Owner's Manual for MEAN WELL models including: XLC-60 60W Multiple Stage Constant Power, XLC-60, 60W Multiple Stage Constant Power, Multiple Stage Constant Power, Stage Constant Power, Constant Power, Power
MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 11 Pages, 1.05MB
DocumentDocument60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series User's Manual XLC-60-S Series (Independent type) XLC-60 Series (Built-in type) Type HL 2 110 M M EL SELV For XLC-60-S Series Features DC Input: 176-280VDC Applications CLASS P LED DRIVER 4HB3 E334687 Note.10 ·Constant power mode output with multiple stage selectable by DIP switch or NFC setting (H-type) ·Constant voltage mode output(12/24/48V) ·Plastic housing with class and PFC design ·Meet UL8750 Class 2 / Class P power unit ·Flicker free, complying with CE ErP directive ·Standby power consumption <0.5W ·Meet emergency lighting (EL) application ·Minimum dimming level 0.1% (DALI-2 DT6) ·Dimming functions: 3 in 1 dimming (Dim-to-off) DALI-2 + Push dimming ·5 years warranty ·Recessed Light ·Down Light ·Panel Light ·Commercial Lighting ·Decorative Lighting ·LED strip lighting ·DALI digital Lighting GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description XLC-60 Series is a 60W with constant power and constant voltage output LED driver . It can operate from 110~305V AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch or NFC setting. Thanks to high efficiency up to 90%, it is able to operate for -25~90 case temperature under free air convection. XLC-60 is designed based on latest safety regulations with 3 in 1 and DALI-2 dimming. XLC-60 can also be adjusted for brightness with a push button as a simple way dimming, so it provides more flexibility for LED Lighting application. Model Encoding XLC - 60 - H - Current setting (Blank: DIP Switch; N: NFC setting) Casing type: Blank: without strain-relief S: with strain-relief Function options (Blank/B/DA2) Rated output voltage (12/24/48V or H-type) Rated wattage Series name Type Blank B DA2 Function H type output current selectable by DIP-switch or NFC setting. 12, 24, 48V Constant voltage output H type output current selectable by DIP-switch or NFC with 3 in 1 dimming 12, 24, 48V Constant voltage output and built-in 3 in 1 Dimming(PWM Style output) H type output current selectable by DIP-switch or NFC with DALI-2 dimming 12, 24, 48V Constant voltage output and built-in DALI-2(PWM Style output) Note In stock Note: NFC current setting is available for XLC-60-H type only. Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 60W Constant Voltage LED Driver XLC-60 series SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY&EMC OTHERS NOTE XLC-60 -12- XLC-60-24- XLC-60-48- DC VOLTAGE 12V DEFAULT CURRENT 5A 24V 48V 2.5A 1.25A RATED POWER 60W 60W 60W SETUP,RISE TIME 800ms,180ms/230VAC ,1000ms,180ms/115VAC VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR TOTAL HARMONIC DISTORTION EFFICIENCY(Typ.) AC CURRENT 110~305VAC 155~400VDC 47 ~ 63Hz PF0.95/115VAC, PF0.95/230VAC, PF0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) THD< 20%(@load 50%/230VAC; @load 75%/277VAC); THD<10%@load 100%/230VAC, THD<10%@Load 100%/115VAC (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) 86% 87% 88% 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC INRUSH CURRENT COLD START 15A(twidth=310s measured at 50% Ipeak) at 230VAC; Per NEMA 410 MAX. NO. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC <0.75mA / 277VAC STANDBY POWER Note5 CONSUMPTION Note8 OVERLOAD SHORT CIRCUIT OVER VOLTAGE Standby power consumption<0.5W (Dimming OFF, only for standard version B/DA2-type) 105~180% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed. Hiccup mode, recovers automatically after fault condition is removed 14~17V 26~35V 52~63V Shut down output voltage, re-power on to recover OVER TEMPERATURE Shut down output voltage, recovers automatically after fault condition is removed WORKING TEMP. Tcase=-25~90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) MAX. CASE TEMP. Tcase=90 WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP.,HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION SAFETY STANDARDS 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL8750(Class P), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 , GB19510.14, GB19510.1, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 DALI STANDARDS Comply with IEC62386-101, 102, 207 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH BS EN/EN55015, BS EN/EN61000-3-2 Class C; BS EN/EN61000-3-3; GB 17625.1,GB/T 17743, EAC TP TC 020 EMC IMMUNITY BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV), EAC TP TC 020 FLICKER Note.9 PstLM 1, SVM 0.4 MTBF 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25) DIMENSION 176*45*32mm , 136*45*32mm (L*W*H) PACKING 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for XLC-60 Series); 0.39Kg; 40pcs/16.6Kg/0.61CUFT(for XLC-60-S Series); 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. Current ripple is measured 50%~100% of maximum voltage under rated power delivery. 5. Standby power consumption is measured at 230VAC. 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. 9. Flicker is measured at full load with LED strip. 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 11.This series meets the typical life expectancy of 50000 hours of operation when Tcase,particularly tc point(or TMP,per DLC), is about 75 or less. 12. For more information, please contact with MEAN WELL sales. Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:XLC-60-SPEC 2024-03-08 Downloaded from Arrow.com. 60W Multiple-Stage Constant Power LED Driver XLC-60 series SPECIFICATION MODEL XLC-60-H- OPEN CIRCUIT VOLTAGE Note13 60V DEFAULT CURRENT 1400mA CURRENT ADJ. RANGE (BY DIP SWITCH OR NFC) 0.9~1.7A OUTPUT CONSTANT CURRENT REGION RATED POWER 9~54V 60W CURRENT RIPPLE Note4 <4% CURRENT TOLERANCE ±5% DIMMING RANGE 0~100% SETUP,RISE TIME Note12 800ms,100ms/230VAC ,1000ms,100ms/115VAC VOLTAGE RANGE 110~305VAC 155~400VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF0.95/115VAC, PF0.95/230VAC,PF0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) TOTAL HARMONIC DISTORTION THD< 20%(@load 50%/230VAC; @load 75%/277VAC); THD<10%@load 100%/230VAC, THD<10%@Load 100%/115VAC (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) INPUT EFFICIENCY(Typ.) Note11 90% AC CURRENT 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC INRUSH CURRENT COLD START 15A(twidth=310s measured at 50% Ipeak) at 230VAC; Per NEMA 410 MAX. NO. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC <0.75mA / 277VAC STANDBY POWER Note5 CONSUMPTION Note8 Standby power consumption<0.5W (Dimming off, only for standard version B/DA2-type) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER TEMPERATURE DA2 type: Stage 1: Derating to 75% loading; stage2: Derating to 50% loading; Recovers automatically after fault condition is removed Blank & B type: Derating to lowest output level, Recovers automatically after fault condition is removed WORKING TEMP. Tcase=-25~90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) MAX. CASE TEMP. Tcase=90 ENVIRONMENT WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750(Class P), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 , GB19510.14, GB19510.1, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 DALI STANDARDS Comply with IEC62386-101, 102, 207 SAFETY&EMC WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH EMC EMISSION BS EN/EN55015, BS EN/EN61000-3-2 Class C; BS EN/EN61000-3-3; GB 17625.1,GB/T 17743, EAC TP TC 020 EMC IMMUNITY BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV), EAC TP TC 020 FLICKER Note.9 PstLM 1, SVM 0.4 OTHERS MTBF DIMENSION 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25) 176*45*32mm , 136*45*32mm (L*W*H) PACKING 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for XLC-60 Series); 0.39Kg; 40pcs/16.6Kg/0.61CUFT(for XLC-60-S Series); NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. Current ripple is measured 50%~100% of maximum voltage under rated power delivery. 5. Standby power consumption is measured at 230VAC. 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. 9. Flicker is measured at full load with LED modules. 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 11. Efficiency is measured at 1050mA/54V output set by DIP switch. 12. Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI power on function, otherwise the start up time will be higher than 0.5 second. 13.Output hiccups under no-load condition.(only for H-type). 14. For more information, please contact with MEAN WELL sales. Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.asp Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series BLOCK DIAGRAM EMI FILTER I/P & RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER DC to DC +V -V O.L.P. PWM&PFC CONTROL O.T.P. DRIVING METHODS OF LED MODULE I-V Operating Area XLC-60-H For 60W application 60V 55V 50V 45V 40V 35V 30V 25V 20V 15V 10V 5V 0V 600mA 900mA, 54V 1050mA, 54V 1400mA, 43V 1700mA, 36V 900mA, 9V 1700mA, 9V 800mA 1000mA 1200mA 1400mA 1600mA 1800mA CONSTANT POWER TABLE XLC-60-H is a multiple-stage constant power driver, selection of output current through DIP switch or NFC setting is exhibited below. CURRENT & VOLTAGE LIMIT DETECTION CIRCUIT DA+/PUSH DA-/N Vo Io 9~54V 900mA DIP S.W 1 2 3 ---- ---- ---- 9~54V 1050mA ---- ---- ON 9~50V 1200mA ---- ON ---- 9~46V 1300mA ---- ON ON 9~43V 1400mA(default) ON ---- ---- 9~40V 1500mA ON ---- ON 9~38V 1600mA ON ON ---- 9~36V 1700mA ON ON ON Note: 1.The operating voltage range which show on this table is recommend to use. File Name:XLC-60-SPEC 2024-03-08 Downloaded from Arrow.com. 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series NFC Function Description The output current of the NFC Mode LED driver can be adjusted using NFC via the mobile APP Operation Instruction: ·Compatible phone Install an NFC-compatible smart mobile device or phone with AndroidTM 4.1 or IOS12 updates. ·Steps for setting output current via NFC 1. Download Meanwell APP on mobile device or mobile phone, and enable NFC function. 2. Check the NFC antenna position of the mobile phone please. 3. Enter Meanwell APP ->Top left menu Installation Manual/APP->PowerNFC approach the LED driver NFC sensing position and perform sensing. 4. APP displays the functional parameters, and the relevant parameters are modified as required. 5. Tap the APP write button and quickly move the phone antenna close to the NFC sensing position of the LED driver. 6. The write completes when the mobile phone displays"Success". APP Function Description: APP Interface: Model name Adjustable Output Current NFC setting password Output Current Level GTIN Factory setting Setting to LED Driver ·To be used through APP available on Apple Store and Google Play Store for iOS and Android, Search `MEAN WELL' on Note: Current accuracy: the numerical error between the set current and the actual current is within 2%. Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series DIMMING OPERATION B type 3 in 1 dimming function ·Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance. ·Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. ·Dimming source current from power supply: 100A (typ.) Vo+ + + Vo- - DIM+ + Additive Voltage DIM- "DO NOT connect "DIM- to Vo-" Output current (%) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage Vo+ + + Vo- - DIM+ Additive PWM signal DIM- "DO NOT connect "DIM- to Vo-" Output current (%) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input Applying additive resistance: 0~100k 100% Output current (%) Vo+ + VoDIM+ 90% + 80% 70% - 60% 50% 40% Additive Resistance 30% DIM- 20% "DO NOT connect "DIM- to Vo-" 10% 0% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N (N=driver quantity for synchronized dimming operatio)n Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%. Dimming input: Additive resistance 2. The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle. Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series DIMMING OPERATION DA2 type (DALI-2 digital dimming function) Input wiring diagram AC/N AC/L Push Button AC/N AC/L DA+/PUSH DA-/N XLC-60 AC/N AC/L DA+ DA- AC/N AC/L DA+/PUSH DA-/N XLC-60 PUSH dimming (primary side) ·The factory default dimming level is at 100%. ·If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver. ·Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. ·The maximum length of the cable from the push button to the last driver is 20 meters. Action Short Push Double Click Long Push Action duration Function 0.1~1s Turn ON-OFF the driver Click twice in 1.5s Set up the dimming level to 100% 1.5~10s Every Long Push changes the dimming direction, dimming up or down PWM OUTPUT DIMMING PRINCIPLE For 12V/24V/48V PWM style output dimming ·Dimming is achieved by varying the duty cycle of the output current. Output DC current ON Io=0A OFF TON T TON Duty cycle(%) = ×100% T Output PWM frequency : 4kHz for B-Type fixed (Typ.) 3.2kHz for DA2-Type fixed (Typ.) Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 LOAD (%) 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series OUTPUT LOAD vs TEMPERATURE 100 12,24V/230VAC 80 48V/H type 60 110VAC 40 20 -25 -15 0 15 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE ,Ta () STATIC CHARACTERISTIC LOAD (%) 100 90 80 70 60 50 40 100 110 130 150 170 190 210 230 250 270 290 305 INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage. LIFE TIME LOAD (%) 100 80 60 40 20 -25 0 20 45 55 65 75 85 90 (HORIZONTAL) Tcase () LIFETIME(Kh) 120 100 80 60 40 20 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Tcase( ) Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 THD PF 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series TOTAL HARMONIC DISTORTION (THD) Tcase at 75 16 14 12 10 8 6 4 2 0 50% 60% 70% 80% LOAD (1400mA) 90% 100% 110VAC 230VAC 277VAC POWER FACTOR (PF) CHARACTERISTIC Tcase at 75 1 0.95 0.9 0.85 0.8 0.75 0.7 50% 60% 70% 80% 90% 100% LOAD (1400mA) 110VAC 230VAC 277VAC PF THD 16 14 12 10 8 6 4 2 0 50% 60% 70% 80% LOAD (1700mA) 110VAC 230VAC 277VAC 90% 100% 1 0.95 0.9 0.85 0.8 0.75 0.7 50% 60% 70% 80% LOAD (1700mA) 90% 100% 110VAC 230VAC 277VAC EFFICIENCY vs LOAD XLC-60 series possess superior working efficiency that up to 89% can be reached in field applications. Tcase at 75 95 90 85 80 75 70 65 60 55 50 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (1400mA) 110VAC 230VAC 277VAC EFFICIENCY (%) 95 90 85 80 75 70 65 60 55 50 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (1700mA) 110VAC 230VAC 277VAC File Name:XLC-60-SPEC 2024-03-08 EFFICIENCY (%) Downloaded from Arrow.com. 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series MECHANICAL SPECIFICATION Blank type 2-3.6 (XLC-60 Built-in Type) 136 mm Terminal Pin No. Assignment( TB1) Pin No. 1 2 Assignment AC/N AC/L 37 mm 1 2 TB1 tc 54 B type Terminal Pin No. Assignment( TB1) Pin No. 1 2 Assignment AC/N AC/L 1 TB1 2 22.5 128 mm 136 mm tc 54 DA2 type Terminal Pin No. Assignment( TB1) Pin No. 1 2 3 4 Assignment AC/N AC/L DA+/PUSH DA-/N 1 2 3 TB1 4 22.5 136 mm tc 54 22.5 1 23 45 mm Case No.XLC-60 Unit:mm TB2 1 2 DIP-SWITCH (only for H type) Terminal Pin No. Assignment(TB2) Pin No. 1 2 Assignment +V -V 1 TB2 2 3 4 DIP-SWITCH (only for H type) 123 45 mm Terminal Pin No. Assignment(TB2) Pin No. 1 2 3 4 Assignment +V -V DIM+ DIM- TB2 1 2 DIP-SWITCH (only for H type) 1 23 45 mm Terminal Pin No. Assignment(TB2) Pin No. 1 2 Assignment +V -V TB1 wiring: 8-9mm 0.5-1.50mm2 Current adjustable Item Order No. Quantity(MOQ/1Bag) Strain-relief cap 1**3XLC-SET 50pcs (2pcs 1 set) 32 mm TB2 wiring: 8-9mm 0.5-1.50mm2 Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08 60W Multiple-Stage Constant Power/Constant Voltage LED Driver XLC-60 series MECHANICAL SPECIFICATION Blank type 2-3.6 (XLC-60-S Independent Type) 176 mm 136 mm 128 mm 1 2 TB1 tc 54 22.5 37 mm Case No.XLC-60-S Unit:mm TB2 1 2 DIP-SWITCH (only for H type) 45 mm 31.5 mm B type 45 mm Terminal Pin No. Assignment( TB1) Pin No. Assignment 1 AC/N 2 AC/L 1 2 TB1 22.5 123 Terminal Pin No. Assignment(TB2) Pin No. Assignment 1 +V 2 -V 176 mm tc 54 1 TB2 2 3 4 DIP-SWITCH (only for H type) DA2 type 45 mm Terminal Pin No. Assignment( TB1) Pin No. Assignment 1 AC/N 2 AC/L 176 mm Terminal Pin No. Assignment(TB2) Pin No. Assignment 1 +V 2 -V 3 DIM+ 4 DIM- 1 TB2 2 22.5 123 1 2 3 TB1 4 tc 54 DIP-SWITCH (only for H type) TB1 wiring: 8-9mm 0.75-1.5mm2 Terminal Pin No. Assignment( TB1) Pin No. Assignment 1 AC/N 2 AC/L 3 DA+/PUSH 4 DA-/N Terminal Pin No. Assignment(TB2) Pin No. Assignment 1 +V 2 -V TB2 wiring: 8-9mm 0.5-1.5mm2 32 mm Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:XLC-60-SPEC 2024-03-08