Installation Guide for NETGEAR models including: WBE750, WBE750 Insight Manageable Wi-Fi 7 Access Point, Insight Manageable Wi-Fi 7 Access Point, Manageable Wi-Fi 7 Access Point, Wi-Fi 7 Access Point, Access Point, Point
Use two M3.5 X 25mm machine screws or thread-forming screws. These screws should be supplied with the device box. Page 14. T-Bar and Recessed Ceiling ...
File Info : application/pdf, 20 Pages, 3.68MB
DocumentDocumentPro WiFi Mount Installation Guide March 2024 Installation Guide Contents · Mount Kit Contents · Adjusting the Size of the Mount Plate · Wall and Ceiling Surface Mounting · T-Bar and Recessed Ceiling Mounting · Detaching the AP Mount Kit Contents Mount plate Deep clip Use for a recessed drop ceiling up to 0.39 in. (10 mm) Shallow clip Use for a flush or recessed drop ceiling up to 0.24 in. (6 mm) Note: Screws and anchors are not included in the mount kit. You must obtain the correct screws and anchors for the mounting method that you decide on. Adjusting the Size of the Mount Plate For some models, you might need to adjust the size of the mount plate. Before you start any installation process, we recommend that you first hook the access point onto the mount plate to determine if the size of the mount plate is correct for your model access point. The mount plate includes adjustable positions P1 through P6. Position P1 is for the smallest size plate; Position P6 is for the largest size plate. To adjust the size of the mount plate: 1. At the left and right side of the mount plate, loosen the screws at their current "P" positions. 2. Move the upper and lower parts of the mount plate to extend or reduce the size of the plate. 3. At the left and right side of the mount plate, tighten the screws at their new "P" positions. Wall and Ceiling Surface Mounting Mounting positions: A = Ceiling, Wall, or 4" Square Outlet Box B = Single Gang Device Box C = Double Gang Device Box D = 4" Round Outlet Box E = 3.5" Round Outlet Box F = EU 60mm Device Box Note: Outlet boxes and device boxes might also be called electrical junction boxes. Position A: Ceiling, Wall, or 4" Square Outlet Box Drywall Ceiling or Wall Use four 8-32 X 1.25" metal screws and anchors. (Using only two screws and anchors is not sufficient.) 4" Square Outlet Box Use two or four 8-32 X 1" machine screws or thread-forming screws. These screws should be supplied with the outlet box. Caution: We recommend that you use four 8-32 screws capable of maintaining a minimum pullout force of 20 lb. (9 kg). Use screws of the correct length with the correct ceiling or wall anchor based on your ceiling or wall substrate. Position B: Single Gang Device Box, Wood Studs, or Joists For attachment to a single gang device box, use two 6-32 x 1" machine screws or thread-forming screws. These screws should be supplied with the device box. For attachment to a wood stud or joist, use two 8-32 wood screws of the appropriate length. Single gang device box installation example Position C: Double Gang Device Box Use four 6-32 x 1" machine screws or thread-forming screws. These screws should be supplied with the device box. Double gang device box installation example Position D: 4" Round Outlet Box 4" Use two 8-32 x 1" machine screws or thread-forming screws. These screws should be supplied with the outlet box. Position E: 3.5" Round Outlet Box 3.5" Use two 8-32 x 1" machine screws or thread-forming screws. These screws should be supplied with the outlet box. Position F: EU 60mm Device Box Use two M3.5 X 25mm machine screws or thread-forming screws. These screws should be supplied with the device box. T-Bar and Recessed Ceiling Mounting Step 1. Select the deep or shallow clip based on the depth of the T-bar grid Deep clip Use the deep clip for a drop ceiling with up to a 0.39 in. (10 mm) recessed T-bar grid 10 mm Shallow clip Use the shallow clip for a drop ceiling with up to a 0.24 in. (6 mm) recessed T-bar grid 6 mm Note: You can also use the shallow clip for a flush ceiling fitting. Step 2. Attach the clip to the mount plate A. Loosen the two inner M2 screws Inner screws Outer screws B. Remove the two outer M2 screws and set them aside. C. Align the clip with the openings in the mount plate and insert the clip in the mount plate D. Rotate the clip clockwise on the mount plate. E. Turn the mount plate around and fasten the two M2 screws in position G or H to lock the clip to the mount plate. G = T-Bar 15/16" Use position G for a T-bar with a width of 15/16 " (24 mm). H = T-Bar 9/16" Use position H for a T-bar with a width of 9/16 " (15 mm). Step 3. Attach the mount plate to the T-bar A. Hold the mount plate at an angle and hook it onto the T-bar. B. Rotate the mount plate so that the T-bar flanges fit into the clip anchors. C. To secure the mount plate to the T-bar, reach through the slots under the T-bar to tighten the inner screws of the clip. Step 4. Attach the AP to the mount plate A. Attach the Ethernet cable to the AP. B. Attach the AP to the hooks on the mount plate and rotate the AP until the latch on the mount plate engages. C. Move the lock switch into the lock position. D. Attach the port cover to the AP. Detaching the AP 1. Move the lock switch into the unlock position. 2. Press the release button to disengage the latch. Support and Community Visit https://www.netgear.com/support/ to get your questions answered and access the latest downloads. You can also check out our NETGEAR Community for helpful advice at https://community.netgear.com/. Regulatory and Legal Si ce produit est vendu au Canada, vous pouvez accéder à ce document en français canadien à https://www.netgear.com/support/download/. (If this product is sold in Canada, you can access this document in Canadian French at https://www.netgear.com/support/download/.) For regulatory compliance information including the EU Declaration of Conformity, visit https://www.netgear.com/about/regulatory/. See the regulatory compliance document before connecting the power supply. For NETGEAR's Privacy Policy, visit https://www.netgear.com/about/privacy-policy. By using this device, you are agreeing to NETGEAR's Terms and Conditions at https://www.netgear.com/about/terms-andconditions. If you do not agree, return the device to your place of purchase within your return period. Do not use this device outdoors. The PoE source is intended for intra building connection only. Applicable to 6 GHz devices only: Only use the device indoors. The operation of 6 GHz devices is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet. Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with unmanned aircraft systems. NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA 95134, USA © NETGEAR, Inc., NETGEAR and the NETGEAR Logo are trademarks of NETGEAR, Inc. Any non-NETGEAR trademarks are used for reference purposes only. NETGEAR INTERNATIONAL LTD Floor 6, Penrose Two Penrose Dock, Cork, T23 YY09, Ireland