Owner's Manual for PRAXISDIENST models including: 138725, 138725 Dual Mode lnfrared Thermometer, 138725, Dual Mode lnfrared Thermometer, Mode lnfrared Thermometer, lnfrared Thermometer, Thermometer

138725-dual-mode-infared-thermometer-user-manual

Dual Mode lnfrared Thermometer Owner's Manual

Before you begin Restrictions of Use This lhermometer is clinically proven to produce accurate temperature measurements. However, please be advised !hat lhe accuracy can not be ensured when lhe lhermometer is not clean.

Download

Dual Mode Infrared Thermometer | Praxisdienst

Owner's Manual


File Info : application/pdf, 18 Pages, 1.06MB

PDF preview unavailable. Download the PDF instead.

138725-dual-mode-infared-thermometer-user-manual
Dual Mode lnfrared Thermometer
Owner's Manual

System Owner
Thank you for purchasing the Dual Mode lnfrared Thermometer. Please read this instruction manual first so you can use this thermometer safely and correctly. Please keep this instruction manual for future reference. This innovative medical device uses advanced infrared (IR) technology to measure temperature instantly and accurately on the forehead, ear or object.
IMPORTANT SAFETY INSTRUCTIONS READ BEFORE USE
The following basic safety precautions should always be taken. 1.Close supervision is necessary when the thermometer is used by, on, or near children, handicapped persons or invalids. 2.Use the thermometer only for the intended use described in this manual. Do not use the thermometer if il is not working properly, or if il has suffered any damage.
KEEP THIS INSTRUCTION IN A SAFE PLACE

TABLE OF CONTENTS

BEFORE YOU BEGIN

01

Cautions and Warnings ·············································································· 01 Restrictions of Use ····················································································· 02

lntended Use ····························································································· 02

How does it work ······················································································· 02

Highlighted Features ················································································· 03 Package Contents ····················································································· 03 Meter Overview ························································································· 04

Display Screen ·························································································· 04 Display Mode ···························································································· 05 Select the Temperature Unit ······································································ 06 Replacing the Battery · · ···· · · ···· · · · ···· · · ···· · · ···· · · ···· · · ···· · · ···· · · · ···· · · ···· · · ···· · · ···· · · ···· 07

DETAILED INFORMATION

08

About Normal Body Temperature & Fever ··················································· 08

PERFORM THE TEST

10

Using the Device · · · ···· · · ···· · · ···· · · · ···· · · ···· · · ···· · · ···· · · ···· · · ···· · · · ···· · · ···· · · ···· · · ···· · · ···· 10

As a Forehead Measurement Thermometer ·············································· 10 As a Ear Measurement Thermometer ··· · · ···· · · ···· · · ····· · · ···· · · ···· · · ···· · · ···· · · ···· · · ··· 13 As an Object Measurement Thermometer ·················································· 14

METER MEMORY

________________ 16

Recalling the Memory ················································································ 16

MAINTENANCE

18

Care & Cleaning ························································································ 18

SYSTEM TROUBLESHOOTING

19

Measurement Result ·················································································· 19 Troubleshooting ························································································· 21

SYMBOL INFORMATI=O=N====================================== 24

SPECIFICATIONS

25

DISPOSAL

27

REFERENCE STANDARDS

28

WARRANTY

29

Before you begin
Cautions and Warnings
· As with any thermometer, proper technique is crucial to obtaining accurate temperature readings. Please read this manual thoroughly and carefully before using.
· Always operate the thermometer in an operating temperature range 16°C to 40°C (60.8° F to 104°F), and relative humidity less than 85%.
· Always store the thermometer in a cool and dry place -25°C to 55°C (-13° F to 131°F) and relative humidity less than 95%.
· Avoid direct sunlight.
· Avoid dropping the thermometer, if it happens and you !hink the thermometer may be damaged, please contact customer services immediately.
· Do not touch the lens. · Do not disassemble the thermometer. · Basic safety precaulions should always be observed, especially when the thermometer is used on or near
children and disabled persons. · This lhermometer is not intended to substilute for a consultalion with your physician. · This thermometer and the patient must remain in a stable environment for at least 30 minutes before
measuring the temperature. · When the measured temperature falls within the fever temperature range of ;,,37_5°c (99.5°F) and
<43°C (109.4° F), as indicated by the red LED on display, please consult with your physician immediately.

Before you begin
Restrictions of Use
This lhermometer is clinically proven to produce accurate temperature measurements. However, please be advised !hat lhe accuracy can not be ensured when lhe lhermometer is not clean. Check !hat the probe is clean before taking a measurement.
lntended Use
lnfrared Thermometer is intended for the intermittent measurement and monitoring of human body temperature from forehead or ear measurement at harne. A control measurement using a conventional thermometer is recommended in the following cases: 1. lf the reading is surprisingly low. 2. For new-born infants up to 100 days old. 3. For children under three years of age who have a weakened immune system or who react unusually in the presence or absence of fever.
How does it work
The lhermometer measures the infrared heat generaled by the surface of the skin or lhe ear cannal over the vessel and its surrounding tissue. The thermometer then converts il into a temperature value.
NOTE: The thermometer does not emit any infrared signal.
2

Before you begin
Highlighted Features
· Dual mode (ear & forehead) measure the body temperature. · Automatically power off if left idle for 1 minute. · Memory function allows you to recall previous results up to 20 previous results. · Easy to read LCD with green backlight in a dark environment. · Color visible indication of alarm (red) and measurement in progress (green).
Package Content

0 

uearm/Moomdeetlenrfrared  8

Thermometer

User's Manual 3

1.5V AAA batteries

Before you begin Meter Overview

Display Screen

1--8
2 3

2 3

7

4

5

6

4

1 SCAN/Memory Button 2 Display Screen 3 ON/MODE Button

4 Battery Cover 5 Probe cap

1

Object temperature indicator

5 Low battery indicator

2

Ear temperature indicator

6 Memory mode

3

Forehead temperature indicator

7

Temperature reading

4 Temperature unit

4

Before you begin Display Mode

Forehead mode

Three modes can be selected. 1. Forehead Mode This mode is used to measure the forehead temperature.

2. EarMode T his mode is used to measure the ear temperature.

Ear mode

:o

,,.,,

o,-

3. Object Mode This mode is used to measure the object temperature.

Object mode

5

Before you begin Select the Temperature Unit
This meter provides two measurement units used for indicating the body/object temperature, °C or °F, for your preferred selection.
1. Lang press the "Scan" button until display the temperature unit with the shutdown state. 2. released the "Scan" button , short press the "Scan" button again , switch the temperature to °C or °F.

1 ,'1;,I- BLssg

M --- --- "SCAN"

-- -

seconds

- - ,/1\ihortpress "SCAN""

seconds

OffmOOel

6

Before you begin Replacing the Battery
The thermometer comes with two 1.5 V AAA alkaline batteries. The meter will display " " to alert you when the meter power is getting low, please follow the steps below to replace new batteries immediately.
1. Remove the battery cover as the arrow direction accordingly.
2. Remove the old batteries and replace with two 1.5V AAA size alkaline batteries.
3.Close the battery cover.
NOTE: 1. Although the thermometer works when" " appearing,
we still recommend that you change the batteries to obtain an accurate result. 2. Remove the batteries if stored for a lang period of time. 3. The batteries should be kept away out of children's reach. lf they are swallowed, promptly see a doctor for help.
7

Detailed information
About Normal Body Temperature & Fever
T he temperature in the forehead and temple area differs from the internal temperature, which is taken orally or rectally. Vasoconstriction, an effect which constricts the blood vessels and cools the skin, can occur during the early stages of a fever. In this case, the temperature measured by the lnfrared Forehead thermometer may be unusually low. lf the measurement therefore does not match the patient's own perception or is unusually low, repeat the measurement every 15 minutes. As a reference, you can also measure the internal body temperature using a conventional oral or rectal thermometer. Body temperature can vary from one individual/person to next. lt also varies by location on the body and time of day. Below shows the statistical normal ranges from different sites. Please keep in mind !hat temperatures measured from different sites, even at the same time, should not be directly compared. Fever indicates !hat the body temperature is higher than normal. T his symptom may be caused by infection, overdressing or immuniza tion. Some people may not experience fever even when they are ill. T hese include, but are not limited to, infants younger than 3 months old, persons with compromised immune systems, persons taking antibiotics, steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with certain chronic illnesses. Please consult your physician when you feel ill even if you do not have fever.

Detailed information

Table*1 Body Site Normal Temperature Range

Oral

0.6°C (1°F) or more above or below 37°C (98.6°F)

Rectal/ear

0.3°C to 0.6°C (0.5°F to 1°F) higher than oral temperature

Axillary (armpit) 0.3°C to 0.6°C (0.5°F to 1°F) lower than oral temperature

*1. Body Temperature at WebMD; website: http://firstaid.webmd.com/body-temperature retrieved at 2010 Jan 7.

8

9

Perform the test Using the Device
As a Forehead Measurement Thermometer

---

1. Touch "ON/MODE" Switch to turn on the thermometer first.

Forehead mode
2. Press the Mode button to select Forehead mode. The temperature unit flashes.

3. Move the probe close to the forehead.

Make sure the probe is flat and close to the forehead, not at an angle. Perform a forehead measurement with a distance within 0-2 cm. press the "SCAN" button ,after a short beeper sound ,the temperature result will display an LCD . lf you need measure lhe temperature again , should wail lhe backlight was turned off automalic .

10

Perform the test
J1r.n®°c

4. Read the result.
The measurement result will be done in 1 seconds. The reading is shown together with green LED and three short beeps.

1 Offmode 1

=;> Short press

"ON/MODE"

o:?® [-;- ]- " ® -

Eo =;>

' M '888

or =;>

or

L Shortpress1 "SCAN"

- - -

L 1

n After1 {.!,seconds

Cc=::JJ=:seconds

° [
36.8

11

Perform the test

NOTE: · As the forehead measurement temperature is likely to be affected by sweat, oil and the surroundings,
the reading shall be taken as a reference only.

· lf the probe is placed at an angle close to the forehead measurement, the reading will be affected by surrounding temperature. Babies' skin reacts very quickly to the ambient temperature. Therefore, da not take their temperature with the lnfrared Forehead thermometer during or after breast feeding, because the skin temperature may then be lower than the internal body temperature.
· lf the reading is < 32°C (89.6° F), the display will show " LJ "[ " or " L' OF " and three beeps.

· lf the reading is :2: 37.5 °C (99.5° F) and < 43°C (109.4°F), the display will show together with red LED

and ten short beeps.

n lf the reading is >43°C (109.4° F), the display will show

H Ho·,- U

"LfF U or

and ten beeps.

· The thermometer will automatically turn off if left idle for 60 seconds.

Perform the test AS an ear measurement thermometer

---

1. Touch "ON/MODE" Switch to turn on the thermometer first.

Ear mode
2. Press the Mode button to select Ear mode. The temperature uni! flashes.

3. Insert the probe into the ear canal , then press the "SCAN" button, then the temperature result will display on LCD. lf you need measure the temperature again, should wait the backlight was turned off automatic .

12

13

Perform the test
1J1IUn1 °Mc

4. Read the result. The measurement result will be done in 1 seconds. The reading is shown on LCD.

As an obiect Measurement Thermometer

1. Touch "ON/MODE" Switch to turn on the thermometer first.

---
Object mode
2. Press the Mode button to select Object mode. The temperature unit flashed 14

Perform the test
c 01n.nuM°c

Move the probe close to the object.
Make sure the probe is flat and close to the object, not at an angle. Perform an object measurement with a distance within 0-2 cm. press the "SCAN" button ,then the temperature result will display on LCD . lf you need measure the temperature again , should wait the backlight was turned off automalic .
3. Read the result. The measurement result will be done in 1 seconds. The reading is shown together with green LED and three short beeps.

15

Meter memory
Recalling the Memory
Your thermometer stores 20 most recent readings
1. Be sure the thermometer is OFF before recalling this memory.
2. Short Press the "SCAN" button ,display a flashing "M",enter the inquire state. Each time you press the "SCAN"Button, a result will be displayed in the order of dates {latest result shown first), together with "IM)" and number (from 1 to 20). LED in green or red will appear according to the memory reading. When the memory is full, the oldest result is deleted as the new one added. When the last record displayed in the Display, press Memory Button again to return the first record.

C:J f 3[.8- M CJ,"hS CAN" so  Sh"S CAN" sw seoonds

w

M Sh "S CAN" ,

[ -M

------'

16

Meter memory Recalling the Mamory

=;>
After1 seconds

-3- JIuI J9nc B :} o,

=;>·-----=;>  - =;> D

_ f.UM ,n'-shortpress "SCAN"

Shortpress "SCAN"

['

M After1 seconds [

0 =;>
.UM After5 seoonds

Offmode

3. Delete the memory. Long press (about 8 seconds )the "Scan button" with the shutdown state ,after flashing 3 times "Clr'' icon and three beeps ,the measurement record will be deleted .

C:J CJl-"SCAN"

-M1s econds  r

=10ttmooel

17

Maintenance
Care & Cleaning
· The probe is not waterproof. Please wipe with a clean and dry cotton swab to clean the probe on the inside.
· The body of the thermometer is not water-resistant. Never pul the thermometer under a running tap or submerge il into water. Use a soft and dry clolh to clean it. Do not use abrasive cleaners.
· Store the thermometer in a cool and dry location. Free from dust and away from direct sunlight.

System troubleshooting Measurement Result

MESSAGE

WHAT IT MEANS

@
n1 ([
· @ or
L

Measured temperature falls outside the displayed temperature range of 32°C to 43°C (89.6°F to 109.4°F), is shown on the display.
· H-temperature ;;,43°c (109.4°F) · L-temperature<32°C (89.6°F)

18

19

System troubleshooting Measurement Result

MESSAGE

WHAT IT MEANS

. J1rn@°[

Measured temperature falls in normal reading, within the range of 32°C to 37.5°C (89.6°F to 99.5° F), is shown on the display
with green LED.

J77f.rJ@0E

Measured temperature falls in fever reading, ;,37_5°c (99.5°F) and s 43°C (109.4°F), is shown on the display with red LED.

20

System troubleshooting Troubleshooting

The table below shows problems you may encounter. All error messages below would be shown together with backlight. Please follow "what to do" to resolve problems. lf the problem still exists, please call your local dealer for help.

MESSAGE
uJ

WHAT IT MEANS
Appear when environmental temperature is below system operation range.

WHATTODO
Put the thermometer under operating temperature range of 16°C to 40°C(60.8°F to 104° F) Body Mode 16°C to 40°C(60.8°F to 104°F) Object Mode 5°C to 40°C(41°F to 104°F)

21

System troubleshooting Troubleshooting

MESSAGE
uJ1

WHAT IT MEANS
Appear when environmental temperature is above system operation range.

WHATTO DO
Put the thermometer under operating temperature range of 16°C to 40°C(60.8°F to 104°F) Body Mode 16°C to 40°C(60.8°F to 104°F) Object Mode 5°C to 40°C(41°F to 104°F)



Power is low and " c::::Ei: " appears on
display.

Please replace batteries as soon as possible.

22

System troubleshooting Troubleshooting

MESSAGE
crr

WHAT IT MEANS
lf the thermometer is broken or affected by EMF.

WHATTO DO
Please contact the customer service line.

23

Symbol information

SYMBOL
6...).

&
(0197
1 EC IREPI
[!] @

REFERENT
Consult instructions for use Manufacturer Serial number Caution, consult accompanying documents CE mark Authorized representative in the European Community Type BF Equipment Do not use if package is damaged

24

Specifications
Dimension & Weight: 150 x 50 x 38.5 mm, 75 g (include batteries) Power Source: 2 x 1.5 V AAA alkaline batteries Displayed temperature range: Body.Forehead: 32°C to 43.0°C (89.6°F to 109.4°F) Object: o·c to 1oo.o·c or 32°F to 199.9°F Display resolution: 0.1 Accuracy: FOR FOREHEAD MODE:
s±o.2°C(±0.4°F)from35.9°C(96.6°F)to39.0°C(102°F) s±0.3°C(±0.5°F)from32.0°C(89.6°F)to35.8°C(96.4°F) And from39.1°C(102.3°F)to43.0°C(109.4°F)
FOR EAR MODE: s±0.2°C(±0.4°F)from35.9°C(96.6°F)to39.0°C(102°F) s±0.3°C(±0.5°F)from32.0°C(89.6°F)to35.8°C(96.4°F) And from39.1°C(102.3°F)to43.0°C(109.4°F)
25

Specifications
FOR OBJECT MODE S±4°C(±7.2°F)from0°C(32°F)lo4.9°C(40.8°F) S±1°C(±2°F)from5°C(41°F)to60°C(140.0°F) S±4°C(±7.2°F)from60.1°C(140.1°F)lo 100.0°C(or 199.9°F)
Temperature unit: °C or °F Operating temperature range: Boby Mode:16°C to 35°C (60.8°F to 95°F) Object Mode: 5°C to 35°C(41°F to 95°F) Operating humidity: 85% RH or less Storage temperature range: -25°C to 55°C (-13°F to 131°F) Storage humidity: 95% RH or less Memory capacity: 20 measurements
26

Disposal
Adhere to lhe applicable regulations when disposing of lhe device. This product must not be disposed of together with domestic waste. All users are obliged to hand in all electrical or electronic devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so !hat they can be disposed of in an environmentally acceplable manner. Please remove the batteries before disposing of the device/unit. Do not dispose of old batteries with your household waste, but at a batlery colleclion stalion at a recycling site or in a shop.
27

Reference standards
Device Standard: Device Corresponds to the requirements of the standard for infrared thermometers ASTM E1965-98:2009 IEC 60601-1-2:2007/AC:2010 IEC 60601-1-4:1996 IEC 60601-1-6:2010
Electromagnetic Compatibility: Device fulfills the stipulations of the standard IEC 60601-1-2
CE:0197 The stipulations of EU-Direclive 93/42/EEC for Medical Devices Class lla have been fulfilled.
28

Warranty
· This product to be free of defects in workmanship and materials for a period on One year from the date of purchase. · If this product is found to be defective during the waranty period, please contact the supplier and send it back with the purchase receipt and the Warranty Certificate to have it repaired or replaced free of charge. After such a repair, replacement or exchange, the product will be warranted from the date of purchase. · This warranty is valid only if the Warranty Certificate and Warranty Registration Card are duly complete with date of purchase, serial number and dealer's stamp, and if the Warranty Registration Card is sent to local distributor office not later than 14 days from the date of purchase. · This warranty is void if this product has been repaired or serviced by unauthorized person. This warranty does not cover defects caused by misuse, abuse, accident, tampering, poor maintenance, fire or any other acts beyond human control. · Except as stated in lhe above paragraphs, disclaims all other warranlies, implied or expressed, including lhe warranties of merchantabilily of fitness for a particular purpose with respect to lhe use of lhis product. shall not be liable for any direct, consequential or incidental damages arising out of the use or inability to use product.
29

Two-Year Warranty Registration Card
Complete this warranty card and mail it promptly

Name

Street Address

APT#

City

Country

State/ Zip

Horne Telephone

Date of Purchase (Month-Day-Year)

1 would like to receive special offers and updates

30

PLAGE STAMP HERE

