User Guide for ICP DAS models including: tM-AD2, 2-Channel Analog Input, tM-AD2 2-Channel Analog Input
tM-AD2 CR | ICPDAS-EUROPE
File Info : application/pdf, 8 Pages, 2.46MB
DocumentDocumenttM-AD2 Quick Start Quick Start for tM-AD2 Dec 2015, Version 1.0.0 Congratulations on purchasing the tM-AD2 the most popular automation solution for remote monitoring and control applications. This Quick Start Guide will provide information needed to get started with the tM-AD2. Please also consult the User Manual for detailed information on the setup and use of the tM-AD2. In addition to this guide, the shipping box includes the following items: tM-AD2 ICP DAS Website http://www.icpdas.com/ Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 1 tM-AD2 Quick Start ---------------------------------------------------------------------------------- Understanding the Hardware Specifications and Wiring Diagrams Before installing the hardware, you should have a basic understanding of hardware specification and the wiring diagrams. System Specifications Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 2 tM-AD2 Quick Start I/O Specifications Wire Connection Pin Assignment Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 3 -------------------------------------------- 2 Booting the tM-Series in Init Mode Make sure the switch placed in the "Init" position. 3 ---------------------------------------------------------------------------------Connecting to the PC and the Power Supply The tM-Series series is equipped with an RS-485 port for connection to a 232/USB converter to PC Connect to the PC using an RS-485 Converter PC RS-232 Connect to PC using a USB Converter Power Supply I-7520 PC USB RS-485 tM-Series tM-AD2 Quick Start Power Supply I-7561 RS-485 tM-Series Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 4 tM-AD2 Quick Start 4 --------------------------------------------------------------------------------Installing the DCON Utility The DCON Utility is an easy-to-use tool designed to enable simple configuration of I/O modules that use the DCON protocol. Step 1: Locate the DCON Utility The DCON Utility can be obtained from the companion CD or from the ICPDAS FTP site: ftp://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/ CD:\Napdos\Driver\DCON_Utility ---------------------------------------------------------------------------------- 5 Using the DCON Utility to Initialize the tM-Series Module The tM-Series is an I/O module based on the DCON protocol, meaning that you can use the DCON Utility to easily initialize it. Step 1: Run the DCON Utility_Pro Double-click the DCON Utility Pro Step 2: Use the COM1 port to communicate with the tM-Series Click the "COM Port" option from the menu and a dialog box will be displayed that will allow you to set the communication parameters as described in the table below. Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 5 tM-AD2 Quick Start Communication parameter Address Baud Rate Protocol Checksum Parity Factory default Value 00 9600 DCON Disabled N,8,1 Step 3: Search for the tM-Series module Click "Start Search" button from the toolbox to search for the tM-Series module. After the tM-Series module is displayed in the list, click "Stop Search" button. Start Search Stop Search Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 6 tM-AD2 Quick Start Step 4: Connect to the tM-Series After clicking on the name of the module in the list, a dialog box will be displayed. Step 5: Initialize the tM-Series module Set the "Address" field in the dialog box to 1 and then click "Setting Module Configurations " button to save the settings. 6 -------------------------------------------Rebooting the tM-Series Module in Normal Mode Make sure the INIT switch is placed in the "Normal" position. 7 ---------------------------------------------------------------------------------Starting the Module Operation After rebooting the tM-Series module, search for the module to make sure the settings have been changed. You can double click on the name of the module in the list to open Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 7 the configuration dialog box. tM-AD2 Quick Start 8 --------------------------------------------------------------------------------Modbus Address Mapping Address Description 30001 ~ 30002 Analog input value of channel 0 to 1 40001 ~ 40002 40257 ~ 40258 Analog input type code of channel 0 to 1 40481 Firmware version (low word) 40482 Firmware version (high word) 40483 Module name (low word) , 0x2001 40484 Module name (high word) , 0x0700 40485 Module address, valid range: 1 ~ 247 40486 Bits 5:0 Baud rate, 0x03 ~ 0x0A Code 0x03 0x04 0x05 0x06 Baud 1200 2400 4800 9600 Code 0x07 0x08 0x09 0x0A Baud 19200 38400 57600 115200 Bits 7:6 00: no parity, 1 stop bit 01: no parity, 2 stop bits 10: even parity, 1 stop bit 11: odd parity, 1 stop bit 40488 Modbus response delay time in ms, valid range: 0 ~ 30 40489 Host watchdog timeout value, 0 ~ 255, in 0.1s 40490 Channel enable/disable, 00h ~ 03h 40492 Host watchdog timeout count, write 0 to clear 40494 4mA under range threshold in 0.1mA, 0 ~ 40 Address Description 10129 ~ 10130 Over/under range status of channel 0 to 1 for 4 ~ 20mA or 0 ~ 20mA ranges 00129 ~ 00130 00257 Protocol, 0: DCON, 1: Modbus RTU 00258 Protocol, 0: determined by 00257, 1: Modbus ASCII 00261 1: enable, 0: disable host watchdog 00269 Modbus data format, 0: hex, 1: engineering 00270 Host watch dog timeout status, write 1 to clear host watch dog timeout status 00271 1: enable, 0: disable fast mode 00273 Reset status, 1: first read after powered on, 0: not the first read after powered on Attribute R R/W R R R R R/W R/W R/W R/W R/W R/W R/W Attribute R R/W R/W R/W R/W R/W R/W R Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 8