LPM190 Series Installation Instruction

Command Access Mortise Lock

PDF preview unavailable. Download the PDF instead.

LPM190-Series-Insert-Instructions
LPM190 Series
INSERT INSTRUCTIONS
Optional: LPM193-198

A

B

Optional: REX OR LBM

Kit Includes
A. 1-LPM19X Series Mortise Lock B. 1- 51056 - 2 Position 48" Wire Harness C. 1- 50436 - 2 Position 8' Wire Harness (LPM193-98)*

TOOLS REQUIRED
· Chisel/Wood rasp File · 1" Spade Bit

SPECIFICATIONS
Latch retraction · Input Voltage: 24VDC +/- 10% · AVERAGE LATCH RETRACTION CURRENT: 1A · Average holding current: 300 ma · Wire gauge: Minimum 18 gauge
· Direct wire run - no relays or access control units in-between power supply & lock
Lever Control · Input Voltage: SPECIFY 24VDC or 12VDC +/- 10% · CURRENT 24V = 350mA · Current 12V = 700mA

Optional built-in SWITCHES
SPDT - Rated .5a @24V

REX · · ·
lbm · · ·

green= Common (C) Blue = normally open (NO) grey = normally closed (NC) green/BLK= Common (C) Blue /BLK= normally open (NO) grey/BLK = normally closed (NC)

R e c o m m e n d e d P o w e r S u p p l i e s : Use a power limited class 2 power supply
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you plan on using a non-Command power supply it must be a filtered & regulated linear power supply.

U.S. Customer Support 1-888-622-2377

Visit our website for more details www.commandaccess.com

Canada Customer Support 1-855-823-3002

Ceiling Tile

Installation Instructions

CAT

GREEN CHANNEL 1
LED

CAT LOCKING HARDWARE OPERATOR

NORMALLY OPEN DRY CONTACT FROM
ACCESS CONTROL SYSTEM
NO VOLTAGE

LOCKING

+

HARDWARE

-

NORMALLY OPEN DRY CONTACT FROM
ACCESS CONTROL SYSTEM
NO VOLTAGE

LOCKING

+

HARDWARE

-

"B"wire

LPM1 Series Installation Example
Standard Wire Run Optional Wire Run

1. The door must be prepared according to our LPM190 template and a 3/8" wire raceway. Be sure that the mortise pocket and the raceway are clear of debris prior to installation.
2. Install the "B" wire through the wire raceway leaving enough slack to "quick connect" to the mortise chassis.
3. Hardware wire "B" directly to electric hinge (CAT ETH4WH or 420W) or other transfer device, 18ga wire min.
4.Connect the wire run coming from the 26.5VDC power supply (not included - PS220 or PS210) into power
transfer. The power supply may be up to 300 feet away (see power supply wiring instructions). Note: these wires are not polarity sensitive.
US customer support 1-888-622-2377 | www.commandaccess.com | CANADA customer support 1-855-823-3002

Installation Instructions

For Lever Control Solenoid on LPM models 193-198 Only

1. The door must be machined with a 3/8" wire raceway, mortise lock pocket & prepped for a energy transfer hinge. Make sure the mortise pocket is free of debris.

2. Run the wires from the ETH hinge through the 3/8" raceway starting at the ETH hinge & exiting into the mortise pocket.
Mortise Lock Pocket

Mortise Lock Pocket

ETH Hinge Pocket

3/8 Wire Raceway

Wire Transfer Hinge

3/8 Wire Raceway

3. Screw the ETH hinge to the door. At this time DO NOT connect the hinge wires on the jamb side to the wires coming from the power supply.
1 2
3 4

4. Connect the wires exiting the mortise pocket to the Bridge Rectifier (included).

Bridge Rectifier

Mortise Lock Pocket

Wire Transfer Hinge
5.Connect the Bridge Rectifier to the plug exiting the mortise chassis.

6. Carefully slip the connected mortise lock chassis into the mortise pocket paying close attention not to pinch any wires.

Bridge Rectifier

Mortise Lock Pocket

Mortise Lock Pocket

ETH Hinge Pocket

Plug

Plug

3/8 Wire Raceway

7. Mount the chassis per manufacturer's instructions.

8. Connect the wires from the power supply at the ETH hinge on the jamb side. Connect the hinge to the jamb.

EU (Fail Secure) Bridge Rectifier
EL (Fail Safe) Bridge Rectifier

Energy Transfer Hinge

Switch EU (Fail Secure)

12VAC/DC or
24VAC/DC

Energy Transfer Hinge Switch
EL (Fail Safe)

Power Supply
12VAC/DC or
24VAC/DC

Power Supply

US customer support 1-888-622-2377 | www.commandaccess.com | CANADA customer support 1-855-823-3002

Installation Instructions

HOW TO CHANGE HANDING

1. Locate the handing screw. This screw is used to hand the handles. The
Locking side is opposite the screw.

2. To hand the latchbolt, remove the faceplate. Pull the latchbolt out of the
chassis and rotate, then release. The latchbolt is spring loaded and will
return on it's own.

LH/LHR

RH/RHR

Rotate 180 Deg.

1-1/8"
MOTOR NOTCH 2"
1"

Handing Screw

2"

Template for LPM190 Series Mortise Locks

*Additional MOTOR Notch Only required for wood doors

1-1/4" diameter cylinder hole for exterior side only
5/8" diameter thumb turn hole for interior side only
3/8" diameter through hole 1" diameter through hole 3/8" diameter through hole

2-9/64"
1" 6-1/8"
1-3/16" 1-23/32" 2-1/4"

2-7/32" 2-3/4" 3-9/32" 4-5/8"
US customer support 1-888-622-2377 | www.commandaccess.com | CANADA customer support 1-855-823-3002

