60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series
User's Manual

XLC-60-S Series (Independent type)

XLC-60 Series (Built-in type)

Type HL

2

110

M

M EL

SELV

For XLC-60-S Series
 Features

DC Input: 176-280VDC

 Applications

CLASS P LED DRIVER 4HB3
E334687

Note.10

·Constant power mode output with multiple stage selectable by DIP switch or NFC setting (H-type)
·Constant voltage mode output(12/24/48V)
·Plastic housing with class  and PFC design ·Meet UL8750 Class 2 / Class P power unit ·Flicker free, complying with CE ErP directive ·Standby power consumption <0.5W ·Meet emergency lighting (EL) application ·Minimum dimming level 0.1% (DALI-2 DT6) ·Dimming functions: 3 in 1 dimming (Dim-to-off)
DALI-2 + Push dimming ·5 years warranty

·Recessed Light ·Down Light ·Panel Light ·Commercial Lighting ·Decorative Lighting ·LED strip lighting ·DALI digital Lighting
 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

 Description

XLC-60 Series is a 60W with constant power and constant voltage output LED driver . It can operate from 110~305V AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch or NFC setting. Thanks to high efficiency up to 90%, it is able to operate for -25~90 case temperature under free air convection. XLC-60 is designed based on latest safety regulations with 3 in 1 and DALI-2 dimming. XLC-60 can also be adjusted for brightness with a push button as a simple way dimming, so it provides more flexibility for LED Lighting application.

 Model Encoding XLC - 60 - H -

Current setting (Blank: DIP Switch; N: NFC setting)
 Casing type: Blank: without strain-relief S: with strain-relief Function options (Blank/B/DA2)
Rated output voltage (12/24/48V or H-type) Rated wattage Series name

Type Blank
B DA2

Function H type output current selectable by DIP-switch or NFC setting. 12, 24, 48V Constant voltage output H type output current selectable by DIP-switch or NFC with 3 in 1 dimming 12, 24, 48V Constant voltage output and built-in 3 in 1 Dimming(PWM Style output) H type output current selectable by DIP-switch or NFC with DALI-2 dimming 12, 24, 48V Constant voltage output and built-in DALI-2(PWM Style output)

Note In stock

Note: NFC current setting is available for XLC-60-H type only.

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

60W Constant Voltage LED Driver

XLC-60 series

SPECIFICATION

MODEL OUTPUT INPUT
PROTECTION ENVIRONMENT SAFETY&EMC OTHERS
NOTE

XLC-60 -12-

XLC-60-24-

XLC-60-48-

DC VOLTAGE

12V

DEFAULT CURRENT

5A

24V

48V

2.5A

1.25A

RATED POWER

60W

60W

60W

SETUP,RISE TIME

800ms,180ms/230VAC ,1000ms,180ms/115VAC

VOLTAGE RANGE FREQUENCY RANGE
POWER FACTOR
TOTAL HARMONIC DISTORTION EFFICIENCY(Typ.) AC CURRENT

110~305VAC

155~400VDC

47 ~ 63Hz

PF0.95/115VAC, PF0.95/230VAC, PF0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

THD< 20%(@load 50%/230VAC; @load 75%/277VAC); THD<10%@load 100%/230VAC, THD<10%@Load 100%/115VAC (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section)

86%

87%

88%

0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC

INRUSH CURRENT

COLD START 15A(twidth=310s measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. NO. of PSUs on 16A CIRCUIT BREAKER
LEAKAGE CURRENT

25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC <0.75mA / 277VAC

STANDBY POWER Note5 CONSUMPTION Note8
OVERLOAD
SHORT CIRCUIT
OVER VOLTAGE

Standby power consumption<0.5W (Dimming OFF, only for standard version B/DA2-type)

105~180% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed.

Hiccup mode, recovers automatically after fault condition is removed

14~17V

26~35V

52~63V

Shut down output voltage, re-power on to recover

OVER TEMPERATURE

Shut down output voltage, recovers automatically after fault condition is removed

WORKING TEMP.

Tcase=-25~90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section)

MAX. CASE TEMP.

Tcase=90

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP.,HUMIDITY -40 ~ +80, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION SAFETY STANDARDS

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750(Class P), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 , GB19510.14, GB19510.1, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13

DALI STANDARDS

Comply with IEC62386-101, 102, 207

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION

I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH BS EN/EN55015, BS EN/EN61000-3-2 Class C; BS EN/EN61000-3-3; GB 17625.1,GB/T 17743, EAC TP TC 020

EMC IMMUNITY

BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV), EAC TP TC 020

FLICKER Note.9

PstLM  1, SVM  0.4

MTBF

4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25)

DIMENSION

176*45*32mm , 136*45*32mm (L*W*H)

PACKING

0.32Kg; 40pcs/13.8Kg/0.48CUFT(for XLC-60 Series);

0.39Kg; 40pcs/16.6Kg/0.61CUFT(for XLC-60-S Series);

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. Current ripple is measured 50%~100% of maximum voltage under rated power delivery. 5. Standby power consumption is measured at 230VAC. 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher
than 2000m(6500ft). 8. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without
permanently connected to the mains. 9. Flicker is measured at full load with LED strip. 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential
installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 11.This series meets the typical life expectancy of 50000 hours of operation when Tcase,particularly tc point(or TMP,per DLC), is about 75 or less. 12. For more information, please contact with MEAN WELL sales.  Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:XLC-60-SPEC 2024-03-08

Downloaded from Arrow.com.

60W Multiple-Stage Constant Power LED Driver

XLC-60 series

SPECIFICATION

MODEL

XLC-60-H-

OPEN CIRCUIT VOLTAGE Note13 60V

DEFAULT CURRENT

1400mA

CURRENT ADJ. RANGE (BY DIP SWITCH OR NFC)

0.9~1.7A

OUTPUT

CONSTANT CURRENT REGION
RATED POWER

9~54V 60W

CURRENT RIPPLE Note4 <4%

CURRENT TOLERANCE ±5%

DIMMING RANGE

0~100%

SETUP,RISE TIME Note12 800ms,100ms/230VAC ,1000ms,100ms/115VAC

VOLTAGE RANGE

110~305VAC

155~400VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF0.95/115VAC, PF0.95/230VAC,PF0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

TOTAL HARMONIC DISTORTION

THD< 20%(@load 50%/230VAC; @load 75%/277VAC); THD<10%@load 100%/230VAC, THD<10%@Load 100%/115VAC (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section)

INPUT

EFFICIENCY(Typ.) Note11 90%

AC CURRENT

0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC

INRUSH CURRENT

COLD START 15A(twidth=310s measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. NO. of PSUs on 16A CIRCUIT BREAKER
LEAKAGE CURRENT

25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC <0.75mA / 277VAC

STANDBY POWER Note5 CONSUMPTION Note8

Standby power consumption<0.5W (Dimming off, only for standard version B/DA2-type)

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

PROTECTION OVER TEMPERATURE

DA2 type: Stage 1: Derating to 75% loading; stage2: Derating to 50% loading; Recovers automatically after fault condition is removed
Blank & B type: Derating to lowest output level, Recovers automatically after fault condition is removed

WORKING TEMP.

Tcase=-25~90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section)

MAX. CASE TEMP.

Tcase=90

ENVIRONMENT

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL8750(Class P), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 , GB19510.14, GB19510.1, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13

DALI STANDARDS

Comply with IEC62386-101, 102, 207

SAFETY&EMC WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH

EMC EMISSION

BS EN/EN55015, BS EN/EN61000-3-2 Class C; BS EN/EN61000-3-3; GB 17625.1,GB/T 17743, EAC TP TC 020

EMC IMMUNITY

BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV), EAC TP TC 020

FLICKER Note.9

PstLM  1, SVM  0.4

OTHERS

MTBF DIMENSION

4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25) 176*45*32mm , 136*45*32mm (L*W*H)

PACKING

0.32Kg; 40pcs/13.8Kg/0.48CUFT(for XLC-60 Series);

0.39Kg; 40pcs/16.6Kg/0.61CUFT(for XLC-60-S Series);

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. Current ripple is measured 50%~100% of maximum voltage under rated power delivery. 5. Standby power consumption is measured at 230VAC. 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher
than 2000m(6500ft). 8. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without
permanently connected to the mains. 9. Flicker is measured at full load with LED modules. 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential
installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 11. Efficiency is measured at 1050mA/54V output set by DIP switch. 12. Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI power on function, otherwise the start up time will be higher than 0.5 second. 13.Output hiccups under no-load condition.(only for H-type). 14. For more information, please contact with MEAN WELL sales.  Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.asp

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

BLOCK DIAGRAM

EMI FILTER

I/P

&

RECTIFIERS

POWER SWITCHING

RECTIFIERS &
FILTER

DC to DC

+V -V

O.L.P.

PWM&PFC CONTROL

O.T.P.

DRIVING METHODS OF LED MODULE

 I-V Operating Area  XLC-60-H
For 60W application

60V 55V 50V 45V 40V 35V 30V 25V 20V 15V 10V
5V 0V
600mA

900mA, 54V 1050mA, 54V 1400mA, 43V 1700mA, 36V

900mA, 9V

1700mA, 9V

800mA 1000mA 1200mA 1400mA 1600mA 1800mA

CONSTANT POWER TABLE
XLC-60-H is a multiple-stage constant power driver, selection of output current through DIP switch or NFC setting is exhibited below.

CURRENT & VOLTAGE LIMIT
DETECTION CIRCUIT

DA+/PUSH DA-/N

Vo Io 9~54V 900mA

DIP S.W 1 2 3
---- ---- ----

9~54V 1050mA

---- ---- ON

9~50V 1200mA

---- ON ----

9~46V 1300mA

---- ON ON

9~43V 1400mA(default)

ON ---- ----

9~40V 1500mA

ON ---- ON

9~38V 1600mA

ON ON ----

9~36V 1700mA

ON ON ON

Note: 1.The operating voltage range which show on this table is recommend to use.

File Name:XLC-60-SPEC 2024-03-08

Downloaded from Arrow.com.

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

NFC Function Description
The output current of the NFC Mode LED driver can be adjusted using NFC via the mobile APP Operation Instruction: ·Compatible phone Install an NFC-compatible smart mobile device or phone with AndroidTM 4.1 or IOS12 updates. ·Steps for setting output current via NFC 1. Download Meanwell APP on mobile device or mobile phone, and enable NFC function. 2. Check the NFC antenna position of the mobile phone please. 3. Enter Meanwell APP ->Top left menu ­Installation Manual/APP->PowerNFC approach the LED driver NFC sensing position and perform sensing. 4. APP displays the functional parameters, and the relevant parameters are modified as required. 5. Tap the APP write button and quickly move the phone antenna close to the NFC sensing position of the LED driver. 6. The write completes when the mobile phone displays"Success".
APP Function Description:  APP Interface:

Model name
Adjustable Output Current NFC setting password

Output Current Level
GTIN

Factory setting Setting to LED Driver

·To be used through APP available on Apple Store and Google Play Store for iOS and Android, Search `MEAN WELL' on Note: Current accuracy: the numerical error between the set current and the actual current is within 2%.
Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

DIMMING OPERATION
 B type

 3 in 1 dimming function
·Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
·Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. ·Dimming source current from power supply: 100A (typ.)

Vo+ +

+

Vo-

-

DIM+ +

Additive Voltage DIM-

"DO NOT connect "DIM- to Vo-"

Output current (%)

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0% 0V 1V

2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage

Vo+ +

+

Vo-

-

DIM+

Additive PWM signal DIM-

"DO NOT connect "DIM- to Vo-"

Output current (%)

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input

 Applying additive resistance: 0~100k

100%

Output current (%)

Vo+ +
VoDIM+

90%

+

80%

70%

-

60%

50%

40%
Additive Resistance
30%

DIM-

20%

"DO NOT connect "DIM- to Vo-"

10%

0% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N

(N=driver quantity for synchronized dimming operatio)n

Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.

Dimming input: Additive resistance

2. The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle.

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

DIMMING OPERATION

 DA2 type (DALI-2 digital dimming function)
Input wiring diagram

AC/N AC/L
Push Button

AC/N AC/L
DA+/PUSH DA-/N

XLC-60

AC/N AC/L
DA+ DA-

AC/N AC/L
DA+/PUSH DA-/N

XLC-60

PUSH dimming (primary side)
·The factory default dimming level is at 100%. ·If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver. ·Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. ·The maximum length of the cable from the push button to the last driver is 20 meters.

Action Short Push Double Click Long Push

Action duration Function

0.1~1s

Turn ON-OFF the driver

Click twice in 1.5s Set up the dimming level to 100%

1.5~10s

Every Long Push changes the dimming direction, dimming up or down

PWM OUTPUT DIMMING PRINCIPLE
 For 12V/24V/48V PWM style output dimming ·Dimming is achieved by varying the duty cycle of the output current.
Output DC current ON

Io=0A

OFF TON
T

TON

Duty cycle(%) =

×100%

T

Output PWM frequency : 4kHz for B-Type fixed (Typ.) 3.2kHz for DA2-Type fixed (Typ.)

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

LOAD (%)

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

OUTPUT LOAD vs TEMPERATURE

100 12,24V/230VAC
80

48V/H type

60

110VAC

40

20

-25 -15

0

15

30

40 45 50 60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ,Ta ()
STATIC CHARACTERISTIC

LOAD (%)

100 90 80 70 60 50 40
100 110 130 150 170 190 210 230 250 270 290 305
INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage.

LIFE TIME

LOAD (%)

100 80 60 40 20

-25

0

20

45

55

65

75 85 90 (HORIZONTAL)

Tcase ()

LIFETIME(Kh)

120 100
80 60 40 20
0 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Tcase(  )

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

THD PF

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

TOTAL HARMONIC DISTORTION (THD)

 Tcase at 75

16 14 12 10
8 6 4 2 0
50%

60%

70% 80%
LOAD (1400mA)

90% 100%

110VAC 230VAC 277VAC

POWER FACTOR (PF) CHARACTERISTIC
 Tcase at 75

1

0.95

0.9

0.85

0.8

0.75

0.7 50%

60%

70%

80%

90% 100%

LOAD (1400mA)

110VAC 230VAC 277VAC

PF

THD

16 14 12 10
8 6 4 2 0
50%

60%

70% 80%
LOAD (1700mA)

110VAC 230VAC 277VAC
90% 100%

1 0.95
0.9 0.85
0.8 0.75
0.7 50%

60%

70% 80%
LOAD (1700mA)

90% 100%

110VAC 230VAC 277VAC

EFFICIENCY vs LOAD
XLC-60 series possess superior working efficiency that up to 89% can be reached in field applications.  Tcase at 75

95 90 85 80 75 70 65 60 55 50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (1400mA)

110VAC 230VAC 277VAC

EFFICIENCY (%)

95 90 85 80 75 70 65 60 55 50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (1700mA)

110VAC 230VAC 277VAC

File Name:XLC-60-SPEC 2024-03-08

EFFICIENCY (%)

Downloaded from Arrow.com.

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

MECHANICAL SPECIFICATION

 Blank type

2-3.6

(XLC-60 Built-in Type) 136 mm

Terminal Pin No. Assignment( TB1)

Pin No. 1 2

Assignment AC/N AC/L

37 mm

1 2

TB1

tc

54

 B type

Terminal Pin No. Assignment( TB1)

Pin No. 1 2

Assignment AC/N AC/L

1 TB1
2

22.5

128 mm 136 mm

tc

54

 DA2 type

Terminal Pin No. Assignment( TB1)

Pin No. 1 2 3 4

Assignment AC/N AC/L
DA+/PUSH DA-/N

1

2 3

TB1

4

22.5

136 mm

tc

54

22.5 1 23
45 mm

Case No.XLC-60 Unit:mm

TB2

1 2

DIP-SWITCH
(only for H type)

Terminal Pin No. Assignment(TB2)

Pin No. 1 2

Assignment +V -V

1

TB2

2 3

4

DIP-SWITCH
(only for H type)

123
45 mm

Terminal Pin No. Assignment(TB2)

Pin No. 1 2 3 4

Assignment +V -V
DIM+ DIM-

TB2

1 2

DIP-SWITCH
(only for H type)

1 23
45 mm

 Terminal Pin No. Assignment(TB2)

Pin No. 1 2

Assignment +V -V

TB1 wiring: 8-9mm
0.5-1.50mm2

Current adjustable

Item

Order No. Quantity(MOQ/1Bag)

Strain-relief cap 1**3XLC-SET 50pcs (2pcs 1 set)

32 mm

TB2 wiring: 8-9mm
0.5-1.50mm2

Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

XLC-60 series

MECHANICAL SPECIFICATION

 Blank type

2-3.6

(XLC-60-S Independent Type)
176 mm 136 mm 128 mm

1 2

TB1

tc

54

22.5
37 mm

Case No.XLC-60-S Unit:mm

TB2

1 2

DIP-SWITCH
(only for H type)

45 mm 31.5 mm

 B type

45 mm

Terminal Pin No. Assignment( TB1)

Pin No. Assignment

1

AC/N

2

AC/L

1 2

TB1

22.5
123

 Terminal Pin No. Assignment(TB2)

Pin No. Assignment

1

+V

2

-V

176 mm

tc

54

1

TB2

2 3

4

DIP-SWITCH
(only for H type)

 DA2 type

45 mm

Terminal Pin No. Assignment( TB1)

Pin No. Assignment

1

AC/N

2

AC/L

176 mm

 Terminal Pin No. Assignment(TB2)

Pin No. Assignment

1

+V

2

-V

3

DIM+

4

DIM-

1
TB2 2

22.5 123

1

2 3

TB1

4

tc

54

DIP-SWITCH
(only for H type)

TB1 wiring: 8-9mm
0.75-1.5mm2

Terminal Pin No. Assignment( TB1)

Pin No. Assignment

1

AC/N

2

AC/L

3

DA+/PUSH

4

DA-/N

 Terminal Pin No. Assignment(TB2)

Pin No. Assignment

1

+V

2

-V

TB2 wiring: 8-9mm
0.5-1.5mm2

32 mm

Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.

File Name:XLC-60-SPEC 2024-03-08



References