIELD_PARAM3 TPNET_ERROR_TIMEOUT_PONG TPNET_ERROR_DISCONNECT_WHILE_UNCONNECTED TPNET_ERROR_INVALID_CLIENT_IP TPNET_ERROR_MESSAGE_TOO_LONG TPNET_ERROR_UNSUPPORTED_MESSAGE TPNET_ERROR_INVALID_RATE_VALUE TPNET_ERROR_MAX_CLIENTS_REACHED TPNET_ERROR_MASTER_MODE

<Level > <Level >
YES/NO

Sets the Device Power status (Running / Sl eeping) Sets the current PRESET (0-10) 0=factory, 1-10=User Sets the current LEVEL of an audio Source Sets the current LEVEL of an Output Channel (Main:1~4, Aux: 4,5, Digital : 6~10) Sets the current LEVEL of a Matrix point Sets the current LEVEL of a Group Sets the current MUTE Status of an audio Source Sets the current MUTE status of an Output Channel Sets the current MUTE status of a Matrix Point Gets the current MUTE of a Group Sets zoner repl ica for given Output (1~4=Main, 5,6=Aux, 7~10=Digital ). For main outputs, can be S1~4, for Aux outputs, can be S1~4 and al so O1~4 (Main output 1~4), for Digital outputs can be S1~4, O1~4 and al so A1~2 (Aux out 1~2) Sets the current val ue for a General Purpose Output

<Val ue>

Increases the current LEVEL of an audio Source by Val ue (Val ue can range from ±1 to ±100) Increases the current LEVEL of an Output Channel by Val ue (Val ue can range from ±1 to ±100) (Channel is Main:1~4, Aux: 4,5, Digital : 6~10)
Increases the current LEVEL of a Matrix point by Val ue (Val ue can range from ±1 to ±100) Increases the current LEVEL of a Group by Val ue (Val ue can range from ±1 to ±100)

<Val ue>

Decreases the current LEVEL of an audio Source by Val ue (Val ue can range from ±1 to ±100) Decreases the current LEVEL of an Output Channel by Val ue (Val ue can range from ±1 to ±100) (Channel is Main:1~4, Aux: 4,5, Digital : 6~10)
Decreases the current LEVEL of a Matrix point by Val ue (Val ue can range from ±1 to ±100) Decreases the current LEVEL of a Group by Val ue (Val ue can range from ±1 to ±100)

Subscribes to al l VU-meters Subscribes to an audio Source VU-meter Subscribes to an Output Channel VU-meter

Unsubscribe to al l VU-meters Unsubscribes to an audio Source VU-meter Unsubscribe to an Output Channel VU-meter

<Level > YES/NO <Post Vumeter Level _Right>

Shows the Device Power status Shows the current PRESET Shows the current LEVEL of an audio Source Shows the current LEVEL of an Output Channel (Main:1~4, Aux: 4,5, Digital : 6~10) Shows the current LEVEL of a Matrix point Shows the current LEVEL of a Group Shows the current MUTE status of an audio Source Shows the current MUTE status of an Output Channel Shows the current MUTE status of a Matrix point Shows the current MUTE of a Group Shows current zoner repl ica for given Output (1~4=Main, 5,6=Aux, 7~10=Digital ). For main outputs, can be S1~4, for Aux outputs, can be S1~4 and al so O1~4 (Main output 1~4), for Digital outputs can be S1~4, O1~4 and al so A1~2 (Aux out 1~2) Shows the VU-meter val ue of an audio Source Shows the VU-meter val ue of an Output Channel Shows the current val ue of a General Purpose Input Shows the current val ue of a General Purpose Output. Shows the current val ue for External Mute Shows the Protect al arm status of an Output Channel Shows the sel f-diagnosis system al arm status of an Output Channel Shows the Device Name Shows the Device Model Shows the Firmware Version Shows the Device MAC address for NET1 or NET2 Ethernet interface

INSTALL & CONNECT

DESCRIPTION & FEATURES

PACKAGE CONTENTS

PRECAUTIONS

Web HW GUI

Inputs/Outputs Setup Processing Events

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

148

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PLAYER GET

PLAYER_MUTE PLAYER_VOLUME PLAYER_VUMETERS PLAYER_TIME

PLAYER_CONTROL PLAYER_PLAYLIST_NAME PLAYER_QUEUE_INFO

SET
INC DEC

PLAYER_PLAY_MODE PLAYER_REPEAT_MODE PLAYER_FADE_MODE PLAYER_ITEM_TAGS
PLAYER_MUTE PLAYER_VOLUME PLAYER_CONTROL PLAYER_PLAYLIST_NAME PLAYER_PLAY_MODE PLAYER_REPEAT_MODE PLAYER_FADE_MODE
PLAYER_VOLUME
PLAYER_VOLUME

SUBSCRIBE PLAYER_ALL PLAYER_VUMETERS PLAYER_TIME
UNSUSCRIBE PLAYER_ALL PLAYER_VUMETERS PLAYER_TIME

<YES/NO> <0..100> <PLAY/PAUSE/NEXT/PREV> <ALIAS> <SEQUENTIAL/RANDOM> <PLAY_ALL/REPEAT_ALL/REPEAT_ONE> <NONE/XFADE>
<0..100>
<0..100>

Gets the MUTE status of PLAYER Gets the VOLUME l evel of PLAYER Gets the VUMETERS l evel of PLAYER Gets PLAYER el apsed, remaining and total time of the current media pl ayback Gets PLAYER A or B current pl ayback status: PLAY/PAUSE Gets PLAYER l oaded pl ayl ist name (al ias) Gets PLAYER current pl ayback queue position (index) and total number of items in it (count) Gets PLAYER current pl ayback order mode Gets PLAYER current pl ayback repeat mode Gets PLAYER current tracks pl ayback transition mode Gets PLAYER current item tags: TITLE, ARTIST, ALBUM
Sets the MUTE status of PLAYER Sets the VOLUME l evel of PLAYER Sets PLAYER control s Sets (l oads) PLAYER pl ayl ist name (al ias) Sets PLAYER pl ayback order mode Sets PLAYER current pl ayback repeat mode Sets PLAYER current tracks pl ayback transition mode
INCreases the current VOLUME of a PLAYER, a val ue from ±1 to ±100
DECreases the current VOLUME of a PLAYER, a val ue from ±1 to ±100
Subscribes to al l VU-meters and pl ayer times Subscribes to the VUMETERS l evel of PLAYER Subscribes to the TIME val ues (el apsed, remaining, total ) of PLAYER
Unsubscribes to al l VU-meters and pl ayer times Unsubscribes to the VUMETERS l evel of PLAYER Unsubscribes to the TIME val ues (el apsed, remaining, total ) of PLAYER

PRECAUTIONS

Web HW GUI

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA

149

WebGUI Home & Updates Settings Status WebGUI Connection Login Navigation EQ

PRECAUTIONS

PACKAGE CONTENTS

Routing GPOs VersaPower Groups Player

Inputs/Outputs Setup Processing Events

DESCRIPTION & FEATURES

INSTALL & CONNECT

Web HW GUI
All product characteristics are subject to variation due to production tolerances. NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, in Support / Technical requests. Motors, 166-168 -08038 Barcelona - Spain-(+34) 932238403 | information@ecler.com | www.ecler.com
150

Panels APP

Users Register TP-NET Protocol

START-UP & OPERATION PANEL FUNCTIONS TECHNICAL DATA



References

Enriqueta Arboli Adobe PDF Library 23.8.75