⚠️ CAUTION ⚠️ Remove existing ballasts and rewire the fixture before installing Type B tubes to avoid tube damage and fire risk.

Product Overview

This document provides the User Manual for the Sunco T8 Type B Ballast Bypass LED Tube, including installation instructions and troubleshooting tips.

SKU: T8_BY_C, T8_BY_F

Contact: support@sunco.com | (844) 334-9938

What's in the Box?

The package contains: T8 Tube

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

⚠️ WARNING: Cancer & Reproductive Harm - www.P65Warnings.ca.gov

Tombstone Compatibility

Single-Ended Installation (Non-Shunted Compatible Only)

Diagram shows a shunted tombstone with a cross mark [❌], indicating it is not compatible for single-ended installation.Diagram shows a non-shunted tombstone with arrows [⬆️], indicating compatibility for single-ended installation.

Double-Ended Installation (Non-Shunted & Shunted Compatible)

Diagram shows a shunted tombstone with a cross mark [❌], indicating it is not compatible for double-ended installation.Diagram shows a non-shunted tombstone with arrows [⬆️], indicating compatibility for double-ended installation.

Installation Guide (Without Ballast, Single or Double Ended)

STEP 1: Power Off

a. Turn off the power by locating the circuit breaker that controls the existing fluorescent fixture and switch it off.

Diagram of a circuit breaker switch with 'OFF' and 'ON' positions.

STEP 2: Remove Old Tube and Ballast

a. Carefully remove the old T8 fluorescent tube by gently twisting it and sliding it out of the tombstone sockets.

b. Remove the fixture cover, locate the ballast, then disconnect the ballast wires as indicated with an "X". Safely dispose of the ballast for cleaner wiring as well as reduce fire risk.

Diagram illustrating the removal of an old fluorescent tube from sockets and the disconnection of ballast wires marked with an 'X'.

STEP 3: Wiring

Single-Ended Wiring

Determine if the wiring for the T8 will be single-ended or double-ended:

Single-Ended:

a. Before tube installation, check if the tombstones are shunted. Replace them with new non-shunted ones.

b. Place one end of the T8 (marked L and N) into the tombstone that is powered.

c. Place the other end of the T8 into the tombstone that is not powered.

Note: If the socket lamp holders are shunted, replace them with new non-shunted ones.

Wiring diagram for single-ended installation, showing power (L, N) connected to a non-shunted tombstone.

Double-Ended Wiring

Double-Ended:

a. Wire the Live (L) to one end of the tombstone.

b. Wire the Neutral (N) to the opposite end of the other tombstone.

c. Place the T8 tube into both ends of the tombstone socket, then twist the tube to secure it into place.

Wiring diagram for double-ended installation, showing Live (L) connected to one end of a tombstone and Neutral (N) to the opposite end of the other tombstone.

STEP 4: Finalizing Installation

a. If installing multiple T8 tubes in one fixture, follow Step 3 but run the wires for the additional lights in parallel. Refer to the wiring diagram below for assistance.

b. Turn on the circuit breaker to test the light.

Note: Do NOT power the T8 tubes if the ballast has not been removed. Failure to remove the ballast will damage the tubes and cause a fire hazard.

Diagram showing multiple T8 tubes wired in parallel, connected to a circuit breaker.

Installation Guide (Multiple Lamps Wiring Diagram)

Multiple Lamps Installation (Single-Ended)

Diagram illustrating single-ended wiring for multiple T8 tubes installed in parallel.

Multiple Lamps Installation (Double-Ended)

Diagram illustrating double-ended wiring for multiple T8 tubes installed in parallel.

Product Details

T8_BY_C-18W / T8_BY_F-18W

AttributeSpecificationAttributeSpecification
Voltage120 to 277VAverage Lifetime50,000 Hrs
Wattage18WLumens2200 lm
Wattage Equivalency40WMoisture RatingDamp Rated
Beam Angle120°(Clear), 180°(Frosted)CRI80+
Efficacy120 lm/WUsageIndoor
Housing MaterialGlass (Clear/Frosted)Frequency50Hz/60Hz
DimmableNoWarranty5 Years

T8_BY_C-15W

AttributeSpecificationAttributeSpecification
Voltage120 to 277VAverage Lifetime50,000 Hrs
Wattage15WLumens1800 lm
Wattage Equivalency32WMoisture RatingDamp Rated
Beam Angle120°CRI80+
Efficacy120 lm/WUsageIndoor
Housing MaterialGlass(Clear)Frequency50Hz/60Hz
DimmableNoWarranty5 Years

T8_BY_C-24W

AttributeSpecificationAttributeSpecification
Voltage120 to 277VAverage Lifetime50,000 Hrs
Wattage24WLumens3000 lm
Wattage Equivalency52WMoisture RatingDamp Rated
Beam Angle120°CRI80+
Efficacy120 lm/WUsageIndoor
Housing MaterialGlass (Clear)Frequency50Hz/60Hz
DimmableNoWarranty5 Years

Common Troubleshooting

Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy-to-follow solutions for any problem.

If you still need some assistance, please feel free to contact Sunco Lighting with any questions. Our team of lighting experts are happy to help brighten your day.

Installation Issues

ProblemSolution
Light isn't turning on.Double check if the fixture is wired correctly and verify that the fixture is properly connected to the tombstones. Check if the circuit breaker hasn't been tripped.
Light isn't bright enough.Verify if the ballast is compatible with the fixture for Type A installation.

Flickering Issues

ProblemSolution
Light is flickering when turning on.Check that fixture wiring connections are secure.
Light flickering with other lights on the same circuit.Check that the lights on the same circuit are not overloading the circuit.
Light flickering when turned on.Verify if the ballast is compatible with the fixture for Type A installation.

Buzzing Issues

ProblemSolution
Fixture buzzing with power outages.Verify if the breaker has tripped, and carefully inspect the tube for any signs of damage.
Fixture buzzing with appliances or electronic devices.Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc.

Contact: support@sunco.com | (844) 334-9938

Revision: 1.0

Models: T8_BY_C T8_BY_F T8 Type B Ballast Bypass LED Tube, T8_BY_C T8_BY_F, T8 Type B Ballast Bypass LED Tube, B Ballast Bypass LED Tube, Bypass LED Tube, LED Tube, Tube

File Info : application/pdf, 10 Pages, 592.47KB

PDF preview unavailable. Download the PDF instead.

91USJRAorsL

References

Adobe PDF Library 17.0 Adobe InDesign 20.4 (Windows)

Related Documents

Preview Sunco T8 Type B Ballast Bypass LED Tube User Manual
User manual for Sunco T8 Type B Ballast Bypass LED Tubes, including installation guides, safety information, product details, and troubleshooting.
Preview Sunco T8 Type B Ballast Bypass LED Tube User Manual
User manual for Sunco T8 Type B Ballast Bypass LED Tubes, covering installation, safety information, tombstone compatibility, troubleshooting, and product specifications.
Preview Sunco T8 Type B Ballast Bypass LED Tube User Manual
User manual for Sunco's T8 Type B Ballast Bypass LED Tubes, covering installation, safety, troubleshooting, and specifications. Includes guides for single-ended and double-ended installations.
Preview Sunco T8 Type B Ballast Bypass LED Tube User Manual and Installation Guide
Comprehensive user manual and installation guide for Sunco T8 Type B Ballast Bypass LED Tubes. Includes safety information, quick start guide, detailed installation instructions for single-ended and double-ended configurations, wiring diagrams, specifications, and troubleshooting tips.
Preview Sunco Selectable T8 Tubes Type B - LED Lighting Specifications
Detailed specifications for Sunco's Selectable T8 Tubes Type B LED lights, featuring 2200 lumens, 50,000-hour lifespan, and 100-227V compatibility. Includes performance, environmental, and construction details.
Preview Sunco T8 8ft Clear Type B FA8 Single Pin Ballast Bypass Tube User Manual
User manual for the Sunco T8 8ft Clear Type B FA8 Single Pin Ballast Bypass Tube, including installation guide, specifications, and troubleshooting.
Preview Sunco T8 LED Frosted Lens Tube Light, Type B - Specifications and Performance
Detailed specifications and performance data for the Sunco T8 LED Frosted Lens Tube Light, Type B. Includes information on voltage, wattage, lumens, CCT, CRI, beam angle, operating temperature, and warranty.
Preview Sunco Disk 15W Selectable LED Downlight - Specifications and Features
Detailed specifications, features, and illuminance data for the Sunco Disk 15W Selectable LED Downlight (DL_DK56-15W-3K_65K). Learn about its performance, construction, and certifications.